{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T03:16:18Z","timestamp":1793762178193,"version":"4.6.1"},"reference-count":70,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2019,9,27]],"date-time":"2019-09-27T00:00:00Z","timestamp":1569542400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The latest studies of the 30-second sit-to-stand (30-STS) test aim to describe it by employing kinematic variables, muscular activity, or fatigue through electromyography (EMG) instead of a number of repetitions. The aim of the present study was to develop a detection system based on acceleration measured using a smartphone to analyze fatigue during the 30-STS test with surface electromyography as the criterion. This case study was carried out on one woman, who performed eight trials. EMG data from the lower limbs and trunk muscles, as well as trunk acceleration were recorded. Both signals from eight trials were preprocessed, being averaged and temporarily aligned. The EMG signal was processed, calculating the spectral centroid (SC) by Discrete Fourier Transform, while the acceleration signal was processed by Discrete Wavelet Transform to calculate its energy percentage. Regarding EMG, fatigue in the vastus medialis of the quadriceps appeared as a decrease in SC, with a descending slope of 12% at second 12, indicating fatigue. However, acceleration analysis showed an increase in the percentage of relative energy, acting like fatigue firing at second 19. This assessed fatigue according to two variables of a different nature. The results will help clinicians to obtain information about fatigue using an accessible and inexpensive device, i.e., as a smartphone.<\/jats:p>","DOI":"10.3390\/s19194202","type":"journal-article","created":{"date-parts":[[2019,9,27]],"date-time":"2019-09-27T11:14:35Z","timestamp":1569582875000},"page":"4202","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Fatigue Detection during Sit-To-Stand Test Based on Surface Electromyography and Acceleration: A Case Study"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7355-9740","authenticated-orcid":false,"given":"Cristina","family":"Rold\u00e1n Jim\u00e9nez","sequence":"first","affiliation":[{"name":"Instituto de Biomedicina de M\u00e1laga (IBIMA), Grupo de Clinimetr\u00eda (F-14); 29010 M\u00e1laga, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Bennett","sequence":"additional","affiliation":[{"name":"School of Clinical Science, Faculty of Health Science, Queensland University Technology, Queensland, Kelvin Grove QLD 4059, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andr\u00e9s","family":"Ortiz Garc\u00eda","sequence":"additional","affiliation":[{"name":"Andr\u00e9s Ortiz, Communications Engineering Department. ETS Ingenier\u00eda de Telecomunicaci\u00f3n. University of M\u00e1laga, 29071 M\u00e1laga, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8880-4315","authenticated-orcid":false,"given":"Antonio I.","family":"Cuesta Vargas","sequence":"additional","affiliation":[{"name":"Instituto de Biomedicina de M\u00e1laga (IBIMA), Grupo de Clinimetr\u00eda (F-14); 29010 M\u00e1laga, Spain"},{"name":"School of Clinical Science, Faculty of Health Science, Queensland University Technology, Queensland, Kelvin Grove QLD 4059, Australia"},{"name":"Department of Physiotherapy. University of Malaga, Faculty of Health Sciences, 29071 Malaga, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,9,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/0021-9290(91)90328-K","article-title":"Mechanics of a constrained chair-rise","volume":"24","author":"Riley","year":"1991","journal-title":"J. Biomech."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1080\/02701367.1999.10608028","article-title":"A 30-s chair-stand test as a measure of lower body strength in community-residing older adults","volume":"70","author":"Jones","year":"1999","journal-title":"Res. Q. Exerc. Sport"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.rehab.2015.04.007","article-title":"Determinants of sit-to-stand tasks in individuals with hemiparesis post stroke: A review","volume":"58","author":"Boukadida","year":"2015","journal-title":"Ann. Phys. Rehabil. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"B144","DOI":"10.1093\/gerona\/57.4.B144","article-title":"Functionally relevant thresholds of quadriceps femoris strength","volume":"57","author":"Manini","year":"2002","journal-title":"J. Gerontol. A Biol. Sci. Med. Sci."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1016\/S0003-9993(95)80550-8","article-title":"Trunk movements in older subjects during sit-to-stand","volume":"76","author":"Baer","year":"1995","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/0966-6362(94)90006-X","article-title":"Standardization and definitions of the sit-stand-sit movement cycle","volume":"2","author":"Kerr","year":"1994","journal-title":"Gait Posture"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/0966-6362(94)90005-1","article-title":"Analysis of the sit-stand-sit movement cycle: Development of a measurement system","volume":"2","author":"Kerr","year":"1994","journal-title":"Gait Posture"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1366","DOI":"10.1016\/j.apmr.2014.02.016","article-title":"Health-related physical fitness measures: Reference values and reference equations for use in clinical practice","volume":"95","author":"Tveter","year":"2014","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1682\/JRRD.2006.11.0146","article-title":"Self-reported chair-rise ability relates to stair-climbing readiness of total knee arthroplasty patients: A pilot study","volume":"44","author":"Nyland","year":"2007","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1109\/TNSRE.2014.2331895","article-title":"Kinematic parameters to evaluate functional performance of sit-to-stand and stand-to-sit transitions using motion sensor devices: A systematic review","volume":"22","author":"Millor","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1007\/s11517-007-0224-8","article-title":"Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects","volume":"45","author":"Giansanti","year":"2007","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1007\/s11517-008-0366-3","article-title":"Validity of accelerometry in assessing the duration of the sit-to-stand movement","volume":"46","author":"Janssen","year":"2008","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1186\/1743-0003-10-86","article-title":"An evaluation of the 30-s chair stand test in older adults: Frailty detection based on kinematic parameters from a single inertial unit","volume":"10","author":"Millor","year":"2013","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_14","first-page":"3063","article-title":"An instrumented sit-to-stand test used to examine differences between older fallers and non-fallers","volume":"2011","author":"Doheny","year":"2011","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.gaitpost.2012.10.008","article-title":"Automated approach for quantifying the repeated sit-to-stand using one body fixed sensor in young and older adults","volume":"38","author":"Ainsworth","year":"2013","journal-title":"Gait Posture"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1109\/JBHI.2013.2238243","article-title":"Automatic evaluation of the 30-s chair stand test using inertial\/magnetic-based technology in an older prefrail population","volume":"17","author":"Millor","year":"2013","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.gaitpost.2009.04.002","article-title":"Muscles limiting the sit-to-stand movement: An experimental simulation of muscle weakness","volume":"30","author":"Meijer","year":"2009","journal-title":"Gait Posture"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1016\/j.gaitpost.2012.05.002","article-title":"Kinematic and electromyographic analyses of normal and device-assisted sit-to-stand transfers","volume":"36","author":"Burnfield","year":"2012","journal-title":"Gait Posture"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1446","DOI":"10.1016\/j.jelekin.2013.06.001","article-title":"Analysis of the neuromuscular activity during rising from a chair in water and on dry land","volume":"23","author":"Heywood","year":"2013","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1109\/10.930899","article-title":"Time-frequency parameters of the surface myoelectric signal for assessing muscle fatigue during cyclic dynamic contractions","volume":"48","author":"Bonato","year":"2001","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1383","DOI":"10.1109\/TBME.2004.827556","article-title":"Assessment of average muscle fiber conduction velocity from surface EMG signals during fatiguing dynamic contractions","volume":"51","author":"Farina","year":"2004","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"3545","DOI":"10.3390\/s110403545","article-title":"A review of non-invasive techniques to detect and predict localised muscle fatigue","volume":"11","author":"Sepulveda","year":"2011","journal-title":"Sensors"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/j.neucom.2015.06.002","article-title":"Hybrid BF\u2013PSO and fuzzy support vector machine for diagnosis of fatigue status using EMG signal features","volume":"173","author":"Wu","year":"2016","journal-title":"Neurocomputing"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1097\/00003677-200101000-00005","article-title":"Surface electromyography for noninvasive characterization of muscle","volume":"29","author":"Merletti","year":"2001","journal-title":"Exerc. Sport Sci. Rev."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.clinph.2007.09.126","article-title":"Clinical neurophysiology of fatigue","volume":"119","author":"Zwarts","year":"2008","journal-title":"Clin. Neurophysiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1212\/WNL.0b013e31827f07be","article-title":"Fatigue and fatigability in neurologic illnesses: Proposal for a unified taxonomy","volume":"80","author":"Kluger","year":"2013","journal-title":"Neurology"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"S263","DOI":"10.1002\/acr.20579","article-title":"Measures of fatigue: Bristol Rheumatoid Arthritis Fatigue Multi-Dimensional Questionnaire (BRAF MDQ), Bristol Rheumatoid Arthritis Fatigue Numerical Rating Scales (BRAF NRS) for severity, effect, and coping, Chalder Fatigue Questionnaire (CFQ), Checklist Individual Strength (CIS20R and CIS8R), Fatigue Severity Scale (FSS), Functional Assessment Chronic Illness Therapy (Fatigue) (FACIT-F), Multi-Dimensional Assessment of Fatigue (MAF), Multi-Dimensional Fatigue Inventory (MFI), Pediatric Quality Of Life (PedsQL) Multi-Dimensional Fatigue Scale, Profile of Fatigue (ProF), Short Form 36 Vitality Subscale (SF-36 VT), and Visual Analog Scales (VAS)","volume":"63","author":"Hewlett","year":"2011","journal-title":"Arthritis Care Res. (Hoboken)"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1007\/BF00421697","article-title":"Signal characteristics of EMG during fatigue","volume":"37","author":"Viitasalo","year":"1977","journal-title":"Eur. J. Appl. Physiol. Occup. Physiol."},{"key":"ref_29","first-page":"459","article-title":"Functional characteristics of human skeletal muscle revealed by spectral analysis of the surface electromyogram","volume":"22","author":"Sato","year":"1982","journal-title":"Electromyogr. Clin. Neurophysiol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/BF00421098","article-title":"The influence of temperature on the amplitude and frequency components of the EMG during brief and sustained isometric contractions","volume":"44","author":"Petrofsky","year":"1980","journal-title":"Europ. J. Appl. Physiol."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Phinyomark, A., Thongpanja, S., Hu, H., Phukpattaranont, P., and Limsakul, C. (2012). The Usefulness of Mean and Median Frequencies in Electromyography Analysis. Computational Intelligence in Electromyography Analysis\u2014A Perspective on Current Applications and Future Challenges, Intech.","DOI":"10.5772\/50639"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Rold\u00e1n-Jim\u00e9nez, C., Bennett, P., and Cuesta-Vargas, A.I. (2015). Muscular Activity and Fatigue in Lower-Limb and Trunk Muscles during Different Sit-To-Stand Tests. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0141675"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Kimura, J. (2013). Electrodiagnosis in Diseases of Nerve and Muscle: Principles and Practice, Oxford University Press.","DOI":"10.1093\/med\/9780199738687.001.0001"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/j.jsams.2011.05.001","article-title":"Knee and hip sagittal and transverse plane changes after two fatigue protocols","volume":"14","author":"Lucci","year":"2011","journal-title":"J. Sci. Med. Sport"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1080\/02640414.2012.671528","article-title":"A functional agility short-term fatigue protocol changes lower extremity mechanics","volume":"30","author":"Cortes","year":"2012","journal-title":"J. Sports Sci."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1109\/TNSRE.2013.2291327","article-title":"Human movement analysis as a measure for fatigue: A hidden Markov-based approach","volume":"22","author":"Karg","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1016\/j.gaitpost.2013.11.020","article-title":"Differential effects of fatigue on movement variability","volume":"39","author":"Cortes","year":"2014","journal-title":"Gait Posture"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1109\/51.982285","article-title":"EMG-based measures of fatigue during a repetitive squat exercise","volume":"20","author":"Bonato","year":"2001","journal-title":"IEEE Eng. Med. Biol. Mag."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/j.gaitpost.2009.11.003","article-title":"A body-fixed-sensor-based analysis of power during sit-to-stand movements","volume":"31","author":"Zijlstra","year":"2010","journal-title":"Gait Posture"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.1249\/MSS.0b013e318213f880","article-title":"Velocity loss as an indicator of neuromuscular fatigue during resistance training","volume":"43","year":"2011","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1080\/14763141.2016.1159321","article-title":"Fatigue detection in strength training using three-dimensional accelerometry and principal component analysis","volume":"15","author":"Brown","year":"2016","journal-title":"Sports Biomech."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1007\/s40520-015-0495-0","article-title":"Assessment of fatigability of older women during sit-to-stand performance","volume":"28","author":"Lindemann","year":"2015","journal-title":"Aging Clin. Exp. Res."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Barbero, M., Merletti, R., and Rainoldi, A. (2012). Atlas of Muscle Innervation Zones: Understanding Surface Electromyography and Its Applications, Springer.","DOI":"10.1007\/978-88-470-2463-2"},{"key":"ref_44","unstructured":"Perotto, A.O., Delagi, E.F., Lanzetti, J., and Morrison, D. (2005). Anatomical Guide for the Electromyographer: The Limbs and Trunk, Charles C Thomas Publisher. [6th ed.]."},{"key":"ref_45","unstructured":"Daniels, L., and Worthingham, C. (1995). Muscle Testing: Techniques of Manual Examination, Saunders."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1186\/1475-925X-13-156","article-title":"Reliability and criterion-related validity with a smartphone used in timed-up-and-go test","volume":"13","year":"2014","journal-title":"Biomed. Eng. Online"},{"key":"ref_47","unstructured":"Chicharro, J.L., and Vaquero, A.F. (2006). Fisiologia del Ejercicio, Ed. M\u00e9dica Panamericana."},{"key":"ref_48","first-page":"175","article-title":"Some properties of median nerve frequency of the myoelectric signal during localized muscular fatigue","volume":"13","author":"Sabbahi","year":"1982","journal-title":"Biochem. Excercise Hum. Kinet. Inc"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/S0268-0033(02)00033-5","article-title":"The relationship between EMG median frequency and low frequency band amplitude changes at different levels of muscle capacity","volume":"17","author":"Allison","year":"2002","journal-title":"Clin. Biomech. (Bristol Avon)"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1007\/BF00421637","article-title":"Median frequency of the myoelectric signal. Effects of hand dominance","volume":"55","author":"Sabbahi","year":"1986","journal-title":"Eur. J. Appl. Physiol. Occup. Physiol."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Ma\u2019as, M.D.F., and Azmi, A.Z.U. (2017, January 9\u201311). Real-time muscle fatigue monitoring based on median frequency of electromyography signal. Proceedings of the 2017 5th International Conference on Instrumentation, Control, and Automation (ICA), Yogyakarta, Indonesia.","DOI":"10.1109\/ICA.2017.8068428"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Chiang, S., Vankov, E.R., Yeh, H.J., Guindani, M., Vannucci, M., Haneef, Z., and Stern, J.M. (2018). Temporal and spectral characteristics of dynamic functional connectivity between resting-state networks reveal information beyond static connectivity. PLoS ONE, 13.","DOI":"10.1371\/journal.pone.0190220"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1721","DOI":"10.3390\/s110201721","article-title":"Leg motion classification with artificial neural networks using wavelet-based features of gyroscope signals","volume":"11","author":"Barshan","year":"2011","journal-title":"Sensors (Basel)"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1123\/jab.2015-0291","article-title":"Muscle Forces and Their Contributions to Vertical and Horizontal Acceleration of the Center of Mass during Sit-to-Stand Transfer in Young, Healthy Adults","volume":"32","author":"Caruthers","year":"2016","journal-title":"J. Appl. Biomech."},{"key":"ref_55","first-page":"315","article-title":"Manifestation of fatigue in myoelectric signals of dynamic contractions produced during playing PC games","volume":"2008","author":"Hu","year":"2008","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Al-Mulla, M.R., Sepulveda, F., Colley, M., and Al-Mulla, F. (2009, January 17\u201319). Statistical Class Separation Using sEMG Features towards Automated Muscle Fatigue Detection and Prediction. Proceedings of the 2nd International Congress on Image and Signal Processing, Tianjin, China.","DOI":"10.1109\/CISP.2009.5304091"},{"key":"ref_57","unstructured":"Basmajian, J.V., and De Luca, C.J. (1985). Muscles Alive: Their Functions Revealed by Electromyography, Williams & Wilkins. [5 Sub ed.]."},{"key":"ref_58","unstructured":"Voge, K., and Dingwell, J. (2003, January 17\u201321). Relative timing of changes in muscle fatigue and movement coordination during a repetitive one-hand lifting task. Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439), Cancun, Mexico."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1139\/h04-019","article-title":"Force maintenance with submaximal fatiguing contractions","volume":"29","author":"Behm","year":"2004","journal-title":"Can. J. Appl. Physiol."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"1753","DOI":"10.1152\/japplphysiol.00314.2002","article-title":"Nonlinear surface EMG analysis to detect changes of motor unit conduction velocity and synchronization","volume":"93","author":"Farina","year":"2002","journal-title":"J. Appl. Physiol."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"1634","DOI":"10.1016\/S1388-2457(99)00109-1","article-title":"Patterned electromyographic activity in the sit-to-stand movement","volume":"110","author":"Goulart","year":"1999","journal-title":"Clin. Neurophysiol."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1016\/j.clinbiomech.2007.07.015","article-title":"Kinematic and electromyographic analysis of rising from a chair during a \u201cSit-to-Walk\u201d task in elderly subjects: Role of strength","volume":"22","author":"Dehail","year":"2007","journal-title":"Clin. Biomech. (Bristol Avon)"},{"key":"ref_63","unstructured":"Donatelli, R. (2007). Sports-Specific Rehabilitation, Elsevier Health Sciences."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.gaitpost.2008.07.003","article-title":"Effect of lower limb muscle fatigue induced by high-level isometric contractions on postural maintenance and postural adjustments associated with bilateral forward-reach task","volume":"29","author":"Yiou","year":"2009","journal-title":"Gait Posture"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1111\/apha.12234","article-title":"Sex Differences in Human Fatigability: Mechanisms and Insight to Physiological Responses","volume":"210","author":"Hunter","year":"2014","journal-title":"Acta Physiol. (Oxf.)"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1007\/s00421-006-0206-9","article-title":"Age-related fatigability of the ankle dorsiflexor muscles during concentric and eccentric contractions","volume":"100","author":"Baudry","year":"2006","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1016\/S0268-0033(03)00144-X","article-title":"Biomechanical analysis of sit-to-stand movement in normal and obese subjects","volume":"18","author":"Sibella","year":"2003","journal-title":"Clin. Biomech. (Bristol Avon)"},{"key":"ref_68","unstructured":"Shumway-Cook, A., and Woollacott, M.H. (2011). Motor Control: Translating Research into Clinical Practice, Lippincott Raven. [4th ed.]."},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Cuesta-Vargas, A., Buchan, J., Pajares, B., Alba, E., and Roldan-Jim\u00e9nez, C. (2019). Cancer-related fatigue stratification system based on patient-reported outcomes and objective outcomes: A cancer-related fatigue ambulatory index. PLoS ONE, 14.","DOI":"10.1371\/journal.pone.0215662"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1007\/s11136-012-0134-6","article-title":"FibroQoL Study Group Clinical dimensions of fibromyalgia symptoms and development of a combined index of severity: The CODI index","volume":"22","author":"Luciano","year":"2013","journal-title":"Qual. Life Res."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/19\/4202\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:25:15Z","timestamp":1760189115000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/19\/4202"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,9,27]]},"references-count":70,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2019,10]]}},"alternative-id":["s19194202"],"URL":"https:\/\/doi.org\/10.3390\/s19194202","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,9,27]]}}}