{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T05:02:02Z","timestamp":1782277322290,"version":"3.54.5"},"reference-count":63,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2019,7,2]],"date-time":"2019-07-02T00:00:00Z","timestamp":1562025600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100012166","name":"National Key Research and Development Program of China","doi-asserted-by":"publisher","award":["No. 2016YFD0400203"],"award-info":[{"award-number":["No. 2016YFD0400203"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Chinese National Natural Science Foundation","award":["No. 21476125."],"award-info":[{"award-number":["No. 21476125."]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The development of a sensitive, quick-responding, and robust glucose sensor is consistently pursued for use in numerous applications. Here, we propose a new method for preparing a Cu2O electrode for the electrochemical detection of glucose concentration. The Cu2O glucose electrode was prepared by in situ electrical oxidation in an alkaline solution, in which Cu2O nanoparticles were deposited on the electrode surface to form a thin film, followed by the growth of Cu(OH)2 nanorods or nanotubes. The morphology and electrocatalytic activity of a Cu2O glucose electrode can be tuned by the current density, reaction time, and NaOH concentration. The results from XRD, SEM, and a Raman spectrum show that the electrode surface was coated with cubic Cu2O nanoparticles with diameters ranging from 50 to 150 nm. The electrode exhibited a detection limit of 0.0275 mM, a peak sensitivity of 2524.9 \u03bcA\u00b7cm\u22122\u00b7mM\u22121, and a linear response range from 0.1 to 1 mM. The presence of high concentrations of ascorbic acid, uric acid, dopamine and lactose appeared to have no effects on the detection of glucose, indicating a high specificity and robustness of this electrode.<\/jats:p>","DOI":"10.3390\/s19132926","type":"journal-article","created":{"date-parts":[[2019,7,2]],"date-time":"2019-07-02T12:11:17Z","timestamp":1562069477000},"page":"2926","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":57,"title":["In Situ Oxidation of Cu2O Crystal for Electrochemical Detection of Glucose"],"prefix":"10.3390","volume":"19","author":[{"given":"Chenlin","family":"Lu","sequence":"first","affiliation":[{"name":"State Key Lab of Chemical Engineering, Ministry of Science and Technology, Beijing 100084, China"},{"name":"Department of Chemical Engineering, Tsinghua University, Beijing 100084, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhipeng","family":"Li","sequence":"additional","affiliation":[{"name":"State Key Lab of Chemical Engineering, Ministry of Science and Technology, Beijing 100084, China"},{"name":"Department of Chemical Engineering, Tsinghua University, Beijing 100084, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liwei","family":"Ren","sequence":"additional","affiliation":[{"name":"College of Biological and Pharmaceutical Sciences, China Three Gorges University, Yichang 443002, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nan","family":"Su","sequence":"additional","affiliation":[{"name":"State Key Lab of Chemical Engineering, Ministry of Science and Technology, Beijing 100084, China"},{"name":"Department of Chemical Engineering, Tsinghua University, Beijing 100084, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diannan","family":"Lu","sequence":"additional","affiliation":[{"name":"State Key Lab of Chemical Engineering, Ministry of Science and Technology, Beijing 100084, China"},{"name":"Department of Chemical Engineering, Tsinghua University, Beijing 100084, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0240-2121","authenticated-orcid":false,"given":"Zheng","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Lab of Chemical Engineering, Ministry of Science and Technology, Beijing 100084, China"},{"name":"Department of Chemical Engineering, Tsinghua University, Beijing 100084, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,7,2]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1089\/dia.2006.0059","article-title":"Noninvasive Continuous Glucose Monitoring Using Photoacoustic Technology\u2014Results from the First 62 Subjects","volume":"9","author":"Weiss","year":"2007","journal-title":"Diabetes Technol. Ther."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1128\/aem.48.2.301-305.1984","article-title":"Pseudomonas aeruginosa biosurfactant production in continuous culture with glucose as carbon source","volume":"48","author":"Guerrasantos","year":"1984","journal-title":"Appl. Environ. Microbiol."},{"key":"ref_3","unstructured":"Murphy, A.P., and Henthorne, L.R. (1999). One-Step Synthesis of Vitamin-C (l-Ascorbic Acid). (5998634A), U.S. Patent."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1021\/cr068123a","article-title":"Electrochemical glucose biosensors","volume":"108","author":"Wang","year":"2008","journal-title":"Chem. Rev."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"4805","DOI":"10.1039\/c1cs15063d","article-title":"Optical methods for sensing glucose","volume":"40","author":"Steiner","year":"2011","journal-title":"Chem. Soc. Rev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"4393","DOI":"10.1039\/c3an00451a","article-title":"A new luminol chemiluminescence sensor for glucose based on pH-dependent graphene oxide","volume":"138","author":"Hao","year":"2013","journal-title":"Analyst"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"9473","DOI":"10.1039\/c3cc45668d","article-title":"Facile fabrication of dextran-based fluorescent nanogels as potential glucose sensors","volume":"49","author":"Zhou","year":"2013","journal-title":"Chem. Commun."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1651","DOI":"10.1093\/clinchem\/45.9.1651","article-title":"Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy","volume":"45","author":"Malin","year":"1999","journal-title":"Clin. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1111\/j.1749-6632.1962.tb13623.x","article-title":"Electrode systems for continuous monitoring in cardiovascular surgery","volume":"102","author":"Clark","year":"2006","journal-title":"Ann. N. Y. Acad. Sci."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"4473","DOI":"10.1039\/c2ra22351a","article-title":"Recent advances in electrochemical glucose biosensors","volume":"3","author":"Chen","year":"2013","journal-title":"RSC Adv."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"7617","DOI":"10.1021\/nn202714c","article-title":"Hierarchically structured one-dimensional TiO2 for protein immobilization, direct electrochemistry, and mediator-free glucose sensing","volume":"5","author":"Si","year":"2011","journal-title":"ACS Nano"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1080\/00032719.2011.653900","article-title":"Direct electrochemistry of glucose oxidase at a gold electrode modified with graphene nanosheets","volume":"45","author":"Alwarappan","year":"2012","journal-title":"Anal. Lett."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"12920","DOI":"10.1021\/jp103273z","article-title":"Enzyme-doped graphene nanosheets for enhanced glucose biosensing","volume":"114","author":"Alwarappan","year":"2010","journal-title":"J. Phys. Chem. C"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.msec.2014.04.013","article-title":"A review of recent advances in nonenzymatic glucose sensors","volume":"41","author":"Tian","year":"2014","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1803","DOI":"10.1016\/j.bios.2009.12.035","article-title":"Nonenzymatic amperometric sensing of glucose by using palladium nanoparticles supported on functional carbon nanotubes","volume":"25","author":"Chen","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"4408","DOI":"10.1021\/jp912232p","article-title":"Ti\/TiO2 nanotube array\/Ni composite electrodes for nonenzymatic amperometric glucose sensing","volume":"114","author":"Wang","year":"2010","journal-title":"J. Phys. Chem. C"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1811","DOI":"10.1016\/j.elecom.2009.07.025","article-title":"Electrospun palladium (IV)-doped copper oxide composite nanofibers for non-enzymatic glucose sensors","volume":"11","author":"Wang","year":"2009","journal-title":"Electrochem. Commun."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"9673","DOI":"10.1021\/jp8019864","article-title":"Aerobic oxidation of D-glucose on support-free nanoporous gold","volume":"112","author":"Yin","year":"2008","journal-title":"J. Phys. Chem. C"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.ab.2007.01.003","article-title":"A sensitive nonenzymatic glucose sensor in alkaline media with a copper nanocluster\/multiwall carbon nanotube-modified glassy carbon electrode","volume":"363","author":"Kang","year":"2007","journal-title":"Anal. Biochem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2775","DOI":"10.1021\/ac00089a028","article-title":"Nickel-titanium alloy electrode as a sensitive and stable LCEC detector for carbohydrates","volume":"66","author":"Luo","year":"1994","journal-title":"Anal. Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/j.talanta.2006.03.004","article-title":"Electro-oxidation of glucose at self-assembled monolayers incorporated by copper particles","volume":"70","author":"Zhao","year":"2006","journal-title":"Talanta"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.talanta.2015.11.033","article-title":"Recent developments in nanostructure based electrochemical glucose sensors","volume":"149","author":"Zaidi","year":"2016","journal-title":"Talanta"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2510","DOI":"10.1016\/j.snb.2017.09.056","article-title":"Au@Cu2O core-shell structure for high sensitive non-enzymatic glucose sensor","volume":"255","author":"Su","year":"2018","journal-title":"Sens. Actuators B Chem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/j.bios.2011.11.006","article-title":"Ultrasensitive and selective non-enzymatic glucose detection using copper nanowires","volume":"31","author":"Zhang","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2482","DOI":"10.1002\/elan.200804327","article-title":"CuO nanospheres based nonenzymatic glucose sensor","volume":"20","author":"Reitz","year":"2008","journal-title":"Electroanalysis"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.jcis.2011.12.074","article-title":"Hydrothermal synthesis of CuO micro-\/nanostructures and their applications in the oxidative degradation of methylene blue and non-enzymatic sensing of glucose\/H2O2","volume":"370","author":"Kaur","year":"2012","journal-title":"J. Colloid Interface Sci."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"16802","DOI":"10.1021\/acsami.5b04614","article-title":"Hyper-Branched Cu@Cu2O Coaxial Nanowires Mesh Electrode for Ultra-Sensitive Glucose Detection","volume":"7","author":"Zhao","year":"2015","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/j.snb.2009.09.067","article-title":"Synthesis of CuO nanostructures and their application for nonenzymatic glucose sensing","volume":"144","author":"Wang","year":"2010","journal-title":"Sens. Actuators B Chem."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1612","DOI":"10.1016\/j.electacta.2009.10.034","article-title":"Development of highly sensitive non-enzymatic sensor for the selective determination of glucose and fabrication of a working model","volume":"55","author":"Babu","year":"2010","journal-title":"Electrochim. Acta"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1016\/j.cclet.2012.06.003","article-title":"A ultrasensitive nonenzymatic glucose sensor based on Cu2O polyhedrons modified Cu electrode","volume":"23","author":"Luo","year":"2012","journal-title":"Chin. Chem. Lett."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"12587","DOI":"10.1016\/S1452-3981(23)16568-0","article-title":"A facile strategy to prepare Cu2O\/Cu electrode as a sensitive enzyme-free glucose sensor","volume":"7","author":"Wang","year":"2012","journal-title":"Int. J. Electrochem. Sci."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1007\/s00604-010-0306-4","article-title":"Single step modification of copper electrode for the highly sensitive and selective non-enzymatic determination of glucose","volume":"169","author":"Babu","year":"2010","journal-title":"Microchim. Acta"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2147","DOI":"10.1007\/s10008-017-3544-0","article-title":"Nanomaterial-based electrochemical sensors for detection of glucose and insulin","volume":"21","year":"2017","journal-title":"J. Solid State Electrochem."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"36949","DOI":"10.1039\/C7RA02845H","article-title":"Recent advancements, key challenges and solutions in non-enzymatic electrochemical glucose sensors based on graphene platforms","volume":"7","author":"Amala","year":"2017","journal-title":"RSC Adv."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1016\/0013-4686(92)85055-P","article-title":"Electrochemical characterization of carbohydrate oxidation at copper electrodes","volume":"37","author":"Marioli","year":"1992","journal-title":"Electrochim. Acta"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"2842","DOI":"10.1039\/b904673a","article-title":"Highly enhanced electrocatalytic oxidation of glucose and shikimic acid at a disposable electrically heated oxide covered copper electrode","volume":"20","author":"Wei","year":"2009","journal-title":"Chem. Commun."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/S0021-9258(17)41056-8","article-title":"A study of the normal distribution of ascorbic acid between the red cells and plasma of human blood","volume":"171","author":"Sargent","year":"1947","journal-title":"J. Biol. Chem"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/S0377-1237(09)80006-3","article-title":"Adrenaline, noradrenaline and dopamine level estimation in depression: Does it help?","volume":"65","author":"Ambade","year":"2009","journal-title":"Med. J. Armed Forces India"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1791","DOI":"10.1172\/JCI42344","article-title":"Science in medicine Uric acid transport and disease","volume":"120","author":"So","year":"2010","journal-title":"J. Clin. Investig."},{"key":"ref_40","first-page":"254","article-title":"Lactose in blood in nonpregnant, pregnant, and lactating women","volume":"13","author":"Arthur","year":"1991","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"6573","DOI":"10.1039\/C6NJ00450D","article-title":"Facet-dependent nonenzymatic glucose sensing properties of Cu2O cubes and octahedra","volume":"40","author":"Tang","year":"2016","journal-title":"New J. Chem."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1016\/j.msec.2016.06.006","article-title":"Novel alkaline-reduced cuprous oxide\/graphene nanocomposites for non-enzymatic amperometric glucose sensor application","volume":"68","author":"Yazid","year":"2016","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.talanta.2017.03.008","article-title":"Flower-like MoS2decorated with Cu2O nanoparticles for non-enzymatic amperometric sensing of glucose","volume":"167","author":"Fang","year":"2017","journal-title":"Talanta"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/j.snb.2014.09.016","article-title":"Carbon quantum dots\/octahedral Cu2O nanocomposites for non-enzymatic glucose and hydrogen peroxide amperometric sensor","volume":"206","author":"Li","year":"2015","journal-title":"Sens. Actuators B Chem."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.bios.2014.03.032","article-title":"Novel helical TiO2 nanotube arrays modified by Cu2O for enzyme-free glucose oxidation","volume":"59","author":"Long","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.bios.2013.02.010","article-title":"Graphene wrapped Cu2O nanocubes: Non-enzymatic electrochemical sensors for the detection of glucose and hydrogen peroxide with enhanced stability","volume":"45","author":"Liu","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.snb.2015.03.026","article-title":"A non-enzymatic glucose sensing based on hollow cuprous oxide nanospheres in a Nafion matrix","volume":"214","author":"Cao","year":"2015","journal-title":"Sens. Actuators B Chem."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1016\/j.snb.2015.09.047","article-title":"In situ reduction of the Cu\/Cu2O\/carbon spheres composite for enzymaticless glucose sensors","volume":"222","author":"Yin","year":"2016","journal-title":"Sens. Actuators B Chem."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1527","DOI":"10.1039\/C5AY03258J","article-title":"Synthesis of Cu2O on AlOOH\/reduced graphene oxide for non-enzymatic amperometric glucose sensing","volume":"8","author":"Yang","year":"2016","journal-title":"Anal. Methods"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.electacta.2013.10.151","article-title":"Facile synthesis of monodisperse porous Cu2O nanospheres on reduced graphene oxide for non-enzymatic amperometric glucose sensing","volume":"115","author":"Zhou","year":"2014","journal-title":"Electrochim. Acta"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.snb.2015.03.011","article-title":"Facile wet-chemical synthesis of differently shaped cuprous oxide particles and a thin film: Effect of catalyst morphology on the glucose sensing performance","volume":"214","author":"Neetzel","year":"2015","journal-title":"Sens. Actuators B Chem."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"B248","DOI":"10.1149\/2.1101606jes","article-title":"Simple Electrochemical Synthesis of Cuprous Oxide Nanoparticles and Their Application as a Non-Enzymatic Glucose Sensor","volume":"163","author":"Khedekar","year":"2016","journal-title":"J. Electrochem. Soc."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"9696","DOI":"10.1007\/s10853-016-0202-3","article-title":"Fast synthesis of hierarchical cuprous oxide for nonenzymatic glucose biosensors with enhanced sensitivity","volume":"51","author":"He","year":"2016","journal-title":"J. Mater. Sci."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.snb.2017.04.125","article-title":"Precisely quantified catalyst based on in situ growth of Cu2O nanoparticles on a graphene 3D network for highly sensitive glucose sensor","volume":"250","author":"Wang","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"16949","DOI":"10.1039\/c1jm11641j","article-title":"Assembly of Ni(OH)2 nanoplates on reduced graphene oxide: A two dimensional nanocomposite for enzyme-free glucose sensing","volume":"21","author":"Zhang","year":"2011","journal-title":"J. Mater. Chem."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"7369","DOI":"10.1016\/S1452-3981(23)10974-6","article-title":"Controllable growth of cobalt oxide nanoparticles on reduced graphene oxide and its application for highly sensitive glucose sensor","volume":"9","author":"Zheng","year":"2014","journal-title":"Int. J. Electrochem. Sci."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"2259","DOI":"10.1007\/s00604-016-1862-z","article-title":"Amperometric enzyme-free glucose sensor based on the use of a reduced graphene oxide paste electrode modified with electrodeposited cobalt oxide nanoparticles","volume":"183","author":"Heidari","year":"2016","journal-title":"Microchim. Acta"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/j.snb.2016.06.132","article-title":"Insulin impregnated reduced graphene oxide\/Ni(OH)2 thin films for electrochemical insulin release and glucose sensing","volume":"237","author":"Belkhalfa","year":"2016","journal-title":"Sens. Actuators B Chem."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1016\/j.snb.2016.07.126","article-title":"Nanoparticles-assembled NiO nanosheets templated by graphene oxide film for highly sensitive non-enzymatic glucose sensing","volume":"238","author":"Zhang","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.electacta.2011.11.089","article-title":"DNA-dispersed graphene\/NiO hybrid materials for highly sensitive non-enzymatic glucose sensor","volume":"73","author":"Lv","year":"2012","journal-title":"Electrochim. Acta"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1021\/ac00176a016","article-title":"Model for a Thermoelectric Enzyme Glucose Sensor","volume":"61","author":"Guilbeau","year":"1989","journal-title":"Anal. Chem."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1073\/pnas.95.1.294","article-title":"Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin","volume":"95","author":"Schmidtke","year":"1998","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1853","DOI":"10.1021\/ac991018z","article-title":"Simulations of the frequency response of implantable glucose sensors","volume":"72","author":"Jablecki","year":"2000","journal-title":"Anal. Chem."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/13\/2926\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:01:49Z","timestamp":1760187709000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/13\/2926"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,2]]},"references-count":63,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2019,7]]}},"alternative-id":["s19132926"],"URL":"https:\/\/doi.org\/10.3390\/s19132926","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,2]]}}}