{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T02:43:59Z","timestamp":1760237039721,"version":"build-2065373602"},"reference-count":21,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2020,2,12]],"date-time":"2020-02-12T00:00:00Z","timestamp":1581465600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["11927812"],"award-info":[{"award-number":["11927812"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Capacitive transducers are widely used in fundamental physics experiments, seismology, Earth or planetary observations, and space scientific and technical applications because of their high precision, simple structure, and compatibility with various measurements. However, in real applications, there is a trade-off between their resolution and dynamic range. Therefore, this paper is aimed at enlarging the dynamic range while ensuring high resolution. In this paper, a noise analysis of a capacitive transducer is presented, which shows that the amplitude noise of the carrier wave is the main limiting factor. Hence, a new method of generating a carrier wave with lower-amplitude noise is proposed in the paper. Based on the experimental verification, it is found that the carrier wave produced through the new method performed significantly better than the typical digital carrier wave when they were compared in the same sensing circuit. With the carrier wave produced through the new method, the dynamic range of the capacitive transducer can reach 120.7 dB, which is 18.3 dB greater than for the typical direct digital synthesis (DDS) method. In addition, the resolution of the carrier wave is mainly limited by the voltage reference components.<\/jats:p>","DOI":"10.3390\/s20040992","type":"journal-article","created":{"date-parts":[[2020,2,20]],"date-time":"2020-02-20T03:20:03Z","timestamp":1582168803000},"page":"992","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Design of a Carrier Wave for Capacitive Transducer with Large Dynamic Range"],"prefix":"10.3390","volume":"20","author":[{"given":"Zhu","family":"Li","sequence":"first","affiliation":[{"name":"TianQin Research Center for Gravitational Physics and School of Physics and Astronomy, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xian","family":"Zhang","sequence":"additional","affiliation":[{"name":"TianQin Research Center for Gravitational Physics and School of Physics and Astronomy, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shu","family":"Zou","sequence":"additional","affiliation":[{"name":"TianQin Research Center for Gravitational Physics and School of Physics and Astronomy, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiangqing","family":"Huang","sequence":"additional","affiliation":[{"name":"TianQin Research Center for Gravitational Physics and School of Physics and Astronomy, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chao","family":"Xue","sequence":"additional","affiliation":[{"name":"TianQin Research Center for Gravitational Physics and School of Physics and Astronomy, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianping","family":"Liu","sequence":"additional","affiliation":[{"name":"TianQin Research Center for Gravitational Physics and School of Physics and Astronomy, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi","family":"Liu","sequence":"additional","affiliation":[{"name":"TianQin Research Center for Gravitational Physics and School of Physics and Astronomy, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shanqing","family":"Yang","sequence":"additional","affiliation":[{"name":"TianQin Research Center for Gravitational Physics and School of Physics and Astronomy, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1014-9784","authenticated-orcid":false,"given":"Liangcheng","family":"Tu","sequence":"additional","affiliation":[{"name":"TianQin Research Center for Gravitational Physics and School of Physics and Astronomy, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,2,12]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1088\/0022-3735\/6\/7\/001","article-title":"The design and some applications of sensitive capacitance micrometers","volume":"6","author":"Jones","year":"1973","journal-title":"J. Phys. E Sci. Instrum."},{"key":"ref_2","unstructured":"Herrick, R.J. (1997). Capacitive Sensors: Design and Applications, IEEE."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1016\/S0094-5765(99)00132-0","article-title":"Electrostatic space accelerometers for present and future missions","volume":"45","author":"Touboul","year":"1999","journal-title":"Acta Astronaut."},{"key":"ref_4","first-page":"321","article-title":"Accelerometers for CHAMP, GRACE and GOCE space missions: Synergy and evolution","volume":"40","author":"Touboul","year":"1999","journal-title":"Bollett. Geofis. Teor. Appl."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/S0924-4247(99)00227-7","article-title":"Capacitive detection scheme for space accelerometers applications","volume":"78","author":"Josselin","year":"1999","journal-title":"Sens. Actuators A"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.asr.2006.09.019","article-title":"STEP (satellite test of the equivalence principle)","volume":"39","author":"Sumner","year":"2007","journal-title":"Adv. Space Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1088\/0256-307X\/21\/7\/007","article-title":"Excitation frequency effect of differential capacitance transducer for equivalence principle test","volume":"21","author":"Zhou","year":"2004","journal-title":"Chin. Phys. Lett."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"4133","DOI":"10.1088\/0264-9381\/18\/19\/323","article-title":"Progress in the development of a position sensor for LISA drag-free control","volume":"18","author":"Cavalleri","year":"2001","journal-title":"Class. Quantum Grav."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1751","DOI":"10.1088\/0264-9381\/19\/7\/371","article-title":"Position sensors for LISA drag-free control","volume":"19","author":"Weber","year":"2002","journal-title":"Class. Quantum Grav."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1109\/JSEN.2011.2163389","article-title":"LTP is FEE sensing channel: Front-end modeling and symmetry adjustment method","volume":"12","author":"Gan","year":"2012","journal-title":"IEEE Sens. J."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1117\/12.458564","article-title":"Position sensors for flight testing of LISA drag-free control","volume":"4856","author":"Weber","year":"2003","journal-title":"Proc. SPIE-ISOP"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Yan, S.T., Xie, Y.F., and Deng, Z.G. (2017). A subnano-g electrostatic force-rebalanced flexure accelerometer for gravity gradient instruments. Sensors, 17.","DOI":"10.3390\/s17112669"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/j.sna.2018.07.050","article-title":"A nano-g micromachined seismic sensor for levelling-free measurements","volume":"280","author":"Wu","year":"2018","journal-title":"Sens. Actuators A Phys."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1071\/EG01247","article-title":"FALCON gravity gradiometer technology","volume":"32","author":"Lee","year":"2001","journal-title":"Explor. Geophys."},{"key":"ref_15","first-page":"306","article-title":"Recent gravity gradiometer developments","volume":"1081","author":"Metzger","year":"1977","journal-title":"Am. Inst. Astronaut. Aeronaut."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Huang, X.Q., Deng, Z.G., and Xie, Y.F. (2017). A new scale factor adjustment method for magnetic force feedback accelerometer. Sensors, 17.","DOI":"10.3390\/s17112471"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"062004","DOI":"10.1103\/PhysRevD.96.062004","article-title":"Capacitive sensing of test mass motion with nanometer precision over millimeter-wide sensing gaps for space-borne gravitational reference sensors","volume":"96","author":"Armano","year":"2017","journal-title":"Phys. Rev. D"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"055001","DOI":"10.1063\/1.4873334","article-title":"Resonant frequency detection and adjustment method for a capacitive transducer with differential transformer bridge","volume":"85","author":"Hu","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"125016","DOI":"10.1088\/1361-6439\/aae9cd","article-title":"A precise spacing-control method in MEMS packaging for capacitive accelerometer applications","volume":"28","author":"Wu","year":"2018","journal-title":"J. Micromech. Microeng."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/j.nima.2006.04.041","article-title":"Readout system and predicted performance of a low-noise low-frequency horizontal accelerometer","volume":"564","author":"Bertolini","year":"2006","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/s11467-009-0019-5","article-title":"Capacitive position measurement for high-precision space inertial sensor","volume":"4","author":"Bai","year":"2009","journal-title":"Front. Phys. China"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/4\/992\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T08:57:15Z","timestamp":1760173035000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/4\/992"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,12]]},"references-count":21,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020,2]]}},"alternative-id":["s20040992"],"URL":"https:\/\/doi.org\/10.3390\/s20040992","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2020,2,12]]}}}