{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T21:08:02Z","timestamp":1783026482336,"version":"3.54.6"},"reference-count":18,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2020,2,11]],"date-time":"2020-02-11T00:00:00Z","timestamp":1581379200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Key Research &amp; Development Plan of China","award":["No.2016YFB1001401"],"award-info":[{"award-number":["No.2016YFB1001401"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["No.61572110"],"award-info":[{"award-number":["No.61572110"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Wearable electrocardiogram (ECG) devices are universally used around the world for patients who have cardiovascular disease (CVD). At present, how to suppress motion artifacts is one of the most challenging issues in the field of physiological signal processing. In this paper, we propose an adaptive cancellation algorithm based on multi-inertial sensors to suppress motion artifacts in ambulatory ECGs. Firstly, this method collects information related to the electrode motion through multi-inertial sensors. Then, the part that is not related to the electrode motion is removed through wavelet transform, which improves the correlation of the reference input signal. In this way, the ability of the adaptive cancellation algorithm to remove motion artifacts is improved in the ambulatory ECG. Subsequent experimentation demonstrated that the wavelet adaptive cancellation algorithm based on multi-inertial sensors can effectively remove motion artifacts in ambulatory ECGs.<\/jats:p>","DOI":"10.3390\/s20040970","type":"journal-article","created":{"date-parts":[[2020,2,11]],"date-time":"2020-02-11T11:45:30Z","timestamp":1581421530000},"page":"970","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["A Wavelet Adaptive Cancellation Algorithm Based on Multi-Inertial Sensors for the Reduction of Motion Artifacts in Ambulatory ECGs"],"prefix":"10.3390","volume":"20","author":[{"given":"Fan","family":"Xiong","sequence":"first","affiliation":[{"name":"School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongyi","family":"Chen","sequence":"additional","affiliation":[{"name":"School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miao","family":"Huang","sequence":"additional","affiliation":[{"name":"School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,2,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"e0207176","DOI":"10.1371\/journal.pone.0207176","article-title":"Two-stage motion artefact reduction algorithm for electrocardiogram using weighted adaptive noise cancelling and recursive Hampel filter","volume":"13","author":"Ghaleb","year":"2018","journal-title":"PLoS ONE"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1750","DOI":"10.3390\/s150101750","article-title":"Embroidered electrode with silver\/titanium coating for long-term ECG monitoring","volume":"15","author":"Weder","year":"2015","journal-title":"Sensors"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1109\/TBCAS.2013.2260159","article-title":"A Configurable and Low-Power Mixed Signal SoC for Portable ECG Monitoring Applications","volume":"8","author":"Kim","year":"2014","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_4","unstructured":"Liu, Y., and Pecht, M.G. (September, January 30). Reduction of skin stretch induced motion artifacts in electrocardiogram monitoring using adaptive filtering. Proceedings of the 28th IEEE EMBS Annual International Conference, New York, NY, USA."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"439","DOI":"10.3390\/polym9090439","article-title":"ECG Monitoring Garment Using Conductive Carbon Paste for Reduced Motion Artifacts","volume":"9","author":"Lee","year":"2017","journal-title":"Polymers"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/0967-3334\/36\/1\/1","article-title":"A motion artifact generation and assessment system for the rapid testing of surface biopotential electrodes","volume":"36","author":"CMert","year":"2015","journal-title":"Physiol. Meas."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/1742-6596\/76\/1\/012038","article-title":"A portable system for acquiring and removing motion artefact from ECG signals","volume":"76","author":"Griffiths","year":"2007","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s10916-007-9112-x","article-title":"Adaptive motion artifacts reduction using 3-axis accelerometer in e-textile ECG measurement system","volume":"32","author":"Yoon","year":"2008","journal-title":"J. Med. Syst."},{"key":"ref_9","unstructured":"Xu1, P.J., Wang, F.M., Liu, H., and Tao, X.M. (2016). Characterization of Motion Artifacts from the Interfacial Instability of Textile Electrodes and Skin using a Simulated Method. Text. Bioeng. Inf. Symp. Proc., 1, 887\u2013894."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"155","DOI":"10.2345\/0899-8205-45.2.155","article-title":"Reduction of motion artifacts in electrocardiogram monitoring using an optical sensor","volume":"45","author":"Liu","year":"2011","journal-title":"Biomed. Instrum. Technolo."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Seo, M., Choi, M., Lee, J.S., and Kim, S.W. (2018). Adaptive noise reduction algorithm to improve R peak detection in ECG measured by capacitive ECG sensors. Sensors, 18.","DOI":"10.3390\/s18072086"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Tong, D.A., Bartels, K.A., and Honeyager, K.S. (2002, January 23\u201326). Adaptive Reduction of Motion Artifact In The Electrocardiogram. Proceedings of the Second Joint EMBS\/BMES Conference, Huston, TX, USA.","DOI":"10.1109\/IEMBS.2002.1106451"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Pandey, V.K. (2010, January 3\u20135). Adaptive Filtering for Baseline Wander Removal in ECG. Proceedings of the 10th IEEE International Conference on Information Technology and Applications in Biomedicine, Corfu, Greece.","DOI":"10.1109\/ITAB.2010.5687642"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1109\/10.83591","article-title":"Applications of Adaptive Filtering to ECG Analysis: Noise Cancellation and Arrhythmia Detection","volume":"38","author":"Thakor","year":"1991","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_15","unstructured":"Yang, Y.F. (2013). Application of Empirical Mode Decomposition in Vibration Analysis, National Defense Industry Press."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1109\/PROC.1975.10036","article-title":"Adaptive Noise Cancelling: Principles and Applications","volume":"63","author":"Widrow","year":"1976","journal-title":"Proc. IEEE"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1622","DOI":"10.1016\/j.compbiomed.2013.07.028","article-title":"Research of fetal ECG extraction using wavelet analysis and adaptive filtering","volume":"43","author":"Wu","year":"2013","journal-title":"Comput. Biol. Med."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/j.measurement.2011.10.025","article-title":"Delineation of ECG characteristic features using multiresolution wavelet analysis method","volume":"45","author":"Banerjee","year":"2012","journal-title":"Measurement"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/4\/970\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T08:56:54Z","timestamp":1760173014000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/4\/970"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,11]]},"references-count":18,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020,2]]}},"alternative-id":["s20040970"],"URL":"https:\/\/doi.org\/10.3390\/s20040970","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,11]]}}}