{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T16:27:43Z","timestamp":1781195263540,"version":"3.54.1"},"reference-count":30,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2020,4,20]],"date-time":"2020-04-20T00:00:00Z","timestamp":1587340800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["51505406"],"award-info":[{"award-number":["51505406"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004543","name":"China Scholarship Council","doi-asserted-by":"publisher","award":["201807230005"],"award-info":[{"award-number":["201807230005"]}],"id":[{"id":"10.13039\/501100004543","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This paper presents a rotating focused field eddy-current (EC) sensing technique, which leverages the advantages of magnetic field focusing and rotating magnetic field, for arbitrary orientation defects detection. The sensor consists of four identical excitation coils orthogonally arranged in an upside-down pyramid configuration and a giant magneto-resistive (GMR) detection element. The four coils are connected to form two figure-8-shaped focusing sub-probes, which are fed by two identical harmonic currents with 90 degrees phase difference. A finite element model-based study of arbitrary orientation defects detection was performed to understand the probe operational characteristics and optimize its design parameters. Probe prototyping and experimental validation were also carried out on a carbon steel plate specimen with four prefabricated surface-breaking defects. In-situ spot inspection with the probe rotating above the defect and a manual line-scan inspection were both conducted. Results showed that the probe has the capability of detecting defects with any orientations while maintaining the same sensitivity and the defect depth can be quantitatively evaluated by using the signal amplitude. Compared with the existing rotating field probes, the presented probe does not require additional excitation adjustment or data fusion. Meanwhile, due to its focusing effect, it can generate a strong rotating magnetic field at the defect location with a weak background noise, thus yielding superior signal-to-noise ratio.<\/jats:p>","DOI":"10.3390\/s20082345","type":"journal-article","created":{"date-parts":[[2020,4,21]],"date-time":"2020-04-21T04:49:38Z","timestamp":1587444578000},"page":"2345","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":41,"title":["Rotating Focused Field Eddy-Current Sensing for Arbitrary Orientation Defects Detection in Carbon Steel"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8955-8358","authenticated-orcid":false,"given":"Zhiyuan","family":"Xu","sequence":"first","affiliation":[{"name":"School of Mechanical Engineering, Xiangtan University, Xiangtan 411105, China"},{"name":"Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiang","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Xiangtan University, Xiangtan 411105, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5958-3683","authenticated-orcid":false,"given":"Yiming","family":"Deng","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,4,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2525","DOI":"10.3390\/s110302525","article-title":"Non-destructive techniques based on eddy current testing","volume":"11","year":"2011","journal-title":"Sensors"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1177\/0020294018801382","article-title":"Challenges in improving the performance of eddy current testing","volume":"52","author":"AbdAlla","year":"2019","journal-title":"Meas. Control"},{"key":"ref_3","unstructured":"NSF-NDT Resource Center (2020, January 13). Probes\u2014Mode of Operation. Available online: https:\/\/www.nde-ed.org\/EducationResources\/CommunityCollege\/EddyCurrents\/ProbesCoilDesign\/ProbesModeOp.htm."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1109\/JSEN.2014.2362072","article-title":"Modeling and design optimization of an eddy current sensor for superficial and subsuperficial crack detection in inconel claddings","volume":"15","author":"Pereira","year":"2014","journal-title":"IEEE Sens. J."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/LMAG.2019.2936392","article-title":"Integrated magnetic sensor probe and excitation wire for nondestructive detection of submillimeter defects","volume":"10","author":"Tsukada","year":"2019","journal-title":"IEEE Magn. Lett."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1784\/insi.47.5.277.65048","article-title":"Study of magnetic sensors for pulsed eddy current techniques","volume":"47","author":"Tian","year":"2005","journal-title":"Insight"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"R31","DOI":"10.1088\/0957-0233\/18\/3\/R01","article-title":"Induction coil sensors\u2014A review","volume":"18","author":"Tumanski","year":"2007","journal-title":"Meas. Sci. Technol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"883","DOI":"10.5516\/NET.09.2014.055","article-title":"Influence of signal-to-noise ratio on eddy current signals of cracks in steam generator tubes","volume":"46","author":"Hur","year":"2014","journal-title":"Nucl. Eng. Technol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1016\/j.sna.2006.10.013","article-title":"Development of differential probes in pulsed eddy current testing for noise suppression","volume":"135","author":"Shu","year":"2007","journal-title":"Sens. Actuators A"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Bernieri, A., Betta, G., Ferrigno, L., Laracca, M., and Rasile, A. (2018, January 14\u201317). ECT probe improvement for in-service non-destructive testing on conductive materials. Proceedings of the 2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Houston, TX, USA.","DOI":"10.1109\/I2MTC.2018.8409837"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Repelianto, A.S., and Kasai, N. (2019). The improvement of flaw detection by the configuration of uniform eddy current probes. Sensors, 19.","DOI":"10.3390\/s19020397"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1533","DOI":"10.1109\/TIM.2018.2890757","article-title":"Eddy current testing probe based on double-coil excitation and GMR sensor","volume":"68","author":"Bernieri","year":"2019","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.ndteint.2014.09.009","article-title":"A new dual driver planar eddy current probe with dynamically controlled induction pattern","volume":"70","author":"Rosado","year":"2015","journal-title":"NDT E Int."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"5862","DOI":"10.1063\/1.342181","article-title":"Localized stimulation of neural tissues in the brain by means of a paired configuration of time-varying magnetic fields","volume":"64","author":"Ueno","year":"1988","journal-title":"J. Appl. Phys."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Lu, M., and Ueno, S. (2017). Comparison of the induced fields using different coil configurations during deep transcranial magnetic stimulation. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0178422"},{"key":"ref_16","first-page":"57","article-title":"Analytical solution of eddy current problem due to a Figure 8 shaped coil above a conducting plate","volume":"29","author":"Zhang","year":"2007","journal-title":"Nondestr. Test."},{"key":"ref_17","first-page":"119","article-title":"Transient electromagnetic field due to a focusing coil above a conducting plate","volume":"30","author":"Zhang","year":"2010","journal-title":"Proc. CSEE"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1016\/j.ndteint.2013.09.005","article-title":"Eddy-current non-destructive testing system for the determination of crack orientation","volume":"61","author":"Hamia","year":"2014","journal-title":"NDT E Int."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Wincheski, B., Simpson, J., Namkung, M., Perey, D., Scales, E., and Louie, R. (2002). Development of giant magnetoresistive inspection system for detection of deep fatigue cracks under airframe fasteners. AIP Conference Proceedings, American Institute of Physics.","DOI":"10.1063\/1.1472906"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Dogaru, T., Smith, C.H., Schneider, R.W., and Smith, S.T. (2004). Deep crack detection around fastener holes in airplane multi-layered structures using GMR-based eddy current probes. AIP Conference Proceedings, American Institute of Physics.","DOI":"10.1063\/1.1711650"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1784\/insi.2007.49.3.133","article-title":"Improvement in subsurface fatigue cracks under airframes fasteners detection using improved rotating giant magneto resistance magnetometer head","volume":"49","author":"Dolabdjian","year":"2006","journal-title":"Insight"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1109\/JSEN.2014.2341653","article-title":"Rotating field EC-GMR sensor for crack detection at fastener site in layered structures","volume":"15","author":"Yang","year":"2014","journal-title":"IEEE Sens. J."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1109\/JSEN.2015.2488289","article-title":"Differential sensor measurement with rotating current excitation for evaluating multilayer structures","volume":"16","author":"Ye","year":"2015","journal-title":"IEEE Sens. J."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.3233\/JAE-171193","article-title":"EC probe with orthogonal excitation coils and TMR sensor for CFRP inspection","volume":"59","author":"Ye","year":"2019","journal-title":"Int. J. Appl. Electromagnet Mech."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Repelianto, A.S., Kasai, N., Sekino, K., Matsunaga, M., and Trung, L.Q. (2019). Flaw detection in aluminum plates using a rotating uniform eddy current probe with two pairs of excitation coils. Metals, 9.","DOI":"10.3390\/met9101069"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1109\/TIM.2019.2903610","article-title":"Synthetic magnetic field imaging with triangle excitation coil for inspection of any orientation defect","volume":"69","author":"Wang","year":"2020","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Fan, M., Wang, Q., Cao, B., Ye, B., Sunny, A.I., and Tian, G. (2016). Frequency optimization for enhancement of surface defect classification using the eddy current technique. Sensors, 16.","DOI":"10.3390\/s16050649"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"2447","DOI":"10.1109\/TMAG.2005.854331","article-title":"Analytical model for tilted coils in eddy-current nondestructive inspection","volume":"41","author":"Theodoulidis","year":"2005","journal-title":"IEEE Trans. Magn."},{"key":"ref_29","unstructured":"NVE Corporation (2020, March 19). NVE AA\/AB-Series Analog Magnetic Sensors Catalogue. Available online: http:\/\/www.nve.com\/Downloads\/analog_catalog.pdf."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.csi.2010.06.011","article-title":"Detection and characterization of defects using GMR probes and artificial neural networks","volume":"33","author":"Postolache","year":"2011","journal-title":"Comput. Stand. Inter."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/8\/2345\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T14:09:06Z","timestamp":1760364546000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/8\/2345"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,20]]},"references-count":30,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2020,4]]}},"alternative-id":["s20082345"],"URL":"https:\/\/doi.org\/10.3390\/s20082345","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,20]]}}}