{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T20:02:08Z","timestamp":1760385728370,"version":"build-2065373602"},"reference-count":38,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T00:00:00Z","timestamp":1560211200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005073","name":"Agency for Defense Development","doi-asserted-by":"publisher","award":["UD160059BD"],"award-info":[{"award-number":["UD160059BD"]}],"id":[{"id":"10.13039\/501100005073","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Wearable ground reaction force (GRF) measurement systems make it possible to measure the GRF in any environment, unlike a commercial force plate. When performing kinetic analysis with the GRF, measurement of multiaxial GRF is important for evaluating forward and lateral motion during natural gait. In this paper, we propose a bendable GRF measurement system that can measure biaxial (vertical and anterior-posterior) GRF without interrupting the natural gait. Eight custom small biaxial force sensors based on an optical sensing mechanism were installed in the proposed system. The interference between two axes on the custom sensor was minimized by the independent application of a cantilever structure for the two axes, and the hysteresis and repeatability of the custom sensor were investigated. After developing the system by the installation of force sensors, we found that the degree of flexibility of the developed system was comparable to that of regular shoes by investigating the forefoot bending stiffness. Finally, we compared vertical GRF (vGRF) and anterior-posterior GRF (apGRF) measured from the developed system and force plate at the same time when the six subjects walked, ran, and jumped on the force plate to evaluate the performance of the GRF measurement system.<\/jats:p>","DOI":"10.3390\/s19112641","type":"journal-article","created":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T10:55:44Z","timestamp":1560250544000},"page":"2641","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Development of a Bendable Outsole Biaxial Ground Reaction Force Measurement System"],"prefix":"10.3390","volume":"19","author":[{"given":"Junghoon","family":"Park","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sangjoon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Youngjin","family":"Na","sequence":"additional","affiliation":[{"name":"Division of Mechanical Systems Engineering at Sookmyung Women\u2019s University, Seoul 04312, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yeongjin","family":"Kim","sequence":"additional","affiliation":[{"name":"Division of Thermal and Fluids Science, Institute for Computational Science, Faculty of Electrical and Electronics Engineering, Ton Duc Thang University, Ho Chi Minh City 758307, Vietnam"},{"name":"Department of Mechanical Engineering, Incheon National University, Incheon 22012, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jung","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2019,6,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Perry, J. (1992). Gait Analysis, SLACK Inc.","DOI":"10.1097\/01241398-199211000-00023"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1109\/TMECH.2014.2341039","article-title":"An interactive treadmill under a novel control scheme for simulating overground walking by reducing anomalous force","volume":"20","author":"Kim","year":"2015","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/TMECH.2006.886250","article-title":"A wearable biomechatronic interface for controlling robots with voluntary foot movements","volume":"12","author":"Carrozza","year":"2007","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1123\/jab.10.3.222","article-title":"A profile of ground reaction forces in professional basketball","volume":"10","author":"McClay","year":"1994","journal-title":"J. Appl. Biomech."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.gaitpost.2003.11.001","article-title":"A force measuring treadmill in clinical gait analysis","volume":"20","author":"Dierick","year":"2004","journal-title":"Gait Posture"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/S0966-6362(03)00040-7","article-title":"Reproducibility of electromyography and ground reaction force during various running techniques","volume":"19","author":"Karamanidis","year":"2004","journal-title":"Gait Posture"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1152\/japplphysiol.01380.2006","article-title":"Biomechanics of overground vs. treadmill walking in healthy individuals","volume":"104","author":"Lee","year":"2008","journal-title":"J. Appl. Physiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1249\/MSS.0b013e3181677530","article-title":"A kinematics and kinetic comparison of overground and treadmill running","volume":"40","author":"Riley","year":"2008","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Bessone, V., Petrat, J., and Schwirtz, A. (2019). Ground Reaction Forces and Kinematics of Ski Jump Landing Using Wearable Sensors. Sensors, 19.","DOI":"10.3390\/s19092011"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.jbiomech.2019.03.004","article-title":"Foot centre of pressure and ground reaction force during quadricepsresistance exercises; a comparison between force plates and a pressureinsole system","volume":"87","author":"Jonsson","year":"2019","journal-title":"J. Biomech."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1801606","DOI":"10.1002\/adfm.201801606","article-title":"Self-Powered Insole Plantar Pressure Mapping System","volume":"28","author":"Deng","year":"2018","journal-title":"Adv. Funct. Mater."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.jbiomech.2004.10.028","article-title":"Validity of the Pedar Mobile system for vertical force measurement during a seven-hour period","volume":"39","author":"Hurkmans","year":"2006","journal-title":"J. Biomech."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.gaitpost.2005.05.008","article-title":"Accuracy and repeatability of the Pedar Mobile system in long-term vertical force measurements","volume":"23","author":"Hurkmans","year":"2006","journal-title":"Gait Posture"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Ancillao, A., Tedesco, S., Barton, J., and O\u2019Flynn, B. (2018). Indirect Measurement of Ground Reaction Forces and Moments by Means of Wearable Inertial Sensors: A Systematic Review. Sensors, 18.","DOI":"10.3390\/s18082564"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2597","DOI":"10.1016\/j.jbiomech.2008.05.007","article-title":"Estimating the complete ground reaction forces withpressure insoles in walking","volume":"41","author":"Fong","year":"2008","journal-title":"J. Biomech."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1109\/TBME.2006.889769","article-title":"Ambulatory Assessment of Ankle and Foot Dynamics","volume":"54","author":"Schepers","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"10240","DOI":"10.3390\/s101110240","article-title":"Wearable Ground Reaction Force Sensor System and Its Application to the Measurement of Extrinsic Gait Variability","volume":"10","author":"Liu","year":"2010","journal-title":"Sensors"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1109\/JSEN.2011.2173763","article-title":"A Mobile Force Plate and Three-Dimensional Motion Analysis System for Three-Dimensional Gait Assessment","volume":"12","author":"Liu","year":"2012","journal-title":"IEEE Sens. J."},{"key":"ref_19","first-page":"655","article-title":"Development of Walking Analysis System Using by Motion Sensor with Mobile Forceplate","volume":"6","author":"Adachi","year":"2012","journal-title":"J. Syst. Des. Dyn."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2627","DOI":"10.1109\/JSEN.2016.2515101","article-title":"The Lower Limbs Kinematics Analysis by Wearable Sensor Shoes","volume":"16","author":"Li","year":"2016","journal-title":"IEEE Sens. J."},{"key":"ref_21","first-page":"352","article-title":"Influence of basketball shoe mass, outsole traction, and forefoot bending stiffness on three athletic movements","volume":"14","author":"Worobets","year":"2017","journal-title":"Sports Biomech."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1080\/14763140408522830","article-title":"Athletics: Increased shoe bending stiffness increases sprint performance","volume":"3","author":"Stefanyshyn","year":"2004","journal-title":"Sports Biomech."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1080\/19424280.2016.1144652","article-title":"The influence of forefoot bending stiffness of footwear on athletic injury and performance","volume":"8","author":"Stefanyshyn","year":"2016","journal-title":"Footwear Sci."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Gu, G.M., Park, K., Kim, E.J., Lee, D.Y., and Kim, J. (2015, January 11\u201314). Foot pronation monitoring using wireless biaxial force sensing system. Proceedings of the IEEE International Conference on Rehabilitation Robotics, Singapore.","DOI":"10.1109\/ICORR.2015.7281169"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Gu, G.M., and Kim, J. (2015, January 13\u201319). Wireless Multi-Axial Force Sensing Shoe for Gait Abnormalities Monitoring. Proceedings of the ASME International Mechanical Engineering Congress and Exposition, Houston, TX, USA.","DOI":"10.1115\/IMECE2015-53385"},{"key":"ref_26","first-page":"1105","article-title":"Analysis and interpretation of ground reaction forces in normal gait","volume":"8","author":"Zanchi","year":"2009","journal-title":"WSEAS Trans. Syst."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1450037","DOI":"10.1142\/S0219519414500377","article-title":"Optimal estimation of total plantar force for monitoring gait in daily life activities with low-price insole system","volume":"14","author":"Pu","year":"2014","journal-title":"J. Mech. Med. Biol."},{"key":"ref_28","unstructured":"(2018, March 19). Foot. Available online: https:\/\/en.wikipedia.org\/wiki\/Foot."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/S8756-3282(00)00342-2","article-title":"Stress fracture in military recruits: Gender differences in muscle and bone susceptibility factors","volume":"27","author":"Beck","year":"2000","journal-title":"Bone"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.2106\/00004623-200208000-00016","article-title":"Structural changes in the forefoot of individuals with diabetes and a prior plantar ulcer","volume":"84","author":"Robertson","year":"2002","journal-title":"JBJS"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"9884","DOI":"10.3390\/s120709884","article-title":"Foot plantar pressure measurement system: A review","volume":"12","author":"Zayegh","year":"2012","journal-title":"Sensors"},{"key":"ref_32","first-page":"8","article-title":"Foot pressure distribution during walking in young and old adults","volume":"5","author":"Hessert","year":"2005","journal-title":"BioMed Cent. Geriatr."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2116","DOI":"10.1016\/j.jbiomech.2012.05.038","article-title":"Spatial resolution in plantar pressure measurement revisited","volume":"45","author":"Pataky","year":"2012","journal-title":"J. Biomech."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.sna.2012.05.018","article-title":"Design and characterization of a photo-sensor based force measurement unit (FMU)","volume":"182","author":"Gu","year":"2012","journal-title":"Sens. Actuators A Phys."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/0268-0033(95)00068-2","article-title":"Relationship between vertical ground reaction force and speed during walking, slow jogging, and running","volume":"11","author":"Keller","year":"1996","journal-title":"Clin. Biomech."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1016\/j.measurement.2006.08.008","article-title":"Wearable force sensor with parallel structure for measurement of ground-reaction force. Meas","volume":"40","author":"Liu","year":"2007","journal-title":"J. Int. Meas. Confed."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1886","DOI":"10.1016\/j.jbiomech.2004.08.014","article-title":"A comparison of forefoot stiffness in running and running shoe bending stiffness","volume":"38","author":"Oleson","year":"2005","journal-title":"J. Biomech."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1152\/jappl.1998.85.2.764","article-title":"Force treadmill for measuring vertical and horizontal ground reaction forces","volume":"85","author":"Kram","year":"1998","journal-title":"J. Appl. Physiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/11\/2641\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:57:33Z","timestamp":1760187453000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/11\/2641"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,11]]},"references-count":38,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2019,6]]}},"alternative-id":["s19112641"],"URL":"https:\/\/doi.org\/10.3390\/s19112641","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2019,6,11]]}}}