{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,24]],"date-time":"2026-11-24T07:17:00Z","timestamp":1795504620136,"version":"4.11.0"},"reference-count":41,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2020,6,3]],"date-time":"2020-06-03T00:00:00Z","timestamp":1591142400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The interest in dry electroencephalography (EEG) electrodes has increased in recent years, especially as everyday suitability earplugs for measuring drowsiness or focus of auditory attention. However, the challenge is still the need for a good electrode material, which is reliable and can be easily processed for highly personalized applications. Laser processing, as used here, is a fast and very precise method to produce personalized electrode configurations that meet the high requirements of in-ear EEG electrodes. The arrangement of the electrodes on the flexible and compressible mats allows an exact alignment to the ear mold and contributes to high wearing comfort, as no edges or metal protrusions are present. For better transmission properties, an adapted coating process for surface enlargement of platinum electrodes is used, which can be controlled precisely. The resulting porous platinum-copper alloy is chemically very stable, shows no exposed copper residues, and enlarges the effective surface area by 40. In a proof-of-principle experiment, these porous platinum electrodes could be used to measure the Berger effect in a dry state using just one ear of a test person. Their signal-to-noise ratio and the frequency transfer function is comparable to gel-based silver\/silver chloride electrodes.<\/jats:p>","DOI":"10.3390\/s20113176","type":"journal-article","created":{"date-parts":[[2020,6,4]],"date-time":"2020-06-04T04:36:09Z","timestamp":1591245369000},"page":"3176","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Highly Porous Platinum Electrodes for Dry Ear-EEG Measurements"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8348-7269","authenticated-orcid":false,"given":"Max","family":"Eickenscheidt","sequence":"first","affiliation":[{"name":"Laboratory for Biomedical Microtechnology, IMTEK, University of Freiburg, 79110 Freiburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Sch\u00e4fer","sequence":"additional","affiliation":[{"name":"Systems Neuroscience &amp; Neurotechnology Unit, Mindscan Lab, Saarland University of Applied Sciences, 66117 Saarbr\u00fccken, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yara","family":"Baslan","sequence":"additional","affiliation":[{"name":"Laboratory for Biomedical Microtechnology, IMTEK, University of Freiburg, 79110 Freiburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudia","family":"Schwarz","sequence":"additional","affiliation":[{"name":"Hahn-Schickard,  79110 Freiburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7349-4254","authenticated-orcid":false,"given":"Thomas","family":"Stieglitz","sequence":"additional","affiliation":[{"name":"Laboratory for Biomedical Microtechnology, IMTEK, University of Freiburg, 79110 Freiburg, Germany"},{"name":"BrainLinks-BrainTools, University of Freiburg,  79110 Freiburg, Germany"},{"name":"Bernstein Center Freiburg, University of Freiburg, 79104 Freiburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,6,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1109\/JBHI.2014.2328317","article-title":"Wearable, wireless EEG solutions in daily life applications: What are we missing?","volume":"19","author":"Mihajlovic","year":"2015","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"16824","DOI":"10.1038\/s41598-019-53115-3","article-title":"Accurate whole-night sleep monitoring with dry-contact ear-EEG","volume":"9","author":"Mikkelsen","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Bernarding, C., Herbig, M.-C., Pratapa, N.A., Choquet, V., Angermayer, J., and Strauss, D.J. (2019, January 20\u201323). Time-Resolved in-vehicle drowsiness monitoring using multimodal electrophysiological data. Proceedings of the 9th International IEEE\/EMBS Conference on Neural Engineering (NER), San Francisco, CA, USA.","DOI":"10.1109\/NER.2019.8717182"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"36020","DOI":"10.1088\/1741-2552\/aa66dd","article-title":"Single-channel in-ear-EEG detects the focus of auditory attention to concurrent tone streams and mixed speech","volume":"14","author":"Fiedler","year":"2017","journal-title":"J. Neural Eng."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"16743","DOI":"10.1038\/srep16743","article-title":"Unobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear","volume":"5","author":"Debener","year":"2015","journal-title":"Sci. Rep."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"438","DOI":"10.3389\/fnins.2015.00438","article-title":"EEG recorded from the ear: Characterizing the ear-EEG method","volume":"9","author":"Mikkelsen","year":"2015","journal-title":"Front. Neurosci."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"46014","DOI":"10.1088\/1741-2560\/11\/4\/046014","article-title":"CNT\/PDMS-based canal-typed ear electrodes for inconspicuous EEG recording","volume":"11","author":"Lee","year":"2014","journal-title":"J. Neural Eng."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Bleichner, M.G., Lundbeck, M., Selisky, M., Minow, F., J\u00e4ger, M., Emkes, R., Debener, S., and de Vos, M. (2015). Exploring miniaturized EEG electrodes for brain-computer interfaces. An EEG you do not see?. Physiol. Rep., 3.","DOI":"10.14814\/phy2.12362"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"21184","DOI":"10.1021\/acsami.8b06484","article-title":"Flexible conductive composite integrated with personal earphone for wireless, real-time monitoring of electrophysiological signs","volume":"10","author":"Lee","year":"2018","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.sbsr.2018.05.001","article-title":"Development of printed and flexible dry ECG electrodes","volume":"20","author":"Chlaihawi","year":"2018","journal-title":"Sens. Bio-Sens. Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1109\/TBME.2018.2835778","article-title":"Dry-Contact electrode ear-EEG","volume":"66","author":"Kappel","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","first-page":"543","article-title":"Ear-EEG from generic earpieces: A feasibility study","volume":"2013","author":"Kidmose","year":"2013","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"ref_13","first-page":"3161","article-title":"Study of impedance spectra for dry and wet EarEEG electrodes","volume":"2015","author":"Kappel","year":"2015","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1016\/j.snb.2016.10.005","article-title":"Towards gel-free electrodes: A systematic study of electrode-skin impedance","volume":"241","author":"Li","year":"2017","journal-title":"Sens. Actuator B Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"12847","DOI":"10.3390\/s140712847","article-title":"Dry EEG electrodes","volume":"14","year":"2014","journal-title":"Sensors"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1109\/TBME.2006.884649","article-title":"A novel dry active electrode for EEG recording","volume":"54","author":"Fonseca","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"23758","DOI":"10.3390\/s141223758","article-title":"Soft, comfortable polymer dry electrodes for high quality ECG and EEG recording","volume":"14","author":"Chen","year":"2014","journal-title":"Sensors"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"41","DOI":"10.29328\/journal.ijpra.1001014","article-title":"Biodegradation of gold and platinum implants in rats studied by electron microscopy","volume":"2","author":"Hendrik","year":"2019","journal-title":"Int. J. Phys. Res. Appl."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1595\/147106711X566816","article-title":"A healthy future: Platinum in medical applications","volume":"55","author":"Cowley","year":"2011","journal-title":"Platinum Metals Rev."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1016\/j.clinph.2004.10.001","article-title":"Evaluation of commercially available electrodes and gels for recording of slow EEG potentials","volume":"116","author":"Tallgren","year":"2005","journal-title":"Clin. Neurophysiol."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Lan, W.-C., Huang, T.-S., Cho, Y.-C., Huang, Y.-T., Walinski, C.J., Chiang, P.-C., Rusilin, M., Pai, F.-T., Huang, C.-C., and Huang, M.-S. (2020). The potential of a nanostructured titanium oxide layer with self-assembled monolayers for biomedical applications: Surface properties and biomechanical behaviors. Appl. Sci., 10.","DOI":"10.3390\/app10020590"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"e154","DOI":"10.3346\/jkms.2018.33.e154","article-title":"Electro-Deposited nanoporous platinum electrode for EEG monitoring","volume":"33","author":"Kim","year":"2018","journal-title":"J. Korean Med. Sci."},{"key":"ref_23","first-page":"5","article-title":"Improving impedance of implantable microwire multi-electrode arrays by ultrasonic electroplating of durable platinum black","volume":"3","author":"Desai","year":"2010","journal-title":"Front. Neuroeng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1002\/celc.201800035","article-title":"Pulsed electrodeposition of highly porous Pt alloys for use in methanol, formic acid, and glucose fuel cells","volume":"5","author":"Frei","year":"2018","journal-title":"ChemElectroChem"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"14749","DOI":"10.1038\/s41598-018-33083-w","article-title":"Graphitic carbon electrodes on flexible substrate for neural applications entirely fabricated using infrared nanosecond laser technology","volume":"8","author":"Vomero","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"943","DOI":"10.3389\/fnins.2019.00943","article-title":"Ear-EEG forward models: Improved head-models for ear-EEG","volume":"13","author":"Kappel","year":"2019","journal-title":"Front. Neurosci."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"415","DOI":"10.3389\/fnhum.2017.00163","article-title":"Concealed, unobtrusive ear-Centered EEG acquisition: CEEGrids for transparent EEG","volume":"11","author":"Bleichner","year":"2017","journal-title":"Front. Hum. Neurosci."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1877","DOI":"10.1016\/j.clinph.2007.04.027","article-title":"Scalp electrical recording during paralysis: Quantitative evidence that EEG frequencies above 20 Hz are contaminated by EMG","volume":"118","author":"Whitham","year":"2007","journal-title":"Clin. Neurophysiol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"66016","DOI":"10.1088\/1741-2552\/aa7eea","article-title":"Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring","volume":"14","author":"Mueller","year":"2017","journal-title":"J. Neural Eng."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"267","DOI":"10.3389\/fnins.2013.00267","article-title":"MEG and EEG data analysis with MNE-Python","volume":"7","author":"Gramfort","year":"2013","journal-title":"Front. Neurosci."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"233121651881660","DOI":"10.1177\/2331216518816600","article-title":"Testing the limits of the stimulus reconstruction approach: Auditory attention decoding in a four-speaker free field environment","volume":"22","author":"Hannemann","year":"2018","journal-title":"Trends Hear."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/j.biomaterials.2015.07.036","article-title":"Nanostructured platinum grass enables superior impedance reduction for neural microelectrodes","volume":"67","author":"Boehler","year":"2015","journal-title":"Biomaterials"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1088\/0967-3334\/21\/2\/307","article-title":"A direct comparison of wet, dry and insulating bioelectric recording electrodes","volume":"21","author":"Searle","year":"2000","journal-title":"Physiol. Meas."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1109\/RBME.2010.2084078","article-title":"Dry-Contact and noncontact biopotential electrodes: Methodological review","volume":"3","author":"Chi","year":"2010","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"G\u00f3recka, J., and Makiewicz, P. (2019). The dependence of electrode impedance on the number of performed EEG examinations. Sensors, 19.","DOI":"10.3390\/s19112608"},{"key":"ref_36","unstructured":"Vilar, R. (2016). Structuring of biomaterial surfaces with ultrashort pulsed laser radiation. Laser Surface Modification of Biomaterials, Elsevier. [1st ed.]."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1111\/j.1396-0296.2004.04035.x","article-title":"Copper hypersensitivity: Dermatologic aspects","volume":"17","author":"Hostynek","year":"2004","journal-title":"Dermatol. Ther."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1109\/MPUL.2012.2216717","article-title":"The in-the-ear recording concept: User-Centered and wearable brain monitoring","volume":"3","author":"Looney","year":"2012","journal-title":"IEEE Pulse"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1088\/0967-3334\/36\/7\/1469","article-title":"Measurement of neural signals from inexpensive, wireless and dry EEG systems","volume":"36","author":"Grummett","year":"2015","journal-title":"Physiol. Meas."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.1109\/TBME.2017.2737700","article-title":"Ear-EEG-Based objective hearing threshold estimation evaluated on normal hearing subjects","volume":"65","author":"Christensen","year":"2018","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"56004","DOI":"10.1088\/1741-2552\/aa785e","article-title":"Mapping the fine structure of cortical activity with different micro-ECoG electrode array geometries","volume":"14","author":"Wang","year":"2017","journal-title":"J. Neural Eng."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/11\/3176\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:35:19Z","timestamp":1760175319000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/11\/3176"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,3]]},"references-count":41,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2020,6]]}},"alternative-id":["s20113176"],"URL":"https:\/\/doi.org\/10.3390\/s20113176","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,3]]}}}