{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T21:58:14Z","timestamp":1790805494924,"version":"4.1.0"},"reference-count":69,"publisher":"MDPI AG","issue":"24","license":[{"start":{"date-parts":[[2020,12,17]],"date-time":"2020-12-17T00:00:00Z","timestamp":1608163200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Background: Objective assessment of shoulder joint active range of motion (AROM) is critical to monitor patient progress after conservative or surgical intervention. Advancements in miniature devices have led researchers to validate inertial sensors to capture human movement. This study investigated the construct validity as well as intra- and inter-rater reliability of active shoulder mobility measurements using a coupled system of inertial sensors and the Microsoft Kinect (HumanTrak). Methods: 50 healthy participants with no history of shoulder pathology were tested bilaterally for fixed and free ROM: (1) shoulder flexion, and (2) abduction using HumanTrak and goniometry. The repeat testing of the standardised protocol was completed after seven days by two physiotherapists. Results: All HumanTrak shoulder movements demonstrated adequate reliability (intra-class correlation (ICC) \u2265 0.70). HumanTrak demonstrated higher intra-rater reliability (ICCs: 0.93 and 0.85) than goniometry (ICCs: 0.75 and 0.53) for measuring free shoulder flexion and abduction AROM, respectively. Similarly, HumanTrak demonstrated higher intra-rater reliability (ICCs: 0.81 and 0.94) than goniometry (ICCs: 0.70 and 0.93) for fixed flexion and abduction AROM, respectively. Construct validity between HumanTrak and goniometry was adequate except for free abduction. The differences between raters were predominately acceptable and below \u00b110\u00b0. Conclusions: These results indicated that the HumanTrak system is an objective, valid and reliable way to assess and track shoulder ROM.<\/jats:p>","DOI":"10.3390\/s20247238","type":"journal-article","created":{"date-parts":[[2020,12,17]],"date-time":"2020-12-17T10:42:47Z","timestamp":1608201767000},"page":"7238","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["The Reliability and Validity of Wearable Inertial Sensors Coupled with the Microsoft Kinect to Measure Shoulder Range-of-Motion"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5600-7178","authenticated-orcid":false,"given":"Peter","family":"Beshara","sequence":"first","affiliation":[{"name":"Department of Physiotherapy, Prince of Wales Hospital, Sydney, NSW 2031, Australia"},{"name":"Faculty of Medicine, Prince of Wales Clinical School, University of New South Wales, Sydney, NSW 2031, Australia"},{"name":"Surgical &amp; Orthopaedic Research Laboratories, Prince of Wales Hospital, Sydney, NSW 2301, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Judy F.","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Physiotherapy, Prince of Wales Hospital, Sydney, NSW 2031, Australia"},{"name":"Faculty of Medicine, Prince of Wales Clinical School, University of New South Wales, Sydney, NSW 2031, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew C.","family":"Read","sequence":"additional","affiliation":[{"name":"Department of Physiotherapy, Prince of Wales Hospital, Sydney, NSW 2031, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Lagadec","sequence":"additional","affiliation":[{"name":"Vald Performance, Brisbane, QLD 4006, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tian","family":"Wang","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Prince of Wales Clinical School, University of New South Wales, Sydney, NSW 2031, Australia"},{"name":"Surgical &amp; Orthopaedic Research Laboratories, Prince of Wales Hospital, Sydney, NSW 2301, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5023-6148","authenticated-orcid":false,"given":"William Robert","family":"Walsh","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Prince of Wales Clinical School, University of New South Wales, Sydney, NSW 2031, Australia"},{"name":"Surgical &amp; Orthopaedic Research Laboratories, Prince of Wales Hospital, Sydney, NSW 2301, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,12,17]]},"reference":[{"key":"ref_1","first-page":"98","article-title":"Evaluating change in clinical status: Reliability and measures of agreement for the assessment of glenohumeral range of motion","volume":"5","author":"Muir","year":"2010","journal-title":"N. Am. J. Sports Phys. Ther. NAJSPT"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1016\/j.apmr.2004.12.031","article-title":"Interobserver Reproducibility of the Visual Estimation of Range of Motion of the Shoulder","volume":"86","author":"Terwee","year":"2005","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1867","DOI":"10.1093\/ptj\/67.12.1867","article-title":"Clinical measurement of range of motion: Review of goniometry emphasizing reliability and validity","volume":"67","author":"Gajdosik","year":"1987","journal-title":"Phys. Ther."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/j.math.2014.05.009","article-title":"Reliability and concurrent validity of knee angle measurement: Smart phone app versus universal goniometer used by experienced and novice clinicians","volume":"19","author":"Milanese","year":"2014","journal-title":"Man. Ther."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1002\/pri.97","article-title":"Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects","volume":"2","author":"Brosseau","year":"1997","journal-title":"Physiother. Res. Int."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"704","DOI":"10.12965\/jer.1735110.555","article-title":"Inter- and intrarater reliability of goniometry and hand held dynamometry for patients with subacromial impingement syndrome","volume":"13","author":"Fieseler","year":"2017","journal-title":"J. Exerc. Rehabil."},{"key":"ref_7","first-page":"e555725","article-title":"Reliability and Validity of a Smartphone-Based Inclinometer Application Measuring Shoulder Internal Rotation","volume":"7","author":"Lau","year":"2020","journal-title":"J. Phys. Fit. Med. Treat. Sports"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/S0004-9514(14)60274-9","article-title":"Reliability of five methods for assessing shoulder range of motion","volume":"47","author":"Hayes","year":"2001","journal-title":"Aust. J. Physiother."},{"key":"ref_9","first-page":"306","article-title":"The reliability and concurrent validity of shoulder mobility measurements using a digital inclinometer and goniometer: A technical report","volume":"7","author":"Kolber","year":"2012","journal-title":"Int. J. Sports Phys. Ther."},{"key":"ref_10","first-page":"288","article-title":"Upper extremity joint movement: Comparison of two measurement devices","volume":"70","author":"Greene","year":"1989","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/S0003-9993(98)90038-7","article-title":"Goniometric assessment of shoulder range of motion: Comparison of testing in supine and sitting positions","volume":"79","author":"Sabari","year":"1998","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"784","DOI":"10.2106\/00004623-199505000-00017","article-title":"Range-of-motion measurements","volume":"77","author":"Lea","year":"1995","journal-title":"J. Bone Joint Surg. Am."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2644","DOI":"10.1589\/jpts.28.2644","article-title":"The effect of proficiency level on measurement error of range of motion","volume":"28","author":"Akizuki","year":"2016","journal-title":"J. Phys. Ther. Sci."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1109\/TSMCA.2012.2189876","article-title":"Adaptive Information Fusion for Human Upper Limb Movement Estimation","volume":"42","author":"Zhang","year":"2012","journal-title":"IEEE Trans. Syst. Man Cybern. Part A Syst. Hum."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Teufl, W., Miezal, M., Taetz, B., Fr\u00f6hlich, M., and Bleser, G. (2019). Validity of inertial sensor based 3D joint kinematics of static and dynamic sport and physiotherapy specific movements. PLoS ONE, 14.","DOI":"10.1371\/journal.pone.0213064"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1123\/jab.2016-0120","article-title":"Validation of Inertial Measurement Units for Upper Body Kinematics","volume":"33","author":"Morrow","year":"2017","journal-title":"J. Appl. Biomech."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1080\/00140139.2015.1079335","article-title":"Accuracy and repeatability of an inertial. measurement unit system for field-based occupational studies","volume":"59","author":"Schall","year":"2016","journal-title":"Ergonomics"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.medengphy.2006.11.010","article-title":"Use of multiple wearable inertial sensors in upper limb motion tracking","volume":"30","author":"Zhou","year":"2008","journal-title":"Med. Eng. Phys."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s11517-007-0296-5","article-title":"Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors","volume":"46","author":"Cutti","year":"2008","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2635","DOI":"10.1109\/TBME.2012.2208750","article-title":"Shoulder and Elbow Joint Angle Tracking With Inertial Sensors","volume":"59","author":"McNames","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1682\/JRRD.2014.06.0146","article-title":"Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor","volume":"52","author":"Picerno","year":"2015","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Rigoni, M., Gill, S., Babazadeh, S., Elsewaisy, O., Gillies, H., Nguyen, N., Pathirana, P.N., and Page, R. (2019). Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device-A Validation Study. Sensors, 19.","DOI":"10.3390\/s19081781"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/j.apergo.2017.04.004","article-title":"Using the Microsoft Kinect\u2122 to assess 3-D shoulder kinematics during computer use","volume":"65","author":"Xu","year":"2017","journal-title":"Appl. Ergon."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Orand, A., Aksoy, E.E., Miyasaka, H., Levy, C.W., Zhang, X., and Menon, C. (2019). Bilateral Tactile Feedback-Enabled Training for Stroke Survivors Using Microsoft KinectTM. Sensors, 19.","DOI":"10.3390\/s19163474"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Ma, Y., Mithraratne, K., Wilson, N.C., Wang, X., Ma, Y., and Zhang, Y. (2019). The Validity and Reliability of a Kinect v2-Based Gait Analysis System for Children with Cerebral Palsy. Sensors, 19.","DOI":"10.3390\/s19071660"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Fern\u2019Ndez-Baena, A., Susin, A., and Lligadas, X. (2012, January 19\u201321). Biomechanical Validation of Upper-Body and Lower-Body Joint Movements of Kinect Motion Capture Data for Rehabilitation Treatments. Proceedings of the 2012 Fourth International Conference on Intelligent Networking and Collaborative Systems, Bucharest, Romania.","DOI":"10.1109\/iNCoS.2012.66"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.physio.2015.02.002","article-title":"Validity and reliability of Kinect skeleton for measuring shoulder joint angles: A feasibility study","volume":"101","author":"Huber","year":"2015","journal-title":"Physiotherapy"},{"key":"ref_28","first-page":"6710595","article-title":"Statistical Validation for Clinical Measures: Repeatability and Agreement of Kinect\u2122-Based Software","volume":"2018","author":"Perez","year":"2018","journal-title":"BioMed Res. Int."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"289","DOI":"10.3233\/THC-140831","article-title":"Range of motion assessment of the shoulder and elbow joints using a motion sensing input device: A pilot study","volume":"22","author":"Hawi","year":"2014","journal-title":"Technol. Health Care"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.gaitpost.2013.09.018","article-title":"Validity and reliability of the Kinect within functional assessment activities: Comparison with standard stereophotogrammetry","volume":"39","author":"Jansen","year":"2014","journal-title":"Gait Posture"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2014\/846514","article-title":"A Review on Technical and Clinical Impact of Microsoft Kinect on Physical Therapy and Rehabilitation","volume":"2014","author":"Hondori","year":"2014","journal-title":"J. Med. Eng."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1515\/ijdhd-2014-0329","article-title":"Development and validation of tele-health system for stroke rehabilitation","volume":"13","author":"Kizony","year":"2014","journal-title":"Int. J. Disabil. Hum. Dev."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"e382","DOI":"10.1016\/j.jse.2017.06.004","article-title":"Can shoulder range of movement be measured accurately using the Microsoft Kinect sensor plus Medical Interactive Recovery Assistant (MIRA) software?","volume":"26","author":"Wilson","year":"2017","journal-title":"J. Shoulder Elb. Surg."},{"key":"ref_34","first-page":"20","article-title":"Reliability and validity analyzes of Kinect V2 based measurement system for shoulder motions","volume":"76","author":"Zileli","year":"2019","journal-title":"Med. Eng. Phys."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1515\/bmt-2015-0206","article-title":"Feasibility study of using a Microsoft Kinect for virtual coaching of wheelchair transfer techniques","volume":"62","author":"Hwang","year":"2017","journal-title":"Biomed. Eng."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"17292","DOI":"10.1109\/ACCESS.2018.2811720","article-title":"Dynamic Evaluation and Treatment of the Movement Amplitude Using Kinect Sensor","volume":"6","author":"Neto","year":"2018","journal-title":"IEEE Access"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Guneysu, A., Siyli, R.D., and Salah, A.A. (2014, January 25\u201329). Auto-evaluation of motion imitation in a child-robot imitation game for upper arm rehabilitation. Proceedings of the the 23rd IEEE International Symposium on Robot and Human Interactive Communication, Edinburgh, UK.","DOI":"10.1109\/ROMAN.2014.6926253"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1682\/JRRD.2015.10.0198","article-title":"Reliability and validity of the Microsoft Kinect for assessment of manual wheelchair propulsion","volume":"53","author":"Milgrom","year":"2016","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/BF02345966","article-title":"Measuring orientation of human body segments using miniature gyroscopes and accelerometers","volume":"43","author":"Luinge","year":"2005","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"967245","DOI":"10.1155\/2010\/967245","article-title":"Complete Triaxis Magnetometer Calibration in the Magnetic Domain","volume":"2010","author":"Renaudin","year":"2010","journal-title":"J. Sens."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.gaitpost.2012.03.033","article-title":"Validity of the Microsoft Kinect for assessment of postural control","volume":"36","author":"Clark","year":"2012","journal-title":"Gait Posture"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"091005","DOI":"10.1115\/1.4034170","article-title":"Human Arm Motion Tracking by Orientation-Based Fusion of Inertial Sensors and Kinect Using Unscented Kalman Filter","volume":"138","author":"Atrsaei","year":"2016","journal-title":"J. Biomech. Eng."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Bo, A.P.L., Hayashibe, M., and Poignet, P. (September, January 30). Joint angle estimation in rehabilitation with inertial sensors and its integration with Kinect. Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA.","DOI":"10.1109\/IEMBS.2011.6090940"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1016\/j.procs.2018.07.121","article-title":"Kinect Camera Based Gait Data Recording and Analysis for Assistive Robotics-An Alternative to Goniometer Based Measurement Technique","volume":"133","author":"Roy","year":"2018","journal-title":"Procedia Comput. Sci."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"7175240","DOI":"10.1155\/2019\/7175240","article-title":"Validity and Reliability of Upper Limb Functional Assessment Using the Microsoft Kinect V2 Sensor","volume":"2019","author":"Cai","year":"2019","journal-title":"Appl. Bionics Biomech."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Mangal, N.K., and Tiwari, A.K. (2020, January 20\u201324). Kinect v2 tracked Body Joint Smoothing for Kinematic Analysis in Musculoskeletal Disorders. Proceedings of the 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Montreal, QC, Canada.","DOI":"10.1109\/EMBC44109.2020.9175492"},{"key":"ref_47","unstructured":"HumanTrak Validation Case Study (2018, December 10). Australian Catholic University Biomechanics Laboratory. Available online: https:\/\/www.valdperformance.com\/wp-content\/uploads\/2018\/12\/HumanTrak-Validation-Case-Study-ACU-Melbourne-2.0.pdf."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"145","DOI":"10.18857\/jkpt.2017.29.3.145","article-title":"Validity and Reliability of an Inertial Measurement Unit-Based 3D Angular Measurement of Shoulder Joint Motion","volume":"29","author":"Yoon","year":"2017","journal-title":"J. Korean Phys. Ther."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Lee, S.H., Yoon, C., Chung, S.G., Kim, H.C., Kwak, Y., Park, H.-W., and Kim, K. (2015). Measurement of Shoulder Range of Motion in Patients with Adhesive Capsulitis Using a Kinect. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0129398"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12995-015-0058-5","article-title":"A technical support tool for joint range of motion determination in functional diagnostics\u2014An inter-rater study","volume":"10","author":"Schiefer","year":"2015","journal-title":"J. Occup. Med. Toxicol."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L.J., and Roy, J.S. (2019). Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review. Sensors, 19.","DOI":"10.3390\/s19071555"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/j.pmr.2018.12.006","article-title":"Validity and Reliability of the Kinect for Assessment of Standardized Transitional Movements and Balance: Systematic Review and Translation into Practice","volume":"30","author":"Puh","year":"2019","journal-title":"Phys. Med. Rehabil. Clin. N. Am."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1186\/s40798-018-0167-7","article-title":"Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review","volume":"4","author":"Walmsley","year":"2018","journal-title":"Sports Med Open."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1454","DOI":"10.1016\/j.jse.2014.01.006","article-title":"Measuring shoulder external and internal rotation strength and range of motion: Comprehensive intra-rater and inter-rater reliability study of several testing protocols","volume":"23","author":"Cools","year":"2014","journal-title":"J. Shoulder Elb. Surg."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"327","DOI":"10.3109\/09593980903094230","article-title":"Reliability of shoulder range of motion comparing a goniometer to a digital level","volume":"26","author":"Mullaney","year":"2010","journal-title":"Physiother. Theory Pract."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1093\/ptj\/67.5.668","article-title":"Goniometric reliability in a clinical setting. Shoulder measurements","volume":"67","author":"Riddle","year":"1987","journal-title":"Phys. Ther."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1179\/1743288X11Y.0000000023","article-title":"The reliability of clinical measurements designed to quantify shoulder mobility","volume":"16","author":"Hanney","year":"2011","journal-title":"Phys. Ther. Rev."},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Beshara, P., Chen, J., Lagadec, P., and Walsh, W.R. (2016). Test-Retest and Intra-rater Reliability of Using Inertial Sensors and Its Integration with Microsoft Kinect\u2122 to Measure Shoulder Range-of-Motion. Internet of Things Technologies for HealthCare, Springer International Publishing. Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering Series.","DOI":"10.1007\/978-3-319-51234-1_31"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.pmrj.2012.08.019","article-title":"Clinical Examination of the Rotator Cuff","volume":"5","author":"Jain","year":"2013","journal-title":"PM R."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","article-title":"Intraclass correlations: Uses in assessing rater reliability","volume":"86","author":"Shrout","year":"1979","journal-title":"Psychol. Bull."},{"key":"ref_62","first-page":"231","article-title":"Quantifying Test-Retest Reliability Using the Intraclass Correlation Coefficient and the SEM","volume":"19","author":"Weir","year":"2005","journal-title":"J. Strength Cond. Res."},{"key":"ref_63","unstructured":"Portney, L.G., and Watkins, M.P. (2009). Foundations of Clinical Research: Applications to Practice, Pearson Prentice Hall. [3rd ed.]."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"327","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"ref_65","doi-asserted-by":"crossref","unstructured":"De Winter, A.F., Heemskerk, M., Terwee, C., Jans, M.P., Devill\u00e9, W., Van Schaardenburg, D.-J., Scholten, R.J.P.M., and Bouter, L.M. (2004). Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer. BMC Musculoskelet. Disord., 5.","DOI":"10.1186\/1471-2474-5-18"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.jclinepi.2006.03.012","article-title":"Quality criteria were proposed for measurement properties of health status questionnaires","volume":"60","author":"Terwee","year":"2007","journal-title":"J. Clin. Epidemiol."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"1378","DOI":"10.1016\/j.spinee.2019.04.004","article-title":"Measurement properties of walking outcome measures for neurogenic claudication: A systematic review and meta analysis","volume":"19","author":"Anderson","year":"2019","journal-title":"Spine J."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1093\/rheumatology\/39.4.382","article-title":"The reliability of the three-dimensional FASTRAK measurement system in measuring cervical spine and shoulder range of motion in healthy subjects","volume":"39","author":"Jordan","year":"2000","journal-title":"Rheumatology"},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Springer, S., and Seligmann, G.Y. (2016). Validity of the Kinect for Gait Assessment: A Focused Review. Sensors, 16.","DOI":"10.3390\/s16020194"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/24\/7238\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:46:28Z","timestamp":1760179588000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/24\/7238"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,17]]},"references-count":69,"journal-issue":{"issue":"24","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["s20247238"],"URL":"https:\/\/doi.org\/10.3390\/s20247238","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12,17]]}}}