{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T02:23:23Z","timestamp":1777429403315,"version":"3.51.4"},"reference-count":20,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2019,12,24]],"date-time":"2019-12-24T00:00:00Z","timestamp":1577145600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Various gait parameters can be used to assess the risk of falling in older adults. However, the state-of-the-art systems used to quantify gait parameters often come with high costs as well as training and space requirements. Gait analysis systems, which use mobile and commercially available cameras, can be an easily available, marker-free alternative. In a study with 44 participants (age \u2265 65 years), gait patterns were analyzed with three different systems: a pressure sensitive walkway system (GAITRite-System, GS) as gold standard, Motognosis Labs Software using a Microsoft Kinect Sensor (MKS), and a smartphone camera-based application (SCA). Intertrial repeatability showed moderate to excellent results for MKS (ICC(1,1) 0.574 to 0.962) for almost all measured gait parameters and moderate reliability in SCA measures for gait speed (ICC(1,1) 0.526 to 0.535). All gait parameters of MKS showed a high level of agreement with GS (ICC(2,k) 0.811 to 0.981). Gait parameters extracted with SCA showed poor reliability. The tested gait analysis systems based on different camera systems are currently only partially able to capture valid gait parameters. If the underlying algorithms are adapted and camera technology is advancing, it is conceivable that these comparatively simple methods could be used for gait analysis.<\/jats:p>","DOI":"10.3390\/s20010125","type":"journal-article","created":{"date-parts":[[2019,12,24]],"date-time":"2019-12-24T10:28:43Z","timestamp":1577183323000},"page":"125","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":61,"title":["Using New Camera-Based Technologies for Gait Analysis in Older Adults in Comparison to the Established GAITRite System"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8025-266X","authenticated-orcid":false,"given":"Anika","family":"Steinert","sequence":"first","affiliation":[{"name":"Geriatrics Research Group, Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, corporate member of Freie Universit\u00e4t Berlin, Humboldt-Universit\u00e4t zu Berlin, and Berlin Institute of Health, Charit\u00e9platz 1, 10117 Berlin, Germany"}]},{"given":"Igor","family":"Sattler","sequence":"additional","affiliation":[{"name":"Geriatrics Research Group, Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, corporate member of Freie Universit\u00e4t Berlin, Humboldt-Universit\u00e4t zu Berlin, and Berlin Institute of Health, Charit\u00e9platz 1, 10117 Berlin, Germany"}]},{"given":"Karen","family":"Otte","sequence":"additional","affiliation":[{"name":"NeuroCure Clinical Research Center, Charit\u00e9-Universitaetsmedizin Berlin, corporate member of Freie Universit\u00e4t Berlin, Humboldt-Universit\u00e4t zu Berlin, and Berlin Institute of Health, Charit\u00e9platz 1, 10117 Berlin, Germany"},{"name":"Motognosis GmbH, Sch\u00f6nhauser Allee 177, 10119 Berlin, Germany"}]},{"given":"Hanna","family":"R\u00f6hling","sequence":"additional","affiliation":[{"name":"Motognosis GmbH, Sch\u00f6nhauser Allee 177, 10119 Berlin, Germany"}]},{"given":"Sebastian","family":"Mansow-Model","sequence":"additional","affiliation":[{"name":"Motognosis GmbH, Sch\u00f6nhauser Allee 177, 10119 Berlin, Germany"}]},{"given":"Ursula","family":"M\u00fcller-Werdan","sequence":"additional","affiliation":[{"name":"Geriatrics Research Group, Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, corporate member of Freie Universit\u00e4t Berlin, Humboldt-Universit\u00e4t zu Berlin, and Berlin Institute of Health, Charit\u00e9platz 1, 10117 Berlin, Germany"}]}],"member":"1968","published-online":{"date-parts":[[2019,12,24]]},"reference":[{"key":"ref_1","unstructured":"World Health Organization (2008). WHO Global Report on Falls Prevention in Older Age, World Health Organization."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Rapp, K., Freiberger, E., Todd, C., Klenk, J., Becker, C., Denkinger, M., Scheidt-Nave, C., and Fuchs, J. (2014). Fall incidence in Germany: Results of two population-based studies, and comparison of retrospective and prospective falls data collection methods. BMC Geriatr., 14.","DOI":"10.1186\/1471-2318-14-105"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1007\/s10039-011-1766-4","article-title":"Sturzpr\u00e4vention im Krankenhaus und Pflegeheim","volume":"14","author":"Pericie","year":"2012","journal-title":"Trauma Berufskrankh."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Springer, S., and Seligmann, G.Y. (2016). Validity of the Kinect for Gait Assessment: A Focused Review. Sensors, 16.","DOI":"10.3390\/s16020194"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s40520-015-0420-6","article-title":"The effect of aging on gait parameters in able-bodied older subjects: A literature review","volume":"28","author":"Aboutorabi","year":"2016","journal-title":"Aging Clin. Exp. Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"896","DOI":"10.1093\/gerona\/glp033","article-title":"Quantitative Gait Markers and Incident Fall Risk in Older Adults","volume":"64","author":"Verghese","year":"2009","journal-title":"J. Gerontol. A Biol. Sci. Med. Sci."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/S0966-6362(02)00053-X","article-title":"Concurrent related validity of the GAITRite walkway system for quantification of the spatial and temporal parameters of gait","volume":"17","author":"Bilney","year":"2003","journal-title":"Gait Posture"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1016\/j.gaitpost.2014.08.006","article-title":"Detection of gait cycles in treadmill walking using a Kinect","volume":"41","author":"Auvinet","year":"2015","journal-title":"Gait Posture"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.gaitpost.2015.05.002","article-title":"Accuracy of the Microsoft Kinect for measuring gait parameters during treadmill walking","volume":"42","author":"Xu","year":"2015","journal-title":"Gait Posture"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Baldewijns, G., Verheyden, G., Vanrumste, B., and Croonenborghs, T. (2014, January 26\u201330). Validation of the kinect for gait analysis using the GAITRite walkway. Proceedings of the 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, USA.","DOI":"10.1109\/EMBC.2014.6944976"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2722","DOI":"10.1016\/j.jbiomech.2013.08.011","article-title":"Concurrent validity of the Microsoft Kinect for assessment of spatiotemporal gait variables","volume":"46","author":"Clark","year":"2013","journal-title":"J. Biomech."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.gaitpost.2004.10.005","article-title":"Validity of the GAITRite\u00ae walkway system for the measurement of averaged and individual step parameters of gait","volume":"22","author":"Webster","year":"2005","journal-title":"Gait Posture"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1053\/apmr.2001.19778","article-title":"The validity and reliability of the GAITRite system\u2019s measurements: A preliminary evaluation","volume":"82","author":"McDonough","year":"2001","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1596","DOI":"10.1177\/1352458515625807","article-title":"Validity of visual perceptive computing for static posturography in patients with multiple sclerosis","volume":"22","author":"Behrens","year":"2016","journal-title":"Mult. Scler. J."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Otte, K., Kayser, B., Mansow-Model, S., Verrel, J., Paul, F., Brandt, A.U., and Schmitz-H\u00fcbsch, T. (2016). Accuracy and Reliability of the Kinect Version 2 for Clinical Measurement of Motor Function. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0166532"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/3072959.3073596","article-title":"VNect","volume":"36","author":"Mehta","year":"2017","journal-title":"ACM Trans. Graph."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Finkbiner, M.J., Gaina, K.M., McRandall, M.C., Wolf, M.M., Pardo, V.M., Reid, K., Adams, B., and Galen, S.S. (2017). Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study. J. Vis. Exp., 14.","DOI":"10.3791\/54659"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"e36","DOI":"10.2196\/mhealth.8815","article-title":"Smartphone App\u2013Based Assessment of Gait During Normal and Dual-Task Walking: Demonstration of Validity and Reliability","volume":"6","author":"Manor","year":"2018","journal-title":"JMIR Mhealth Uhealth"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Niijima, A., Mizuno, O., and Tanaka, T. (2014, January 9\u201312). A study of gait analysis with a smartphone for measurement of hip joint angle. Proceedings of the Signal and Information Processing Association Annual Summit and Conference (APSIPA), 2014 Asia-Pacific, Siem Reap, Cambodia.","DOI":"10.1109\/APSIPA.2014.7041573"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/1\/125\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:45:11Z","timestamp":1760190311000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/1\/125"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,24]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,1]]}},"alternative-id":["s20010125"],"URL":"https:\/\/doi.org\/10.3390\/s20010125","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,24]]}}}