{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,10]],"date-time":"2026-01-10T21:52:11Z","timestamp":1768081931262,"version":"3.49.0"},"reference-count":59,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2020,7,14]],"date-time":"2020-07-14T00:00:00Z","timestamp":1594684800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004329","name":"Javna Agencija za Raziskovalno Dejavnost RS","doi-asserted-by":"publisher","award":["P2-0032, J1-9169, and J3-1762"],"award-info":[{"award-number":["P2-0032, J1-9169, and J3-1762"]}],"id":[{"id":"10.13039\/501100004329","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This work presents a systematic approach to determining the significance of the individual factors affecting the analytical performance of in-situ film electrode (FE) for the determination of Zn(II), Cd(II), and Pb(II). Analytical parameters were considered simultaneously, where the lowest limit of quantification, the widest linear concentration range, and the highest sensitivity, accuracy, and precision of the method evidenced a better analytical method. Significance was evaluated by means of a fractional factorial (experimental) design using five factors, i.e., the mass concentrations of Bi(III), Sn(II), and Sb(III), to design the in situ FE, the accumulation potential, and the accumulation time. Next, a simplex optimization procedure was employed to determine the optimum conditions for these factors. Such optimization of the in situ FE showed significant improvement in analytical performance compared to the in situ FEs in the initial experiments and compared to pure in situ FEs (bismuth-film, tin-film, and antimony-film electrodes). Moreover, using the optimized in situ FE electrode, a possible interference effect was checked for different species and the applicability of the electrode was demonstrated for a real tap water sample.<\/jats:p>","DOI":"10.3390\/s20143921","type":"journal-article","created":{"date-parts":[[2020,7,16]],"date-time":"2020-07-16T10:54:46Z","timestamp":1594896886000},"page":"3921","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["The Use of Factorial Design and Simplex Optimization to Improve Analytical Performance of In Situ Film Electrodes"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8302-9284","authenticated-orcid":false,"given":"Matja\u017e","family":"Fin\u0161gar","sequence":"first","affiliation":[{"name":"Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Klara","family":"Jezernik","sequence":"additional","affiliation":[{"name":"Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,7,14]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3218","DOI":"10.1021\/ac000108x","article-title":"Bismuth-Coated Carbon Electrodes for Anodic Stripping Voltammetry","volume":"72","author":"Wang","year":"2000","journal-title":"Anal. Chem."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1002\/elan.200970017","article-title":"A Decade with Bismuth-Based Electrodes in Electroanalysis","volume":"22","author":"Prior","year":"2010","journal-title":"Electroanalysis"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.trac.2016.01.011","article-title":"Antimony-Based electrodes for analytical determinations","volume":"77","author":"Serrano","year":"2016","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_4","first-page":"47","article-title":"Screen-Printed carbon electrodes bulk-modified with Bi2O3 OR Sb2O3 for trace determination of some heavy metals","volume":"10","author":"Pauliukaite","year":"2004","journal-title":"Sci. Pap. Univ. Pardubic. Ser. A"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Shehata, M., Fekry, A.M., and Walcarius, A. (2020). Moxifloxacin Hydrochloride Electrochemical Detection at Gold Nanoparticles Modified Screen-Printed Electrode. Sensors, 20.","DOI":"10.3390\/s20102797"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Feng, X.-Z., Ferranco, A., Su, X., Chen, Z., Jiang, Z., and Han, G.-C. (2019). A Facile Electrochemical Sensor Labeled by Ferrocenoyl Cysteine Conjugate for the Detection of Nitrite in Pickle Juice. Sensors, 19.","DOI":"10.3390\/s19020268"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"241","DOI":"10.3390\/bios5020241","article-title":"Modified electrodes used for electrochemical detection of metal ions in environmental analysis","volume":"5","author":"March","year":"2015","journal-title":"Biosensors"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.coelec.2017.07.008","article-title":"Bismuth electrodes in contemporary electroanalysis","volume":"3","author":"Jovanovski","year":"2017","journal-title":"Curr. Opin. Electrochem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2206","DOI":"10.1016\/j.electacta.2010.12.017","article-title":"A study of in situ plated tin-film electrodes for the determination of trace metals by means of square-wave anodic stripping voltammetry","volume":"56","author":"Czop","year":"2011","journal-title":"Electrochim. Acta"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1474","DOI":"10.1021\/acssensors.0c00495","article-title":"Chip-Level Integration of Covalent Organic Frameworks for Trace Benzene Sensing","volume":"5","author":"Yuan","year":"2020","journal-title":"ACS Sens."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1002\/elan.201900432","article-title":"Effects of Humidity, Temperature and Bismuth Electrodeposition on Electroanalytical Performances of Nafion-Coated Printed Electrodes for Cd2+ and Pb2+ Detection","volume":"32","author":"Colozza","year":"2020","journal-title":"Electroanalysis"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Hou, X., Xiong, B., Wang, Y., Wang, L., and Wang, H. (2020). Determination of trace lead and cadmium in decorative material using disposable screen-printed electrode electrically modified with reduced graphene oxide\/L-cysteine\/Bi-film. Sensors, 20.","DOI":"10.3390\/s20051322"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"127715","DOI":"10.1016\/j.snb.2020.127715","article-title":"Miniature 3D-Printed integrated electrochemical cell for trace voltammetric Hg(II) determination","volume":"308","author":"Katseli","year":"2020","journal-title":"Sens. Actuators B Chem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.aca.2019.12.047","article-title":"Disposable glassy carbon stencil printed electrodes for trace detection of cadmium and lead","volume":"1103","author":"Kava","year":"2020","journal-title":"Anal. Chim. Acta"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Lo, M., Seydou, M., Bensgha\u00efer, A., Pires, R., Gningue-Sall, D., Aaron, J.J., Mekhalif, Z., Delhalle, J., and Chehimi, M.M. (2020). Polypyrrole-Wrapped carbon nanotube composite films coated on diazonium-modified flexible ITO sheets for the electroanalysis of heavy metal ions. Sensors, 20.","DOI":"10.20944\/preprints201911.0211.v2"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.jelechem.2019.03.062","article-title":"Signal amplified photoelectrochemical sensing platform with g-C3N4\/inverse opal photonic crystal WO3 heterojunction electrode","volume":"840","author":"Dang","year":"2019","journal-title":"J. Electroanal. Chem."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1007\/s00604-018-3005-1","article-title":"Two-Dimensional nanomaterial based sensors for heavy metal ions","volume":"185","author":"Gan","year":"2018","journal-title":"Microchim. Acta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"135336","DOI":"10.1016\/j.electacta.2019.135336","article-title":"Three-Dimension branched crystalline carbon nitride: A high efficiency photoelectrochemical sensor of trace Cu2+ detection","volume":"330","author":"Du","year":"2020","journal-title":"Electrochim. Acta"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1007\/s00604-017-2626-0","article-title":"Voltammetric sensing based on the use of advanced carbonaceous nanomaterials: A review","volume":"185","author":"Sinha","year":"2018","journal-title":"Microchim. Acta"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1750008","DOI":"10.1142\/S1793292017500084","article-title":"An electrochemical sensor based on graphene-polypyrrole nanocomposite for the specific detection of Pb (II)","volume":"12","author":"Rong","year":"2017","journal-title":"Nano"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Shen, X., Ju, F., Li, G., and Ma, L. (2020). Smartphone-Based Electrochemical Potentiostat Detection System Using PEDOT: PSS\/Chitosan\/Graphene Modified Screen-Printed Electrodes for Dopamine Detection. Sensors, 20.","DOI":"10.3390\/s20102781"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"104635","DOI":"10.1016\/j.microc.2020.104635","article-title":"Copper-Bismuth-Film in situ electrodes for heavy metal detection","volume":"154","year":"2020","journal-title":"Microchem. J."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2781","DOI":"10.1002\/elan.201800545","article-title":"Novel in situ Bi\u2212Sb-Film Electrodes for Trace Heavy Metal Analysis","volume":"30","author":"Petovar","year":"2018","journal-title":"Electroanalysis"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1016\/j.microc.2018.11.036","article-title":"Bismuth-Tin-Film electrodes for Zn(II), Cd(II), and Pb(II) trace analysis","volume":"145","author":"Petovar","year":"2019","journal-title":"Microchem. J."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"H108","DOI":"10.1149\/2.0191904jes","article-title":"A Comparison of Hydrochloric Acid and Acetate Buffer Media for Trace Metal Analysis Using Sb-Film Electrodes: A Detailed Electrochemical Impedance Spectroscopy Study","volume":"166","author":"Xhanari","year":"2019","journal-title":"J. Electrochem. Soc."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1016\/j.microc.2019.04.007","article-title":"Copper-film electrodes for Pb(II) trace analysis and a detailed electrochemical impedance spectroscopy study","volume":"147","author":"Xhanari","year":"2019","journal-title":"Microchem. J."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1002\/elan.201600551","article-title":"Direct Potentiometric Determination of Hydrogen Carbonate in Mineral Waters","volume":"29","author":"Dabrowska","year":"2017","journal-title":"Electroanalysis"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/j.snb.2014.07.003","article-title":"Multivariate optimization of square wave voltammetry using bismuth film electrode to determine atrazine","volume":"203","author":"Bia","year":"2014","journal-title":"Sens. Actuators B Chem."},{"key":"ref_29","unstructured":"Massart, D.L., Vandeginste, B.G.M., Buydens, L.M., Jong, S.D., Lewi, P.J., and Smeyers-Verbeke, J. (1997). Handbook of Chemometrics and Qualimetrics: Part. A, Elsevier."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/S0039-9140(03)00350-3","article-title":"A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair","volume":"61","author":"Kefala","year":"2003","journal-title":"Talanta"},{"key":"ref_31","first-page":"144","article-title":"Catalytic adsorptive stripping determination of trace chromium (VI) at the bismuth film electrode","volume":"65","author":"Lin","year":"2005","journal-title":"Talanta"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1506","DOI":"10.1016\/j.electacta.2008.09.030","article-title":"Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrode","volume":"54","author":"Tesarova","year":"2009","journal-title":"Electrochim. Acta"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1166\/asem.2013.1251","article-title":"Determination of Heavy Metal Ions on Glassy Carbon Electrode Modified with Antimony","volume":"5","author":"Bassie","year":"2013","journal-title":"Adv. Sci. Eng. Med."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"8639","DOI":"10.1021\/ac070478m","article-title":"Antimony Film Electrode for Electrochemical Stripping Analysis","volume":"79","author":"Hocevar","year":"2007","journal-title":"Anal. Chem."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.microc.2015.07.023","article-title":"Simplex optimization: A tutorial approach and recent applications in analytical chemistry","volume":"124","author":"Bezerra","year":"2016","journal-title":"Microchem. J."},{"key":"ref_36","unstructured":"\u0141ukasz, K., Yvan, V.H., and Sherma, J. (2018). Chemometrics in Chromatography, CRC Press. [1st ed.]."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.aca.2016.03.003","article-title":"New approaches to antimony film screen-printed electrodes using carbon-based nanomaterials substrates","volume":"916","author":"Serrano","year":"2016","journal-title":"Anal. Chim. Acta"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1021\/ac101626s","article-title":"Factors Controlling Stripping Voltammetry of Lead at Polycrystalline Boron Doped Diamond Electrodes: New Insights from High-Resolution Microscopy","volume":"83","author":"Hutton","year":"2011","journal-title":"Anal. Chem."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Fin\u0161gar, M., Majer, D., Maver, U., and Maver, T. (2018). Reusability of SPE and Sb-Modified SPE Sensors for Trace Pb(II) Determination. Sensors, 18.","DOI":"10.20944\/preprints201809.0555.v1"},{"key":"ref_40","unstructured":"Laboratory and Scientific Section United Nations Office on Drugs and Crime (2009). Guidance for the Validation of Analytical Methodology and Calibration of Equipment Used for Testing of Illicit Drugs in Seized Materials and Biological Specimens, A commitment to Quality and Continuous Improvement, United Nations."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1016\/j.microc.2019.02.027","article-title":"Insights into the anodic stripping voltammetric behaviour of copper film electrodes for determination of trace mercury","volume":"146","author":"Jovanovski","year":"2019","journal-title":"Microchem. J."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1016\/j.snb.2017.01.162","article-title":"Multi-Pulse galvanostatic preparation of nanostructured bismuth film electrode for trace metal detection","volume":"245","author":"Jovanovski","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.elecom.2015.04.018","article-title":"Copper film electrode for anodic stripping voltammetric determination of trace mercury and lead","volume":"57","author":"Jovanovski","year":"2015","journal-title":"Electrochem. Commun."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.aca.2020.04.033","article-title":"Biomass derived worm-like nitrogen-doped-carbon framework for trace determination of toxic heavy metal lead (II)","volume":"1116","author":"Xu","year":"2020","journal-title":"Anal. Chim. Acta"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"S\u00e1nchez-Calvo, A., Blanco-L\u00f3pez, M.C., and Costa-Garc\u00eda, A. (2020). Paper-Based Working Electrodes Coated with Mercury or Bismuth Films for Heavy Metals Determination. Biosensors, 10.","DOI":"10.3390\/bios10050052"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.snb.2019.02.106","article-title":"Synthesis of a three-dimensional (BiO)2CO3@single-walled carbon nanotube nanocomposite and its application for ultrasensitive detection of trace Pb(II) and Cd(II) by incorporating Nafion","volume":"288","author":"Zhao","year":"2019","journal-title":"Sens. Actuators B Chem."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Bedin, K.C., Mitsuyasu, E.Y., Ronix, A., Cazetta, A.L., Pezoti, O., and Almeida, V.C. (2018). Inexpensive bismuth-film electrode supported on pencil-lead graphite for determination of Pb(II) and Cd(II) Ions by anodic stripping voltammetry. Int. J. Anal. Chem., 2018.","DOI":"10.1155\/2018\/1473706"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1617","DOI":"10.1002\/elan.200900583","article-title":"Antimony Film Microelectrode for Anodic Stripping Measurement of Cadmium(II), Lead(II) and Copper(II)","volume":"22","author":"Marija","year":"2010","journal-title":"Electroanalysis"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"2584","DOI":"10.1002\/elan.200900249","article-title":"Simultaneous Determination of Trace Zinc(II) and Cadmium(II) by Differential Pulse Anodic Stripping Voltammetry Using a MWCNTs\u2013NaDBS Modified Stannum Film Electrode","volume":"21","author":"Tian","year":"2009","journal-title":"Electroanalysis"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.aca.2017.07.069","article-title":"Voltammetric determination of metal ions beyond mercury electrodes. A review","volume":"990","author":"Serrano","year":"2017","journal-title":"Anal. Chim. Acta"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1016\/j.electacta.2013.10.075","article-title":"Novel screen-printed antimony and tin voltammetric sensors for anodic stripping detection of Pb(II) and Cd(II)","volume":"114","author":"Maczuga","year":"2013","journal-title":"Electrochim. Acta"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"2321","DOI":"10.1002\/elan.200904692","article-title":"Ex Situ Prepared Antimony Film Electrode for Electrochemical Stripping Measurement of Heavy Metal Ions","volume":"21","author":"Jovanovski","year":"2009","journal-title":"Electroanalysis"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.aca.2014.12.011","article-title":"Antimony film screen-printed carbon electrode for stripping analysis of Cd(II), Pb(II), and Cu(II) in natural samples","volume":"855","author":"Sosa","year":"2015","journal-title":"Anal. Chim. Acta"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.aca.2013.04.051","article-title":"Functioning of antimony film electrode in acid media under cyclic and anodic stripping voltammetry conditions","volume":"785","author":"Sebez","year":"2013","journal-title":"Anal. Chim. Acta"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.elecom.2009.11.001","article-title":"Macroporous antimony film electrodes for stripping analysis of trace heavy metals","volume":"12","author":"Kuhn","year":"2010","journal-title":"Electrochem. Commun."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2012.03.036","article-title":"Disposable screen-printed sensors modified with bismuth precursor compounds for the rapid voltammetric screening of trace Pb(II) and Cd(II)","volume":"728","author":"Lezi","year":"2012","journal-title":"Anal. Chim. Acta"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"5294","DOI":"10.1016\/j.electacta.2008.02.079","article-title":"Lithographically fabricated disposable bismuth-film electrodes for the trace determination of Pb(II) and Cd(II) by anodic stripping voltammetry","volume":"53","author":"Kokkinos","year":"2008","journal-title":"Electrochim. Acta"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.snb.2008.08.039","article-title":"An electrochemical sensor based on the reduction of screen-printed bismuth oxide for the determination of trace lead and cadmium","volume":"135","author":"Hwang","year":"2008","journal-title":"Sens. Actuators B Chem."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.aca.2008.06.010","article-title":"Development of disposable bulk-modified screen-printed electrode based on bismuth oxide for stripping chronopotentiometric analysis of lead (II) and cadmium (II) in soil and water samples","volume":"623","author":"Kadara","year":"2008","journal-title":"Anal. Chim. Acta"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/14\/3921\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:51:31Z","timestamp":1760176291000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/14\/3921"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,14]]},"references-count":59,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2020,7]]}},"alternative-id":["s20143921"],"URL":"https:\/\/doi.org\/10.3390\/s20143921","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,14]]}}}