{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T04:44:03Z","timestamp":1768193043821,"version":"3.49.0"},"reference-count":47,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2019,6,19]],"date-time":"2019-06-19T00:00:00Z","timestamp":1560902400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A conventional approach to making miniature or microscale gas chromatography (GC) components relies on silicon as a base material and MEMS fabrication as manufacturing processes. However, these devices often fail in medium-to-high temperature applications due to a lack of robust fluidic interconnects and a high-yield bonding process. This paper explores the feasibility of using metal additive manufacturing (AM), which is also known as metal 3D printing, as an alternative platform to produce small-scale microfluidic devices that can operate at a temperature higher than that which polymers can withstand. Binder jet printing (BJP), one of the metal AM processes, was utilized to make stainless steel (SS) preconcentrators (PCs) with submillimeter internal features. PCs can increase the concentration of gaseous analytes or serve as an inline injector for GC or gas sensor applications. Normally, parts printed by BJP are highly porous and thus often infiltrated with low melting point metal. By adding to SS316 powder sintering additives such as boron nitride (BN), which reduces the liquidus line temperature, we produce near full-density SS PCs at sintering temperatures much lower than the SS melting temperature, and importantly without any measurable shape distortion. Conversely, the SS PC without BN remains porous after the sintering process and unsuitable for fluidic applications. Since the SS parts, unlike Si, are compatible with machining, they can be modified to work with commercial compression fitting. The PC structures as well as the connection with the fitting are leak-free with relatively high operating pressures. A flexible membrane heater along with a resistance-temperature detector is integrated with the SS PCs for thermal desorption. The proof-of-concept experiment demonstrates that the SS PC can preconcentrate and inject 0.6% headspace toluene to enhance the detector\u2019s response.<\/jats:p>","DOI":"10.3390\/s19122748","type":"journal-article","created":{"date-parts":[[2019,6,19]],"date-time":"2019-06-19T10:43:32Z","timestamp":1560941012000},"page":"2748","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["A Binder Jet Printed, Stainless Steel Preconcentrator as an In-Line Injector of Volatile Organic Compounds"],"prefix":"10.3390","volume":"19","author":[{"given":"Xiaolu","family":"Huang","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Michigan State University, East Lansing, MI 48824, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6270-4239","authenticated-orcid":false,"given":"Tyler","family":"Bauder","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Michigan State University, East Lansing, MI 48824, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Truong","family":"Do","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Michigan State University, East Lansing, MI 48824, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hawke","family":"Suen","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Michigan State University, East Lansing, MI 48824, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Connor","family":"Boss","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Michigan State University, East Lansing, MI 48824, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"Kwon","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Michigan State University, East Lansing, MI 48824, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junghoon","family":"Yeom","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Michigan State University, East Lansing, MI 48824, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2019,6,19]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"15119","DOI":"10.1016\/j.ceramint.2016.06.145","article-title":"Detection of hazardous volatile organic compounds (VOCs) by metal oxide nanostructures-based gas sensors: A review","volume":"42","author":"Mirzaei","year":"2016","journal-title":"Ceram. Int."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Szulczy\u0144ski, B., and G\u0119bicki, J. (2017). Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air. Environments, 4.","DOI":"10.3390\/environments4010021"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Spinelle, L., Gerboles, M., Kok, G., Persijn, S., and Sauerwald, T. (2017). Review of Portable and Low-Cost Sensors for the Ambient Air Monitoring of Benzene and Other Volatile Organic Compounds. Sensors, 17.","DOI":"10.3390\/s17071520"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1111\/all.12793","article-title":"Volatile organic compounds in asthma diagnosis: A systematic review and meta-analysis","volume":"71","author":"Rufo","year":"2016","journal-title":"Allergy"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2759","DOI":"10.1007\/s00216-015-9200-6","article-title":"Detection of volatile organic compounds (VOCs) from exhaled breath as noninvasive methods for cancer diagnosis","volume":"408","author":"Sun","year":"2016","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.carbon.2016.08.040","article-title":"Recent advances in engineered graphene and composites for detection of volatile organic compounds (VOCs) and non-invasive diseases diagnosis","volume":"110","author":"Tripathi","year":"2016","journal-title":"Carbon"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1186\/s40694-016-0025-7","article-title":"Volatile organic compounds emitted by Trichoderma species mediate plant growth","volume":"3","author":"Lee","year":"2016","journal-title":"Fungal Biol. Biotechnol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1007\/s11869-017-0465-0","article-title":"Comparison of the volatile organic compound recovery rates of commercial active samplers for evaluation of indoor air quality in work environments","volume":"10","author":"Miyake","year":"2017","journal-title":"Air Qual. Atmos. Health"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"6941","DOI":"10.1021\/jf034410t","article-title":"Analysis of Aldehydes in Beer Using Solid-Phase Microextraction with On-Fiber Derivatization and Gas Chromatography\/Mass Spectrometry","volume":"51","author":"Vesely","year":"2003","journal-title":"J. Agric. Food Chem."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/S0021-9673(02)00696-9","article-title":"Determination of minor and trace volatile compounds in wine by solid-phase extraction and gas chromatography with mass spectrometric detection","volume":"966","author":"Aznar","year":"2002","journal-title":"J. Chromatogr. A"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.chroma.2003.11.069","article-title":"Identification of volatile organic compounds emitted by a naturally aged book using solid-phase microextraction\/gas chromatography\/mass spectrometry","volume":"1026","year":"2004","journal-title":"J. Chromatogr. A"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1016\/j.snb.2008.01.063","article-title":"MEMS-based multi-inlet\/outlet preconcentrator coated by inkjet printing of polymer adsorbents","volume":"133","author":"Alfeeli","year":"2008","journal-title":"Sens. Actuators B Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/S0950-4230(02)00042-6","article-title":"Selection of appropriate adsorption technique for recovery of VOCs: An analysis","volume":"15","author":"Ghoshal","year":"2002","journal-title":"J. Loss Prev. Process Ind."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.talanta.2011.10.025","article-title":"A micro GC detector array based on chemiresistors employing various surface functionalized monolayer-protected gold nanoparticles","volume":"88","author":"Jian","year":"2012","journal-title":"Talanta"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Bae, B., Kim, J., Yeom, J., Chen, Q., Ray, C., and Shannon, M. (2012, January 15\u201319). Development of a portable gas analyzer using a micro-Gas Chromatograph\/Flame Ionization Detector (micro-GC\/FID) for NASA\u2019s environmental missions. Proceedings of the 42nd International Conference on Environmental Systems, San Diego, CA, USA.","DOI":"10.2514\/6.2012-3435"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Azzouz, I., Marty, F., and Bourouina, T. (June, January 29). Recent advances in micro-gas chromatography\u2014The opportunities and the challenges. Proceedings of the 2017 Symposium on Design, Test, Integration and Packaging of MEMS\/MOEMS (DTIP), Bordeaux, France.","DOI":"10.1109\/DTIP.2017.7984485"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/S0920-3796(01)00378-7","article-title":"Development of a micro gas chromatograph for the analysis of hydrogen isotope gas mixtures in the fusion fuel cycle","volume":"58\u201359","author":"Kawamura","year":"2001","journal-title":"Fusion Eng. Des."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1880","DOI":"10.1109\/T-ED.1979.19791","article-title":"A gas chromatographic air analyzer fabricated on a silicon wafer","volume":"26","author":"Terry","year":"1979","journal-title":"IEEE Trans. Electron Devices"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1039\/b508596a","article-title":"First-generation hybrid MEMS gas chromatograph","volume":"5","author":"Lu","year":"2005","journal-title":"Lab Chip"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1016\/j.proeng.2014.11.413","article-title":"Development of a MEMS Preconcentrator for Micro-gas Chromatography Analyses","volume":"87","author":"James","year":"2014","journal-title":"Procedia Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.talanta.2012.09.031","article-title":"A preconcentrator chip employing \u03bc-SPME array coated with in-situ-synthesized carbon adsorbent film for VOCs analysis","volume":"101","author":"Wong","year":"2012","journal-title":"Talanta"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Alfeeli, B., and Agah, M. (2008, January 26\u201329). Micro preconcentrator with embedded 3D pillars for breath analysis applications. Proceedings of the 2008 IEEE SENSORS, Lecce, Italy.","DOI":"10.1109\/ICSENS.2008.4716547"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1109\/JMEMS.2007.892903","article-title":"Fabrication and Preliminary Results for LiGA Fabricated Nickel Micro Gas Chromatograph Columns","volume":"16","author":"Bhushan","year":"2007","journal-title":"J. Microelectromech. Syst."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1007\/s00542-006-0210-3","article-title":"Fabrication of micro-gas chromatograph columns for fast chromatography","volume":"13","author":"Bhushan","year":"2007","journal-title":"Microsyst. Technol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"4087","DOI":"10.1021\/ac800212e","article-title":"Micromachined GC Columns for Fast Separation of Organophosphonate and Organosulfur Compounds","volume":"80","author":"Radadia","year":"2008","journal-title":"Anal. Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"R35","DOI":"10.1088\/0960-1317\/14\/6\/R01","article-title":"A review of micropumps","volume":"14","author":"Laser","year":"2004","journal-title":"J. Micromech. Microeng."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1109\/JMEMS.2011.2163299","article-title":"Active MEMS Valves for Flow Control in a High-Pressure Micro-Gas-Analyzer","volume":"20","author":"Galambos","year":"2011","journal-title":"J. Microelectromech. Syst."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Galambos, P., Lantz, J.W., James, C.D., McClain, J.L., Baker, M., Anderson, R., and Simonson, R.J. (2009, January 21\u201325). Low leak rate mems valves for micro-gas-analyzer flow control. Proceedings of the TRANSDUCERS 2009\u20142009 International Solid-State Sensors, Actuators and Microsystems Conference, Denver, CO, USA.","DOI":"10.1109\/SENSOR.2009.5285749"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1893","DOI":"10.1109\/JSEN.2011.2180017","article-title":"Two-Port Static Coated Micro Gas Chromatography Column with an Embedded Thermal Conductivity Detector","volume":"12","author":"Narayanan","year":"2012","journal-title":"IEEE Sens. J."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Kaanta, B.C., Chen, H., Lambertus, G., Steinecker, W.H., Zhdaneev, O., and Zhang, X. (2009, January 25\u201329). High Sensitivity Micro-Thermal Conductivity Detector for Gas Chromatography. Proceedings of the 2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems, Sorrento, Italy.","DOI":"10.1109\/MEMSYS.2009.4805369"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2232","DOI":"10.1021\/ac702389x","article-title":"On-Column Micro Gas Chromatography Detection with Capillary-Based Optical Ring Resonators","volume":"80","author":"Shopova","year":"2008","journal-title":"Anal. Chem."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"125001","DOI":"10.1088\/0960-1317\/18\/12\/125001","article-title":"The design, fabrication and characterization of a silicon microheater for an integrated MEMS gas preconcentrator","volume":"18","author":"Yeom","year":"2008","journal-title":"J. Micromech. Microeng."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Yeom, J., Oh, I., Field, C., Radadia, A., Ni, Z., Bae, B., Han, J., Masel, R.I., and Shannon, M.A. (2008, January 13\u201317). Enhanced toxic gas detection using a MEMS preconcentrator coated with the metal organic framework absorber. Proceedings of the 2008 IEEE 21st International Conference on Micro Electro Mechanical Systems, Tucson, AZ, USA.","DOI":"10.1109\/MEMSYS.2008.4443635"},{"key":"ref_34","unstructured":"Manginell, R.P., Charles Frye-Mason, G.C., Kottenstette, R., LEWIS, P.R., and Wong, C.C. (, January 4\u20128). Microfabricated planar preconcentrator. Proceedings of the Solid State Sensors and Actuators Workshop, Hilton Head, SC, USA."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.snb.2010.09.029","article-title":"A micromachined preconcentrator for ethylene monitoring system","volume":"151","author":"Lang","year":"2010","journal-title":"Sens. Actuators B Chem."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1109\/JMEMS.2003.811748","article-title":"Microfabricated preconcentrator-focuser for a microscale gas chromatograph","volume":"12","author":"Tian","year":"2003","journal-title":"J. Microelectromech. Syst."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1109\/JMEMS.2005.844842","article-title":"Multiple-stage microfabricated preconcentrator-focuser for micro gas chromatography system","volume":"14","author":"Tian","year":"2005","journal-title":"J. Microelectromech. Syst."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.chroma.2013.10.083","article-title":"Improved performance of micro-fabricated preconcentrators using silica nanoparticles as a surface template","volume":"1322","author":"Akbar","year":"2013","journal-title":"J. Chromatogr. A"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1039\/c2lc20932b","article-title":"Microfabricated passive vapor preconcentrator\/injector designed for microscale gas chromatography","volume":"12","author":"Seo","year":"2012","journal-title":"Lab. Chip"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"3267","DOI":"10.1039\/c2lc40761b","article-title":"Configurable 3D-Printed millifluidic and microfluidic \u2018lab on a chip\u2019 reactionware devices","volume":"12","author":"Kitson","year":"2012","journal-title":"Lab Chip"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"2978","DOI":"10.1039\/C4LC00394B","article-title":"Low cost lab-on-a-chip prototyping with a consumer grade 3D printer","volume":"14","author":"Comina","year":"2014","journal-title":"Lab Chip"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.aca.2016.01.012","article-title":"3D printed titanium micro-bore columns containing polymer monoliths for reversed-phase liquid chromatography","volume":"910","author":"Gupta","year":"2016","journal-title":"Anal. Chim. Acta"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"6343","DOI":"10.1039\/C4AN01476F","article-title":"3D printed metal columns for capillary liquid chromatography","volume":"139","author":"Sandron","year":"2014","journal-title":"Analyst"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Do, T., Bauder, T.J., Suen, H., Rego, K., Yeom, J., and Kwon, P. (2018, January 18\u201322). Additively Manufactured Full-Density Stainless Steel 316L with Binder Jet Printing. Proceedings of the ASME 2018 13th International Manufacturing Science and Engineering Conference, College Station, TX, USA.","DOI":"10.1115\/MSEC2018-6681"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.ijmachtools.2017.04.006","article-title":"Process development toward full-density stainless steel parts with binder jetting printing","volume":"121","author":"Do","year":"2017","journal-title":"Int. J. Mach. Tools Manuf."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"13133","DOI":"10.1021\/acs.analchem.8b01461","article-title":"Micro Gas Chromatography: An Overview of Critical Components and Their Integration","volume":"90","author":"Regmi","year":"2018","journal-title":"Anal. Chem."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"2730","DOI":"10.1039\/c0an00322k","article-title":"Hybrid integration of injector and detector functions for microchip gas chromatography","volume":"135","author":"Bhushan","year":"2010","journal-title":"Analyst"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/12\/2748\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:59:31Z","timestamp":1760187571000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/12\/2748"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,19]]},"references-count":47,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2019,6]]}},"alternative-id":["s19122748"],"URL":"https:\/\/doi.org\/10.3390\/s19122748","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,19]]}}}