{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T14:50:55Z","timestamp":1793458255197,"version":"4.5.0"},"reference-count":40,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2019,5,31]],"date-time":"2019-05-31T00:00:00Z","timestamp":1559260800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Background: Health professionals need valid devices to assess a stroke individual\u2019s ability to walk. The aim was to evaluate the validity of the estimation of the walked distance by wearable devices and the impact of the sensor\u2019s position in stroke individuals. Methods: Post-stroke patients able to walk without human assistance were equipped with several wearable devices: pedometers, Actigraph, and Sensewear Armband placed according to the manufacturers' recommendations. Participants walked for 6 min at a comfortable speed wearing all sensors at the same time. We analyzed the validity of sensor-estimated distances according to their position using Bland\u2013Altman analysis, root-mean-square error, and coefficient of correlation. Results: In total, 35 individuals were included (mean age = 65 \u00b1 15 years). The best estimations were given by the Actigraph worn on the unaffected ankle (mean bias (MB) = 22.6 \u00b1 32.4 m; p = 0.37) and by the pedometer worn on the unaffected hip (MB = 20.5 \u00b1 24.6 m; p = 0.46). The other sensors and positions provided large estimation errors over 95 m (p &lt; 0.05). Conclusion: This study led to a recommendation of a pedometer worn on the unaffected hip or an Actigraph worn on the unaffected ankle to get a valid estimation of the distance walked by stroke individuals.<\/jats:p>","DOI":"10.3390\/s19112497","type":"journal-article","created":{"date-parts":[[2019,5,31]],"date-time":"2019-05-31T11:59:56Z","timestamp":1559303996000},"page":"2497","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["Validity of the Walked Distance Estimated by Wearable Devices in Stroke Individuals"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0188-8043","authenticated-orcid":false,"given":"Maxence","family":"Compagnat","sequence":"first","affiliation":[{"name":"(Handicap, Aging, Autonomy, Environment) HAVAE EA6310, University of Limoges, 87042 Limoges Cedex, France"},{"name":"Department of Physical Medicine and Rehabilitation, University Hospital Center of Limoges, 87042 Limoges Cedex, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles Sebiyo","family":"Batcho","sequence":"additional","affiliation":[{"name":"Center for Interdisciplinary Research in Rehabilitation and Social Integration (CIRRIS), Centre Int\u00e9gr\u00e9 Universitaire de Sant\u00e9 et de Services Sociaux de la Capitale Nationale (CIUSSS-CN), G1M 2S8 Quebec, QC, Canada"},{"name":"Department of Rehabilitation, Faculty of Medicine, Universit\u00e9 Laval, G1M 2S8 Quebec, QC, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5753-4722","authenticated-orcid":false,"given":"Romain","family":"David","sequence":"additional","affiliation":[{"name":"Department of Physical Medicine and Rehabilitation, University Hospital Center of Limoges, 87042 Limoges Cedex, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3773-393X","authenticated-orcid":false,"given":"Nicolas","family":"Vuillerme","sequence":"additional","affiliation":[{"name":"AGEIS, University Grenoble Alpes, Grenoble, 38 041 Grenoble CEDEX 9, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean Yves","family":"Salle","sequence":"additional","affiliation":[{"name":"(Handicap, Aging, Autonomy, Environment) HAVAE EA6310, University of Limoges, 87042 Limoges Cedex, France"},{"name":"Department of Physical Medicine and Rehabilitation, University Hospital Center of Limoges, 87042 Limoges Cedex, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5952-3557","authenticated-orcid":false,"given":"Jean Christophe","family":"Daviet","sequence":"additional","affiliation":[{"name":"(Handicap, Aging, Autonomy, Environment) HAVAE EA6310, University of Limoges, 87042 Limoges Cedex, France"},{"name":"Department of Physical Medicine and Rehabilitation, University Hospital Center of Limoges, 87042 Limoges Cedex, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"St\u00e9phane","family":"Mandigout","sequence":"additional","affiliation":[{"name":"(Handicap, Aging, Autonomy, Environment) HAVAE EA6310, University of Limoges, 87042 Limoges Cedex, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,5,31]]},"reference":[{"key":"ref_1","first-page":"CD010200","article-title":"Interventions for improving community ambulation in individuals with stroke","volume":"13","author":"Barclay","year":"2015","journal-title":"Cochrane Database Syst Rev."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.apmr.2003.05.002","article-title":"Community ambulation after stroke: How important and obtainable is it and what measures appear predictive?","volume":"85","author":"Lord","year":"2004","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1053\/apmr.2002.33984","article-title":"Activity, participation, and quality of life 6 months poststroke","volume":"83","author":"Mayo","year":"2002","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.apmr.2013.06.017","article-title":"Speed and Distance Requirements for Community Ambulation: A Systematic Review","volume":"95","author":"Salbach","year":"2014","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1161\/01.STR.26.6.982","article-title":"Classification of Walking Handicap in the Stroke Population","volume":"26","author":"Perry","year":"1995","journal-title":"Stroke"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1123\/japa.7.1.7","article-title":"Dimensions of Mobility: Defining the Complexity and Difficulty Associated with Community Mobility","volume":"7","author":"Patla","year":"1999","journal-title":"J. Aging Phys. Act."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.1080\/09638280701654542","article-title":"Community ambulation: Environmental impacts and assessment inadequacies","volume":"30","author":"Corrigan","year":"2008","journal-title":"Disabil. Rehabil."},{"key":"ref_8","first-page":"128","article-title":"Update on distance and velocity requirements for community ambulation","volume":"33","author":"Andrews","year":"2010","journal-title":"J. Geriatr. Phys. Ther."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2532","DOI":"10.1161\/STR.0000000000000022","article-title":"Physical Activity and Exercise Recommendations for Stroke Survivors: A Statement for Healthcare Professionals From the American Heart Association\/American Stroke Association","volume":"45","author":"Billinger","year":"2014","journal-title":"Stroke"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"185","DOI":"10.2522\/ptj.20130175","article-title":"Physical Activity and Sedentary Behaviors in People With Stroke Living in the Community: A Systematic Review","volume":"94","author":"English","year":"2014","journal-title":"Phys. Ther."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.gaitpost.2008.10.061","article-title":"Variability in spatiotemporal step characteristics and its relationship to walking performance post-stroke","volume":"29","author":"Balasubramanian","year":"2009","journal-title":"Gait Posture"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.gaitpost.2004.06.009","article-title":"Gait differences between individuals with post-stroke hemiparesis and non-disabled controls at matched speeds","volume":"22","author":"Chen","year":"2005","journal-title":"Gait Posture"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1179\/1074935714Z.0000000001","article-title":"Factors related to community ambulation in patients with chronic stroke","volume":"22","author":"Lee","year":"2015","journal-title":"Top. Stroke Rehabil."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1017\/BrImp.2016.13","article-title":"Are Accelerometers and GPS Devices Valid, Reliable and Feasible Tools for Measurement of Community Ambulation After Stroke?","volume":"17","author":"Mahendran","year":"2016","journal-title":"Brain Impair."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1249\/01.MSS.0000078932.61440.A2","article-title":"Validity of 10 electronic pedometers for measuring steps, distance, and energy cost","volume":"35","author":"Crouter","year":"2003","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1249\/01.MSS.0000089342.96098.C4","article-title":"Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk","volume":"35","author":"Schneider","year":"2003","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1016\/j.apmr.2014.02.014","article-title":"Spatial-temporal gait variability poststroke: Variations in measurement and implications for measuring change","volume":"95","author":"Chisholm","year":"2014","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1177\/1545968308328732","article-title":"Influence of Speed on Walking Economy Poststroke","volume":"23","author":"Reisman","year":"2009","journal-title":"Neurorehabil. Neural Repair"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.apmr.2011.08.047","article-title":"The Use of Pedometers in Stroke Survivors: Are They Feasible and How Well Do They Detect Steps?","volume":"93","author":"Carroll","year":"2012","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"222","DOI":"10.2522\/ptj.20120525","article-title":"Accuracy of 2 activity monitors in detecting steps in people with stroke and traumatic brain injury","volume":"94","author":"Fulk","year":"2014","journal-title":"Phys. Ther."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"355","DOI":"10.2522\/ptj.20140611","article-title":"\u201cStepping Up\u201d activity poststroke: Ankle-positioned accelerometer can accurately record steps during slow walking","volume":"96","author":"Klassen","year":"2016","journal-title":"Phys. Ther."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1159\/000115178","article-title":"Motor evaluation in vascular hemiplegia","volume":"19","author":"Demeurisse","year":"1980","journal-title":"Eur. Neurol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1093\/ptj\/67.2.206","article-title":"Interrater reliability of a modified Ashworth scale of muscle spasticity","volume":"67","author":"Bohannon","year":"1987","journal-title":"Phys. Ther."},{"key":"ref_24","first-page":"14","article-title":"\u00c9valuation clinique de la marche de l\u2019h\u00e9mipl\u00e9gique vasculaire: Proposition d\u2019une modification de la functional ambulation classification","volume":"43","author":"Brun","year":"2000","journal-title":"Ann. Phys. Rehabil. Med."},{"key":"ref_25","first-page":"61","article-title":"Functional evaluation: The Barthel Index","volume":"14","author":"Mahoney","year":"1965","journal-title":"Md. State Med. J."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1886","DOI":"10.1111\/j.1365-2702.2011.04014.x","article-title":"Stroke patients\u2019 functions in personal activities of daily living in relation to sleep and socio-demographic and clinical variables in the acute phase after first-time stroke and at six months of follow-up","volume":"21","author":"Bakken","year":"2012","journal-title":"J. Clin. Nurs."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1179\/1945511915Y.0000000009","article-title":"Sitting time and physical activity after stroke: Physical ability is only part of the story","volume":"23","author":"English","year":"2016","journal-title":"Top. Stroke Rehabil."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1123\/jpah.4.1.96","article-title":"The Physical Activity Scale for Individuals with Physical Disabilities: Test-retest reliability and comparison with an accelerometer","volume":"4","author":"Streppel","year":"2007","journal-title":"J. Phys. Act. Health"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/j.apmr.2009.10.025","article-title":"Monitoring of Physical Activity after Stroke: A Systematic Review of Accelerometry-Based Measures","volume":"91","author":"Gebruers","year":"2010","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_30","first-page":"247165","article-title":"SenseWear Armband and Stroke: Validity of Energy Expenditure and Step Count Measurement during Walking","volume":"2012","author":"Manns","year":"2012","journal-title":"Stroke Res. Treat."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2009","DOI":"10.1177\/2047487317738593","article-title":"Can energy expenditure be accurately assessed using accelerometry-based wearable motion detectors for physical activity monitoring in post-stroke patients in the subacute phase?","volume":"24","author":"Mandigout","year":"2017","journal-title":"Eur. J. Prev. Cardiol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1249\/MSS.0000000000000468","article-title":"Accelerometer-based physical activity: Total volume per day and standardized measures","volume":"47","author":"Bassett","year":"2015","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/j.gaitpost.2018.12.003","article-title":"Calibration and validation of accelerometer-based activity monitors: A systematic review of machine-learning approaches","volume":"68","author":"Farrahi","year":"2019","journal-title":"Gait Posture"},{"key":"ref_34","unstructured":"(2018, March 06). ActiGraph GT3X+. Available online: http:\/\/actigraphcorp.com\/support\/activity-monitors\/gt3xplus\/."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1161\/STROKEAHA.108.523621","article-title":"How Active Are People With Stroke? Use of Accelerometers to Assess Physical Activity","volume":"40","author":"Rand","year":"2009","journal-title":"Stroke"},{"key":"ref_36","unstructured":"(2018, June 12). Podom\u00e8tre ONstep 400\u2014Geonaute. Available online: https:\/\/customercare.geonaute.com\/hc\/fr\/sections\/201652082-Podom%C3%A8tre-ONstep-400."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Lu, M.-J., Zhong, W.-H., Liu, Y.-X., Miao, H.-Z., Li, Y.-C., and Ji, M.-H. (2016). Sample Size for Assessing Agreement between Two Methods of Measurement by Bland-Altman Method. Int. J. Biostat., 12.","DOI":"10.1515\/ijb-2015-0039"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1123\/japa.2014-0033","article-title":"Effect of ActiGraph GT3X+ Position and Algorithm Choice on Step Count Accuracy in Older Adults","volume":"23","author":"Korpan","year":"2015","journal-title":"J. Aging Phys. Act."},{"key":"ref_39","first-page":"1695","article-title":"Physical activity monitoring in stroke: SenseWear Pro2 Activity accelerometer versus Yamax Digi-Walker SW-200 Pedometer","volume":"20","author":"Vanroy","year":"2013","journal-title":"Disabil. Rehabil."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1161\/STROKEAHA.111.646257","article-title":"Measuring Energy Expenditure After Stroke Validation of a Portable Device","volume":"43","author":"Moore","year":"2012","journal-title":"Stroke"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/11\/2497\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:55:07Z","timestamp":1760187307000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/11\/2497"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,31]]},"references-count":40,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2019,6]]}},"alternative-id":["s19112497"],"URL":"https:\/\/doi.org\/10.3390\/s19112497","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,31]]}}}