{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T05:33:45Z","timestamp":1793856825331,"version":"4.6.1"},"reference-count":64,"publisher":"MDPI AG","issue":"21","license":[{"start":{"date-parts":[[2019,11,5]],"date-time":"2019-11-05T00:00:00Z","timestamp":1572912000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005416","name":"Norges Forskningsr\u00e5d","doi-asserted-by":"publisher","award":["247689"],"award-info":[{"award-number":["247689"]}],"id":[{"id":"10.13039\/501100005416","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Comparing and selecting an adequate spectral filter array (SFA) camera is application-specific and usually requires extensive prior measurements. An evaluation framework for SFA cameras is proposed and three cameras are tested in the context of skin analysis. The proposed framework does not require application-specific measurements and spectral sensitivities together with the number of bands are the main focus. An optical model of skin is used to generate a specialized training set to improve spectral reconstruction. The quantitative comparison of the cameras is based on reconstruction of measured skin spectra, colorimetric accuracy, and oxygenation level estimation differences. Specific spectral sensitivity shapes influence the results directly and a 9-channel camera performed best regarding the spectral reconstruction metrics. Sensitivities at key wavelengths influence the performance of oxygenation level estimation the strongest. The proposed framework allows to compare spectral filter array cameras and can guide their application-specific development.<\/jats:p>","DOI":"10.3390\/s19214805","type":"journal-article","created":{"date-parts":[[2019,11,5]],"date-time":"2019-11-05T06:47:57Z","timestamp":1572936477000},"page":"4805","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["An Evaluation Framework for Spectral Filter Array Cameras to Optimize Skin Diagnosis"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8063-7495","authenticated-orcid":false,"given":"Jacob Renzo","family":"Bauer","sequence":"first","affiliation":[{"name":"The Norwegian Colour and Visual Computing Laboratory, Norwegian University of Science and Technology (NTNU), 2815 Gj\u00f8vik, Norway"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Baptiste","family":"Thomas","sequence":"additional","affiliation":[{"name":"The Norwegian Colour and Visual Computing Laboratory, Norwegian University of Science and Technology (NTNU), 2815 Gj\u00f8vik, Norway"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jon Yngve","family":"Hardeberg","sequence":"additional","affiliation":[{"name":"The Norwegian Colour and Visual Computing Laboratory, Norwegian University of Science and Technology (NTNU), 2815 Gj\u00f8vik, Norway"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rudolf M.","family":"Verdaasdonk","sequence":"additional","affiliation":[{"name":"Biomedical Photonics and Imaging group, Faculty of Science and Technology, University of Twente, 7522NB Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,11,5]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"21626","DOI":"10.3390\/s141121626","article-title":"Multispectral filter arrays: Recent advances and practical implementation","volume":"14","author":"Lapray","year":"2014","journal-title":"Sensors"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Ewerl\u00f6f, M., Larsson, M., and Salerud, E.G. (2017). Spatial and temporal skin blood volume and saturation estimation using a multispectral snapshot imaging camera. Proc. SPIE.","DOI":"10.1117\/12.2251928"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Thomas, J.B., Lapray, P.J., Gouton, P., and Clerc, C. (2016). Spectral Characterization of a Prototype SFA Camera for Joint Visible and NIR Acquisition. Sensors, 16.","DOI":"10.3390\/s16070993"},{"key":"ref_4","unstructured":"Ximea (2018, December 02). Hyperspectral Cameras. Available online: https:\/\/www.ximea.com."},{"key":"ref_5","unstructured":"IMEC (2018, December 02). Hyperspectral-Imaging. Available online: https:\/\/www.imec-int.com."},{"key":"ref_6","unstructured":"SILIOS (2018, December 02). Multispectral-Imaging. Available online: https:\/\/www.silios.com."},{"key":"ref_7","first-page":"1","article-title":"Full-reference image quality metrics: Classification and evaluation","volume":"7","author":"Pedersen","year":"2012","journal-title":"Found. Trends\u00ae Comput. Graph. Vis."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1109\/TIP.2003.819861","article-title":"Image Quality Assessment: From Error Visibility to Structural Similarity","volume":"13","author":"Wang","year":"2004","journal-title":"IEEE Trans. Image Process."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2013\/905685","article-title":"Seven Challenges in Image Quality Assessment: Past, Present, and Future Research","volume":"2013","author":"Chandler","year":"2013","journal-title":"ISRN Signal Process."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Miao, L., Qi, H., Ramanath, R., and Snyder, W.E. (2006). Binary tree-based generic demosaicking algorithm for multispectral filter arrays. IEEE Trans. Image Process., 15.","DOI":"10.1109\/TIP.2006.877476"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Monno, Y., Tanaka, M., and Okutomi, M. (2011, January 11\u201314). Multispectral demosaicking using adaptive kernel upsampling. Proceedings of the 2011 18th IEEE International Conference on Image Processing, Brussels, Belgium.","DOI":"10.1109\/ICIP.2011.6116337"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Wang, C., Wang, X., and Hardeberg, J.Y. (2014). A Linear Interpolation Algorithm for Spectral Filter Array Demosaicking. Image and Signal Processing, Springer International Publishing.","DOI":"10.1007\/978-3-319-07998-1_18"},{"key":"ref_13","unstructured":"Wang, X., Thomas, J.B., Hardeberg, J.Y., and Gouton, P. (2013, January 8\u201312). A Study on the Impact of Spectral Characteristics of Filters on Multispectral Image Acquisition. Proceedings of the 12th Congress of the International Colour Association, Newcastle Gateshead, UK."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Park, C., and Kang, M. (2016). Color Restoration of RGBN Multispectral Filter Array Sensor Images Based on Spectral Decomposition. Sensors, 16.","DOI":"10.3390\/s16050719"},{"key":"ref_15","unstructured":"Nazari, R.M. (2017). Denoising and Demosaicking of Color Images. [Ph.D. Thesis, Universit\u00e9 d\u2019Ottawa\/University of Ottawa]."},{"key":"ref_16","unstructured":"Bersha, K.S. (2010). Spectral Imaging and Analysis of Human Skin. [Master\u2019s Thesis, University of Estern Finland]."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"060502","DOI":"10.1117\/1.3584846","article-title":"Towards noncontact skin melanoma selection by multispectral imaging analysis","volume":"16","author":"Kuzmina","year":"2011","journal-title":"J. Biomed. Opt."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"086012","DOI":"10.1117\/1.3613929","article-title":"Noninvasive imaging of human skin hemodynamics using a digital red-green-blue camera","volume":"16","author":"Nishidate","year":"2011","journal-title":"J. Biomed. Opt."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"50","DOI":"10.3952\/physics.v52i1.2267","article-title":"RGB imaging device for mapping and monitoring of hemoglobin distribution in skin","volume":"52","author":"Jakovels","year":"2012","journal-title":"Lith. J. Phys."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"842737","DOI":"10.1117\/12.922432","article-title":"RGB imaging system for monitoring of skin vascular malformation\u2019s laser therapy","volume":"8427","author":"Jakovels","year":"2012","journal-title":"Proc. SPIE"},{"key":"ref_21","unstructured":"Kumar, A., Dhawan, A.P., Relue, P., and Chaudhuri, P.K. (1999, January 13\u201316). Multi-spectral optical imaging of skin to diagnose malignant melanoma. Proceedings of the Engineering in Medicine and Biology, Atlanta, GA, USA."},{"key":"ref_22","unstructured":"Cotton, S., Claridge, E., and Hall, P. (1999, January 19\u201320th). A skin imaging method based on a colour formation model and its application to the diagnosis of pigmented skin lesions. Proceedings of the Medical Image Understanding and Analysis, BMVA, Oxford, UK."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"81","DOI":"10.2352\/CIC.2000.8.1.art00016","article-title":"Mapping Pigmentation in Human Skin by Multi-Visible-Spectral Imaging by Inverse Optical Scattering Technique","volume":"2000","author":"Tsumura","year":"2000","journal-title":"Color Imaging Conf."},{"key":"ref_24","unstructured":"Balas, C., Themelis, G., Papadakis, A., and Vasgiouraki, E. (2001, January 14). A novel hyper-spectral imaging system: Application on in-vivo detection and grading of cervical precancers and of pigmented skin lesions. Proceedings of the IEEE Computer Society Workshop on Computer Vision Beyond the Visible Spectrum, Kauai, HI, USA."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"61423V","DOI":"10.1117\/12.655756","article-title":"Spectral imaging of skin: Experimental observations and analyses","volume":"6142","author":"Kerekes","year":"2006","journal-title":"Proc. SPIE"},{"key":"ref_26","first-page":"6078","article-title":"Hyperspectral imaging of bruised skin","volume":"6078","author":"Randeberg","year":"2006","journal-title":"Proc. SPIE"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Klaessens, J.H.G.M., Noordmans, H.J., de Roode, R., and Verdaasdonk, R.M. (2009). Non-invasive skin oxygenation imaging using a multi-spectral camera system: Effectiveness of various concentration algorithms applied on human skin. Proc. SPIE, 7174.","DOI":"10.1117\/12.808707"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Spigulis, J., Jakovels, D., and Rubins, U. (2010). Multi-spectral skin imaging by a consumer photo-camera. Proc. SPIE, 7557.","DOI":"10.1117\/12.845492"},{"key":"ref_29","unstructured":"Huang, J. (2013). Multispectral Imaging of Skin Oxygenation. [Ph.D. Thesis, The Ohio State University]."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"89510X","DOI":"10.1117\/12.2038571","article-title":"Pilot study to visualise and measure skin tissue oxygenation, erythema, total haemoglobin and melanin content using index maps in healthy controls","volume":"8951","author":"Poxon","year":"2014","journal-title":"Proc. SPIE"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"38609","DOI":"10.1038\/srep38609","article-title":"New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring","volume":"6","author":"Stuijk","year":"2016","journal-title":"Sci. Rep."},{"key":"ref_32","unstructured":"Bauer, J.R., van Beekum, K., Klaessens, J.H.G.M., Noordmans, H.J., Boer, C., Hardeberg, J.Y., and Verdaasdonk, R.M. (2018). Towards real-time non contact spatial resolved oxygenation monitoring using a multi spectral filter array camera in various light conditions. Proc. SPIE, 10489."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1109\/TPAMI.2004.36","article-title":"Spectral filter optimization for the recovery of parameters which describe human skin","volume":"26","author":"Preece","year":"2004","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Guti\u00e9rrez-Guti\u00e9rrez, J., Pardo, A., Real, E., L\u00f3pez-Higuera, J., and Conde, O.M. (2019). Custom Scanning Hyperspectral Imaging System for Biomedical Applications: Modeling, Benchmarking, and Specifications. Sensors, 19.","DOI":"10.3390\/s19071692"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1117\/1.JBO.23.4.046002","article-title":"Method using in vivo quantitative spectroscopy to guide design and optimization of low-cost, compact clinical imaging devices: Emulation and evaluation of multispectral imaging systems","volume":"23","author":"Saager","year":"2018","journal-title":"J. Biomed. Opt."},{"key":"ref_36","first-page":"141:1","article-title":"A practical appearance model for dynamic facial color","volume":"29","author":"Jimenez","year":"2010","journal-title":"ACM Trans. Graph. (Proc. SIGGRAPH Asia)"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1111\/cgf.12540","article-title":"A Biophysically-Based Model of the Optical Properties of Skin Aging","volume":"34","author":"Aliaga","year":"2015","journal-title":"Comput. Graph. Forum"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Lapray, P.J., Thomas, J.B., and Gouton, P. (2017). High Dynamic Range Spectral Imaging Pipeline For Multispectral Filter Array Cameras. Sensors, 17.","DOI":"10.3390\/s17061281"},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Delgado Atencio, J.A., Jacques, S.L., and Montiel, S.V. (2011). Monte Carlo Modeling of Light Propagation in Neonatal Skin, InTech.","DOI":"10.5772\/15853"},{"key":"ref_40","unstructured":"Hiltunen, J. (2018, December 02). Munsell Book of Color: Matte Finish Collection Measured by J. Hiltunen. Available online: https:\/\/www.uef.fi\/web\/spectral\/munsell-colors-matt-spectrofotometer-measured."},{"key":"ref_41","unstructured":"Munsell Color (1976). Munsell Book of Color: Matte Finish Collection, Munsell Color."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1","DOI":"10.6028\/jres.122.026","article-title":"Reference Data Set of Human Skin Reflectance","volume":"122","author":"Cooksey","year":"2017","journal-title":"J. Res. Natl. Inst. Stand. Technol."},{"key":"ref_43","unstructured":"Publication, CIE (2004). CIE 15: Technical Report: Colorimetry, CIE Cent. Bur.. [3rd ed.]."},{"key":"ref_44","unstructured":"Hardeberg, J.Y. (1999). Acquisition and Reproduction of Color Images: Colorimetric and Multispectral Approaches. [Ph.D. Thesis, Ecole Nationale Sup\u00e9rieure des T\u00e9l\u00e9communications]."},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Imai, F.H., and Berns, R.S. (1999, January 21\u201322). Spectral estimation using trichromatic digital cameras. Proceedings of the International Symposium on Multispectral Imaging and Color Reproduction for Digital Archives, Chiba, Japan.","DOI":"10.2352\/CIC.1999.7.1.art00005"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"3211","DOI":"10.1364\/JOSAA.24.003211","article-title":"Recovery of spectral reflectances of objects being imaged by multispectral cameras","volume":"24","author":"Shimano","year":"2007","journal-title":"J. Opt. Soc. Am. A"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1364\/JOSAA.27.000251","article-title":"Recovery of spectral reflectances of imaged objects by the use of features of spectral reflectances","volume":"27","author":"Shimano","year":"2010","journal-title":"J. Opt. Soc. Am. A"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1134\/S1054661807020101","article-title":"Wiener estimation method in estimating of spectral reflectance from RGB images","volume":"17","author":"Stigell","year":"2007","journal-title":"Pattern Recognit. Image Anal."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"7902","DOI":"10.3390\/s130607902","article-title":"Estimation of Melanin and Hemoglobin Using Spectral Reflectance Images Reconstructed from a Digital RGB Image by the Wiener Estimation Method","volume":"13","author":"Nishidate","year":"2013","journal-title":"Sensors"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"2444","DOI":"10.1364\/JOSAA.25.002444","article-title":"Evaluation and unification of some methods for estimating reflectance spectra from RGB images","volume":"25","author":"Heikkinen","year":"2008","journal-title":"J. Opt. Soc. Am. A"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s41476-016-0031-7","article-title":"Energy balance in Spectral Filter Array camera design","volume":"13","author":"Lapray","year":"2017","journal-title":"J. Eur. Opt. Soc.-Rapid Publ."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Thomas, J.B. (2015, January 25\u201326). Illuminant estimation from uncalibrated multispectral images. Proceedings of the 2015 Colour and Visual Computing Symposium (CVCS), Gj\u00f8vik, Norway.","DOI":"10.1109\/CVCS.2015.7274900"},{"key":"ref_53","first-page":"44","article-title":"Multispectral imaging: Narrow or wide band filters?","volume":"12","author":"Wang","year":"2014","journal-title":"JAIC J. Int. Colour Assoc."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1364\/JOSAA.34.001085","article-title":"Illuminant estimation in multispectral imaging","volume":"34","author":"Khan","year":"2017","journal-title":"J. Opt. Soc. Am. A"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1117\/12.538045","article-title":"Optical classification of bruises","volume":"5312","author":"Randeberg","year":"2004","journal-title":"Proc. SPIE"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Humphreys, K., Ward, T., and Markham, C. (2006, January 17\u201318). A CMOS camera-based pulse oximetry imaging system. Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, Shanghai, China.","DOI":"10.1109\/IEMBS.2005.1617232"},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"Kong, L., Yi, D., Sprigle, S., Wang, F., Wang, C., Liu, F., Adibi, A., and Tummala, R. (2010). Single sensor that outputs narrowband multispectral images. J. Biomed. Opt., 15.","DOI":"10.1117\/1.3277669"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"091508","DOI":"10.1117\/1.JBO.22.9.091508","article-title":"Smartphone snapshot mapping of skin chromophores under triple-wavelength laser illumination","volume":"22","author":"Spigulis","year":"2017","journal-title":"J. Biomed. Opt."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Bauer, J.R., Bruins, A.A., Hardeberg, J.Y., and Verdaasdonk, R.M. (2019). A Spectral Filter Array Camera for Clinical Monitoring and Diagnosis: Proof of Concept for Skin Oxygenation Imaging. J. Imaging, 5.","DOI":"10.3390\/jimaging5080066"},{"key":"ref_60","unstructured":"Day, D. (2003). Spectral Sensitivities of the Sinarback 54 Camera, Munsell Color Science Laboratory, Chester F. Carlson Center for Imaging Science, Rochester Institute of Technology. Technical Report."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"165","DOI":"10.2352\/ISSN.2169-2629.2017.25.165","article-title":"Skin color simulation - review and analysis of available Monte Carlo-based photon transport simulation models","volume":"2017","author":"Bauer","year":"2017","journal-title":"Color Imaging Conf."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1364\/AOIPM.1996.OPC364","article-title":"Origins of tissue optical properties in the UVA, visible, and NIR regions","volume":"2","author":"Jacques","year":"1996","journal-title":"Adv Opt Imaging Photon Migr."},{"key":"ref_63","unstructured":"Jacques, S.L., and Prahl, S.A. (2018, December 02). A Collaboration of Oregon Health & Science University, Portland State University, and the Oregon Institute of Technology. Optical Spectra. Available online: https:\/\/www.omlc.org."},{"key":"ref_64","unstructured":"IEC (1999). International Standard: International Electrotechnical Commission, IEC. IEC 61966-2-1:1999."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/21\/4805\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:32:00Z","timestamp":1760189520000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/21\/4805"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,5]]},"references-count":64,"journal-issue":{"issue":"21","published-online":{"date-parts":[[2019,11]]}},"alternative-id":["s19214805"],"URL":"https:\/\/doi.org\/10.3390\/s19214805","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,5]]}}}