{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T08:57:06Z","timestamp":1773392226074,"version":"3.50.1"},"reference-count":29,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2020,7,19]],"date-time":"2020-07-19T00:00:00Z","timestamp":1595116800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Relative orientation estimation between the hand and its fingers is important in many applications, such as virtual reality (VR), augmented reality (AR) and rehabilitation. It is still quite a big challenge to do the estimation by only exploiting inertial measurement units (IMUs) because of the integration drift that occurs in most approaches. When the hand is functionally used, there are many instances in which hand and finger tips move together, experiencing almost the same angular velocities, and in some of these cases, almost the same accelerations are measured in different 3D coordinate systems. Therefore, we hypothesize that relative orientations between the hand and the finger tips can be adequately estimated using 3D IMUs during such designated events (DEs) and in between these events. We fused this extra information from the DEs and IMU data with an extended Kalman filter (EKF). Our results show that errors in relative orientation can be smaller than five degrees if DEs are constantly present and the linear and angular movements of the whole hand are adequately rich. When the DEs are partially available in a functional water-drinking task, the orientation error is smaller than 10 degrees.<\/jats:p>","DOI":"10.3390\/s20144008","type":"journal-article","created":{"date-parts":[[2020,7,20]],"date-time":"2020-07-20T10:59:38Z","timestamp":1595242778000},"page":"4008","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Estimation of Relative Hand-Finger Orientation Using a Small IMU Configuration"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9934-1240","authenticated-orcid":false,"given":"Zhicheng","family":"Yang","sequence":"first","affiliation":[{"name":"Department of Biomedical Signals Systems, Technical Medical Centre, University of Twente, 7500 AE Enschede, The Netherlands"},{"name":"School of Marine Science and Technology, Northwestern Polytechnical University, Xi\u2019an 710072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bert-Jan F.","family":"van Beijnum","sequence":"additional","affiliation":[{"name":"Department of Biomedical Signals Systems, Technical Medical Centre, University of Twente, 7500 AE Enschede, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bin","family":"Li","sequence":"additional","affiliation":[{"name":"School of Marine Science and Technology, Northwestern Polytechnical University, Xi\u2019an 710072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shenggang","family":"Yan","sequence":"additional","affiliation":[{"name":"School of Marine Science and Technology, Northwestern Polytechnical University, Xi\u2019an 710072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter H.","family":"Veltink","sequence":"additional","affiliation":[{"name":"Department of Biomedical Signals Systems, Technical Medical Centre, University of Twente, 7500 AE Enschede, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,7,19]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1109\/MCG.2002.1046630","article-title":"Real-time fingertip tracking and gesture recognition","volume":"22","author":"Oka","year":"2002","journal-title":"IEEE Comput. Graph. Appl."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1109\/TNSRE.2013.2238250","article-title":"Visuomotor discordance during visually-guided hand movement in virtual reality modulates sensorimotor cortical activity in healthy and hemiparetic subjects","volume":"21","author":"Tunik","year":"2013","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.apergo.2012.11.008","article-title":"Innovative system for real-time ergonomic feedback in industrial manufacturing","volume":"44","author":"Vignais","year":"2013","journal-title":"Appl. Ergon."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2213","DOI":"10.1016\/j.apmr.2008.04.021","article-title":"Task-specific rehabilitation of finger-hand function using interactive computer gaming","volume":"89","author":"Szturm","year":"2008","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"256","DOI":"10.12720\/ijsps.1.2.256-262","article-title":"Reviews on various inertial measurement unit (IMU) sensor applications","volume":"1","author":"Ahmad","year":"2013","journal-title":"Int. J. Signal Process. Syst."},{"key":"ref_6","first-page":"311","article-title":"An objective and standardized test of hand function","volume":"50","author":"Jebsen","year":"1969","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1191\/0269215505cr832oa","article-title":"Reliability and validity of arm function assessment with standardized guidelines for the Fugl-Meyer Test, Action Research Arm Test and Box and Block Test: A multicentre study","volume":"19","author":"Platz","year":"2005","journal-title":"Clin. Rehabil."},{"key":"ref_8","first-page":"1","article-title":"Gesture-Based Affective Computing on Motion Capture Data","volume":"Volume 3784","author":"Kapur","year":"2005","journal-title":"Proceedings of the International Conference on Affective Computing and Intelligent Interaction"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"3702","DOI":"10.3390\/s140203702","article-title":"An analysis of the precision and reliability of the leap motion sensor and its suitability for static and dynamic tracking","volume":"14","author":"Guna","year":"2014","journal-title":"Sensors"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1742","DOI":"10.1016\/j.jbiomech.2016.04.006","article-title":"Validation of the Leap Motion Controller using markered motion capture technology","volume":"49","author":"Smeragliuolo","year":"2016","journal-title":"J. Biomech."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1109\/LSP.2016.2590470","article-title":"Dynamic hand gesture recognition with leap motion controller","volume":"23","author":"Lu","year":"2016","journal-title":"IEEE Signal Process. Lett."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Mohandes, M., Aliyu, S., and Deriche, M. (2014, January 1\u20134). Arabic sign language recognition using the leap motion controller. Proceedings of the 2014 IEEE 23rd International Symposium on Industrial Electronics (ISIE), Istanbul, Turkey.","DOI":"10.1109\/ISIE.2014.6864742"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"3308","DOI":"10.1109\/TIM.2013.2272848","article-title":"Sensorized Glove for Measuring Hand Finger Flexion for Rehabilitation Purposes","volume":"62","author":"Borghetti","year":"2013","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1600136","DOI":"10.1002\/admt.201600136","article-title":"Polymer-Enhanced Highly Stretchable Conductive Fiber Strain Sensor Used for Electronic Data Gloves","volume":"1","author":"Chen","year":"2016","journal-title":"Adv. Mater. Technol."},{"key":"ref_15","unstructured":"Kaye, J., Druin, A., Lampe, C., Morris, D., and Hourcade, J.P. (2016). Finexus. CHI 2016, The Association for Computing Machinery."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1109\/TMAG.2010.2076401","article-title":"Magnetic Hand Tracking for Human-Computer Interface","volume":"47","author":"Ma","year":"2011","journal-title":"IEEE Trans. Magn."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2204","DOI":"10.1109\/TNSRE.2017.2720727","article-title":"Data Glove System Embedded With Inertial Measurement Units for Hand Function Evaluation in Stroke Patients","volume":"25","author":"Lin","year":"2017","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Chang, H.T., and Chang, J.Y. (2019). Sensor Glove based on Novel Inertial Sensor Fusion Control Algorithm for 3D Real-time Hand Gestures Measurements. IEEE Trans. Ind. Electron., 1.","DOI":"10.1109\/TIE.2019.2912765"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Salchow-H\u00f6mmen, C., Callies, L., Laidig, D., Valtin, M., Schauer, T., and Seel, T. (2019). A Tangible Solution for Hand Motion Tracking in Clinical Applications. Sensors, 19.","DOI":"10.3390\/s19010208"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"8798","DOI":"10.1016\/j.ifacol.2017.08.1534","article-title":"Eliminating the Effect of Magnetic Disturbances on the Inclination Estimates of Inertial Sensors","volume":"50","author":"Seel","year":"2017","journal-title":"IFAC-PapersOnLine"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Madgwick, S.O., Harrison, A.J., and Vaidyanathan, R. (July, January 29). Estimation of IMU and MARG orientation using a gradient descent algorithm. Proceedings of the 2011 IEEE International Conference on Rehabilitation Robotics, Zurich, Switzerland.","DOI":"10.1109\/ICORR.2011.5975346"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Teufl, W., Miezal, M., Taetz, B., Fr\u00f6hlich, M., and Bleser, G. (2018). Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics. Sensors, 18.","DOI":"10.3390\/s18071980"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Seel, T., Schauer, T., and Raisch, J. (2012, January 3\u20135). Joint axis and position estimation from inertial measurement data by exploiting kinematic constraints. Proceedings of the IEEE International Conference on Control Applications (CCA), Dubrovnik, Croatia.","DOI":"10.1109\/CCA.2012.6402423"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Laidig, D., Lehmann, D., B\u00e9gin, M.A., and Seel, T. (2019, January 23\u201327). Magnetometer-free realtime inertial motion tracking by exploitation of kinematic constraints in 2-dof joints. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany.","DOI":"10.1109\/EMBC.2019.8857535"},{"key":"ref_25","first-page":"027","article-title":"Magnetometer-free motion tracking of one-dimensional joints by exploiting kinematic constraints","volume":"1","author":"Lehmann","year":"2020","journal-title":"Proc. Autom. Med. Eng."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Tedaldi, D., Pretto, A., and Menegatti, E. (June, January 31). A robust and easy to implement method for IMU calibration without external equipments. Proceedings of the 2014 IEEE International Conference on Robotics and Automation (ICRA), Hong Kong, China.","DOI":"10.1109\/ICRA.2014.6907297"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"085202","DOI":"10.1088\/0957-0233\/19\/8\/085202","article-title":"Methods for in-field user calibration of an inertial measurement unit without external equipment","volume":"19","author":"Fong","year":"2008","journal-title":"Meas. Sci. Technol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1186\/1743-0003-11-70","article-title":"Assessment of hand kinematics using inertial and magnetic sensors","volume":"11","author":"Kortier","year":"2014","journal-title":"J. NeuroEng. Rehabil."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"223","DOI":"10.2514\/3.55767b","article-title":"Quaternion from rotation matrix","volume":"1","author":"Shepperd","year":"1978","journal-title":"J. Guid. Control"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/14\/4008\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:49:44Z","timestamp":1760176184000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/14\/4008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,19]]},"references-count":29,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2020,7]]}},"alternative-id":["s20144008"],"URL":"https:\/\/doi.org\/10.3390\/s20144008","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,19]]}}}