{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T16:26:57Z","timestamp":1775579217168,"version":"3.50.1"},"reference-count":32,"publisher":"MDPI AG","issue":"15","license":[{"start":{"date-parts":[[2019,8,2]],"date-time":"2019-08-02T00:00:00Z","timestamp":1564704000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"The Science and Technology Project of State Grid Corporation of China","award":["NYB17201800314"],"award-info":[{"award-number":["NYB17201800314"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>There are Rogowski coils of various shapes in the on-site measurement, and it is difficult to calculate the electrical quantities of Rogowski coils of curved skeleton and circular cross-section by simulation software. This paper proposes a theoretical derivation to calculate the mutual inductance between the conductors of any shape and Rogowski coils with skeletons of any shape. Based on the derivation, the influence of four skeleton shapes of Rogowski coils and four shapes of the primary conductors on the mutual inductance of Rogowski coils are studied by the comparison between the ideal cases and some non-ideal ones. The gap and gap compensation of the openable Rogowski coils are also considered. Experiments verify the numerical results according to the derivation. It is shown that to reduce the errors of the measurement the circular skeleton deformation should be avoided, the coil\u2019s skeleton should be with curved angle, the primary conductor should be as straight as possible and should go through the center of the skeletons vertically. Furthermore, for the Rogowski coils of the rectangular skeleton, we propose a new skeleton structure to reduce the deviation influence of the primary conductors.<\/jats:p>","DOI":"10.3390\/s19153397","type":"journal-article","created":{"date-parts":[[2019,8,2]],"date-time":"2019-08-02T11:58:16Z","timestamp":1564747096000},"page":"3397","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Modeling and Analyzing the Mutual Inductance of Rogowski Coils of Arbitrary Skeleton"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0763-0182","authenticated-orcid":false,"given":"Xiaoyu","family":"Liu","sequence":"first","affiliation":[{"name":"School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui","family":"Huang","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chaoqun","family":"Jiao","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2019,8,2]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1109\/19.492777","article-title":"Machinable Rogowski Coil, Design, and Calibration","volume":"45","author":"Ramboz","year":"1996","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Liu, Y., Xie, X., Hu, Y., Qian, Y., Sheng, G., and Jiang, X. (2016). A Novel Transient Fault Current Sensor Based on the PCB Rogowski Coil for Overhead Transmission Lines. Sensors, 16.","DOI":"10.3390\/s16050742"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1109\/JSEN.2014.2362940","article-title":"The Rogowski Coil Principles and Applications: A Review","volume":"15","author":"Samimi","year":"2015","journal-title":"IEEE Sens. J."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1109\/JSEN.2009.2013497","article-title":"Rogowski Sensor for Plasma Current Measurement in J-TEXT","volume":"9","author":"Qing","year":"2009","journal-title":"IEEE Sens. J."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"4062","DOI":"10.1109\/TIE.2009.2025715","article-title":"Motor Fault Detection Using a Rogowski Sensor Without an Integrator","volume":"56","author":"Poncelas","year":"2009","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_6","first-page":"8420","article-title":"Differential Reconstruction Method for Power Frequency AC Current Measurement Using Rogowski coil","volume":"16","author":"Ibrahim","year":"2016","journal-title":"IEEE Sens. J."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Ray, W.F., and Hewson, C.R. (2000, January 3\u20134). Rogowski transducers for measuring large magnitude short duration pulses. Proceedings of the IEE Symposium on Pulsed Power 2000 (Digest No. 2000\/053), London, UK.","DOI":"10.1049\/ic:20000292"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1109\/TIM.2009.2023821","article-title":"Self-integrating Rogowski coil for high-impulse current measurement","volume":"59","author":"Metwally","year":"2010","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1049\/iet-smt.2012.0132","article-title":"Investigation on Rogowski coil performance for structuring its design methodology","volume":"7","author":"Hemmati","year":"2013","journal-title":"IET Sci. Meas. Technol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"65107","DOI":"10.1063\/1.1921427","article-title":"Implementation of a Rogowski coil for the measurement of partial discharges","volume":"76","author":"Robles","year":"2005","journal-title":"Rev. Sci. Instrum."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.1109\/TPEL.2016.2552039","article-title":"Application of an Efficient Rogowski Coil Sensor for Switch Fault Diagnosis and Capacitor ESR Monitoring in Nonisolated Single-Switch DC\u2013DC Converters","volume":"32","author":"Farjah","year":"2017","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2053","DOI":"10.1109\/JSEN.2013.2252614","article-title":"An Opyically-Interrogated Rogowski Coil for Passive, Multiplexable Current Measurement","volume":"13","author":"Orr","year":"2013","journal-title":"IEEE Sens. J."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1109\/JSEN.2012.2222372","article-title":"Performance Improvement of Slow-Wave Rogowski Coils for High Impulse Current Measurement","volume":"13","author":"Metwally","year":"2013","journal-title":"IEEE Sens. J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1109\/TIM.2012.2212502","article-title":"Digital Compensation of Rogowski Coil\u2019s Output Voltage","volume":"62","author":"Hemmati","year":"2013","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1049\/iet-smt.2009.0124","article-title":"Calibration of on-line partial discharge measuring system using Rogowski coil in covered-conductor overhead distribution networks","volume":"5","author":"Hashmi","year":"2011","journal-title":"IET Sci. Meas. Technol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1016\/j.epsr.2016.03.039","article-title":"Implementation of noise-immune Rogowski coils for busbar differential protection modernization","volume":"140","author":"Solovev","year":"2016","journal-title":"Electr. Power Syst. Res."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1054","DOI":"10.1109\/TIM.2008.2007031","article-title":"Onsite Calibration of a Current Transformer Using a Rogowski Coil","volume":"58","author":"Suomalainen","year":"2009","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.1109\/TIM.2010.2090694","article-title":"Characterization and Error Compensation of a Rogowski Coil in the Presence of Harmonics","volume":"60","author":"Cataliotti","year":"2011","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1109\/TIM.2010.2051591","article-title":"Critical Parameters for Mutual Inductance Between Rogowski Coil and Primary Conductor","volume":"60","author":"Marracci","year":"2011","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.measurement.2013.11.048","article-title":"Effect of geometrical parameters on high frequency performance of Rogowski coil for partial discharge measurements","volume":"49","author":"Shafiq","year":"2014","journal-title":"Measurement"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Xu, M., Yan, J., Geng, Y., Zhang, K., and Sun, C. (2018). Research on the Factors Influencing the Measurement Errors of the Discrete Rogowski Coil. Sensors, 18.","DOI":"10.3390\/s18030847"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Yu, H., Qian, Z., Liu, H., and Qu, J. (2018). Circular Array of Magnetic Sensors for Current Measurement: Analisis for Error Caused by Position of Conductor. Sensors, 18.","DOI":"10.20944\/preprints201801.0272.v1"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1109\/TIM.2008.928412","article-title":"Mutual Inductance of a Precise Rogowski Coil in Dependence of the Position of Primary Conductor","volume":"58","author":"Ferkovic","year":"2009","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"3045","DOI":"10.1109\/TIM.2015.2444254","article-title":"Influence of Axial Inclination of the Primary Conductor on Mutual Inductance of a Precise Rogowski Coil","volume":"64","year":"2015","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1109\/TIM.2010.2060223","article-title":"Evaluation of Flexible Rogowski Coil Performances in Power Frequency Applications","volume":"60","author":"Chiampi","year":"2011","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1109\/TEMC.2013.2252906","article-title":"Design of PCB Rogowski Coil and Analysis of Anti-interference Property","volume":"58","author":"Tao","year":"2016","journal-title":"IEEE Trans. Electromagn. Compat."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1109\/67.595293","article-title":"Rogowski Coils Suit Relay Protection and Measurement","volume":"10","author":"Kojovic","year":"1997","journal-title":"IEEE Comput. Applicat. Power"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1109\/TIM.2008.2011093","article-title":"Calibration of Rogowski Coils at Power Frequencies Using Digital Sampling","volume":"58","author":"Djokic","year":"2009","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_29","unstructured":"Hong, Z. (2010). Chapter 17th the Magnetic Field and Its Source. University Physics Electromagnetism, Tsinghua University Press. [3rd ed.]. (In Chinese)."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"4106","DOI":"10.1109\/JSEN.2019.2896443","article-title":"Mutual Inductance between Arbitrary Conductor and Rogowski Coil with Circular Skeleton and Gap Compensation","volume":"19","author":"Liu","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_31","unstructured":"Yu, L. (2000). Chapter Third an Introduction to Engineering Electromagnetic Fields, High Education Press. [1st ed.]. (In Chinese)."},{"key":"ref_32","unstructured":"Guo, X.J. (2009). The Research and Design on Rogowski Coil Sensor Head of Electronic Current Transformer for Measurement. [Master\u2019s Thesis, Shandong Agricultural University]. (In Chinese)."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/15\/3397\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:12:40Z","timestamp":1760188360000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/15\/3397"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,2]]},"references-count":32,"journal-issue":{"issue":"15","published-online":{"date-parts":[[2019,8]]}},"alternative-id":["s19153397"],"URL":"https:\/\/doi.org\/10.3390\/s19153397","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,2]]}}}