{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T20:36:19Z","timestamp":1784234179866,"version":"3.55.0"},"reference-count":73,"publisher":"MDPI AG","issue":"17","license":[{"start":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T00:00:00Z","timestamp":1598572800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Secondary injuries are common during upper limb rehabilitation training because of uncontrollable physical force and overexciting activities, and long-time training may cause fatigue and reduce the training effect. This study proposes a wearable monitoring device for upper limb rehabilitation by integrating electrocardiogram and electromyogram (ECG\/EMG) sensors and using data acquisition boards to obtain accurate signals during robotic glove assisting training. The collected ECG\/EMG signals were filtered, amplified, digitized, and then transmitted to a remote receiver (smart phone or laptop) via a low-energy Bluetooth module. A software platform was developed for data analysis to visualize ECG\/EMG information, and integrated into the robotic glove control module. In the training progress, various hand activities (i.e., hand closing, forearm pronation, finger flexion, and wrist extension) were monitored by the EMG sensor, and the changes in the physiological status of people (from excited to fatigue) were monitored by the ECG sensor. The functionality and feasibility of the developed physiological monitoring system was demonstrated by the assisting robotic glove with an adaptive strategy for upper limb rehabilitation training improvement. The feasible results provided a novel technique to monitor individual ECG and EMG information holistically and practically, and a technical reference to improve upper limb rehabilitation according to specific treatment conditions and the users\u2019 demands. On the basis of this wearable monitoring system prototype for upper limb rehabilitation, many ECG-\/EMG-based mobile healthcare applications could be built avoiding some complicated implementation issues such as sensors management and feature extraction.<\/jats:p>","DOI":"10.3390\/s20174861","type":"journal-article","created":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T09:17:08Z","timestamp":1598606228000},"page":"4861","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":60,"title":["Wearable Physiological Monitoring System Based on Electrocardiography and Electromyography for Upper Limb Rehabilitation Training"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0204-3819","authenticated-orcid":false,"given":"Shumi","family":"Zhao","sequence":"first","affiliation":[{"name":"Sino-German College of Intelligent Manufacturing, Shenzhen Technology University, Shenzhen 518118, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6196-5066","authenticated-orcid":false,"given":"Jianxun","family":"Liu","sequence":"additional","affiliation":[{"name":"Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hong Kong 999077, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4521-8524","authenticated-orcid":false,"given":"Zidan","family":"Gong","sequence":"additional","affiliation":[{"name":"Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hong Kong 999077, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yisong","family":"Lei","sequence":"additional","affiliation":[{"name":"Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hong Kong 999077, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xia","family":"OuYang","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, The Hong Kong Polytechnic University, Hong Kong 518118, China"},{"name":"Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN 55455, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chi Chiu","family":"Chan","sequence":"additional","affiliation":[{"name":"Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hong Kong 999077, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuangchen","family":"Ruan","sequence":"additional","affiliation":[{"name":"Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hong Kong 999077, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,8,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1109\/MMM.2015.2394021","article-title":"Wearable Wireless Health Monitoring: Current Developments, Challenges, and Future Trends","volume":"16","author":"Soh","year":"2015","journal-title":"IEEE Microw. Mag."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., and Jung, J. (2019). Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare. Nanomaterials, 9.","DOI":"10.3390\/nano9060813"},{"key":"ref_3","unstructured":"(2019, November 25). Wearable Technology Applications in Healthcare: A Literature Review. Available online: https:\/\/www.himss.org\/resources\/wearable-technology-applications-healthcare-literature-review."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Helbostad, J., Vereijken, B., Becker, C., Todd, C., Taraldsen, K., Pijnappels, M., Aminian, K., and Mellone, S. (2017). Mobile health applications to promote active and healthy ageing. Sensors, 17.","DOI":"10.3390\/s17030622"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"439","DOI":"10.3390\/polym9090439","article-title":"ECG Monitoring Garment Using Conductive Carbon Paste for Reduced Motion Artifacts","volume":"9","author":"Lee","year":"2017","journal-title":"Polymers"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1038\/s41587-019-0045-y","article-title":"Wearable biosensors for healthcare monitoring","volume":"37","author":"Kim","year":"2019","journal-title":"Nat. Biotechnol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"443","DOI":"10.3233\/THC-2010-0604","article-title":"Electrograms (ECG, EEG, EMG, EOG)","volume":"18","author":"Reilly","year":"2010","journal-title":"Technol. Health Care"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"51119","DOI":"10.1109\/ACCESS.2018.2866601","article-title":"An Approach for Noninvasive Blood Glucose Monitoring Based on Bioimpedance Difference Considering Blood Volume Pulsation","volume":"6","author":"Li","year":"2018","journal-title":"IEEE Access"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1472","DOI":"10.1109\/TBME.2012.2190288","article-title":"CNT\/PDMS composite flexible dry electrodes for long-term ECG monitoring","volume":"59","author":"Jung","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.compind.2017.06.004","article-title":"A wearable H-shirt for exercise ECG monitoring and individual lactate threshold computing","volume":"92","author":"Sun","year":"2017","journal-title":"Comput. Ind."},{"key":"ref_11","unstructured":"Li, W., Zhang, H., Wan, J., and Li, Y. (2018, January 6\u20138). A wearable exercise heart rate detection device based on single-arm ECG. Proceedings of the International Conference on Biological Information and Biomedical Engineering (BIBE 2018), Shanghai, China."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Lapkova, D., Kralik, L., and Ad\u00e1mek, M. (2016). EMG analysis for basic self-defense techniques. Computer Science On-Line Conference, Springer.","DOI":"10.1007\/978-3-319-33622-0_32"},{"key":"ref_13","unstructured":"Ali, A.A. (2012, January 23\u201325). EMG signals detection technique in voluntary muscle movement. Proceedings of the 2012 6th International Conference on New Trends in Information Science, Service Science and Data Mining (ISSDM2012), Taipei, Taiwan."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"012085","DOI":"10.1088\/1757-899X\/469\/1\/012085","article-title":"Development of wearable electromyogram (EMG) device for upper extremity in aerobic exercise","volume":"469","author":"Zulkifli","year":"2019","journal-title":"IOP Conf. Ser. Mater. Sci. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1109\/TBCAS.2015.2476555","article-title":"A Versatile Embedded Platform for EMG Acquisition and Gesture Recognition","volume":"9","author":"Benatti","year":"2015","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Pradhan, A., Nayak, S.K., Pande, K., Ray, S.S., Pal, K., Champaty, B., Anis, A., and Tibarewala, D. (2016, January 16\u201318). Acquisition and classification of EMG using a dual-channel EMG biopotential amplifier for controlling assistive devices. Proceedings of the 2016 IEEE Annual India Conference (INDICON), Bangalore, India.","DOI":"10.1109\/INDICON.2016.7839015"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Al-Jumaily, A., and Olivares, R.A. (2009, January 14\u201316). Electromyogram (EMG) driven system based virtual reality for prosthetic and rehabilitation devices. Proceedings of the 11th International Conference on Information Integration and Web-based Applications & Services, Kuala Lumpur, Malaysia.","DOI":"10.1145\/1806338.1806448"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Nazmi, N., Rahman, M.A.A., Mazlan, S.A., Zamzuri, H., and Mizukawa, M. (2015, January 30\u201331). Electromyography (EMG) based signal analysis for physiological device application in lower limb rehabilitation. Proceedings of the 2015 2nd International Conference on Biomedical Engineering (ICoBE), Penang, Malaysia.","DOI":"10.1109\/ICoBE.2015.7235878"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1007\/s11883-013-0331-y","article-title":"New evidence for therapies in stroke rehabilitation","volume":"15","author":"Dobkin","year":"2013","journal-title":"Curr. Atheroscler. Rep."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.2522\/ptj.20090081","article-title":"Factors influencing information seeking by physical therapists providing stroke management","volume":"89","author":"Salbach","year":"2009","journal-title":"Phys. Ther."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"e98","DOI":"10.1161\/STR.0000000000000098","article-title":"Guidelines for adult stroke rehabilitation and recovery: A guideline for healthcare professionals from the American Heart Association\/American Stroke Association","volume":"47","author":"Winstein","year":"2016","journal-title":"Stroke"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Martinez-Martin, E., and Cazorla, M. (2019). Rehabilitation Technology: Assistance from Hospital to Home. Comput. Intell. Neurosci., 2019.","DOI":"10.1155\/2019\/1431509"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1093\/brain\/awm311","article-title":"Robot-based hand motor therapy after stroke","volume":"131","author":"Takahashi","year":"2008","journal-title":"Brain"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1186\/1743-0003-8-63","article-title":"Effects of a robot-assisted training of grasp and pronation\/supination in chronic stroke: A pilot study","volume":"8","author":"Lambercy","year":"2011","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1016\/j.jelekin.2013.07.007","article-title":"The effects of post-stroke upper-limb training with an electromyography (EMG)-driven hand robot","volume":"23","author":"Hu","year":"2013","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1177\/1545968307311102","article-title":"Intensive sensorimotor arm training mediated by therapist or robot improves hemiparesis in patients with chronic stroke","volume":"22","author":"Volpe","year":"2008","journal-title":"Neurorehabilit. Neural Repair"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1007\/s11883-004-0064-z","article-title":"Robotics and other devices in the treatment of patients recovering from stroke","volume":"6","author":"Volpe","year":"2004","journal-title":"Curr. Atheroscler. Rep."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Thakor, N.V., and Webster, J.G. (1980). Ground-free ECG recording with two electrodes. IEEE Trans. Biomed. Eng., 699\u2013704.","DOI":"10.1109\/TBME.1980.326595"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1109\/TBME.2016.2600945","article-title":"Quantifying and reducing motion artifacts in wearable seismocardiogram measurements during walking to assess left ventricular health","volume":"64","author":"Javaid","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_30","unstructured":"Sung, M., Jeong, K., and Cho, G. (October, January 28). Suggestion for optimal location of textile-based ECG electrodes on an elastic shirts considering clothing pressure of the shirt. Proceedings of the 2008 12th IEEE International Symposium on Wearable Computers, Pittsburgh, PA, USA."},{"key":"ref_31","unstructured":"Retamosa, J.D.T., Araujo, A., and Wawrzyniak, Z.M. (2018, January 3\u201310). Low power wearable device for elderly people monitoring. Proceedings of the Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments 2018, Wilga, Poland."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Liu, J., and Zhou, Y. (2013, January 28\u201329). Design of a novel portable ECG monitor for heart health. Proceedings of the 2013 Sixth International Symposium on Computational Intelligence and Design, Hangzhou, China.","DOI":"10.1109\/ISCID.2013.178"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Tosi, J., Taffoni, F., Santacatterina, M., Sannino, R., and Formica, D. (2017). Performance evaluation of Bluetooth low energy: A systematic review. Sensors, 17.","DOI":"10.3390\/s17122898"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Song, W., Yu, H., Liang, C., Wang, Q., and Shi, Y. (November, January 30). Body monitoring system design based on android smartphone. Proceedings of the 2012 World Congress on Information and Communication Technologies, Trivandrum, India.","DOI":"10.1109\/WICT.2012.6409247"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Ai, Z., Zheng, L., Qi, H., and Cui, W. (2018, January 25\u201327). Low-Power Wireless Wearable ECG Monitoring System Based on BMD101. Proceedings of the 2018 37th Chinese Control Conference (CCC), Wuhan, China.","DOI":"10.23919\/ChiCC.2018.8484125"},{"key":"ref_36","unstructured":"Wang, J.-S., Zhang, Y., Zhang, P., and Sun, S.-F. (2010, January 29\u201331). Research on denoising algorithm for ECG signals. Proceedings of the 29th Chinese Control Conference, Beijing, China."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Imtiaz, U., Bartolomeo, L., Lin, Z., Sessa, S., Ishii, H., Saito, K., Zecca, M., and Takanishi, A. (2013, January 4\u20137). Design of a wireless miniature low cost EMG sensor using gold plated dry electrodes for biomechanics research. Proceedings of the 2013 IEEE International Conference on Mechatronics and Automation, Takamatsu, Japan.","DOI":"10.1109\/ICMA.2013.6618044"},{"key":"ref_38","unstructured":"Perotto, A.O. (2011). Anatomical Guide for the Electromyographer: The Limbs and Trunk, Charles C Thomas Publisher. [5th ed.]."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Choi, C., and Kim, J. (2007, January 13\u201315). A real-time EMG-based assistive computer interface for the upper limb disabled. Proceedings of the 2007 IEEE 10th International Conference on Rehabilitation Robotics, Noordwijk, The Netherlands.","DOI":"10.1109\/ICORR.2007.4428465"},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Weiss, L.D., Weiss, J.M., and Silver, J.K. (2015). Easy EMG E-Book: A Guide to Performing Nerve Conduction Studies and Electromyography, Elsevier. [2nd ed.].","DOI":"10.1016\/B978-0-323-28664-0.00004-7"},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Webster, J.G. (1984). Reducing motion artifacts and interference in biopotential recording. IEEE Trans. Biomed. Eng., 823\u2013826.","DOI":"10.1109\/TBME.1984.325244"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1088\/0967-3334\/21\/2\/307","article-title":"A direct comparison of wet, dry and insulating bioelectric recording electrodes","volume":"21","author":"Searle","year":"2000","journal-title":"Physiol. Meas."},{"key":"ref_43","unstructured":"(2020, August 28). A designer\u2019s Guide to Instrumentation Amplifiers. Available online: https:\/\/d1.amobbs.com\/bbs_upload782111\/files_3\/armok0169547.pdf."},{"key":"ref_44","unstructured":"(2020, August 28). Important Factors in Surface EMG Measurement. Available online: https:\/\/pdfs.semanticscholar.org\/33f2\/f59c47d28387533208284d1991e12fed18bd.pdf."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.jneumeth.2003.10.014","article-title":"A method for positioning electrodes during surface EMG recordings in lower limb muscles","volume":"134","author":"Rainoldi","year":"2004","journal-title":"J. Neurosci. Methods"},{"key":"ref_46","first-page":"2","article-title":"Getting the most out of your instrumentation amplifier design","volume":"1","author":"Kugelstadt","year":"2005","journal-title":"SAT"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Saad, I., Bais, N.H., and Bolong, N. (2015, January 2\u20134). Electromyogram (emg) signal processing analysis for clinical rehabilitation application. Proceedings of the 2015 3rd International Conference on Artificial Intelligence, Modelling and Simulation (AIMS), Kota Kinabalu, Malaysia.","DOI":"10.1109\/AIMS.2015.76"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1251\/bpo115","article-title":"Techniques of EMG signal analysis: Detection, processing, classification and applications","volume":"8","author":"Reaz","year":"2006","journal-title":"Biol. Proced. Online"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Polygerinos, P., Galloway, K.C., Savage, E., Herman, M., O\u2019Donnell, K., and Walsh, C.J. (2015, January 26\u201330). Soft robotic glove for hand rehabilitation and task specific training. Proceedings of the 2015 IEEE international conference on robotics and automation (ICRA), Seattle, WA, USA.","DOI":"10.1109\/ICRA.2015.7139597"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s12984-018-0350-6","article-title":"Soft robotic devices for hand rehabilitation and assistance: A narrative review","volume":"15","author":"Chu","year":"2018","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_51","first-page":"S795","article-title":"Study on upper limb rehabilitation system based on surface EMG","volume":"26","author":"Wang","year":"2015","journal-title":"Biomed. Mater. Eng."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Qin, J., Li, C., Chen, Z., and Jia, J. (2014, January 15\u201317). 3 DOF upper limb rehabilitation robot-assisted training system. Proceedings of the 2014 International Conference on Mechatronics, Electronic, Industrial and Control Engineering (MEIC-14), Shenyang, China.","DOI":"10.2991\/meic-14.2014.82"},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Deepu, C.J., Zhang, X., Wong, D., and Lian, Y. (2016, January 22\u201325). An ECG-on-chip with joint QRS detection & data compression for wearable sensors. Proceedings of the 2016 IEEE International Symposium on Circuits and Systems (ISCAS), Montreal, QC, Canada.","DOI":"10.1109\/ISCAS.2016.7539211"},{"key":"ref_54","unstructured":"Strasser, F., Muma, M., and Zoubir, A.M. (2012, January 27\u201331). Motion artifact removal in ECG signals using multi-resolution thresholding. Proceedings of the 2012 Proceedings of the 20th European Signal Processing Conference (EUSIPCO), Bucharest, Romania."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"67","DOI":"10.5405\/jmbe.676","article-title":"Motion artifact reduction in electrocardiogram using adaptive filter","volume":"31","author":"Liu","year":"2011","journal-title":"J. Med. Biol. Eng."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1002\/clc.20709","article-title":"Fragmented QRS complex: A novel marker of cardiovascular disease","volume":"33","author":"Chatterjee","year":"2010","journal-title":"Clin. Cardiol."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"2183","DOI":"10.1016\/j.jacc.2005.01.071","article-title":"Significance of QRS complex duration in patients with heart failure","volume":"46","author":"Kashani","year":"2005","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1080\/10615800512331328777","article-title":"Self-implication and heart rate variability during simulated exposure to flight-related stimuli","volume":"17","author":"Bornas","year":"2004","journal-title":"Anxiety Stress Coping"},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Choi, U.S., Kim, K.-J., Lee, S.-S., Kim, K.-S., and Kim, J. (2016). A Simple Fatigue Condition Detection Method by Using Heart Rate Variability Analysis, Springer.","DOI":"10.1007\/978-981-10-0068-3_27"},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"Kurian, D., Joseph, J., Radhakrishnan, K., and Balakrishnan, A.A. (2014, January 27\u201329). Drowsiness Detection Using Photoplethysmography Signal. Proceedings of the 2014 Fourth International Conference on Advances in Computing and Communications, Kochi, India.","DOI":"10.1109\/ICACC.2014.23"},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Lin, Y.-H., Lin, C.-F., and You, H.-Z. (2011). A driver\u2019s physiological monitoring system based on a wearable PPG sensor and a smartphone. International Conference on Security-Enriched Urban Computing and Smart Grid, Springer.","DOI":"10.1007\/978-3-642-23948-9_36"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.artmed.2008.04.007","article-title":"Support vector machine-based arrhythmia classification using reduced features of heart rate variability signal","volume":"44","author":"Asl","year":"2008","journal-title":"Artif. Intell. Med."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1109\/TITB.2008.2003323","article-title":"Heartbeat time series classification with support vector machines","volume":"13","author":"Kampouraki","year":"2008","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"ref_64","first-page":"17","article-title":"Bio-medical (EMG) Signal Analysis and Feature Extraction Using Wavelet Transform","volume":"5","author":"Raut","year":"2015","journal-title":"Int. J. Eng. Res. Appl."},{"key":"ref_65","unstructured":"Mahaphonchaikul, K., Sueaseenak, D., Pintavirooj, C., Sangworasil, M., and Tungjitkusolmun, S. (2010, January 19\u201321). EMG signal feature extraction based on wavelet transform. Proceedings of the The 2010 ECTI International Confernce on Electrical Engineering\/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON2010), Chiang Mai, Thailand."},{"key":"ref_66","doi-asserted-by":"crossref","unstructured":"Zhao, S., Liu, R., Fei, C., and Guan, D. (2019). Dynamic Interface Pressure Monitoring System for the Morphological Pressure Mapping of Intermittent Pneumatic Compression Therapy. Sensors, 19.","DOI":"10.3390\/s19132881"},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Octavia, J.R., and Coninx, K. (2014). Adaptive personalized training games for individual and collaborative rehabilitation of people with multiple sclerosis. BioMed Res. Int., 2014.","DOI":"10.1155\/2014\/345728"},{"key":"ref_68","doi-asserted-by":"crossref","unstructured":"Wen, Y., Liu, M., Si, J., and Huang, H.H. (2016, January 16\u201320). Adaptive control of powered transfemoral prostheses based on adaptive dynamic programming. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7591867"},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Weinberg, B., Nikitczuk, J., Patel, S., Patritti, B., Mavroidis, C., Bonato, P., and Canavan, P. (2007, January 10\u201314). Design, control and human testing of an active knee rehabilitation orthotic device. Proceedings of the 2007 IEEE International Conference on Robotics and Automation, Roma, Italy.","DOI":"10.1109\/ROBOT.2007.364113"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1109\/TNSRE.2005.863839","article-title":"Adaptive force regulation of muscle strengthening rehabilitation device with magnetorheological fluids","volume":"14","author":"Dong","year":"2006","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"2323","DOI":"10.1589\/jpts.27.2323","article-title":"Muscle activity, time to fatigue, and maximum task duration at different levels of production standard time","volume":"27","author":"Nur","year":"2015","journal-title":"J. Phys. Ther. Sci."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"1450006","DOI":"10.1142\/S0129065714500063","article-title":"Detection of driving fatigue by using noncontact EMG and ECG signals measurement system","volume":"24","author":"Fu","year":"2014","journal-title":"Int. J. Neural. Syst."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"184","DOI":"10.3389\/fneur.2013.00184","article-title":"Neurophysiology of robot-mediated training and therapy: A perspective for future use in clinical populations","volume":"4","author":"Turner","year":"2013","journal-title":"Front. Neurol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/17\/4861\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:04:01Z","timestamp":1760177041000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/17\/4861"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,28]]},"references-count":73,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2020,9]]}},"alternative-id":["s20174861"],"URL":"https:\/\/doi.org\/10.3390\/s20174861","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,28]]}}}