{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T12:06:40Z","timestamp":1771330000298,"version":"3.50.1"},"reference-count":33,"publisher":"MDPI AG","issue":"23","license":[{"start":{"date-parts":[[2019,11,26]],"date-time":"2019-11-26T00:00:00Z","timestamp":1574726400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["51475067"],"award-info":[{"award-number":["51475067"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Open Fund of State-key Laboratory of Tractions Power","award":["TPL1801"],"award-info":[{"award-number":["TPL1801"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The ultrasonic guided wave-based structural damage diagnosis method has broad application prospects in different fields. However, some environmental factors such as temperature and loads will significantly affect the monitoring results. In this paper, a reference matching-based temperature compensation for ultrasonic guided wave signals is proposed to eliminate the effect of temperature. Firstly, the guided wave signals measured at different temperatures are used as reference signals to establish the relationship between the features of the reference signals and temperature. Then the matching algorithm based on Gabor function is used to establish the relationship between the amplitude influence coefficient obtained by the reference signal and the corresponding temperature. Finally, through these two relationships, the values of the phase and amplitude influence coefficients of the guided wave signals at other temperatures are obtained in a way of interpolation in order to reconstruct the compensation signals at the temperature. The effect of temperature on the amplitude and phase of the guided wave signal is eliminated. The proposed temperature compensation method is featured such that the compensation performance can be improved by multiple iteration compensation of the residual signal. The ultrasonic guided wave test results at different temperatures show that the first iterative compensation of the proposed method can achieve compensation within the temperature range greater than 7 \u00b0C, and the compensation within the temperature range greater than 18 \u00b0C can be achieved after three iterations.<\/jats:p>","DOI":"10.3390\/s19235174","type":"journal-article","created":{"date-parts":[[2019,11,26]],"date-time":"2019-11-26T10:57:27Z","timestamp":1574765847000},"page":"5174","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["A Reference Matching-Based Temperature Compensation Method for Ultrasonic Guided Wave Signals"],"prefix":"10.3390","volume":"19","author":[{"given":"Geng","family":"Wang","sequence":"first","affiliation":[{"name":"School of Aerospace Engineering, Xiamen University, Xiamen 361005, China"}]},{"given":"Yuhang","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Aerospace Engineering, Xiamen University, Xiamen 361005, China"},{"name":"College of Mechanical and Automotive Engineering, Zhaoqing University, Zhaoqing 526061, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4272-3552","authenticated-orcid":false,"given":"Hu","family":"Sun","sequence":"additional","affiliation":[{"name":"School of Aerospace Engineering, Xiamen University, Xiamen 361005, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9909-3873","authenticated-orcid":false,"given":"Bingrong","family":"Miao","sequence":"additional","affiliation":[{"name":"State-key Laboratory of Traction Power, Southwest Jiaotong University, Chengdu 610031, China"}]},{"given":"Yishou","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Aerospace Engineering, Xiamen University, Xiamen 361005, China"}]}],"member":"1968","published-online":{"date-parts":[[2019,11,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/0041-624X(96)00024-8","article-title":"The use of Lamb waves for the long range inspection of large structures","volume":"34","author":"Cawley","year":"1996","journal-title":"Ultrasonics"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Qing, X., Li, W., Wang, Y., and Sun, H. (2019). Piezoelectric transducer-based structural health monitoring for aircraft applications. Sensors, 19.","DOI":"10.3390\/s19030545"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"14","DOI":"10.4028\/www.scientific.net\/KEM.270-273.14","article-title":"Ultrasonic Guided Waves in Structural Health Monitoring","volume":"270","author":"Rose","year":"2004","journal-title":"Key Eng. Mater."},{"key":"ref_4","first-page":"3199","article-title":"Opportunities and challenges of aircraft structural health monitoring","volume":"35","author":"Sun","year":"2014","journal-title":"Acta Aeronaut. Astronaut. Sin."},{"key":"ref_5","first-page":"62","article-title":"Challenge in structural health monitoring of large aircraft development","volume":"22","author":"Yuan","year":"2009","journal-title":"Aeronaut. Manuf. Technol."},{"key":"ref_6","first-page":"517","article-title":"Structural health monitoring technology and its application in aeronautics and astronautics","volume":"27","author":"Qing","year":"2012","journal-title":"J. Exp. Mech."},{"key":"ref_7","first-page":"397","article-title":"Damage detection and identification for composites based on Lamb waves and time-frequency analysis method","volume":"39","author":"Yan","year":"2007","journal-title":"J. Nanjing Univ. Aeronaut. Astronaut."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1177\/1475921713479643","article-title":"A quan-titative multidamage monitoring method for large-scale complex composite","volume":"12","author":"Qiu","year":"2013","journal-title":"Struct. Health Monit."},{"key":"ref_9","first-page":"1815","article-title":"Lamb wave high-resolution damage imaging method based on non-dispersive signal construction","volume":"34","author":"Jian","year":"2013","journal-title":"Acta Aeronaut. Astronaut. Sin."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Michaels, J.E., Lee, S.J., and Michaels, T.E. (2010, January 18\u201323). Impact of applied loads on guided wave structural health monitoring. Proceedings of the AIP Conference, San Diego, CA, USA.","DOI":"10.1063\/1.3592110"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Lee, S.J., Gandhi, N., Michaels, J.E., and Michaels, T.E. (2010, January 18\u201323). Comparison of the effects of applied loads and temperature variations on guided wave propagation. Proceedings of the AIP Conference, San Diego, CA, USA.","DOI":"10.1063\/1.3591854"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"N73","DOI":"10.1088\/0964-1726\/13\/5\/N01","article-title":"Structural health monitoring of composite structures using Lamb wave tomography","volume":"13","author":"Prasad","year":"2004","journal-title":"Smart Mater. Struct."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1177\/1475921713513975","article-title":"Non-damage-related influences on Lamb wave-based structural health monitoring of carbon fiber-reinforced plastic structures","volume":"13","author":"Schubert","year":"2014","journal-title":"Struct. Health Monit."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1098\/rsta.2006.1935","article-title":"Effects of environmental and operational variability on structural health monitoring","volume":"365","author":"Sohn","year":"2006","journal-title":"Philos. Trans. R. Soc. A Math. Phys. Eng. Sci."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1121\/1.2932071","article-title":"Temperature effects in ultrasonic Lamb wave structural health monitoring systems","volume":"124","author":"Salamone","year":"2008","journal-title":"J. Acoust. Soc. Am."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Eybpoosh, M., Berg\u00e9s, M., and Noh, H.Y. (2014, January 23\u201325). Investigation on the effects of environmental and operational conditions (EOC) on diffuse-field ultrasonic guided-waves in pipes. Proceedings of the Computing in Civil and Building Engineering, Orlando, FL, USA.","DOI":"10.1061\/9780784413616.149"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.ultras.2005.05.001","article-title":"A methodology for structural health monitoring with diffuse ultrasonic waves in the presence of temperature variations","volume":"43","author":"Lu","year":"2005","journal-title":"Ultrasonics"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1088\/0964-1726\/15\/4\/010","article-title":"The temperature stability of guided wave structural health monitoring systems","volume":"15","author":"Konstantinidis","year":"2006","journal-title":"Smart Mater. Struct."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Lu, Z., Lee, S.J., Michaels, J.E., and Michaels, T.E. (2010, January 18\u201323). On the optimization of temperature compensation for guided wave structural health monitoring. Proceedings of the AIP Conference, San Diego, CA, USA.","DOI":"10.1063\/1.3362320"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2226","DOI":"10.1109\/TUFFC.2012.2448","article-title":"Scale transform signal processing for optimal ultrasonic temperature compensation","volume":"59","author":"Harley","year":"2012","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1177\/1045389X13519001","article-title":"An adaptive filter\u2013based temperature compensation technique for structural health monitoring","volume":"25","author":"Wang","year":"2014","journal-title":"J. Intell. Mater. Syst. Struct."},{"key":"ref_22","first-page":"2712","article-title":"Cointegration: A novel approach for the removal of environmental trends in structural health monitoring data","volume":"467","author":"Cross","year":"2011","journal-title":"Proc. R. Soc. A Math. Phys. Eng. Sci."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"095002","DOI":"10.1088\/0964-1726\/22\/9\/095002","article-title":"Cointegration approach for temperature effect compensation in Lamb-wave-based damage detection","volume":"22","author":"Dao","year":"2013","journal-title":"Smart Mater. Struct."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.ymssp.2013.10.012","article-title":"A multiresolution approach to cointegration for enhanced SHM of structures under varying conditions\u2013an exploratory study","volume":"47","author":"Worden","year":"2014","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1016\/j.ymssp.2004.12.002","article-title":"Structural damage diagnosis under varying environmental conditions\u2014Part I: A linear analysis","volume":"19","author":"Yan","year":"2005","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1016\/j.ymssp.2004.12.003","article-title":"Structural damage diagnosis under varying environmental conditions\u2014Part II: Local PCA for non-linear cases","volume":"19","author":"Yan","year":"2005","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Kullaa, J. (2014). Structural health monitoring under nonlinear environmental or operational influences. Shock Vib., 2014.","DOI":"10.1155\/2014\/863494"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1177\/1475921714522846","article-title":"A novel physics-based temperature compensation model for structural health monitoring using ultrasonic guided waves","volume":"13","author":"Roy","year":"2014","journal-title":"Struct. Health Monit."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1109\/TUFFC.2008.626","article-title":"Numerical implementation of matching pursuit for the analysis of complex ultrasonic signals","volume":"55","author":"Lu","year":"2008","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Sun, H., Yi, J., Xu, Y., Wang, Y., and Qing, X. (2019). Identification and Compensation Technique of Non-Uniform Temperature Field for Lamb Wave-and Multiple Sensors-Based Damage Detection. Sensors, 19.","DOI":"10.3390\/s19132930"},{"key":"ref_31","unstructured":"Blaise, E. (2004). Built-in diagnostics for sandwich structures under extreme temperatures. [Ph.D. Thesis, Stanford University]."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.ultras.2015.03.003","article-title":"The influence of temperature variations on ultrasonic guided waves in anisotropic CFRP plates","volume":"60","author":"Putkis","year":"2015","journal-title":"Ultrasonics"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2181","DOI":"10.1177\/1045389X14549873","article-title":"Validation and evaluation of damage identification using probability-based diagnostic imaging on a stiffened composite panel","volume":"26","author":"Wu","year":"2014","journal-title":"J. Intell. Mater. Syst. Struct."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/23\/5174\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:37:35Z","timestamp":1760189855000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/23\/5174"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,26]]},"references-count":33,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["s19235174"],"URL":"https:\/\/doi.org\/10.3390\/s19235174","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,26]]}}}