{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T11:38:00Z","timestamp":1782128280095,"version":"3.54.5"},"reference-count":118,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2020,9,12]],"date-time":"2020-09-12T00:00:00Z","timestamp":1599868800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Biosensors based on magneto-impedance (MI) effect are powerful tools for biomedical applications as they are highly sensitive, stable, exhibit fast response, small in size, and have low hysteresis and power consumption. However, the performance of these biosensors is influenced by a variety of factors, including the design, geometry, materials and fabrication procedures. Other less appreciated factors influencing the MI effect include measuring circuit implementation, the material used for construction, geometry of the thin film sensing element, and patterning shapes compatible with the interface microelectronic circuitry. The type magnetic (ferrofluid, Dynabeads, and nanoparticles) and size of the particles, the magnetic particle concentration, magnetic field strength and stray magnetic fields can also affect the sensor sensitivity. Based on these considerations it is proposed that ideal MI biosensor sensitivity could be achieved when the sensor is constructed in sandwich thick magnetic layers with large sensing area in a meander shape, measured with circuitry that provides the lowest possible external inductance at high frequencies, enclosed by a protective layer between magnetic particles and sensing element, and perpendicularly magnetized when detecting high-concentration of magnetic particles.<\/jats:p>","DOI":"10.3390\/s20185213","type":"journal-article","created":{"date-parts":[[2020,9,13]],"date-time":"2020-09-13T21:11:32Z","timestamp":1600031492000},"page":"5213","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["Magneto-Impedance Biosensor Sensitivity: Effect and Enhancement"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7729-0240","authenticated-orcid":false,"given":"Abkar","family":"Sayad","sequence":"first","affiliation":[{"name":"Department of Neuroscience, The Alfred Centre, Central Clinical School, Monash University, Melbourne, Victoria 3004, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Efstratios","family":"Skafidas","sequence":"additional","affiliation":[{"name":"Department of Electrical and Electronic Engineering, Melbourne School of Engineering, The University of Melbourne, Victoria 3010, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Kwan","sequence":"additional","affiliation":[{"name":"Department of Neuroscience, The Alfred Centre, Central Clinical School, Monash University, Melbourne, Victoria 3004, Australia"},{"name":"Department of Electrical and Electronic Engineering, Melbourne School of Engineering, The University of Melbourne, Victoria 3010, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,9,12]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1189","DOI":"10.1063\/1.112104","article-title":"Magneto-impedance effect in amorphous wires","volume":"65","author":"Panina","year":"1994","journal-title":"Appl. Phys. Lett."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"3652","DOI":"10.1063\/1.111170","article-title":"Giant magnetic field dependent impedance of amorphous FeCoSiB wire","volume":"64","author":"Beach","year":"1994","journal-title":"Appl. Phys. Lett."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1080\/14786448708628000","article-title":"XXV. Notes on electricity and magnetism\u2014III. On the behaviour of iron and steel under the operation of feeble magnetic forces","volume":"23","author":"Rayleigh","year":"1887","journal-title":"Lond. Edinb. Dubl. Phil. Mag."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1103\/PhysRev.70.281","article-title":"Theory of the dispersion of magnetic permeability in ferromagnetic materials at microwave frequencies","volume":"70","author":"Kittel","year":"1946","journal-title":"Phys. Rev."},{"key":"ref_5","unstructured":"Sommerfeld, A. (1952). Electrodynamics: Lectures on Theoretical Physic, Elsevier."},{"key":"ref_6","unstructured":"Landau, L.D., Bell, J., Kearsley, M., Pitaevskii, L., Lifshitz, E., and Sykes, J. (2013). Electrodynamics of Continuous Media, Elsevier."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1906","DOI":"10.1109\/20.764884","article-title":"AC impedance and circular permeability of slab and cylinder","volume":"35","author":"Chen","year":"1999","journal-title":"IEEE Trans. Magn."},{"key":"ref_8","unstructured":"Cullity, B.D., and Graham, C.D. (2011). Introduction to Magnetic Materials, John Wiley and Sons."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Garc\u00eda-Arribas, A., Fern\u00e1ndez, E., and Cos, D. (2017). Thin-film magneto-impedance sensors. Magnetic Sensors-Development Trends and Applications, InTech.","DOI":"10.5772\/intechopen.70084"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.jcis.2016.01.061","article-title":"A universal magnetic ferrofluid: Nanomagnetite stable hydrosol with no added dispersants and at neutral pH","volume":"468","author":"Drozdov","year":"2016","journal-title":"J. Colloid Interface Sci."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1380","DOI":"10.1016\/j.bios.2004.06.004","article-title":"Preparation of inert magnetic nano-particles for the directed immobilization of antibodies","volume":"20","author":"Fuentes","year":"2005","journal-title":"Biosens. Bioelectron."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1016\/j.bios.2016.05.052","article-title":"Comparison of two fabricated aptasensors based on modified carbon paste\/oleic acid and magnetic bar carbon paste\/Fe3O4@oleic acid nanoparticle electrodes for tetracycline detection","volume":"85","author":"Jahanbani","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.aca.2012.05.043","article-title":"Magnetic Fe3O4@Au composite-enhanced surface plasmon resonance for ultrasensitive detection of magnetic nanoparticle-enriched \u03b1-fetoprotein","volume":"737","author":"Liang","year":"2012","journal-title":"Anal. Chim. Acta"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"15482","DOI":"10.1039\/c2cp42415k","article-title":"A spectroscopic investigation on the interaction of a magnetic ferrofluid with a model plasma protein: Effect on the conformation and activity of the protein","volume":"14","author":"Paul","year":"2012","journal-title":"Phys. Chem. Chem. Phys."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.bios.2016.05.023","article-title":"Lab-on-a-disc agglutination assay for protein detection by optomagnetic readout and optical imaging using nano- and micro-sized magnetic beads","volume":"85","author":"Uddin","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"20919","DOI":"10.1021\/jp4050786","article-title":"Improved Stability and Relaxivity of a Commercial Magnetic Ferrofluid","volume":"117","author":"Pflipsen","year":"2013","journal-title":"J. Phys. Chem. C"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.aca.2008.06.042","article-title":"Improvement of surface plasmon resonance biosensor with magnetic beads via assembled polyelectrolyte layers","volume":"624","author":"Sun","year":"2008","journal-title":"Anal. Chim. Acta."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.bios.2016.04.006","article-title":"Magnetic immunoassay for cancer biomarker detection based on surface-enhanced resonance Raman scattering from coupled plasmonic nanostructures","volume":"84","author":"Rong","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.bios.2014.10.025","article-title":"Chemiluminescence resonance energy transfer imaging on magnetic particles for single-nucleotide polymorphism detection based on ligation chain reaction","volume":"65","author":"Bi","year":"2015","journal-title":"Biosens. Bioelectron."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1007\/s00253-006-0675-0","article-title":"Magnetic particles for the separation and purification of nucleic acids","volume":"73","author":"Berensmeier","year":"2006","journal-title":"Appl. Microbiol. Biotechnol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"964","DOI":"10.1126\/science.1131475","article-title":"Low-field magnetic separation of monodisperse Fe3O4 nanocrystals","volume":"314","author":"Yavuz","year":"2006","journal-title":"Science"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/S0956-5663(98)00037-2","article-title":"A biosensor based on magnetoresistance technology","volume":"13","author":"Baselt","year":"1998","journal-title":"Biosens. Bioelectron."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1016\/S0956-5663(01)00241-X","article-title":"A novel measuring system for the determination of paramagnetic particle labels for use in magneto-immunoassays","volume":"16","author":"Richardson","year":"2001","journal-title":"Biosens. Bioelectron."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1016\/j.bios.2004.04.023","article-title":"Planar coil excitation of multifrequency shear wave transducers","volume":"20","author":"Stevenson","year":"2005","journal-title":"Biosens. Bioelectron."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2248","DOI":"10.1016\/j.bios.2005.11.008","article-title":"A combination of magnetic permeability detection with nanometer-scaled superparamagnetic tracer and its application for one-step detection of human urinary albumin in undiluted urine","volume":"21","author":"Lu","year":"2006","journal-title":"Biosens. Bioelectron."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1390","DOI":"10.1002\/mrm.28004","article-title":"Dehydration assessment via a portable, single sided magnetic resonance sensor","volume":"83","author":"Bashyam","year":"2020","journal-title":"Magn. Reson. Med."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1628","DOI":"10.1016\/j.jmmm.2009.02.101","article-title":"Binding assays with streptavidin-functionalized superparamagnetic nanoparticles and biotinylated analytes using fluxgate magnetorelaxometry","volume":"321","author":"Heim","year":"2009","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_28","unstructured":"Schulz, G., Kasper, A., Gavagnin, M., Lenzhofer, M., and Ortner, M. (2020). Component Carrier With Integrated Flux Gate Sensor. (US20200041582A1), Google Patents."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"4729","DOI":"10.1063\/1.1759380","article-title":"Planar Hall effect sensor for magnetic micro-and nanobead detection","volume":"84","author":"Ejsing","year":"2004","journal-title":"Appl. Phys. Lett."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"153903","DOI":"10.1063\/1.3122142","article-title":"Magnetic bead counter using a micro-Hall sensor for biological applications","volume":"94","author":"Lee","year":"2009","journal-title":"Appl. Phys. Lett."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"07E513","DOI":"10.1063\/1.3678322","article-title":"Modelling and optimization of submicron Hall sensors for the detection of superparamagnetic beads","volume":"111","author":"Manzin","year":"2012","journal-title":"J. Appl. Phys."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.bios.2014.03.021","article-title":"Planar Hall magnetoresistive aptasensor for thrombin detection","volume":"59","author":"Sinha","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1016\/S0304-8853(00)01242-7","article-title":"A DNA array sensor utilizing magnetic microbeads and magnetoelectronic detection","volume":"225","author":"Miller","year":"2001","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/S0924-4247(03)00380-7","article-title":"Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors","volume":"107","author":"Rife","year":"2003","journal-title":"Sens. Actuator A Phys."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1038\/nm.2032","article-title":"Matrix-insensitive protein assays push the limits of biosensors in medicine","volume":"15","author":"Gaster","year":"2009","journal-title":"Nat. Med."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"2177","DOI":"10.1016\/j.bios.2010.01.039","article-title":"GMR biosensor arrays: Correction techniques for reproducibility and enhanced sensitivity","volume":"25","author":"Hall","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.bios.2013.03.016","article-title":"Conditions for efficient on-chip magnetic bead detection via magnetoresistive sensors","volume":"47","author":"Albisetti","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Giraud, M., Delapierre, F.-D., Wijkhuisen, A., Bonville, P., Th\u00e9venin, M., Cannies, G., Plaisance, M., Paul, E., Ezan, E., and Simon, S. (2019). Evaluation of in-flow magnetoresistive chip cell-counter as a diagnostic tool. Biosensors, 9.","DOI":"10.3390\/bios9030105"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"173701","DOI":"10.1063\/1.4948286","article-title":"In-flow detection of ultra-small magnetic particles by an integrated giant magnetic impedance sensor","volume":"108","author":"Fodil","year":"2016","journal-title":"Appl. Phys. Lett."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"7281","DOI":"10.1063\/1.1544449","article-title":"Biodetection using magnetically labeled biomolecules and arrays of spin valve sensors","volume":"93","author":"Ferreira","year":"2003","journal-title":"J. Appl. Phys."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/S0956-5663(02)00205-1","article-title":"High sensitivity detection of molecular recognition using magnetically labelled biomolecules and magnetoresistive sensors","volume":"18","author":"Graham","year":"2003","journal-title":"Biosens. Bioelectron."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2690","DOI":"10.1016\/j.bios.2009.01.040","article-title":"Femtomolar limit of detection with a magnetoresistive biochip","volume":"24","author":"Martins","year":"2009","journal-title":"Biosens. Bioelectron."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.bios.2012.02.048","article-title":"Quantitative biomolecular sensing station based on magnetoresistive patterned arrays","volume":"35","author":"Serrate","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"2211","DOI":"10.1063\/1.1507832","article-title":"Detection of a micron-sized magnetic sphere using a ring-shaped anisotropic magnetoresistance-based sensor: A model for a magnetoresistance-based biosensor","volume":"81","author":"Miller","year":"2002","journal-title":"Appl. Phys. Lett."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"08S105","DOI":"10.1063\/1.2176238","article-title":"An integrated microfluidic cell for detection, manipulation, and sorting of single micron-sized magnetic beads","volume":"99","author":"Jiang","year":"2006","journal-title":"J. Appl. Phys."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.bios.2013.09.026","article-title":"Magnetoresistive sensor for real-time single nucleotide polymorphism genotyping","volume":"52","author":"Rizzi","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/S0304-8853(01)01180-5","article-title":"Giant magnetoimpedance: Concepts and recent progress","volume":"242\u2013245","author":"Knobel","year":"2002","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.pmatsci.2007.05.003","article-title":"Giant magnetoimpedance materials: Fundamentals and applications","volume":"53","author":"Phan","year":"2008","journal-title":"Prog. Mater. Sci."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/j.bios.2016.10.031","article-title":"Magnetic impedance biosensor: A review","volume":"90","author":"Wang","year":"2017","journal-title":"Biosens. Bioelectron."},{"key":"ref_50","first-page":"693","article-title":"Giant magneto-impedance in soft magnetic \u201cWires\u201d","volume":"226\u2013230","year":"2001","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"6280","DOI":"10.1063\/1.1418423","article-title":"Very large magnetoimpedance effect in FeCoNi ferromagnetic tubes with high order magnetic anisotropy","volume":"90","author":"Kurlyandskaya","year":"2001","journal-title":"J. Appl. Phys."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"4965","DOI":"10.1109\/20.539303","article-title":"Enhancement of giant magneto-impedance in layered film by insulator separation","volume":"32","author":"Morikawa","year":"1996","journal-title":"IEEE Trans. Magn."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"4594","DOI":"10.1109\/20.539090","article-title":"Magneto-impedance in sandwich film for magnetic sensor heads","volume":"32","author":"Hika","year":"1996","journal-title":"IEEE Trans. Magn."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"4367","DOI":"10.1109\/20.620448","article-title":"Giant magneto-impedance effect in layered thin films","volume":"33","author":"Morikawa","year":"1997","journal-title":"IEEE Trans. Magn."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/S0378-4371(97)00117-9","article-title":"High-frequency giant magneto-impedance in multilayered magnetic films","volume":"241","author":"Antonov","year":"1997","journal-title":"Phys. A"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1186\/1556-276X-7-230","article-title":"Nanostructured giant magneto-impedance multilayers deposited onto flexible substrates for low pressure sensing","volume":"7","author":"Kurlyandskaya","year":"2012","journal-title":"Nanoscale Res. Lett."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"4611","DOI":"10.1109\/20.334165","article-title":"Thin-film magnetic sensor using high frequency magneto-impedance (HFMI) effect","volume":"30","author":"Senda","year":"1994","journal-title":"IEEE Trans. Magn."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/S0304-8853(99)00851-3","article-title":"Giant magneto-impedance effect in amorphous magnetostrictive FeSiB thin films","volume":"213","author":"Yu","year":"2000","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1109\/TMAG.2002.806351","article-title":"Magneto-impedance effect of a layered CoNbZr amorphous film formed on a polyimide substrate","volume":"39","author":"Nishibe","year":"2003","journal-title":"IEEE Trans. Magn."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"e25","DOI":"10.1016\/j.jmmm.2008.02.116","article-title":"Giant magnetoimpedance in FM\/SiO2\/Cu\/SiO2\/FM films at GHz frequencies","volume":"320","author":"Bohn","year":"2008","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/s00339-012-7034-z","article-title":"Preparation of meander thin-film microsensor and investigation the influence of structural parameters on the giant magnetoimpedance effect","volume":"109","author":"Wang","year":"2012","journal-title":"Appl. Phys. A"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/j.bios.2014.03.008","article-title":"An integrated giant magnetoimpedance biosensor for detection of biomarker","volume":"58","author":"Wang","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1016\/j.phpro.2015.12.141","article-title":"Enhancement of sensitivity on miniaturized thin-film magnetoimpedance with ellipsoidal element","volume":"75","author":"Kikuchi","year":"2015","journal-title":"Phys. Procedia"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/S0921-4526(01)00482-3","article-title":"Soft magnetic wires","volume":"299","year":"2001","journal-title":"Phys. B Condens. Matter"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1088\/0022-3727\/29\/4\/001","article-title":"A soft magnetic wire for sensor applications","volume":"29","author":"Vazquez","year":"1996","journal-title":"J. Phys. D"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"6558","DOI":"10.1063\/1.361945","article-title":"A theoretical model for the giant magnetoimpedance in ribbons of amorphous soft-ferromagnetic alloys","volume":"79","author":"Machado","year":"1996","journal-title":"J. Appl. Phys."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"4783","DOI":"10.1063\/1.1408594","article-title":"Magnetoimpedance effect in amorphous and nanocrystalline ribbons","volume":"90","author":"Hernando","year":"2001","journal-title":"J. Appl. Phys."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1134\/S1063785016080034","article-title":"Asymmetric magnetoimpedance in two-phase ferromagnetic film structures","volume":"42","author":"Antonov","year":"2016","journal-title":"Tech. Phys. Lett."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"7221","DOI":"10.1063\/1.1361048","article-title":"Two-dimensional analysis of magnetoimpedance in magnetic\/metallic multilayers","volume":"89","author":"Panina","year":"2001","journal-title":"J. Appl. Phys."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1109\/TMAG.2009.2033020","article-title":"Differences in the magneto-impedance of FeNi\/Cu\/FeNi multilayers with open and closed magnetic path","volume":"46","author":"Fernandez","year":"2010","journal-title":"IEEE Trans. Magn."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"124501","DOI":"10.1063\/1.4978918","article-title":"Giant magnetoimpedance effect in a thin-film multilayer meander-like sensor","volume":"121","author":"Vilela","year":"2017","journal-title":"J. Appl. Phys."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/S0924-4247(99)00089-8","article-title":"Magneto-impedance in multilayer films","volume":"81","author":"Panina","year":"2000","journal-title":"Sens. Actuator A Phys."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"175003","DOI":"10.1088\/0022-3727\/41\/17\/175003","article-title":"Magnetoimpedance effect in structured multilayered amorphous thin films","volume":"41","author":"Bohn","year":"2008","journal-title":"J. Phys. D Appl. Phys."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/S0924-4247(97)80142-2","article-title":"Magnetoresistive sensors","volume":"59","author":"Mapps","year":"1997","journal-title":"Sens. Actuator A Phys."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1063\/1.1754924","article-title":"Critical thickness and perpendicular anisotropy of evaporated permalloy films with stripe domains","volume":"10","author":"Sugita","year":"1967","journal-title":"Appl. Phys. Lett."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1016\/j.jmmm.2008.11.072","article-title":"Magnetic properties of FeSiB thin films displaying stripe domains","volume":"321","author":"Vinai","year":"2009","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1109\/TMAG.2009.2032519","article-title":"Structure and magnetic properties of thin permalloy films near the \u201ctranscritical\u201d state","volume":"46","author":"Svalov","year":"2010","journal-title":"IEEE Trans. Magn."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"043905","DOI":"10.1063\/1.2512867","article-title":"Magnetoimpedance of single and multilayered FeCuNbSiB films in frequencies up to 1.8 GHz","volume":"101","author":"Viegas","year":"2007","journal-title":"J. Appl. Phys."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"09C502","DOI":"10.1063\/1.3355473","article-title":"FeNi-based magnetic layered nanostructures: Magnetic properties and giant magnetoimpedance","volume":"107","author":"Kurlyandskaya","year":"2010","journal-title":"J. Appl. Phys."},{"key":"ref_80","unstructured":"Mahan, J.E. (2000). Physical Vapor Deposition of Thin Films, John Wiley and Sons."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"S74","DOI":"10.1116\/1.1600450","article-title":"Thin film deposition with physical vapor deposition and related technologies","volume":"21","author":"Rossnagel","year":"2003","journal-title":"J. Vac. Sci. Technol. A"},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Abu-Thabit, N.Y., and Makhlouf, A.S.H. (2020). Fundamental of smart coatings and thin films: Synthesis, deposition methods, and industrial applications. Advances in Smart Coatings and Thin Films for Future Industrial and Biomedical Engineering Applications, Elsevier.","DOI":"10.1016\/B978-0-12-849870-5.00001-X"},{"key":"ref_83","first-page":"1","article-title":"Effect of direct-current bias on the perpendicular giant magnetoimpedance of a meander-line multilayer structure","volume":"11","author":"Wang","year":"2020","journal-title":"IEEE Magn. Lett."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"166527","DOI":"10.1016\/j.jmmm.2020.166527","article-title":"Optimizing magnetoimpedance of amorphous microwires by nanocarbon-induced magnetic anisotropy","volume":"502","author":"Estevez","year":"2020","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"096115","DOI":"10.1088\/2053-1591\/ab32b6","article-title":"Magnetoimpedance study of nickel incorporated diamond like carbon thin films","volume":"6","author":"Pandey","year":"2019","journal-title":"Mater. Res. Express."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"3643","DOI":"10.1109\/20.800617","article-title":"Integrated thin film magneto-impedance sensor head using plating process","volume":"35","author":"Takayama","year":"1999","journal-title":"IEEE Trans. Magn."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.jmmm.2016.02.004","article-title":"Flexible thin film magnetoimpedance sensors","volume":"415","author":"Kurlyandskaya","year":"2016","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"6707","DOI":"10.1109\/JSEN.2015.2463254","article-title":"Equivalent magnetic noise of micro-patterned multilayer thin films based GMI microsensor","volume":"15","author":"Svalov","year":"2015","journal-title":"IEEE Sens. J."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.jmmm.2013.12.009","article-title":"Dynamic magnetic behavior in non-magnetostrictive multilayered films grown on glass and flexible substrates","volume":"355","author":"Agra","year":"2014","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/j.jmmm.2014.11.067","article-title":"Flexible magnetoimpedance sensor","volume":"378","author":"Li","year":"2015","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1016\/j.snb.2013.06.052","article-title":"Development of an ingenious method for determination of Dynabeads protein A based on a giant magnetoimpedance sensor","volume":"186","author":"Wang","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1109\/TMAG.2011.2173167","article-title":"Comparison of micro-fabrication routes for magneto-impedance elements: Lift-off and wet-etching","volume":"48","author":"Barrainkua","year":"2012","journal-title":"IEEE Trans. Magn."},{"key":"ref_93","first-page":"18","article-title":"GMI in nanostructured FeNi\/Ti multilayers with different thicknesses of the magnetic layers","volume":"49","author":"Svalov","year":"2012","journal-title":"IEEE Trans. Magn."},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"162410","DOI":"10.1063\/1.4704984","article-title":"FeNi-based magnetoimpedance multilayers: Tailoring of the softness by magnetic spacers","volume":"100","author":"Svalov","year":"2012","journal-title":"Appl. Phys. Lett."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"3328","DOI":"10.1109\/TMAG.2011.2157896","article-title":"Magnetic properties and giant magnetoimpedance of FeNi-based nanostructured multilayers with variable thickness of the central Cu lead","volume":"47","author":"Volchkov","year":"2011","journal-title":"IEEE Trans. Magn."},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1140\/epjb\/e2013-30933-6","article-title":"Tailoring the magnetic anisotropy of thin film permalloy microstrips by combined shape and induced anisotropies","volume":"86","author":"Svalov","year":"2013","journal-title":"Eur. Phys. J. B"},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/S0924-4247(99)00093-X","article-title":"Size effect on magneto-impedance in layered films","volume":"81","author":"Makhnovskiy","year":"2000","journal-title":"Sens. Actuator A Phys."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.sna.2004.04.043","article-title":"Analysis of magnetoimpedance measurements at high frequency using a microstrip transmission line","volume":"115","year":"2004","journal-title":"Sens. Actuator A Phys."},{"key":"ref_99","first-page":"1","article-title":"High-frequency magnetoimpedance response of thin-film microstructures using coplanar waveguides","volume":"51","author":"Lopez","year":"2015","journal-title":"IEEE Trans. Magn."},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.sna.2005.09.060","article-title":"Very large magnetoimpedance (MI) in FeNi\/Au multilayer film systems","volume":"129","author":"Fry","year":"2006","journal-title":"Sens. Actuator A Phys."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"08C507","DOI":"10.1063\/1.2162043","article-title":"Determination of the intrinsic high-frequency magnetoimpedance spectra of multilayer systems","volume":"99","year":"2006","journal-title":"J. Appl. Phys."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"3053","DOI":"10.1063\/1.1571957","article-title":"Giant-magnetoimpedance-based sensitive element as a model for biosensors","volume":"82","author":"Kurlyandskaya","year":"2003","journal-title":"Appl. Phys. Lett."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1134\/S1063784214020248","article-title":"Magnetic impedance of structured film meanders in the presence of magnetic micro-and nanoparticles","volume":"59","author":"Yuvchenko","year":"2014","journal-title":"Tech. Phys."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"581","DOI":"10.4028\/www.scientific.net\/SSP.190.581","article-title":"Magnetic properties and magnetoimpedance of electroplated wires","volume":"190","author":"Kurlyandskaya","year":"2014","journal-title":"Solid State Phenom."},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.jmmm.2015.11.029","article-title":"Giant magnetoimpedance effect of Co68. 15 Fe4. 35 Si12. 5 B15 amorphous wire in the presence of magnetite ferrofluid","volume":"415","author":"Amirabadizadeh","year":"2016","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.jmmm.2008.11.019","article-title":"Giant magnetoimpedance for biosensing: Advantages and shortcomings","volume":"321","author":"Kurlyandskaya","year":"2009","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"1611","DOI":"10.1016\/j.bios.2004.04.027","article-title":"Magnetic Dynabeads\u00ae detection by sensitive element based on giant magnetoimpedance","volume":"20","author":"Kurlyandskaya","year":"2005","journal-title":"Biosens. Bioelectron."},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"6883","DOI":"10.1039\/C5AY01498K","article-title":"A GMI biochip platform based on Co-based amorphous ribbon for the detection of magnetic Dynabeads","volume":"7","author":"Yang","year":"2015","journal-title":"Anal. Methods"},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"4060","DOI":"10.1109\/TMAG.2012.2235414","article-title":"Magneto-Impedance Biosensor With Enhanced Sensitivity for Highly Sensitive Detection of Nanomag-D Beads","volume":"49","author":"Devkota","year":"2013","journal-title":"IEEE Trans. Magn."},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"193702","DOI":"10.1063\/1.4921224","article-title":"Giant magnetoimpedance biosensor for ferrogel detection: Model system to evaluate properties of natural tissue","volume":"106","author":"Kurlyandskaya","year":"2015","journal-title":"Appl. Phys. Lett."},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"104701","DOI":"10.1063\/1.4795134","article-title":"Detection of low-concentration superparamagnetic nanoparticles using an integrated radio frequency magnetic biosensor","volume":"113","author":"Devkota","year":"2013","journal-title":"J. Appl. Phys."},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1007\/s00604-013-1016-5","article-title":"Ultrasensitive detection of Dynabeads protein A using the giant magnetoimpedance effect","volume":"180","author":"Wang","year":"2013","journal-title":"Mikrochim. Acta"},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1002\/pssa.201330309","article-title":"A giant magnetoimpedance sensor for sensitive detection of streptavidin-coupled Dynabeads","volume":"211","author":"Wang","year":"2014","journal-title":"Phys. Status Solidi(a)"},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"17A323","DOI":"10.1063\/1.4865319","article-title":"Magnetoimpedance of thin film meander with composite coating layer containing Ni nanoparticles","volume":"115","author":"Lodewijk","year":"2014","journal-title":"J. Appl. Phys."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1016\/j.jmmm.2005.02.043","article-title":"Magnetic GMI sensor for detection of biomolecules","volume":"293","author":"Chiriac","year":"2005","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_116","doi-asserted-by":"crossref","unstructured":"Martins, V., Cardoso, F., Loureiro, J., Mercier, M., Germano, J., Cardoso, S., Ferreira, R., Fonseca, L., Sousa, L., and Piedade, M. (2007, January 22\u201327). Integrated spintronic platforms for biomolecular recognition detection. Proceedings of the AIP Conference Proceedings, Sant Feliu de Guixols, Spain.","DOI":"10.1063\/1.2956811"},{"key":"ref_117","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/j.msec.2006.05.041","article-title":"Advanced materials for drug delivery and biosensors based on magnetic label detection","volume":"27","author":"Kurlyandskaya","year":"2007","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"223901","DOI":"10.1063\/1.4882095","article-title":"Quantitative determination of magnetic beads using a magnetoimpedance-based lab-on-a-chip platform","volume":"115","author":"Wang","year":"2014","journal-title":"J. Appl. Phys."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/18\/5213\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:09:30Z","timestamp":1760177370000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/18\/5213"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,12]]},"references-count":118,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2020,9]]}},"alternative-id":["s20185213"],"URL":"https:\/\/doi.org\/10.3390\/s20185213","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,12]]}}}