{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T11:24:36Z","timestamp":1787225076062,"version":"build-2736575974"},"reference-count":44,"publisher":"MDPI AG","issue":"23","license":[{"start":{"date-parts":[[2019,12,3]],"date-time":"2019-12-03T00:00:00Z","timestamp":1575331200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003407","name":"Ministero dell\u2019Istruzione, dell\u2019Universit\u00e0 e della Ricerca","doi-asserted-by":"publisher","award":["Law 232\/2016"],"award-info":[{"award-number":["Law 232\/2016"]}],"id":[{"id":"10.13039\/501100003407","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Factory-calibrated continuous glucose monitoring (FC-CGM) sensors are new devices used in type 1 diabetes (T1D) therapy to measure the glucose concentration almost continuously for 10\u201314 days without requiring any in vivo calibration. Understanding and modelling CGM errors is important when designing new tools for T1D therapy. Available literature CGM error models are not suitable to describe the FC-CGM sensor error, since their domain of validity is limited to 12-h time windows, i.e., the time between two consecutive in vivo calibrations. The aim of this paper is to develop a model of the error of FC-CGM sensors. The dataset used contains 79 FC-CGM traces collected by the Dexcom G6 sensor. The model is designed to dissect the error into its three main components: effect of plasma-interstitium kinetics, calibration error, and random measurement noise. The main novelties are the model extension to cover the entire sensor lifetime and the use of a new single-step identification procedure. The final error model, which combines a first-order linear dynamic model to describe plasma-interstitium kinetics, a second-order polynomial model to describe calibration error, and an autoregressive model to describe measurement noise, proved to be suitable to describe FC-CGM sensor errors, in particular improving the estimation of the physiological time-delay.<\/jats:p>","DOI":"10.3390\/s19235320","type":"journal-article","created":{"date-parts":[[2019,12,4]],"date-time":"2019-12-04T04:30:35Z","timestamp":1575433835000},"page":"5320","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Development of an Error Model for a Factory-Calibrated Continuous Glucose Monitoring Sensor with 10-Day Lifetime"],"prefix":"10.3390","volume":"19","author":[{"given":"Martina","family":"Vettoretti","sequence":"first","affiliation":[{"name":"Department of Information Engineering, University of Padova, 35131 Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristina","family":"Battocchio","sequence":"additional","affiliation":[{"name":"Department of Information Engineering, University of Padova, 35131 Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3248-1393","authenticated-orcid":false,"given":"Giovanni","family":"Sparacino","sequence":"additional","affiliation":[{"name":"Department of Information Engineering, University of Padova, 35131 Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8041-2280","authenticated-orcid":false,"given":"Andrea","family":"Facchinetti","sequence":"additional","affiliation":[{"name":"Department of Information Engineering, University of Padova, 35131 Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,12,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1177\/193229681000400225","article-title":"Self-monitoring of blood glucose: Practical aspects","volume":"4","author":"Kirk","year":"2010","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Cappon, G., Acciaroli, G., Vettoretti, M., Facchinetti, A., and Sparacino, G. (2017). Wearable continuous glucose monitoring sensors: A revolution in diabetes treatment. Electronics, 6.","DOI":"10.3390\/electronics6030065"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.diabres.2017.08.005","article-title":"Continuous glucose monitoring: A review of the technology and clinical use","volume":"133","author":"Klonoff","year":"2017","journal-title":"Diabetes Res. Clin. Pract."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"383","DOI":"10.4093\/dmj.2019.0121","article-title":"Continuous glucose monitoring sensors for diabetes management: A review of technologies and applications","volume":"43","author":"Cappon","year":"2019","journal-title":"Diabetes Metab. J."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1177\/1932296818774078","article-title":"Continuous glucose monitoring: Current use in diabetes management and possible future applications","volume":"12","author":"Vettoretti","year":"2018","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Acciaroli, G., Vettoretti, M., Facchinetti, A., and Sparacino, G. (2018). Calibration of minimally invasive continuous glucose monitoring sensors: State-of-the-art and current perspectives. Biosensors (Basel), 8.","DOI":"10.3390\/bios8010024"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1109\/TBME.2017.2706974","article-title":"Reduction of blood glucose measurements to calibrate subcutaneous glucose sensors: A Bayesian multiday framework","volume":"65","author":"Acciaroli","year":"2018","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1177\/1932296813511747","article-title":"Feasibility of factory calibration for subcutaneous glucose sensors in subjects with diabetes","volume":"8","author":"Hoss","year":"2014","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"S44","DOI":"10.1089\/dia.2017.0025","article-title":"Factory-calibrated continuous glucose sensors: The science behind the technology","volume":"19","author":"Hoss","year":"2017","journal-title":"Diabetes Technol. Ther."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1089\/dia.2018.0401","article-title":"Factory-calibrated continuous glucose monitoring: How and why it works, and the dangers of reuse beyond approved duration of wear","volume":"21","author":"Forlenza","year":"2019","journal-title":"Diabetes Technol. Ther."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Staal, O.M., Hansen, H.M.U., Christiansen, S.C., Fougner, A.L., Carlsen, S.M., and Stavdahl, \u00d8. (2018). Differences between flash continuous glucose monitor and fingerprick measurements. Biosensors (Basel), 17.","DOI":"10.3390\/bios8040093"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1089\/dia.2014.0378","article-title":"The performance and usability of a factory-calibrated flash glucose monitoring system","volume":"17","author":"Bailey","year":"2015","journal-title":"Diabetes Technol. Ther."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1089\/dia.2018.0150","article-title":"Accuracy of a factory-calibrated, real-time continuous glucose monitoring system during 10 days of use in youth and adults with diabetes","volume":"20","author":"Wadwa","year":"2018","journal-title":"Diabetes Technol. Ther."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1177\/1932296818798816","article-title":"Performance of a factory-calibrated, real-time continuous glucose monitoring system in pediatric participants with type 1 diabetes","volume":"13","author":"Welsh","year":"2019","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1177\/193229680800200504","article-title":"A review of the foreign-body response to subcutaneously-implanted devices: The role of macrophages and cytokines in biofouling and fibrosis","volume":"2","author":"Ward","year":"2008","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_16","first-page":"637","article-title":"Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and foreign body response-part II: Examples and application","volume":"5","author":"Helton","year":"2011","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"e158","DOI":"10.2337\/dc15-1096","article-title":"Effect of acetaminophen on CGM glucose in an outpatient setting","volume":"38","author":"Maahs","year":"2015","journal-title":"Diabetes Care"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Schiavon, M., Acciaroli, G., Vettoretti, M., Giaretta, A., and Visentin, R. (2018, January 18\u201321). A model of acetaminophen pharmacokinetics and its effect on continuous glucose monitoring sensor measurements. Proceedings of the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA.","DOI":"10.1109\/EMBC.2018.8512257"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1177\/1932296818755797","article-title":"Resistance to acetaminophen interference in a novel continuous glucose monitoring system","volume":"12","author":"Calhoun","year":"2018","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1089\/dia.2016.0112","article-title":"Interstitial fluid glucose is not just a shifted-in-time but a distorted mirror of blood glucose: Insight from an in silico study","volume":"18","author":"Cobelli","year":"2016","journal-title":"Diabetes Technol. Ther."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1177\/0954411917702931","article-title":"In silico assessment of biomedical products: The conundrum of rare but not so rare events in two case studies","volume":"231","author":"Viceconti","year":"2017","journal-title":"Proc. Inst. Mech. Eng. Part H"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1109\/TBME.2017.2746340","article-title":"Type-1 diabetes patient decision simulator for in silico testing safety and effectiveness of insulin treatments","volume":"65","author":"Vettoretti","year":"2018","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1089\/dia.2018.0079","article-title":"Continuous glucose monitoring and insulin informed advisory system with automated titration and dosing of insulin reduces glucose variability in type 1 diabetes mellitus","volume":"20","author":"Breton","year":"2018","journal-title":"Diabetes Technol. Ther."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1089\/dia.2019.0139","article-title":"A real-time continuous glucose monitoring based algorithm to trigger hypotreatments to prevent\/mitigate hypoglycemic events","volume":"21","author":"Camerlingo","year":"2019","journal-title":"Diabetes Technol. Ther."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1109\/JBHI.2015.2464088","article-title":"An advanced bolus calculator for type 1 diabetes: System architecture and usability results","volume":"20","author":"Pesl","year":"2016","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1177\/1932296818759558","article-title":"A Neural-network-based approach to personalize insulin bolus calculation using continuous glucose monitoring","volume":"12","author":"Cappon","year":"2018","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1177\/1932296818777524","article-title":"In silico assessment of literature insulin bolus calculation methods accounting for glucose rate of change","volume":"13","author":"Cappon","year":"2019","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1186\/s12938-019-0658-x","article-title":"Combining continuous glucose monitoring and insulin pumps to automatically tune the basal insulin infusion in diabetes therapy: A review","volume":"18","author":"Vettoretti","year":"2019","journal-title":"Biomed. Eng. Online"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1111\/dom.12542","article-title":"Automated insulin pump suspension for hypoglycaemia mitigation: Development, implementation and implications","volume":"17","author":"Davis","year":"2015","journal-title":"Diabetes Obes. Metab."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1177\/1932296816672689","article-title":"Sensor-augmented insulin pumps and hypoglycemia prevention in type 1 diabetes","volume":"11","author":"Steineck","year":"2017","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1007\/s00125-016-4022-4","article-title":"Coming of age: The artificial pancreas for type 1 diabetes","volume":"59","author":"Thabit","year":"2016","journal-title":"Diabetologia"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1007\/s11892-018-1051-z","article-title":"Advances in closed-loop insulin delivery systems in patients with type 1 diabetes","volume":"18","author":"Dadlani","year":"2018","journal-title":"Curr. Diabetes Rep."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/j.endinu.2017.10.011","article-title":"Automated blood glucose control in type 1 diabetes: A review of progress and challenges","volume":"65","author":"Bertachi","year":"2018","journal-title":"Endocrinol. Diabetes Nutr."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1177\/193229680800200517","article-title":"Analysis, modelling and simulation of the accuracy of continuous glucose sensors","volume":"2","author":"Breton","year":"2008","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2234","DOI":"10.1002\/sim.4254","article-title":"Fitting dynamic models with forcing functions: Application to continuous glucose monitoring in insulin therapy","volume":"30","author":"Lunn","year":"2011","journal-title":"Stat. Med."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1109\/TBME.2013.2284023","article-title":"Modeling the glucose sensor error","volume":"61","author":"Facchinetti","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1007\/s11517-014-1226-y","article-title":"Model of glucose sensor error components: Identification and assessment for new Dexcom G4 generation devices","volume":"53","author":"Facchinetti","year":"2015","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Biagi, L., Ramkissoon, C.M., Facchinetti, A., Leal, Y., and Vehi, J. (2017). Modeling the error of the Medtronic Paradigm Veo Enlite glucose sensor. Sensors (Basel), 12.","DOI":"10.3390\/s17061361"},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Vettoretti, M., Del Favero, S., Sparacino, G., and Facchinetti, A. (2019, January 23\u201327). Modeling the error of factory calibrated continuous glucose monitoring sensors: Application to Dexcom G6 sensor data. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany.","DOI":"10.1109\/EMBC.2019.8856790"},{"key":"ref_40","first-page":"1035","article-title":"Solution of incorrectly formulated problems and the regularization method","volume":"4","author":"Tikhonov","year":"1963","journal-title":"Sov. Math. Dokl."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1016\/S0005-1098(96)00254-3","article-title":"Nonparametric input estimation in physiological systems: Problems, methods, and case studies","volume":"33","author":"Sparacino","year":"1997","journal-title":"Automatica"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"E561","DOI":"10.1152\/ajpendo.1999.277.3.E561","article-title":"Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring","volume":"277","author":"Rebin","year":"1999","journal-title":"Am. J. Physiol. Endocrinol. Metab."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1089\/dia.2015.0119","article-title":"Modeling plasma-to-interstitium glucose kinetics from multitracer plasma and microdialysis data","volume":"11","author":"Schiavon","year":"2015","journal-title":"Diabetes Technol. Ther."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1089\/dia.2015.0250","article-title":"Modeling transient disconnections and compression artifacts of continuous glucose sensors","volume":"18","author":"Facchinetti","year":"2016","journal-title":"Diabetes Technol. Ther."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/23\/5320\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:39:41Z","timestamp":1760189981000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/23\/5320"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,3]]},"references-count":44,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["s19235320"],"URL":"https:\/\/doi.org\/10.3390\/s19235320","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,3]]}}}