{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,3]],"date-time":"2025-12-03T03:34:16Z","timestamp":1764732856665,"version":"build-2065373602"},"reference-count":28,"publisher":"MDPI AG","issue":"24","license":[{"start":{"date-parts":[[2019,12,10]],"date-time":"2019-12-10T00:00:00Z","timestamp":1575936000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Spanish Ministry of Science, Innovation and Universities, the Spanish State Agency of Research, and the European Union through the European Regional Development Fund","award":["RTI2018-096677-B-I00"],"award-info":[{"award-number":["RTI2018-096677-B-I00"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The aim of this paper is to describe new methods for detecting the appearance of unexpected obstacles during normal gait from EEG signals, improving the accuracy and reducing the false positive rate obtained in previous studies. This way, an exoskeleton for rehabilitation or assistance of people with motor limitations commanded by a Brain-Machine Interface (BMI) could be stopped in case that an obstacle suddenly appears during walking. The EEG data of nine healthy subjects were collected during their normal gait while an obstacle appearance was simulated by the projection of a laser line in a random pattern. Different approaches were considered for selecting the parameters of the BMI: subsets of electrodes, time windows and classifier probabilities, which were based on a linear discriminant analysis (LDA). The pseudo-online results of the BMI for detecting the appearance of obstacles, with an average percentage of 63.9% of accuracy and 2.6 false positives per minute, showed a significant improvement over previous studies.<\/jats:p>","DOI":"10.3390\/s19245444","type":"journal-article","created":{"date-parts":[[2019,12,10]],"date-time":"2019-12-10T10:52:41Z","timestamp":1575975161000},"page":"5444","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Pseudo-Online BMI Based on EEG to Detect the Appearance of Sudden Obstacles during Walking"],"prefix":"10.3390","volume":"19","author":[{"given":"Mar\u00eda","family":"Elvira","sequence":"first","affiliation":[{"name":"Brain-Machine Interface Systems Lab, Miguel Hern\u00e1ndez University of Elche, Avda. de la Universidad S\/N, Ed. Innova, Elche, 03202 Alicante, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8057-5952","authenticated-orcid":false,"given":"Eduardo","family":"I\u00e1\u00f1ez","sequence":"additional","affiliation":[{"name":"Brain-Machine Interface Systems Lab, Miguel Hern\u00e1ndez University of Elche, Avda. de la Universidad S\/N, Ed. Innova, Elche, 03202 Alicante, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7000-5390","authenticated-orcid":false,"given":"Vicente","family":"Quiles","sequence":"additional","affiliation":[{"name":"Brain-Machine Interface Systems Lab, Miguel Hern\u00e1ndez University of Elche, Avda. de la Universidad S\/N, Ed. Innova, Elche, 03202 Alicante, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4269-1554","authenticated-orcid":false,"given":"Mario","family":"Ortiz","sequence":"additional","affiliation":[{"name":"Brain-Machine Interface Systems Lab, Miguel Hern\u00e1ndez University of Elche, Avda. de la Universidad S\/N, Ed. Innova, Elche, 03202 Alicante, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5548-9657","authenticated-orcid":false,"given":"Jos\u00e9 M.","family":"Azor\u00edn","sequence":"additional","affiliation":[{"name":"Brain-Machine Interface Systems Lab, Miguel Hern\u00e1ndez University of Elche, Avda. de la Universidad S\/N, Ed. Innova, Elche, 03202 Alicante, Spain"}]}],"member":"1968","published-online":{"date-parts":[[2019,12,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/S2173-5808(10)70036-5","article-title":"Neuro-rehabilitation after stroke","volume":"25","author":"Irimia","year":"2010","journal-title":"Neurolog\u00eda (Engl. Ed.)"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"53","DOI":"10.14326\/abe.8.53","article-title":"Development of a Brain-machine Interface for Stroke Rehabilitation Using Event-related Desynchronization and Proprioceptive Feedback","volume":"8","author":"Wada","year":"2019","journal-title":"Adv. Biomed. Eng."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1016\/S1388-2457(02)00057-3","article-title":"Brain\u2013computer interfaces for communication and control","volume":"113","author":"Wolpaw","year":"2002","journal-title":"Clin. Neurophysiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3389\/neuro.07.003.2009","article-title":"Extracting kinematic parameters for monkey bipedal walking from cortical neuronal ensemble activity","volume":"3","author":"Fitzsimmons","year":"2009","journal-title":"Front. Integr. Neurosci."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1109\/TRO.2008.915453","article-title":"Lower extremity exoskeletons and active orthoses: Challenges and state-of-the-art","volume":"24","author":"Dollar","year":"2008","journal-title":"IEEE Trans. Robot."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1875","DOI":"10.1152\/jn.00104.2011","article-title":"Neural decoding of treadmill walking from noninvasive electroencephalographic signals","volume":"106","author":"Presacco","year":"2011","journal-title":"J. Neurophysiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1186\/s12984-018-0394-7","article-title":"Randomized controlled trial of robot-assisted gait training with dorsiflexion assistance on chronic stroke patients wearing ankle-foot-orthosis","volume":"15","author":"Yeung","year":"2018","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/s12984-017-0345-8","article-title":"Volition-adaptive control for gait training using wearable exoskeleton: Preliminary tests with incomplete spinal cord injury individuals","volume":"15","author":"Rajasekaran","year":"2018","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"036007","DOI":"10.1088\/1741-2560\/12\/3\/036007","article-title":"Continuous detection of the self-initiated walking pre-movement state from EEG correlates without session-to-session recalibration","volume":"12","author":"Sburlea","year":"2015","journal-title":"J. Neural Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.clinph.2014.05.003","article-title":"A brain\u2013computer interface for single-trial detection of gait initiation from movement related cortical potentials","volume":"126","author":"Jiang","year":"2015","journal-title":"Clin. Neurophysiol."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Lisi, G., and Morimoto, J. (2015). EEG single-trial detection of gait speed changes during treadmill walk. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0125479"},{"key":"ref_12","first-page":"174","article-title":"Neurophysiologic Assessment of Motor Imagery Training by Using Virtual Reality for Pediatric Population with Cerebral Palsy","volume":"15","author":"Serrano","year":"2018","journal-title":"Revista Iberoamericana de Autom\u00e1tica e Inform\u00e1tica Industrial"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1650029","DOI":"10.1142\/S0129065716500295","article-title":"EEG-based Detection of Starting and Stopping During Gait Cycle","volume":"26","author":"Hortal","year":"2016","journal-title":"Int. J. Neural Syst."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"021004","DOI":"10.1088\/1741-2552\/aaa8c0","article-title":"Brain\u2013machine interfaces for controlling lower-limb powered robotic systems","volume":"15","author":"He","year":"2018","journal-title":"J. Neural Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1926","DOI":"10.1109\/TNSRE.2018.2868486","article-title":"A Novel Method of Emergency Situation Detection for a Brain-Controlled Vehicle by Combining EEG Signals with Surrounding Information","volume":"26","author":"Bi","year":"2018","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Lin, C.T., Liang, S.F., Chao, W.H., Ko, L.W., Chao, C.F., Chen, Y.C., and Huang, T.Y. (2006, January 8\u201311). Driving style classification by analyzing EEG responses to unexpected obstacle dodging tasks. Proceedings of the 2006 IEEE International Conference on Systems, Man and Cybernetics, Taipei, Taiwan.","DOI":"10.1109\/ICSMC.2006.385084"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1186\/s12984-015-0095-4","article-title":"Analyzing EEG signals to detect unexpected obstacles during walking","volume":"12","author":"Costa","year":"2015","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Salazar-Varas, R., Costa, A., \u00dabeda, A., I\u00e1\u00f1ez, E., and Azor\u00edn, J.M. (2015, January 22\u201324). Changes in brain activity due to the sudden apparition of an obstacle during gait. Proceedings of the 2015 7th International IEEE\/EMBS Conference on Neural Engineering (NER), Montpellier, France.","DOI":"10.1109\/NER.2015.7146572"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1016\/j.tins.2006.07.004","article-title":"Brain\u2013machine interfaces: Past, present and future","volume":"29","author":"Lebedev","year":"2006","journal-title":"TRENDS Neurosci."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1080\/00029238.1985.11080163","article-title":"Ten Percent Electrode System for Topographic Studies of Spontaneous and Evoked EEG Activities","volume":"25","author":"Chatrian","year":"1985","journal-title":"Am. J. EEG Technol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1109\/18.119727","article-title":"Singularity detection and processing with wavelets","volume":"38","author":"Mallat","year":"1992","journal-title":"IEEE Trans. Inf. Theory"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"60","DOI":"10.3389\/fnins.2016.00060","article-title":"Characterization of Artifacts Produced by Gel Displacement on Non-invasive Brain-Machine Interfaces during Ambulation","volume":"10","author":"Costa","year":"2016","journal-title":"Front. Neurosci."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2941","DOI":"10.1093\/brain\/awh648","article-title":"Brain motor system function after chronic, complete spinal cord injury","volume":"128","author":"Cramer","year":"2005","journal-title":"Brain"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Webb, A.R. (2003). Statistical Pattern Recognition, John Wiley & Sons.","DOI":"10.1002\/0470854774"},{"key":"ref_25","unstructured":"Fukunaga, K. (2013). Introduction to Statistical Pattern Recognition, Academic Press."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1186\/s12984-017-0290-6","article-title":"NLR, MLP, SVM, and LDA: A comparative analysis on EMG data from people with trans-radial amputation","volume":"14","author":"Bellingegni","year":"2017","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_27","unstructured":"I\u00e1\u00f1ez, E., Costa, A., \u00dabeda, A., Rodr\u00edguez-Ugarte, M., and Azor\u00edn, J.M. (2016, January 7\u20139). A new upgrading model for detecting the reaction to obstacle appearance during walking using EEG. Proceedings of the XXXVII Jornadas de Autom\u00e1tica, Madrid, Spain."},{"key":"ref_28","first-page":"321","article-title":"Reducing the False Positives Rate in a BCI System to Detect Error-Related EEG Potentials","volume":"Volume 7","author":"Costa","year":"2004","journal-title":"Replace, Repair, Restore, Relieve\u2014Bridging Clinical and Engineering Solutions in Neurorehabilitation, Proceedings of the 2nd International Conference on NeuroRehabilitation (ICNR 2014), Aalborg, Denmark, 24\u201326 June 2014"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/24\/5444\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:41:01Z","timestamp":1760190061000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/19\/24\/5444"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,10]]},"references-count":28,"journal-issue":{"issue":"24","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["s19245444"],"URL":"https:\/\/doi.org\/10.3390\/s19245444","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2019,12,10]]}}}