{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,12]],"date-time":"2026-07-12T02:54:05Z","timestamp":1783824845269,"version":"3.55.0"},"reference-count":30,"publisher":"MDPI AG","issue":"23","license":[{"start":{"date-parts":[[2019,11,29]],"date-time":"2019-11-29T00:00:00Z","timestamp":1574985600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001700","name":"Ministry of Education, Culture, Sports, Science and Technology","doi-asserted-by":"publisher","award":["16H040301, 18H03762"],"award-info":[{"award-number":["16H040301, 18H03762"]}],"id":[{"id":"10.13039\/501100001700","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This work describes a hydrogel fluorescence microsensor for prolonged stable temperature measurements. Temperature measurement using microsensors has the potential to provide information about cells, tissues, and the culture environment, with optical measurement using a fluorescent dye being a promising microsensing approach. However, it is challenging to achieve stable measurements over prolonged periods with conventional measurement methods based on the fluorescence intensity of fluorescent dye because the excited fluorescent dye molecules are bleached by the exposure to light. The decrease in fluorescence intensity induced by photobleaching causes measurement errors. In this work, a photobleaching compensation method based on the diffusion of fluorescent dye inside a hydrogel microsensor is proposed. The factors that influence compensation in the hydrogel microsensor system are the interval time between measurements, material, concentration of photo initiator, and the composition of the fluorescence microsensor. These factors were evaluated by comparing a polystyrene fluorescence microsensor and a hydrogel fluorescence microsensor, both with diameters of 20 \u00b5m. The hydrogel fluorescence microsensor made from 9% poly (ethylene glycol) diacrylate (PEGDA) 575 and 2% photo initiator showed excellent fluorescence intensity stability after exposure (standard deviation of difference from initial fluorescence after 100 measurement repetitions: within 1%). The effect of microsensor size on the stability of the fluorescence intensity was also evaluated. The hydrogel fluorescence microsensors, with sizes greater than the measurement area determined by the axial resolution of the confocal microscope, showed a small decrease in fluorescence intensity, within 3%, after 900 measurement repetitions. The temperature of deionized water in a microchamber was measured for 5400 s using both a thermopile and the hydrogel fluorescence microsensor. The results showed that the maximum error and standard deviation of error between these two sensors were 0.5 \u00b0C and 0.3 \u00b0C, respectively, confirming the effectiveness of the proposed method.<\/jats:p>","DOI":"10.3390\/s19235247","type":"journal-article","created":{"date-parts":[[2019,11,29]],"date-time":"2019-11-29T10:58:21Z","timestamp":1575025101000},"page":"5247","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Hydrogel Fluorescence Microsensor with Fluorescence Recovery for Prolonged Stable Temperature Measurements"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7588-905X","authenticated-orcid":false,"given":"Hairulazwan","family":"Hashim","sequence":"first","affiliation":[{"name":"Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan"},{"name":"Faculty of Engineering Technology, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8902-883X","authenticated-orcid":false,"given":"Hisataka","family":"Maruyama","sequence":"additional","affiliation":[{"name":"Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuke","family":"Akita","sequence":"additional","affiliation":[{"name":"Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2508-1615","authenticated-orcid":false,"given":"Fumihito","family":"Arai","sequence":"additional","affiliation":[{"name":"Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,11,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1177\/0885328217699108","article-title":"Application of an indicator-immobilizedgel-sheet for measuring the pH surrounding a calcium phosphate-based biomaterial","volume":"31","author":"Masuda","year":"2017","journal-title":"J. Biomater. Appl."},{"key":"ref_2","first-page":"1","article-title":"The influence of virus infection on the extracellular pH of the host cell detected on cell membrane","volume":"7","author":"Liu","year":"2016","journal-title":"Front. Microbiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.virusres.2018.09.011","article-title":"Influenza virus replication raises the temperature of cells","volume":"257","author":"Maruyama","year":"2018","journal-title":"Virus Res."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Aoki, H., Mogi, C., Hisada, T., Nakakura, T., Kamide, Y., Ichimonji, I., Tomura, H., Tobo, M., Sato, K., and Tsurumaki, H. (2013). Proton-sensing ovarian cancer G protein-coupled receptor 1 on dendritic cells is required for airway responses in a murine asthma model. PLoS ONE, 8.","DOI":"10.1371\/journal.pone.0079985"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3821","DOI":"10.1039\/c1lc20391f","article-title":"Optically trapped microsensors for microfluidic temperature measurement by fluorescence lifetime imaging microscopy","volume":"11","author":"Bennet","year":"2011","journal-title":"Lab Chip"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1111\/jmi.12033","article-title":"Temperature measurement in the microscopic regime: A comparison between fluorescence lifetime- and intensity-based methods","volume":"250","author":"Paviolo","year":"2013","journal-title":"J. Microsc."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00604-003-0037-x","article-title":"Probes and Polymers for Optical Sensing of Oxygen","volume":"143","author":"Amao","year":"2003","journal-title":"Microchim. Acta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/ncomms1714","article-title":"Intracellular temperature mapping with a fluorescent polymeric thermometer and fluorescence lifetime imaging microscopy","volume":"3","author":"Okabe","year":"2012","journal-title":"Nat. Commun."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"7834","DOI":"10.1039\/c3cs60102a","article-title":"Luminescent probes and sensors for temperature","volume":"42","author":"Wang","year":"2013","journal-title":"Chem. Soc. Rev."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Maruyama, H., Masanobu, K., and Arai, F. (2015, January 21\u201325). Fluorescence sensor array for non-contact measurement of oxygen consumption rate of single oocyte. Proceedings of the Transducers, Anchorage, AK, USA.","DOI":"10.1109\/ICRA.2015.7139682"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3666","DOI":"10.1039\/C4CS00039K","article-title":"Optical methods for sensing and imaging oxygen: Materials, spectroscopies and applications","volume":"43","author":"Wang","year":"2014","journal-title":"Chem. Soc. Rev."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1007\/s12566-012-0032-y","article-title":"Indicators for optical oxygen sensors","volume":"4","author":"Quaranta","year":"2012","journal-title":"Bioanal. Rev."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"6837","DOI":"10.1039\/C4NR00461B","article-title":"Photon upconversion sensitized nanoprobes for sensing and imaging of pH","volume":"6","author":"Arppe","year":"2014","journal-title":"Nanoscale"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1246\/cl.1996.141","article-title":"Three-dimensional pH microprobing with an optically-manipulated fluorescent particle","volume":"25","author":"Sasaki","year":"1996","journal-title":"Chem. Lett."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"3257","DOI":"10.1016\/j.snb.2017.09.152","article-title":"Direct detection of organophosphate compounds in water by a fluorescence-based biosensing device","volume":"255","author":"Carullo","year":"2018","journal-title":"Sens. Actuators B Chem."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2657","DOI":"10.1039\/b501536g","article-title":"Materials for fluorescence-based optical chemical sensors","volume":"15","author":"Wolfbeis","year":"2005","journal-title":"J. Mater. Chem."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.optcom.2018.05.025","article-title":"A microfiber temperature sensor based on fluorescence lifetime","volume":"426","author":"Zhao","year":"2018","journal-title":"Opt. Commun."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2641","DOI":"10.1021\/cr900343z","article-title":"Fluorescence lifetime measurements and biological imaging","volume":"110","author":"Berezin","year":"2010","journal-title":"Chem. Rev."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1083\/jcb.200903097","article-title":"Accuracy and precision in quantitative fluorescence microscopy","volume":"185","author":"Waters","year":"2009","journal-title":"J. Cell Biol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s10404-008-0401-6","article-title":"Functional gel-microbead manipulated by optical tweezers for local environment measurement in microchip","volume":"6","author":"Maruyama","year":"2009","journal-title":"Microfluid. Nanofluidics"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Hashim, H., Maruyama, H., Masuda, T., and Arai, F. (2016). Manipulation and immobilization of a single fluorescence nanosensor for selective injection into cells. Sensors, 16.","DOI":"10.3390\/s16122041"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2588","DOI":"10.1016\/S0006-3495(95)80442-X","article-title":"Photobleaching kinetics of fluorescein in quantitative fluorescence microscopy","volume":"68","author":"Song","year":"1995","journal-title":"Biophys. J."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Tsai, H.M., Souris, J.S., Kim, H.J., Cheng, S.H., Chen, C.T., Lo, L.W., Chen, L., and Kao, C.M. (November, January 29). Rapid measurement of fluorescence lifetimes using SiPM detection and waveform sampling. Proceedings of the 2016 IEEE Nuclear Science Symposium and Medical Imaging Conference, Room Temperature Semiconductor Detectors (NSS\/MIC\/RTSD 2016), Strasburg, France.","DOI":"10.1109\/NSSMIC.2016.8069566"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"5385","DOI":"10.1073\/pnas.86.14.5385","article-title":"Direct measurement of interstitial convection and diffusion of albumin in normal and neoplastic tissues by fluorescence photobleaching","volume":"86","author":"Chary","year":"1989","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_25","unstructured":"Kino, G.S., and Corle, T.R. (1996). Confocal Scanning Optical Microscopy and Related Imaging Systems, Academic Press."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"596","DOI":"10.20965\/jrm.2013.p0596","article-title":"Fluorescent-based temperature measurement with simple compensation of photo-degradation using hydrogel-tool and color space conversion","volume":"25","author":"Maruyama","year":"2013","journal-title":"J. Robot. Mechatron."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"10630","DOI":"10.1073\/pnas.94.20.10630","article-title":"Fluorescence and photobleaching dynamics of single light-harvesting\u2009complexes","volume":"94","author":"Bopp","year":"1997","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.snb.2014.06.079","article-title":"Multi-fluorescent micro-sensor for accurate measurement of pH and temperature variations in micro-environments","volume":"203","author":"Liu","year":"2014","journal-title":"Sens. Actuators B Chem."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"O\u2019Donnell, K., Boyd, A., and Meenan, B. (2019). Controlling Fluid Diffusion and Release through Mixed-Molecular-Weight Poly(ethylene) Glycol Diacrylate (PEGDA) Hydrogels. Materials, 12.","DOI":"10.3390\/ma12203381"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1109\/TMECH.2011.2161878","article-title":"Photoprocessible hydrogel microsensor for local environment measurement on a microfluidic chip","volume":"16","author":"Maruyama","year":"2011","journal-title":"IEEE\/ASME Trans. Mechatron."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/23\/5247\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:38:31Z","timestamp":1760189911000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/23\/5247"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,29]]},"references-count":30,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["s19235247"],"URL":"https:\/\/doi.org\/10.3390\/s19235247","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,29]]}}}