{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T21:47:17Z","timestamp":1767649637619,"version":"build-2065373602"},"reference-count":38,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2020,9,10]],"date-time":"2020-09-10T00:00:00Z","timestamp":1599696000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"German Federal Ministry for Economic Affairs and Energy","award":["03THW12K12"],"award-info":[{"award-number":["03THW12K12"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this paper, a smart detector design for novel multi-plane ultrafast electron beam X-ray computed tomography is presented. The concept is based on multi-plane electron beam scanning on a transparent X-ray target and elongated cuboid-shape scintillation detectors for radiation detection over an extended axial scanning range. The optical part of the scintillation detector acts as both an X-ray sensitive scintillator with a fast time response and a light guide. With that, we reduce detector complexity, number of detector elements, overall power consumption, and detector costs. We investigated the performance of this new multi-plane detector design with an evaluation detector setup that is made of cerium doped lutetium yttrium oxyorthosilicate (LYSO:Ce) as scintillation material and an avalanche photodiode (APD) array. Thereby, we assessed two design variants: A monolithic LYSO bar detector and a sandwich detector made of multiple LYSO crystals and glass light-guides. Both types reveal excellent linear detector responses, long-term stabilities, and comparable signal qualities.<\/jats:p>","DOI":"10.3390\/s20185174","type":"journal-article","created":{"date-parts":[[2020,9,10]],"date-time":"2020-09-10T22:58:01Z","timestamp":1599778681000},"page":"5174","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["A Smart Multi-Plane Detector Design for Ultrafast Electron Beam X-ray Computed Tomography"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3428-5019","authenticated-orcid":false,"given":"Andr\u00e9","family":"Bieberle","sequence":"first","affiliation":[{"name":"Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstra\u00dfe 400, 01328 Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3558-5750","authenticated-orcid":false,"given":"Dominic","family":"Windisch","sequence":"additional","affiliation":[{"name":"Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstra\u00dfe 400, 01328 Dresden, Germany"},{"name":"Chair of Imaging Techniques in Energy and Process Engineering, Technische Universit\u00e4t Dresden, 01062 Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kerolos","family":"Iskander","sequence":"additional","affiliation":[{"name":"Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstra\u00dfe 400, 01328 Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2195-6012","authenticated-orcid":false,"given":"Martina","family":"Bieberle","sequence":"additional","affiliation":[{"name":"Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstra\u00dfe 400, 01328 Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Uwe","family":"Hampel","sequence":"additional","affiliation":[{"name":"Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstra\u00dfe 400, 01328 Dresden, Germany"},{"name":"Chair of Imaging Techniques in Energy and Process Engineering, Technische Universit\u00e4t Dresden, 01062 Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,9,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2213","DOI":"10.1088\/0957-0233\/16\/11\/012","article-title":"Imaging of liquid distribution in reactive distillation packings with a new high-energy X-ray tomograph","volume":"16","author":"Toye","year":"2005","journal-title":"Meas. Sci. Technol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1080\/00986449908912143","article-title":"Modelling of the liquid distribution in a trickle flow packed column based upon X-ray tomography images","volume":"175","author":"Toye","year":"1999","journal-title":"Chem. Eng. Commun."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"5734","DOI":"10.1021\/ie0701827","article-title":"Novel application of X-ray computed tomography: Determination of gas\/liquid contact area and liquid holdup in structured packing","volume":"46","author":"Green","year":"2007","journal-title":"Ind. Eng. Chem. Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1016\/j.cep.2009.02.001","article-title":"Phase distribution measurements in metallic foam packing using X-ray radiography and micro-tomography","volume":"48","author":"Calvo","year":"2009","journal-title":"Chem. Eng. Process. Process. Intensif."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ces.2015.08.015","article-title":"Qualitative and quantitative insights into multiphase flow in ceramic sponges using X-ray computed tomography","volume":"138","author":"Wallenstein","year":"2015","journal-title":"Chem. Eng. Sci."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.apradiso.2009.09.004","article-title":"Flow imaging by high speed transmission tomography","volume":"68","author":"Johansen","year":"2010","journal-title":"Appl. Radiat. Isot."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.nima.2007.11.020","article-title":"High resolution synchrotron-based radiography and tomography using hard X-rays at the BAMline (BESSY II)","volume":"586","author":"Rack","year":"2008","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1978","DOI":"10.1016\/j.nimb.2009.04.002","article-title":"The micro-imaging station of the TopoTomo beamline at the ANKA synchrotron","volume":"267","author":"Rack","year":"2009","journal-title":"Nucl. Instrum. Methods Phys. Res. B"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1768","DOI":"10.1007\/s00348-014-1768-7","article-title":"Synchrotron radiation microtomography of Taylor bubbles in capillary two-phase flow","volume":"55","author":"Boden","year":"2014","journal-title":"Exp. Fluids"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"690706","DOI":"10.1017\/jfm.2015.375","article-title":"High-speed X-ray imaging of a ball impacting on loose sand","volume":"777","author":"Homan","year":"2015","journal-title":"J. Fluid Mech."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2089","DOI":"10.1109\/23.708308","article-title":"Development of ultra-fast X-ray computed tomography scanner system","volume":"45","author":"Hori","year":"1998","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1515\/kern-2003-0046","article-title":"Ultra-fast X-ray tomography for multi-phase flow interface dynamic studies","volume":"68","author":"Misawa","year":"2003","journal-title":"Kerntechnik"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1109\/23.775548","article-title":"Development of a high speed X-ray tomography system for multiphase flow imaging","volume":"46","author":"Morton","year":"1999","journal-title":"Ieee Trans. Nucl. Sci."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"094002","DOI":"10.1088\/0957-0233\/19\/9\/094002","article-title":"An ultra fast electron beam x-ray tomography scanner","volume":"19","author":"Fischer","year":"2008","journal-title":"Meas. Sci. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1109\/PROC.1983.12588","article-title":"Cardiac Computed Tomography","volume":"71","author":"Boyd","year":"1983","journal-title":"P. IEEE."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2254","DOI":"10.1016\/j.nucengdes.2009.11.016","article-title":"Ultrafast electron beam X-ray computed tomography for two-phase flow measurement","volume":"240","author":"Fischer","year":"2010","journal-title":"Nucl. Eng. Des."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"103340","DOI":"10.1016\/j.ijmultiphaseflow.2020.103340","article-title":"Investigations on bubbly two-phase flow in a constricted vertical pipe","volume":"130","author":"Bieberle","year":"2020","journal-title":"Int. J. Multiph. Flow"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"60","DOI":"10.3139\/124.110316","article-title":"Experimental investigations of single and two-phase flow in a heated rod bundle","volume":"78","author":"Barthel","year":"2013","journal-title":"Kerntechnik"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.cep.2013.01.008","article-title":"Investigation of dynamic liquid distribution and hold-up in structured packings using ultrafast electron beam X-ray tomography","volume":"66","author":"Janzen","year":"2013","journal-title":"Chem. Eng. Process. Process. Intensif."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1016\/j.ces.2017.05.011","article-title":"Hydrodynamics of descending gas-liquid flows in solid foams: Liquid holdup, multiphase pressure drop and radial dispersion","volume":"168","author":"Zalucky","year":"2017","journal-title":"Chem. Eng. Sci."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1016\/j.cej.2014.09.019","article-title":"Visualization and quantitative analysis of dispersive mixing by a helical static mixer in upward co-current gas-liquid flow","volume":"262","author":"Rabha","year":"2015","journal-title":"Chem. Eng. J."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.ijmultiphaseflow.2016.07.008","article-title":"A study of two-phase flow in monoliths using ultrafast single-slice X-ray computed tomography","volume":"86","author":"Meitzner","year":"2016","journal-title":"Int. J. Multiph. Flow"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.cej.2015.10.003","article-title":"Combined phase distribution and particle velocity measurement in spout fluidized beds by ultrafast X-ray computed tomography","volume":"285","author":"Bieberle","year":"2016","journal-title":"Chem. Eng. J."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.flowmeasinst.2009.12.001","article-title":"Dual-plane ultrafast limited-angle electron beam x-ray tomography","volume":"21","author":"Bieberle","year":"2010","journal-title":"Flow Meas. Instrum."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.flowmeasinst.2015.06.006","article-title":"Velocity measurement for two-phase flows based on ultrafast x-ray tomography","volume":"46","author":"Barthel","year":"2015","journal-title":"Flow Meas. Instrum."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"084001","DOI":"10.1088\/1361-6501\/ab1ba2","article-title":"Improved axial plane distance and velocity determination for ultrafast electron beam X-ray computed tomography","volume":"30","author":"Neumann","year":"2019","journal-title":"Meas. Sci. Technol."},{"key":"ref_27","first-page":"023702","article-title":"Experimental facility for two- and three-dimensional ultrafast electron beam x-ray computed tomography","volume":"82","author":"Bieberle","year":"2010","journal-title":"Rev. Sci. Instrum."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.nima.2011.01.075","article-title":"Transparent target for ultrafast electron beam tomography","volume":"635","author":"Hampel","year":"2011","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_29","unstructured":"Kak, A., and Slaney, M. (1988). Principles of Computerized Tomographic Imaging, IEEE Press."},{"key":"ref_30","unstructured":"Bieberle, M., St\u00fcrzel, T., Hampel, U., and Laurien, E. (2013, January 2\u20135). Ultrafast 3D X-ray tomography of a wire-mesh sensor in operation in a two-phase flow. Proceedings of the 7th World Congress on Industrial Process Tomography, WCIPT7, Krakow, Poland."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/j.nima.2006.12.034","article-title":"Design of a high-resolution gamma-ray detector module for tomography applications","volume":"572","author":"Bieberle","year":"2007","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_32","unstructured":"Crystals, S.G. (2006). Physical Properties of Common Inorganic Scintillators, Saint-Gobain Crystals."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s10967-019-06442-8","article-title":"Study on the mechanism of afterglow in CsI: Tl and the afterglow suppression in CsI: Tl, Eu","volume":"320","author":"Tian","year":"2019","journal-title":"J. Radioanal. Nucl. Chem."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Kappers, L.A., Bartram, R.H., Hamilton, D.S., Lempicki, A., Brecher, C., Gaysinskiy, V., Ovechkina, E.E., and Nagarkar, V.V. (2010, January 12\u201316). Scintillation, Afterglow and Thermoluminescence of CsI:Tl, Sm IOP Conference Series: Materials Science and Engineering 15. Proceedings of the 11th Europhysical Conference on Defects in Insulating Materials (EURODIM 2010), P\u00e9cs, Hungary.","DOI":"10.1088\/1757-899X\/15\/1\/012091"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Grupen, C., and Buvat, I. (2012). Radiation Damage Effects. Handbook of Particle Detection and Imaging, Springer.","DOI":"10.1007\/978-3-642-13271-1"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"P04004","DOI":"10.1088\/1748-0221\/4\/04\/P04004","article-title":"Advances in solid state photon detectors","volume":"4","author":"Renker","year":"2009","journal-title":"J. Instrum."},{"key":"ref_37","unstructured":"Hamamatsu Photonics, K.K. (2020, August 06). Datasheet: Si APD array \u2013S8550-02, 4x8 Element APD Array with Low Noise and Enhanced Short-Wavelength Sensitivity. Available online: https:\/\/www.hamamatsu.com\/resources\/pdf\/ssd\/s8550-02_kapd1031e.pdf."},{"key":"ref_38","unstructured":"Saint-Gobain Ceramics & Plastics (2020, August 06). Datasheet: LYSO Scintillation Material. Available online: https:\/\/www.crystals.saint-gobain.com\/sites\/imdf.crystals.com\/files\/documents\/lyso-material-data-sheet.pdf."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/18\/5174\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:08:49Z","timestamp":1760177329000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/18\/5174"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,10]]},"references-count":38,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2020,9]]}},"alternative-id":["s20185174"],"URL":"https:\/\/doi.org\/10.3390\/s20185174","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2020,9,10]]}}}