{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T03:18:56Z","timestamp":1774495136023,"version":"3.50.1"},"reference-count":40,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2019,6,25]],"date-time":"2019-06-25T00:00:00Z","timestamp":1561420800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["01158324"],"award-info":[{"award-number":["01158324"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Within this work we present AMiCUS, a Human-Robot Interface that enables tetraplegics to control a multi-degree of freedom robot arm in real-time using solely head motion, empowering them to perform simple manipulation tasks independently. The article describes the hardware, software and signal processing of AMiCUS and presents the results of a volunteer study with 13 able-bodied subjects and 6 tetraplegics with severe head motion limitations. As part of the study, the subjects performed two different pick-and-place tasks. The usability was assessed with a questionnaire. The overall performance and the main control elements were evaluated with objective measures such as completion rate and interaction time. The results show that the mapping of head motion onto robot motion is intuitive and the given feedback is useful, enabling smooth, precise and efficient robot control and resulting in high user-acceptance. Furthermore, it could be demonstrated that the robot did not move unintendedly, giving a positive prognosis for safety requirements in the framework of a certification of a product prototype. On top of that, AMiCUS enabled every subject to control the robot arm, independent of prior experience and degree of head motion limitation, making the system available for a wide range of motion impaired users.<\/jats:p>","DOI":"10.3390\/s19122836","type":"journal-article","created":{"date-parts":[[2019,6,25]],"date-time":"2019-06-25T10:52:31Z","timestamp":1561459951000},"page":"2836","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["AMiCUS\u2014A Head Motion-Based Interface for Control of an Assistive Robot"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5040-4714","authenticated-orcid":false,"given":"Nina","family":"Rudigkeit","sequence":"first","affiliation":[{"name":"Group of Sensors and Actuators, Department of Electrical Engineering and Applied Physics, Westphalian University of Applied Sciences, 45877 Gelsenkirchen, Germany"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7245-0401","authenticated-orcid":false,"given":"Marion","family":"Gebhard","sequence":"additional","affiliation":[{"name":"Group of Sensors and Actuators, Department of Electrical Engineering and Applied Physics, Westphalian University of Applied Sciences, 45877 Gelsenkirchen, Germany"}]}],"member":"1968","published-online":{"date-parts":[[2019,6,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1179\/204577211X13207446293695","article-title":"International Standards for Neurological Classification of Spinal Cord Injury (Revised 2011)","volume":"34","author":"Kirshblum","year":"2011","journal-title":"J. Spinal Cord Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/S0140-6736(02)07603-1","article-title":"Spinal-Cord Injury","volume":"359","author":"McDonald","year":"2002","journal-title":"Lancet"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1038\/sj.sc.3101893","article-title":"Incidence, Prevalence and Epidemiology of Spinal Cord Injury: What Learns a Worldwide Literature Survey?","volume":"44","author":"Wyndaele","year":"2006","journal-title":"Spinal Cord"},{"key":"ref_4","unstructured":"Alsharif, S. (2018). Gaze-Based Control of Robot Arm in Three-Dimensional Space. [Ph.D. Thesis, University of Bremen]."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Raya, R., Rocon, E., Ceres, R., and Pajaro, M. (2012, January 23\u201324). A Mobile Robot Controlled by an Adaptive Inertial Interface for Children with Physical and Cognitive Disorders. Proceedings of the 2012 IEEE International Conference on Technologies for Practical Robot Applications (TePRA), Woburn, MA, USA.","DOI":"10.1109\/TePRA.2012.6215670"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Lontis, E.R., and Struijk, L.N.S.A. (September, January 28). Alternative Design of Inductive Pointing Device for Oral Interface for Computers and Wheelchairs. Proceedings of the 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Diego, CA, USA.","DOI":"10.1109\/EMBC.2012.6346677"},{"key":"ref_7","unstructured":"Rourke, M., Clough, R., and Brackett, P. (2003). Method and Means of Voice Control of a Computer, Including Its Mouse and Keyboard. (6,668,244), U.S. Patent."},{"key":"ref_8","unstructured":"Origin Instruments Corporation (2019, May 16). Sip\/Puff Switch User Guide. Available online: http:\/\/www.orin.com\/access\/docs\/SipPuffSwitchUserGuide.pdf."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Graimann, B., Allison, B., Mandel, C., L\u00fcth, T., Valbuena, D., and Gr\u00e4ser, A. (2008). Non-invasive Brain-Computer Interfaces for Semi-autonomous Assistive Devices. Robust Intelligent Systems, Springer.","DOI":"10.1007\/978-1-84800-261-6_6"},{"key":"ref_10","unstructured":"Moon, I., Lee, M., Chu, J., and Mun, M. (2005, January 18\u201322). Wearable EMG-Based HCI for Electric-Powered Wheelchair Users with Motor Disabilities. Proceedings of the 2005 IEEE International Conference on Robotics and Automation, Barcelona, Spain."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1080\/09638280500158349","article-title":"Application of Facial Electromyography in Computer Mouse Access for People with Disabilities","volume":"28","author":"Huang","year":"2006","journal-title":"Disabil. Rehabil."},{"key":"ref_12","unstructured":"Rupp, R., Schmalfu\u00df, L., Tuga, M., Kogut, A., Hewitt, M., Meincke, J., Duttenh\u00f6fer, W., Eck, U., Mikut, R., and Reischl, M. (2015, January 12\u201313). TELMYOS\u2014A Telemetric Wheelchair Control Interface Based on the Bilateral Recording of Myoelectric Signals from Ear Muscles. Proceedings of the Technically Assisted Rehabilitation Conference (TAR 2015), Berlin, Germany."},{"key":"ref_13","unstructured":"Prentke Romich International, Ltd. (2019, May 16). Operator\u2019s Manual for the HeadMasterPlus. Available online: http:\/\/file.prentrom.com\/122\/HeadMaster-Plus-Manual.pdf."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1109\/34.845375","article-title":"Fast, Reliable Head Tracking Under Varying Illumination: An Approach Based on Registration of Texture-mapped 3D Models","volume":"22","author":"Sclaroff","year":"2000","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"ref_15","unstructured":"BJ Adaptaciones (2019, May 16). BJOY Chin. Available online: http:\/\/support.bjliveat.com\/en\/productos\/bj-853-en\/."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.sna.2010.04.019","article-title":"Wearable Inertial Mouse for Children with Physical and Cognitive Impairments","volume":"162","author":"Raya","year":"2010","journal-title":"Sens. Actuators A Phys."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Bureau, M., Azkoitia, J., Ezmendi, G., Manterola, I., Zabaleta, H., Perez, M., and Medina, J. (2007, January 12\u201315). Non-invasive, Wireless and Universal Interface for the Control of Peripheral Devices by Means of Head Movements. Proceedings of the IEEE 10th International Conference on Rehabilitation Robotics (ICORR), Noordwijk, The Netherlands.","DOI":"10.1109\/ICORR.2007.4428417"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1109\/7333.948457","article-title":"Application of Tilt Sensors in Human-Computer Mouse Interface for People with Disabilities","volume":"9","author":"Chen","year":"2001","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_19","unstructured":"Quha oy (2019, May 16). Quha Zono Gyroscopic Mouse. Available online: http:\/\/www.quha.com\/products-2\/zono\/."},{"key":"ref_20","first-page":"715","article-title":"Testing Inertial Sensor Performance as Hands-Free Human-Computer Interface","volume":"8","author":"Music","year":"2009","journal-title":"WSEAS Trans. Comput."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Mandel, C., R\u00f6fer, T., and Frese, U. (2007, January 12\u201315). Applying a 3DOF Orientation Tracker as a Human\u2013Robot Interface for Autonomous Wheelchairs. Proceedings of the IEEE 10th International Conference on Rehabilitation Robotics (ICORR 2007), Noordwijk, The Netherlands.","DOI":"10.1109\/ICORR.2007.4428406"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/s12984-015-0016-6","article-title":"Evaluation of Head Orientation and Neck Muscle EMG Signals as Three-dimensional Command Sources","volume":"12","author":"Williams","year":"2015","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Fall, C., Turgeon, P., Campeau-Lecours, A., Maheu, V., Boukadoum, M., Roy, S., Massicotte, D., Gosselin, C., and Gosselin, B. (2015, January 25\u201329). Intuitive Wireless Control of a Robotic Arm for People Living with an Upper Body Disability. Proceedings of the 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy.","DOI":"10.1109\/EMBC.2015.7319370"},{"key":"ref_24","unstructured":"Kinova Inc. (2019, May 16). KINOVA JACO\u2014Assistive Robotic Arm. Available online: https:\/\/www.kinovarobotics.com\/en\/products\/assistive-technologies\/kinova-jaco-assistive-robotic-arm."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Rudigkeit, N., Gebhard, M., and Gr\u00e4ser, A. (2015, January 7\u20139). Evaluation of Control Modes for Head Motion-Based Control with Motion Sensors. Proceedings of the 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA 2015), Torino, Italy.","DOI":"10.1109\/MeMeA.2015.7145187"},{"key":"ref_26","unstructured":"Rudigkeit, N., Gebhard, M., and Gr\u00e4ser, A. (2014, January 14\u201318). Towards a User-Friendly AHRS-Based Human-Machine Interface for a Semi-Autonomous Robot. Proceedings of the 2014 IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS2014), Chicago, IL, USA."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Wichert, R., and Klausing, H. (2016). A Novel Interface for Intuitive Control of Assistive Robots Based on Inertial Measurement Units. Ambient Assisted Living: 8. AAL Kongress 2015, Frankfurt\/M, April 29\u201330, 2015, Springer International Publishing.","DOI":"10.1007\/978-3-319-26345-8"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Rudigkeit, N., Gebhard, M., and Gr\u00e4ser, A. (2015, January 8\u201310). An Analytical Approach for Head Gesture Recognition with Motion Sensors. Proceedings of the 2015 Ninth International Conference on Sensing Technology (ICST), Auckland, New Zealand.","DOI":"10.1109\/ICSensT.2015.7933064"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1109\/TNSRE.2017.2765362","article-title":"Head Motion and Head Gesture-Based Robot Control: A Usability Study","volume":"26","author":"Jackowski","year":"2018","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_30","unstructured":"Zhang, L. (2014). Investigation of Coupling Patterns of the Cervical Spine. [Master\u2019s Thesis, University of Dundee]."},{"key":"ref_31","unstructured":"Hillcrest Laboratories, Inc. (2019, May 16). FSM-9 Modules, 2019. Available online: https:\/\/www.hillcrestlabs.com\/products\/fsm-9."},{"key":"ref_32","unstructured":"The Qt Company (2019, May 16). Qt|Cross-Platform Software Development for Embedded & Desktop. Available online: https:\/\/www.qt.io\/."},{"key":"ref_33","unstructured":"Universal Robots A\/S (2019, May 16). UR 5 Technical Specifications. Available online: http:\/\/www.universal-robots.com\/media\/50588\/ur5_en.pdf."},{"key":"ref_34","unstructured":"Robotiq Inc. (2019, May 16). Robotiq 2F-85 & 2F-140 for CB-Series Universal Robots\u2014Instruction Manual. Available online: https:\/\/assets.robotiq.com\/website-assets\/support_documents\/document\/2F-85_2F-140_Instruction_Manual_CB-Series_PDF_20190329.pdf."},{"key":"ref_35","unstructured":"Logitech Inc. (2019, May 16). Webcam C930e Data Sheet. Available online: http:\/\/www.logitech.com\/assets\/64665\/c930edatasheet.ENG.pdf."},{"key":"ref_36","unstructured":"Wikipedia Contributors (2019, May 16). Student\u2019s t-Test\u2014Wikipedia, The Free Encyclopedia. Available online: https:\/\/en.wikipedia.org\/w\/index.php?title=Student%27s_t-test&oldid=898465472."},{"key":"ref_37","first-page":"343","article-title":"Choosing Statistical Tests: Part 12 of a Series on Evaluation of Scientific Publications","volume":"107","author":"Hommel","year":"2010","journal-title":"Deutsch. \u00c4rztebl. Int."},{"key":"ref_38","unstructured":"Wikipedia Contributors (2019, May 16). Friedman Test\u2014Wikipedia, The Free Encyclopedia. Available online: https:\/\/en.wikipedia.org\/w\/index.php?title=Friedman_test&oldid=890448021."},{"key":"ref_39","unstructured":"Wikipedia Contributors (2019, May 16). Fisher\u2019s Exact Test\u2014Wikipedia, The Free Encyclopedia. Available online: https:\/\/en.wikipedia.org\/w\/index.php?title=Fisher%27s_exact_test&oldid=891629270."},{"key":"ref_40","unstructured":"Wikipedia Contributors (2019, May 16). Mann-Whitney U Test\u2014Wikipedia, The Free Encyclopedia. Available online: https:\/\/en.wikipedia.org\/w\/index.php?title=Mann%E2%80%93Whitney_U_test&oldid=899337823."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/12\/2836\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:01:12Z","timestamp":1760187672000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/12\/2836"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,25]]},"references-count":40,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2019,6]]}},"alternative-id":["s19122836"],"URL":"https:\/\/doi.org\/10.3390\/s19122836","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,25]]}}}