{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T11:36:35Z","timestamp":1774438595939,"version":"3.50.1"},"reference-count":28,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2020,6,21]],"date-time":"2020-06-21T00:00:00Z","timestamp":1592697600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61771260"],"award-info":[{"award-number":["61771260"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The technology for measuring cytomembrane ion transport is one of the necessities in modern biomedical research due to its significance in the cellular physiology, the requirements for the non-invasive and easy-to-operate devices have driven lots of efforts to explore the potential electrochemical sensors. Herein, we would like to evidence the exploitation of the porous graphene oxide (PGO) decorated ion selective electrode (ISE) as a detector to capture the signal of cytomembrane ion transport. The tumor cells (MDAMB231, A549 and HeLa) treated by iodide uptake operation, with and without the sodium-iodide-symporter (NIS) expression, are used as proofs of concept. It is found that under the same optimized experimental conditions, the changed output voltages of ISEs before and after the cells\u2019 immobilization are in close relation with the NIS related ion\u2019s across-membrane transportation, including I\u2212, Na+ and Cl\u2212. The explanation for the measured results is proposed by clarifying the function of the PGO scaffold interfacial micro-environment (IME), that is, in this spongy-like micro-space, the NIS related minor ionic fluctuations can be accumulated and amplified for ISE to probe. In conclusion, we believe the integration of the microporous graphene derivatives-based IME and ISE may pave a new way for observing the cytomembrane ionic activities.<\/jats:p>","DOI":"10.3390\/s20123500","type":"journal-article","created":{"date-parts":[[2020,6,23]],"date-time":"2020-06-23T09:05:33Z","timestamp":1592903133000},"page":"3500","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Porous Graphene Oxide Decorated Ion Selective Electrode for Observing Across-Cytomembrane Ion Transport"],"prefix":"10.3390","volume":"20","author":[{"given":"Shihui","family":"Hu","sequence":"first","affiliation":[{"name":"College of Electronic Information and Optical Engineering, Nankai University, Tianjin 300071, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rong","family":"Zhang","sequence":"additional","affiliation":[{"name":"College of Electronic Information and Optical Engineering, Nankai University, Tianjin 300071, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2093-2118","authenticated-orcid":false,"given":"Yunfang","family":"Jia","sequence":"additional","affiliation":[{"name":"College of Electronic Information and Optical Engineering, Nankai University, Tianjin 300071, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,6,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1098\/rstb.2013.0092","article-title":"Ion transport and cancer: From initiation to metastasis Introduction","volume":"369","author":"Djamgoz","year":"2014","journal-title":"Philos. Trans. R. Soc. B-Biol. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.bcp.2012.05.006","article-title":"Uncoupling of K+ and Cl\u2212 transport across the cell membrane in the process of regulatory volume decrease","volume":"84","author":"Yang","year":"2012","journal-title":"Biochem. Pharmacol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1016\/0014-5793(95)00772-2","article-title":"Differential expression of voltage-activated Na+ currents in two prostatic tumour cell lines: Contribu-tion to invasiveness in vitro","volume":"369","author":"Grimes","year":"1995","journal-title":"FEBS Lett."},{"key":"ref_4","first-page":"3484","article-title":"Adenovirus-mediated transfer of the thyroid sodium\/iodide symporter gene into tumors for a targeted radio-therapy","volume":"60","author":"Boland","year":"2000","journal-title":"Cancer Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1021\/acscentsci.8b00822","article-title":"An ATP-Regulated Ion Transport Nanosystem for Homeostatic Perturbation Therapy and Sensitizing Photodynamic Therapy by Autophagy Inhibition of Tumors","volume":"5","author":"Wan","year":"2019","journal-title":"ACS Central Sci."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1152\/physrev.00044.2016","article-title":"Ion Channels in Cancer: Are Cancer Hallmarks Oncochannelopathies?","volume":"98","author":"Prevarskaya","year":"2018","journal-title":"Physiol. Rev."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.jvc.2007.02.001","article-title":"The patch clamp technique: Principles and technical considerations","volume":"9","author":"Kornreich","year":"2007","journal-title":"J. Vet. Cardio."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1146\/annurev.ph.46.030184.002323","article-title":"Patch clamp techniques for studying ionic channels in excitable membranes","volume":"46","author":"Sakmann","year":"1984","journal-title":"Annu. Rev. Physiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1038\/307468a0","article-title":"K channels in T lymphocytes: A patch clamp study using monoclonal antibody adhesion","volume":"307","author":"Matteson","year":"1984","journal-title":"Nature"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1152\/jn.1985.54.1.134","article-title":"Rectification of single GABA-gated chloride channels in adult hippocampal neurons","volume":"54","author":"Gray","year":"1985","journal-title":"J. Neurophysiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/S0014-5793(98)00590-0","article-title":"Coupling of proton source and sink via H+-migration along the membrane surface as revealed by double patch-clamp experiments","volume":"429","author":"Antonenko","year":"1998","journal-title":"FEBS Lett."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Grimm, C., Vierock, J., Hegemann, P., and Wietek, J. (2017). Whole-cell Patch-clamp Recordings for Electrophysiological Determination of Ion Selectivity in Channelrhodopsins. J. Vis. Exp., 123.","DOI":"10.3791\/55497-v"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1016\/j.bpj.2014.02.006","article-title":"Patch-Clamp Fluorometry: Electrophysiology meets Fluorescence","volume":"106","author":"Kusch","year":"2014","journal-title":"Biophys. J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1618","DOI":"10.1016\/j.bpj.2014.02.028","article-title":"Correlating Charge Movements with Local Conformational Changes of a Na+-Coupled Cotransporter","volume":"106","author":"Patti","year":"2014","journal-title":"Biophys. J."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/j.bios.2004.02.020","article-title":"Silicon chip-based patch-clamp electrodes integrated with PDMS microfluidics","volume":"20","author":"Pantoja","year":"2004","journal-title":"Biosens. Bioelectron."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.1002\/bit.23068","article-title":"Ion Channel Electrophysiology via Integrated Planar Patch-Clamp Chip with On-Demand Drug Exchange","volume":"108","author":"Chen","year":"2011","journal-title":"Biotechnol. Bioeng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1002\/(SICI)1097-0029(19990915)46:6<398::AID-JEMT8>3.0.CO;2-H","article-title":"Self-referencing, n.o.n.-i.n.v.a.s.i.v.e., ion selective electrode for single cell detection of transplasma membrane calcium flux","volume":"46","author":"Smith","year":"1999","journal-title":"Microsc. Res. Tech."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"6575","DOI":"10.1002\/adma.201302615","article-title":"Organic Electrochemical Transistor Array for Recording Transepithelial Ion Transport of Human Airway Epithelial Cells","volume":"25","author":"Yao","year":"2013","journal-title":"Adv. Mater."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.bios.2013.11.038","article-title":"Application of ion-sensitive field effect transistors for ion channel screening","volume":"54","author":"Walsh","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1021\/ac403808f","article-title":"Multielectrode Bisensor System for Time-Resolved Monitoring of Ion Transport Across an Epithelial Cell Layer","volume":"86","author":"Lewenstam","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Zajac, M., Lewenstam, A., Stobiecka, M., and Dolowy, K. (2019). New ISE-Based Apparatus for Na+, K+, Cl\u2212, pH and Transepithelial Potential Difference Real-Time Simultaneous Measurements of Ion Transport across Epithelial Cells Monolayer-Advantages and Pitfalls. Sensors, 19.","DOI":"10.3390\/s19081881"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1039\/B802710B","article-title":"Use of the thyrocyte sodium iodide symporter as the basis for a perchlorate cell-based assay","volume":"134","author":"MacAllister","year":"2009","journal-title":"Analyst"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/j.chempr.2018.02.009","article-title":"Real-Time Recording of the Cellular Effects of the Anion Transporter Prodigiosin","volume":"4","author":"Cheung","year":"2018","journal-title":"Chem"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.bios.2018.06.021","article-title":"Aptamer cell sensor based on porous graphene oxide decorated ion-selective-electrode: Double sensing platform for cell and ion","volume":"117","author":"Zhang","year":"2018","journal-title":"Biosens. Bioelectron."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Kong, T., Zhou, R., Zhang, Y., Hao, L., Cai, X., and Zhu, B. (2019). AS1411 aptamer modified carbon dots via polyethylenimine-assisted strategy for efficient targeted cancer cell imaging. Cell Prolif.","DOI":"10.1111\/cpr.12713"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1210\/er.2001-0029","article-title":"The sodium\/iodide symporter (NIS): Characterization, regulation, and medical significance","volume":"24","author":"Dohan","year":"2003","journal-title":"Endocr. Rev."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1038\/7783","article-title":"The Pendred syndrome gene encodes a chloride-iodide transport protein","volume":"21","author":"Scott","year":"1999","journal-title":"Nature Genet."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1097\/00060793-199710000-00008","article-title":"Structure and function of the thyroid iodide transporter and its implications for thyroid disease","volume":"4","author":"Levy","year":"1997","journal-title":"Curr. Opin. Endocrinol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/12\/3500\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:41:19Z","timestamp":1760175679000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/12\/3500"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,21]]},"references-count":28,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2020,6]]}},"alternative-id":["s20123500"],"URL":"https:\/\/doi.org\/10.3390\/s20123500","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,21]]}}}