{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T07:04:41Z","timestamp":1768287881532,"version":"3.49.0"},"reference-count":20,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2020,2,19]],"date-time":"2020-02-19T00:00:00Z","timestamp":1582070400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000377","name":"Dunhill Medical Trust","doi-asserted-by":"publisher","award":["R595\/0717"],"award-info":[{"award-number":["R595\/0717"]}],"id":[{"id":"10.13039\/501100000377","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Splinting techniques are widely used in medicine to inhibit the movement of arthritic joints. Studies into the effectiveness of splinting as a method of pain reduction have generally yielded positive results, however, no significant difference has been found in clinical outcomes between splinting types. Tactile sensing has shown great promise for the integration into splinting devices and may offer further information into applied forces to find the most effective methods of splinting. Hall effect-based tactile sensors are of particular interest in this application owing to their low-cost, small size, and high robustness. One complexity of the sensors is the relationship between the elastomer geometry and the measurement range. This paper investigates the design parameters of Hall effect tactile sensors for use in hand splinting. Finite element simulations are used to locate the areas in which sensitivity is high in order to optimise the deflection range of the sensor. Further simulations then investigate the mechanical response and force ranges of the elastomer layer under loading which are validated with experimental data. A 4 mm radius, 3 mm-thick sensor is identified as meeting defined sensing requirements for range and sensitivity. A prototype sensor is produced which exhibits a pressure range of 45 kPa normal and 6 kPa shear. A proof of principle prototype demonstrates how this can be integrated to form an instrumented splint with multi-axis sensing capability and has the potential to inform clinical practice for improved splinting.<\/jats:p>","DOI":"10.3390\/s20041123","type":"journal-article","created":{"date-parts":[[2020,2,20]],"date-time":"2020-02-20T03:20:03Z","timestamp":1582168803000},"page":"1123","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["Design and Evaluation of Magnetic Hall Effect Tactile Sensors for Use in Sensorized Splints"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2961-8483","authenticated-orcid":false,"given":"Dominic","family":"Jones","sequence":"first","affiliation":[{"name":"School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4123-4159","authenticated-orcid":false,"given":"Lefan","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1087-8426","authenticated-orcid":false,"given":"Ali","family":"Ghanbari","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0781-8759","authenticated-orcid":false,"given":"Vasiliki","family":"Vardakastani","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Imperial College London, London SW7 2AZ, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7282-6651","authenticated-orcid":false,"given":"Angela E.","family":"Kedgley","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Imperial College London, London SW7 2AZ, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8058-4186","authenticated-orcid":false,"given":"Matthew D.","family":"Gardiner","sequence":"additional","affiliation":[{"name":"Kennedy Institute of Rheumatology, University of Oxford, Oxford OX3 7FY, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tonia L.","family":"Vincent","sequence":"additional","affiliation":[{"name":"Kennedy Institute of Rheumatology, University of Oxford, Oxford OX3 7FY, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2867-0420","authenticated-orcid":false,"given":"Peter R.","family":"Culmer","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8983-173X","authenticated-orcid":false,"given":"Ali","family":"Alazmani","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,2,19]]},"reference":[{"key":"ref_1","first-page":"342","article-title":"Braces and splints for musculoskeletal conditions","volume":"75","author":"Gravlee","year":"2007","journal-title":"Am. Fam. Physician"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1001\/jama.288.10.1245","article-title":"Splinting vs surgery in the treatment of carpal tunnel syndrome: A randomized controlled trial","volume":"288","author":"Gerritsen","year":"2002","journal-title":"JAMA"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"4","DOI":"10.2106\/JBJS.RVW.17.00156","article-title":"Treatment of basilar thumb arthritis: A critical analysis review","volume":"6","author":"Gottschalk","year":"2018","journal-title":"JBJS Rev."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2750","DOI":"10.1109\/TBME.2015.2422751","article-title":"From wearable sensors to smart implants\u2014Toward pervasive and personalized healthcare","volume":"62","author":"Leff","year":"2015","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_5","first-page":"259","article-title":"Sensor-based assessment of cast placement and removal","volume":"196","author":"Laufer","year":"2014","journal-title":"Stud. Health Technol. Inform."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Tuan, C.C., Lu, C.H., Wu, Y.C., Yeh, W.L., Chen, M.C., Lee, T.F., Chen, Y.J., and Kao, H.K. (2019). Development of a System for Real-Time Monitoring of Pressure, Temperature, and Humidity in Casts. Sensors, 19.","DOI":"10.3390\/s19102417"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1302\/0301-620X.100B12.BJJ-2018-0721.R1","article-title":"Rapid decrease of cast-induced forces during the treatment of clubfoot using the Ponseti method","volume":"100","author":"Giesberts","year":"2018","journal-title":"Bone Jt. J."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Giesberts, R.B., ter Haar, A.M., Sanderman, G.M., Hekman, E.E.G., and Verkerke, G.J. (2019). Tissue adaptation rate in the treatment of Dupuytren contracture. J. Hand Therapy, in press.","DOI":"10.1016\/j.jht.2018.09.014"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.sna.2012.02.051","article-title":"A review of tactile sensing technologies with applications in biomedical engineering","volume":"179","author":"Tiwana","year":"2012","journal-title":"Sens. Actuators A"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Casey, V., Grace, P., and Clarke-Moloney, M. (2010). Pressure measurement at biomedical interfaces. Applied Biomedical Engineering, IntechOpen.","DOI":"10.5772\/21855"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1243\/PIME_PROC_1994_208_291_02","article-title":"The reaction of skin and soft tissue to shear forces applied externally to the skin surface","volume":"208","author":"Zhang","year":"1994","journal-title":"Proc. Inst. Mech. Eng. H J. Eng. Med."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1097\/01.ASW.0000363489.38996.13","article-title":"Friction and shear considerations in pressure ulcer development","volume":"23","author":"Hanson","year":"2010","journal-title":"Adv. Skin Wound Care"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Wang, H., De Boer, G., Kow, J., Alazmani, A., Ghajari, M., Hewson, R., and Culmer, P. (2016). Design methodology for magnetic field-based soft tri-axis tactile sensors. Sensors, 16.","DOI":"10.3390\/s16091356"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Boer, G.D., Raske, N., Wang, H., Kow, J., Alazmani, A., Ghajari, M., Culmer, P., and Hewson, R. (2017). Design optimisation of a magnetic field based soft tactile sensor. Sensors, 17.","DOI":"10.3390\/s17112539"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/S0894-1130(00)80006-X","article-title":"The biomechanics of a thumb carpometacarpal immobilization splint: Design and fitting","volume":"13","author":"Colditz","year":"2000","journal-title":"J. Hand Therapy"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1900315","DOI":"10.1002\/admt.201900315","article-title":"Flexible and stretchable electronic skin with high durability and shock resistance via embedded 3D printing technology for human activity monitoring and personal healthcare","volume":"4","author":"Wei","year":"2019","journal-title":"Adv. Mater. Technol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1115\/1.2787241","article-title":"A pressure projection method for nearly incompressible rubber hyperelasticity, part II: Applications","volume":"63","author":"Chen","year":"1996","journal-title":"J. Appl. Mech."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1089\/soro.2017.0140","article-title":"Hybrid soft\u2013rigid actuators for minimally invasive surgery","volume":"5","author":"Paterno","year":"2018","journal-title":"Soft Robot."},{"key":"ref_19","unstructured":"First4Magnets (2019, September 30). Neodymium Magnet Grades. Available online: https:\/\/www.first4magnets.com\/tech-centre-i61\/information-and-articles-i70\/neodymium-magnet-information-i82\/grades-of-neodymium-magnets-i92."},{"key":"ref_20","unstructured":"Yu, H., and Wilamowski, B.M. (2011). Levenberg-marquardt training. The Industrial Electronics Handbook, CRC Press. [2nd ed.]. Available online: http:\/\/www.eng.auburn.edu\/~wilambm\/pap\/2011\/K10149_C012.pdf."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/4\/1123\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T08:58:56Z","timestamp":1760173136000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/4\/1123"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,19]]},"references-count":20,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020,2]]}},"alternative-id":["s20041123"],"URL":"https:\/\/doi.org\/10.3390\/s20041123","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,19]]}}}