{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T13:09:59Z","timestamp":1785330599317,"version":"3.55.0"},"reference-count":29,"publisher":"MDPI AG","issue":"17","license":[{"start":{"date-parts":[[2019,8,24]],"date-time":"2019-08-24T00:00:00Z","timestamp":1566604800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Even if still at an early stage of development, non-invasive continuous glucose monitoring (NI-CGM) sensors represent a promising technology for optimizing diabetes therapy. Recent studies showed that the Multisensor provides useful information about glucose dynamics with a mean absolute relative difference (MARD) of 35.4% in a fully prospective setting. Here we propose a method that, exploiting the same Multisensor measurements, but in a retrospective setting, achieves a much better accuracy. Data acquired by the Multisensor during a long-term study are retrospectively processed following a two-step procedure. First, the raw data are transformed to a blood glucose (BG) estimate by a multiple linear regression model. Then, an enhancing module is applied in cascade to the regression model to improve the accuracy of the glucose estimation by retrofitting available BG references through a time-varying linear model. MARD between the retrospectively reconstructed BG time-series and reference values is 20%. Here, 94% of values fall in zone A or B of the Clarke Error Grid. The proposed algorithm achieved a level of accuracy that could make this device a potential complementary tool for diabetes management and also for guiding prediabetic or nondiabetic users through life-style changes.<\/jats:p>","DOI":"10.3390\/s19173677","type":"journal-article","created":{"date-parts":[[2019,8,26]],"date-time":"2019-08-26T04:38:23Z","timestamp":1566794303000},"page":"3677","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Retrospective Continuous-Time Blood Glucose Estimation in Free Living Conditions with a Non-Invasive Multisensor Device"],"prefix":"10.3390","volume":"19","author":[{"given":"Giada","family":"Acciaroli","sequence":"first","affiliation":[{"name":"Department of Information Engineering, University of Padova, 35131 Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9875-6329","authenticated-orcid":false,"given":"Mattia","family":"Zanon","sequence":"additional","affiliation":[{"name":"Biovotion AG, 8008 Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8041-2280","authenticated-orcid":false,"given":"Andrea","family":"Facchinetti","sequence":"additional","affiliation":[{"name":"Department of Information Engineering, University of Padova, 35131 Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Caduff","sequence":"additional","affiliation":[{"name":"Biovotion AG, 8008 Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3248-1393","authenticated-orcid":false,"given":"Giovanni","family":"Sparacino","sequence":"additional","affiliation":[{"name":"Department of Information Engineering, University of Padova, 35131 Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,8,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1177\/193229681000400632","article-title":"Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises","volume":"4","author":"Vaddiraju","year":"2010","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.bios.2013.09.043","article-title":"In vivo evaluation of a chip based near infrared sensor for continuous glucose monitoring","volume":"53","author":"Klotzbuecher","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Chen, C., Zhao, X.-L., Li, Z.-H., Zhu, Z.-G., Qian, S.-H., and Flewitt, A.J. (2017). Current and Emerging Technology for Continuous Glucose Monitoring. Sensors, 17.","DOI":"10.3390\/s17010182"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1021\/acs.accounts.6b00472","article-title":"Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy","volume":"50","author":"Pandey","year":"2017","journal-title":"Acc. Chem. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"5429","DOI":"10.1021\/ac050429e","article-title":"Noninvasive glucose sensing","volume":"77","author":"Arnold","year":"2005","journal-title":"Anal. Chem."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Cappon, G., Acciaroli, G., Vettoretti, M., Facchinetti, A., and Sparacino, G. (2017). Wearable continuous glucose monitoring sensors: A revolution in diabetes treatment. Electronics, 6.","DOI":"10.3390\/electronics6030065"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1097\/MED.0b013e32835edb9d","article-title":"Continuous glucose monitors","volume":"20","author":"Lane","year":"2013","journal-title":"Curr. Opin. Endocrinol. Diabetes Obes."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1089\/dia.2008.0133","article-title":"The Chemistry of Commercial Continuous Glucose Monitors","volume":"11","author":"McGarraugh","year":"2009","journal-title":"Diabetes Technol. Ther."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2263","DOI":"10.2337\/diacare.25.12.2263","article-title":"Noninvasive Blood Glucose Monitoring with Optical Coherence Tomography: A pilot study in human subjects","volume":"25","author":"Larin","year":"2002","journal-title":"Diabetes Care"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1016\/j.bios.2006.01.031","article-title":"Non-invasive glucose monitoring in patients with diabetes: A novel system based on impedance spectroscopy","volume":"22","author":"Caduff","year":"2006","journal-title":"Biosens. Bioelectron."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3794","DOI":"10.1016\/j.bios.2011.02.034","article-title":"Characteristics of a multisensor system for non invasive glucose monitoring with external validation and prospective evaluation","volume":"26","author":"Caduff","year":"2011","journal-title":"Biosens. Bioelectron."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1089\/dia.2009.0095","article-title":"Cutaneous Blood Perfusion as a Perturbing Factor for Noninvasive Glucose Monitoring","volume":"12","author":"Caduff","year":"2010","journal-title":"Diabetes Technol. Ther."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1088\/0967-3334\/32\/1\/009","article-title":"The effect of blood content on the optical and dielectric skin properties","volume":"32","author":"Zakharov","year":"2010","journal-title":"Physiol. Meas."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.snb.2009.04.023","article-title":"Multiparameter techniques for non-invasive measurement of blood glucose","volume":"140","author":"Amaral","year":"2009","journal-title":"Sens. Actuators B Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1177\/193229681000400312","article-title":"Noninvasive Glucose Monitoring: Increasing Accuracy by Combination of Multi-Technology and Multi-Sensors","volume":"4","author":"Gal","year":"2010","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_16","first-page":"1047","article-title":"Non-invasive continuous glucose monitoring: Improved accuracy of point and trend estimates of the Multisensor system","volume":"50","author":"Zanon","year":"2012","journal-title":"Med. Boil. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2013\/793869","article-title":"Regularised Model Identification Improves Accuracy of Multisensor Systems for Noninvasive Continuous Glucose Monitoring in Diabetes Management","volume":"2013","author":"Zanon","year":"2013","journal-title":"J. Appl. Math."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1177\/1932296817740591","article-title":"First experience with a wearable multisensor device in a noninvasive continuous glucose monitoring study at home, part II: The invesigators\u2019 view","volume":"12","author":"Zanon","year":"2018","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1177\/1932296815579459","article-title":"The Effect of a Global, Subject, and Device-Specific Model on a Noninvasive Glucose Monitoring Multisensor System","volume":"9","author":"Caduff","year":"2015","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1177\/1932296817750932","article-title":"First Experiences with a Wearable Multisensor in an Outpatient Glucose Monitoring Study, Part I: The Users\u2019 View","volume":"12","author":"Caduff","year":"2018","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1406","DOI":"10.1109\/TDEI.2008.4656250","article-title":"Measurement and simulation of conductive dielectric two-layer materials with a multiple electrodes sensor","volume":"15","author":"Dewarrat","year":"2008","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Barrios, L., Oldrati, P., Santini, S., and Lutterotti, A. (2019, January 20\u201323). Evaluating the accuracy of heart rate sensors based on photoplethysmography for in-the-wild analysis. Proceedings of the 13th EAI International Conference on Pervasive Computing Technologies for Healthcare, PervasiveHealth 2019, Trento, Italy.","DOI":"10.1145\/3329189.3329215"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Barrios, L., Santini, S., Oldrati, P., and Lutterit, A. (2018, January 20\u201323). Recognizing Digital Biomarkers for Fatigue Assessment in Patients with Multiple Sclerosis. Proceedings of the 12th EAI International Conference on Pervasive Computing Technologies for Healthcare, New York, NY, USA.","DOI":"10.4108\/eai.20-4-2018.2276340"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1089\/dia.2007.0216","article-title":"How to Assess and Compare the Accuracy of Continuous Glucose Monitors?","volume":"10","author":"Wentholt","year":"2008","journal-title":"Diabetes Technol. Ther."},{"key":"ref_25","unstructured":"(2013). ISO 15197:2013: In Vitro Diagnostic Test Systems\u2013Requirements for Blood-Glucose Monitoring Systems for Self-Testing in Managing Diabetes Mellitus, International Organization for Standardization."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1089\/dia.2005.7.776","article-title":"The Original Clarke Error Grid Analysis (EGA)","volume":"7","author":"Clarke","year":"2005","journal-title":"Diabetes Technol. Ther."},{"key":"ref_27","first-page":"3","article-title":"Continuous glucose monitoring: A review of successes, challenges, and opportunities","volume":"18","author":"Roadbard","year":"2016","journal-title":"Diabetes Technol. Ther."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1177\/1932296818774078","article-title":"Continuous Glucose Monitoring: Current Use in Diabetes Management and Possible Future Applications","volume":"12","author":"Vettoretti","year":"2018","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/24725838.2018.1435431","article-title":"The Wearing Comfort and Acceptability of Ambulatory Physical Activity Monitoring Devices in Soldiers","volume":"6","author":"Beeler","year":"2018","journal-title":"IISE Trans. Occup. Ergon. Hum. Factors"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/17\/3677\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:13:38Z","timestamp":1760188418000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/17\/3677"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,24]]},"references-count":29,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2019,9]]}},"alternative-id":["s19173677"],"URL":"https:\/\/doi.org\/10.3390\/s19173677","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,24]]}}}