{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,15]],"date-time":"2025-11-15T17:11:26Z","timestamp":1763226686264,"version":"build-2065373602"},"reference-count":24,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2019,5,27]],"date-time":"2019-05-27T00:00:00Z","timestamp":1558915200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>We are studying a method based on the carrier frequency sweep for axial high resolution ultrasonic imaging to provide the range resolution that corresponds to the carrier wavelength. The first proposal for this type of method was based on the focused pulse transmission. Then, to improve the frame rate, the method was extended to a synthetic aperture-type method that transmits divergent pulses. While the method is effective in terms of the frame rate, degradation of the enhanced axial resolution performance is a concern. Therefore, using finite element method simulations and simple experiments, the performance of the synthetic aperture method with high axial resolution is evaluated via comparison with the original method using focused pulses. The evaluation confirmed that the performance degradation of the synthetic aperture method is caused by weakness in the transmitted wave intensity and deterioration of the phase coherence in the reception beamforming. Based on this result, we propose a method that is less affected by the latter cause and show its effectiveness.<\/jats:p>","DOI":"10.3390\/s19102414","type":"journal-article","created":{"date-parts":[[2019,5,27]],"date-time":"2019-05-27T11:19:27Z","timestamp":1558955967000},"page":"2414","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Improvement of Performance Degradation in Synthetic Aperture Extension of Enhanced Axial Resolution Ultrasound Imaging Based on Frequency Sweep"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7926-3684","authenticated-orcid":false,"given":"Jing","family":"Zhu","sequence":"first","affiliation":[{"name":"Graduate School of System Design, Tokyo Metropolitan University, 6-6 Asahigaoka, Hino, Tokyo 191-0065, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0212-9265","authenticated-orcid":false,"given":"Norio","family":"Tagawa","sequence":"additional","affiliation":[{"name":"Graduate School of System Design, Tokyo Metropolitan University, 6-6 Asahigaoka, Hino, Tokyo 191-0065, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2019,5,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2225","DOI":"10.1109\/TUFFC.2013.2815","article-title":"An Efficient Pulse Compression Method of Chirp-Coded Excitation in Medical Ultrasound Imaging","volume":"60","author":"Yoon","year":"2013","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1252","DOI":"10.1109\/TUFFC.2014.3032","article-title":"Fourier-Domain Beamforming: The Path to Compressed Ultrasound Imaging","volume":"61","author":"Chernyakove","year":"2014","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1109\/TUFFC.2018.2793580","article-title":"A Spatial Coherence Approach to Minimum Variance Beamforming for Plane-Wave Compounding","volume":"65","author":"Nguyen","year":"2018","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Lee, J., Moon, J.-Y., and Chang, J.H. (2018). A 35 MHz\/105 MHz Dual-Element Focused Transducer for Intravascular Ultrasound Tissue Imaging Using the Third Harmonic. Sensors, 18.","DOI":"10.3390\/s18072290"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.ultras.2018.01.002","article-title":"Experimental evaluation of ultrasound higher-order harmonic imaging with Filtered-Delay Multiply And Sum (F-DMAS) non-linear beamforming","volume":"86","author":"Matrone","year":"2018","journal-title":"Ultrasonics"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Fujiwara, M., Okubo, K., and Tagawa, N. (2009, January 20\u201323). A Novel Technique for High Resolution Ultrasound Super Resolution FM-Chirp Correlation Method (SCM). Proceedings of the IEEE International Ultrasonics Symposium, Rome, Italy.","DOI":"10.1109\/ULTSYM.2009.5441857"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1109\/58.646917","article-title":"Subaperture Processing for Ultrasonic Imaging","volume":"45","author":"Karaman","year":"1998","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"e5","DOI":"10.1016\/j.ultras.2006.07.017","article-title":"Synthetic Aperture Ultrasound Imaging","volume":"44","author":"Jensen","year":"2006","journal-title":"Ultrasonics"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Quinsac, C., Basarab, A., Girault, J., and Kouame, D. (2010, January 6\u20138). Compressed Sensing of Ultrasound Images: Sampling of Spatial and Frequency Domains. Proceedings of the IEEE Workshop Signal Processing Systems, San Francisco, CA, USA.","DOI":"10.1109\/SIPS.2010.5624793"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.1016\/j.phpro.2015.08.262","article-title":"High Frame Rate Super Resolution Imaging Based on Ultrasound Synthetic Aperture Scheme","volume":"70","author":"Wada","year":"2015","journal-title":"Phys. Procedia"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1109\/TSP.2002.1003065","article-title":"Sampling Signals with Finite Rate of Innovation","volume":"50","author":"Vetterli","year":"2002","journal-title":"IEEE Trans. Signal Process"},{"key":"ref_12","first-page":"020005","article-title":"Restoration of Scatterer Distribution based on Empirical Bayesian Learning with Consideration of Statistical Properties","volume":"32","author":"Jing","year":"2017","journal-title":"Proc. Meet. Acoust."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1109\/TAP.1986.1143830","article-title":"Multiple Emitter Location and Signal Parameter Estimation","volume":"34","author":"Schmidt","year":"1986","journal-title":"IEEE Trans. Antennas Propag."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1109\/78.388868","article-title":"On-line Spectral Estimation of Nonstationary Time Series Based on AR Model Parameters Estimation and Order Selection with a Forgetting Factor","volume":"43","author":"Goto","year":"1995","journal-title":"IEEE Trans. Signal Process."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.ultras.2008.05.005","article-title":"An Improved Automatic Time-of-Flight Picker for Medical Ultrasound Tomography","volume":"49","author":"Li","year":"2009","journal-title":"Ultrasonics"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.cageo.2016.12.005","article-title":"Identifying P Phase Arrival of Weak Events: The Akaike Information Criterion Picking Application Based on the Empirical Mode Decomposition","volume":"100","author":"Li","year":"2017","journal-title":"Comput. Geosci."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1190","DOI":"10.1109\/29.31267","article-title":"Detection of the Number of Coherent Signals by the MDL Principle","volume":"37","author":"Wax","year":"1989","journal-title":"IEEE Trans. Acoust. Speech Signal Process."},{"key":"ref_18","unstructured":"Pintelton, R., and Schoukens, J. (2001). Balancing the Model Complexity versus the Model Variability. System Identification: A Frequency Domain Approach, John Wiley & Sons."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1109\/TUFFC.2009.1067","article-title":"Coherent Plane-Wave Compounding for Very High Frame Rate Ultrasonography and Transient Elastography","volume":"56","author":"Montaldo","year":"2009","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1923","DOI":"10.1109\/TUFFC.2009.1268","article-title":"Minimum Variance Beamforming Combined with Adaptive Coherence Weighting Applied to Medical Ultrasound Imaging","volume":"56","author":"Asl","year":"2009","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2381","DOI":"10.1109\/TUFFC.2010.1706","article-title":"Eigenspace-Based Minimum Variance Beamforming Applied to Medical Ultrasound Imaging","volume":"57","author":"Asl","year":"2010","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1109\/TUFFC.2012.2244","article-title":"A Low-Complexity Adaptive Beamformer for Ultrasound Imaging Using Structured Covariance Matrix","volume":"59","author":"Asl","year":"2012","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2684","DOI":"10.1109\/TUFFC.2012.2509","article-title":"Plane-Wave Ultrasound Beamforming Using a Nonuniform Fast Fourier Transform","volume":"59","author":"Kruizinga","year":"2012","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Zhou, J., He, Y., Chirala, M., Sadler, B.M., and Hoyos, S. (2013, January 26\u201331). Compressed Digital Beamformer with Asynchronous Sampling for Ultrasound Imaging. Proceedings of the IEEE International Conference on Acoustics, Speech and Signal Processing, Vancouver, BC, Canada.","DOI":"10.1109\/ICASSP.2013.6637811"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/10\/2414\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:55:21Z","timestamp":1760187321000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/10\/2414"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,27]]},"references-count":24,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2019,5]]}},"alternative-id":["s19102414"],"URL":"https:\/\/doi.org\/10.3390\/s19102414","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2019,5,27]]}}}