{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T17:32:23Z","timestamp":1778088743168,"version":"3.51.4"},"reference-count":32,"publisher":"MDPI AG","issue":"16","license":[{"start":{"date-parts":[[2019,8,17]],"date-time":"2019-08-17T00:00:00Z","timestamp":1566000000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>For long-term and more convenience electrocardiograph (ECG) monitoring, an active- electrode-based ECG monitoring system, which can measure ECG through clothes, is proposed in this paper. The hardware of the system includes active electrodes, signal processing and data transmission modules and the software mainly includes a denoising algorithm based on empirical mode decomposition (EMD). Then the proposed system was verified using the comparison of the ECG signals measured synchronously by active electrodes and Ag\/AgCl electrodes. In addition, three flexible materials, including conductive textile, copper foil tape and a flexible printed circuit (FPC) are developed for the sensing layer with active electrodes. To compare the performance of these three materials for the sensing layer, the ECG signals of 10 subjects were measured by different materials in three postures and several indexes for quality evaluation were calculated. Results show that effective and clear ECG waveforms can be measured by all three kinds of materials and the quality of ECG signals measured by FPC is the best by conducting a significant t-test for signal quality indexes of three materials.<\/jats:p>","DOI":"10.3390\/s19163585","type":"journal-article","created":{"date-parts":[[2019,8,19]],"date-time":"2019-08-19T06:10:14Z","timestamp":1566195014000},"page":"3585","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":39,"title":["Comparison of Active Electrode Materials for Non-Contact ECG Measurement"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7573-9940","authenticated-orcid":false,"given":"Shun","family":"Peng","sequence":"first","affiliation":[{"name":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai 200433, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7376-2805","authenticated-orcid":false,"given":"Ke","family":"Xu","sequence":"additional","affiliation":[{"name":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai 200433, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Chen","sequence":"additional","affiliation":[{"name":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai 200433, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2019,8,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Yapici, M., and Alkhidir, T. (2017). Intelligent medical garments with graphene-functionalized smart-cloth ECG sensors. Sensors, 17.","DOI":"10.3390\/s17040875"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Higashi, Y., Yokota, Y., and Naruse, Y. (2017, January 11\u201315). Signal correlation between wet and original dry electrodes in electroencephalogram according to the contact impedance of dry electrodes. Proceedings of the 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Jeju Island, Korea.","DOI":"10.1109\/EMBC.2017.8037010"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1750","DOI":"10.3390\/s150101750","article-title":"Embroidered electrode with silver\/titanium coating for long-term ECG monitoring","volume":"15","author":"Weder","year":"2015","journal-title":"Sensors"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1088\/0967-3334\/21\/2\/307","article-title":"A direct comparison of wet, dry and insulating bioelectric recording electrodes","volume":"21","author":"Searle","year":"2000","journal-title":"Physiol. Meas."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2898","DOI":"10.1109\/JSEN.2012.2204339","article-title":"PDMS-based low cost flexible dry electrode for long-term EEG measurement","volume":"12","author":"Wang","year":"2012","journal-title":"IEEE Sens. J."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Lou, C., Li, R., Li, Z., Liang, T., Wei, Z., Run, M., Yan, X., and Liu, X. (2016). Flexible graphene electrodes for prolonged dynamic ECG monitoring. Sensors, 16.","DOI":"10.3390\/s16111833"},{"key":"ref_7","unstructured":"Lim, Y.K., Kim, K.K., and Park, K.S. (2004, January 1\u20135). The ECG measurement in the bathtub using the insulated electrodes. Proceedings of the 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Francisco, CA, USA."},{"key":"ref_8","unstructured":"Kim, K.K., Lim, Y.K., and Park, K.S. (2004, January 1\u20135). The electrically noncontacting ECG measurement on the toilet seat using the capacitively-coupled insulated electrodes. Proceedings of the 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Francisco, CA, USA."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1109\/RBME.2018.2840336","article-title":"Noncontact wearable wireless ECG systems for long-term monitoring","volume":"11","author":"Majumder","year":"2018","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"6023","DOI":"10.1109\/JSEN.2018.2844122","article-title":"Wireless capacitive-based ECG sensing for feature extraction and mobile health monitoring","volume":"18","author":"Wannenburg","year":"2018","journal-title":"IEEE Sens. J."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Xu, X., Liang, Y., He, P., and Yang, J. (2019). Adaptive motion artifact reduction based on empirical wavelet transform and wavelet thresholding for the non-contact ECG monitoring systems. Sensors, 19.","DOI":"10.3390\/s19132916"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"3802","DOI":"10.1109\/JSEN.2016.2532599","article-title":"Capacitively coupled electrocardiogram measuring system and noise reduction by singular spectrum analysis","volume":"16","author":"Yang","year":"2016","journal-title":"IEEE Sens. J."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"19237","DOI":"10.3390\/s150819237","article-title":"A hygroscopic sensor electrode for fast stabilized non-contact ECG signal acquisition","volume":"15","author":"Fong","year":"2015","journal-title":"Sensors"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Lacirignola, F., and Pasero, E. (2017, January 4\u20136). Hardware design of a wearable ECG-sensor: Strategies implementation for improving CMRR and reducing noise. Proceedings of the 2017 European Conference on Circuit Theory and Design (ECCTD), Catania, Italy.","DOI":"10.1109\/ECCTD.2017.8093244"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Jedari, E., Rashidzadeh, R., Mirhassani, M., and Ahmadi, M. (May, January 30). Two-electrode ECG measurement circuit using a feed forward CMRR enhancement method. Proceedings of the 2017 IEEE 30th Canadian Conference on Electrical and Computer Engineering (CCECE), Windsor, ON, Canada.","DOI":"10.1109\/CCECE.2017.7946612"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.bspc.2011.11.003","article-title":"Denoising of ECG signals based on noise reduction algorithms in EMD and wavelet domains","volume":"7","author":"Kabir","year":"2012","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.compbiomed.2007.06.003","article-title":"ECG signal denoising and baseline wander correction based on the empirical mode decomposition","volume":"38","author":"Weng","year":"2008","journal-title":"Comput. Biol. Med."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.compbiomed.2011.10.012","article-title":"Empirical mode decomposition based ECG enhancement and QRS detection","volume":"42","author":"Pal","year":"2012","journal-title":"Comput. Biol. Med."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Murugappan, M., Thirumani, R., Omar, M.I., and Murugappan, S. (2014, January 7\u20139). Development of cost effective ECG data acquisition system for clinical applications using LabVIEW. Proceedings of the 2014 IEEE 10th International Colloquium on Signal Processing and Its Applications, Kuala Lumpur, Malaysia.","DOI":"10.1109\/CSPA.2014.6805729"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Ying, G., Zhenzhen, W., Li, K., Qiang, D., and Jinghui, L. (2018, January 9\u201311). Heart sound and ECG signal analysis and detection system based on LabVIEW. Proceedings of the 2018 Chinese Control and Decision Conference (CCDC), Shenyang, China.","DOI":"10.1109\/CCDC.2018.8408102"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Benesty, J., Chen, J., Huang, Y., and Cohen, I. (2009). Pearson correlation coefficient. Noise Reduction in Speech Processing, Springer.","DOI":"10.1007\/978-3-642-00296-0_5"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"255","DOI":"10.2307\/2532051","article-title":"A concordance correlation coefficient to evaluate reproducibility","volume":"Volume 45","author":"Lawrence","year":"1989","journal-title":"Biometrics"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Thap, T., Yoon, K.H., and Lee, J. (2016). Graphite based electrode for ECG monitoring: Evaluation under freshwater and saltwater conditions. Sensors, 16.","DOI":"10.3390\/s16040542"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.dsp.2005.12.003","article-title":"Optimal selection of wavelet basis function applied to ECG signal denoising","volume":"16","author":"Singh","year":"2006","journal-title":"Digit. Signal Process."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1088\/0967-3334\/17\/2\/003","article-title":"The origin of skin-stretch-caused motion artifacts under electrodes","volume":"17","author":"Talhouet","year":"1996","journal-title":"Physiol. Meas."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"87","DOI":"10.3390\/machines2010087","article-title":"Problems in assessment of novel biopotential front-end with dry electrode: A brief review","volume":"2","author":"Gargiulo","year":"2014","journal-title":"Machines"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1088\/0967-3334\/29\/1\/002","article-title":"Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter","volume":"29","author":"Li","year":"2007","journal-title":"Physiol. Meas."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Castro, I., Varon, C., Torfs, T., Van Huffel, S., Puers, R., and Van Hoof, C. (2018). Evaluation of a multichannel non-contact ECG system and signal quality algorithms for sleep apnea detection and monitoring. Sensors, 18.","DOI":"10.3390\/s18020577"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1007\/s00521-005-0013-y","article-title":"Application of independent component analysis in removing artefacts from the electrocardiogram","volume":"15","author":"He","year":"2006","journal-title":"Neural Comput. Appl."},{"key":"ref_30","unstructured":"Clifford, G.D., Azuaje, F., and McSharry, P. (2006). Advanced Methods and Tools for ECG Data Analysis, Artech House."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Martinek, R., Kahankova, R., Nazeran, H., Konecny, J., Jezewski, J., Janku, P., Bilik, P., Zidek, J., Nedoma, J., and Fajkus, M. (2017). Non-invasive fetal monitoring: A maternal surface ECG electrode placement-based novel approach for optimization of adaptive filter control parameters using the LMS and RLS algorithms. Sensors, 17.","DOI":"10.3390\/s17051154"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1007\/s11517-006-0119-0","article-title":"Heart rate variability: A review","volume":"44","author":"Acharya","year":"2006","journal-title":"Med. Biol. Eng. Comput."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/16\/3585\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:11:53Z","timestamp":1760188313000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/16\/3585"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,17]]},"references-count":32,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2019,8]]}},"alternative-id":["s19163585"],"URL":"https:\/\/doi.org\/10.3390\/s19163585","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,17]]}}}