{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T07:54:29Z","timestamp":1789977269480,"version":"4.0.1"},"reference-count":26,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2020,12,25]],"date-time":"2020-12-25T00:00:00Z","timestamp":1608854400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003032","name":"Association Nationale de la Recherche et de la Technologie","doi-asserted-by":"publisher","award":["N\u00b0 2016\/1600"],"award-info":[{"award-number":["N\u00b0 2016\/1600"]}],"id":[{"id":"10.13039\/501100003032","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Patients with central respiratory paralysis can benefit from diaphragm pacing to restore respiratory function. However, it would be important to develop a continuous respiratory monitoring method to alert on apnea occurrence, in order to improve the efficiency and safety of the pacing system. In this study, we present a preliminary validation of an acoustic apnea detection method on healthy subjects data. Thirteen healthy participants performed one session of two 2-min recordings, including a voluntary respiratory pause. The recordings were post-processed by combining temporal and frequency detection domains, and a new method was proposed\u2014Phonocardiogram-Derived Respiration (PDR). The detection results were compared to synchronized pneumotachograph, electrocardiogram (ECG), and abdominal strap (plethysmograph) signals. The proposed method reached an apnea detection rate of 92.3%, with 99.36% specificity, 85.27% sensitivity, and 91.49% accuracy. PDR method showed a good correlation of 0.77 with ECG-Derived Respiration (EDR). The comparison of R-R intervals and S-S intervals also indicated a good correlation of 0.89. The performance of this respiratory detection algorithm meets the minimal requirements to make it usable in a real situation. Noises from the participant by speaking or from the environment had little influence on the detection result, as well as body position. The high correlation between PDR and EDR indicates the feasibility of monitoring respiration with PDR.<\/jats:p>","DOI":"10.3390\/s21010099","type":"journal-article","created":{"date-parts":[[2020,12,27]],"date-time":"2020-12-27T20:52:21Z","timestamp":1609102341000},"page":"99","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Respiratory Monitoring Based on Tracheal Sounds: Continuous Time-Frequency Processing of the Phonospirogram Combined with Phonocardiogram-Derived Respiration"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0896-2621","authenticated-orcid":false,"given":"Xinyue","family":"Lu","sequence":"first","affiliation":[{"name":"Facult\u00e9 des Sciences, University of Montpellier, F-34090 Montpellier, France"},{"name":"NeuroResp, F-34600 Les Aires, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7379-8004","authenticated-orcid":false,"given":"Christine","family":"Azevedo Coste","sequence":"additional","affiliation":[{"name":"INRIA, F-34090 Montpellier, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9370-7301","authenticated-orcid":false,"given":"Marie-C\u00e9cile","family":"Nierat","sequence":"additional","affiliation":[{"name":"UMRS1158 Neurophysiologie Respiratoire Exp\u00e9rimentale et Clinique, INSERM, Sorbonne Universit\u00e9, F-75005 Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Serge","family":"Renaux","sequence":"additional","affiliation":[{"name":"NeuroResp, F-34600 Les Aires, France"},{"name":"NEURINNOV, F-34090 Montpellier, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2868-9279","authenticated-orcid":false,"given":"Thomas","family":"Similowski","sequence":"additional","affiliation":[{"name":"UMRS1158 Neurophysiologie Respiratoire Exp\u00e9rimentale et Clinique, INSERM, Sorbonne Universit\u00e9, F-75005 Paris, France"},{"name":"AP-HP, Site Piti\u00e9-Salp\u00eatri\u00e8re, Service de Pneumologie, M\u00e9decine Intensive et R\u00e9animation (D\u00e9partement R3S), Groupe Hospitalier Universitaire APHP-Sorbonne Universit\u00e9, F-75013 Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4184-6243","authenticated-orcid":false,"given":"David","family":"Guiraud","sequence":"additional","affiliation":[{"name":"INRIA, F-34090 Montpellier, France"},{"name":"NEURINNOV, F-34090 Montpellier, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,12,25]]},"reference":[{"key":"ref_1","first-page":"457","article-title":"Stimulation phr\u00e9nique implant\u00e9e","volume":"7","author":"Similowski","year":"2001","journal-title":"M\u00e9d. Th\u00e9r."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1311","DOI":"10.1111\/j.1540-8159.1996.tb04209.x","article-title":"Diaphragm pacing with a quadripolar phrenic nerve electrode: An international study","volume":"19","author":"Silvestri","year":"1996","journal-title":"PACE Pacing Clin. Electrophysiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1097\/00000658-197010000-00020","article-title":"Central hypoventilation; long-term ventilatory assistance by radiofrequency electrophrenic respiration","volume":"172","author":"Glenn","year":"1970","journal-title":"Ann. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.jtcvs.2011.04.033","article-title":"Intrathoracic phrenic pacing: A 10-year experience in France","volume":"142","author":"Hubsch","year":"2011","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_5","unstructured":"Iber, C., Ancoli-Israel, S., Chesson, A.L., and Quan, S.F. (2007). The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications, American Academy of Sleep Medicine Westchester."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1016\/j.ccm.2018.01.008","article-title":"Diaphragm Pacing","volume":"39","author":"DiMarco","year":"2018","journal-title":"Clin. Chest Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.1152\/japplphysiol.00028.2002","article-title":"Phonospirometry for noninvasive measurement of ventilation: Methodology and preliminary results","volume":"93","author":"Que","year":"2002","journal-title":"J. Appl. Physiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1109\/TBME.2007.910679","article-title":"Breathing detection: Towards a miniaturized, wearable, battery-operated monitoring system","volume":"55","author":"Corbishley","year":"2008","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1007\/s11517-010-0674-2","article-title":"Sleep apnea monitoring and diagnosis based on pulse oximetery and tracheal sound signals","volume":"48","author":"Yadollahi","year":"2010","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1007\/s11517-017-1706-y","article-title":"Apnea and heart rate detection from tracheal body sounds for the diagnosis of sleep-related breathing disorders","volume":"56","author":"Kalkbrenner","year":"2017","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_11","unstructured":"Chuah, J.S., and Moussavi, Z. (2001, January 1). Automated detection of respiratory phases by acoustical means. Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286), Hong Kong, China."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"323","DOI":"10.3233\/THC-2004-12404","article-title":"An improved bioacoustic method for monitoring of respiration","volume":"12","author":"Hult","year":"2004","journal-title":"Technol. Health Care"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1049\/cp:20000312","article-title":"A method for respiration monitoring by the use of a bioacoustic signal","volume":"Volume 2000","author":"Hult","year":"2000","journal-title":"Proceedings of the First International Conference on Advances in Medical Signal and Information Processing"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Kalkbrenner, C., Stark, P., Kouemou, G., Algorri, M.E., and Brucher, R. (2014, January 26\u201330). Sleep monitoring using body sounds and motion tracking. Proceedings of the 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, USA.","DOI":"10.1109\/EMBC.2014.6945224"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1007\/s11517-009-0446-z","article-title":"New tracheal sound feature for apnoea analysis","volume":"47","author":"Kulkas","year":"2009","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.neucom.2014.04.002","article-title":"Content-based classification of breath sound with enhanced features","volume":"141","author":"Lei","year":"2014","journal-title":"Neurocomputing"},{"key":"ref_17","first-page":"501","article-title":"Computerized acoustical techniques for respiratory flow-sound analysis: A systematic review","volume":"53","author":"Muthusamy","year":"2019","journal-title":"Artif. Intell. Rev."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1088\/1361-6579\/aa5feb","article-title":"ECG derived respiration: Comparison of time-domain approaches and application to altered breathing patterns of patients with schizophrenia","volume":"38","author":"Schmidt","year":"2017","journal-title":"Physiol. Meas."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1109\/TBME.2017.2720463","article-title":"In-Ear Audio Wearable: Measurement of Heart and Breathing Rates for Health and Safety Monitoring","volume":"65","author":"Martin","year":"2018","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_20","unstructured":"White Noise Soundscapes (2020, December 25). City Traffic White Noise |10 Hours| For Sleeping, Studying or to Block Out Noise. Available online: https:\/\/www.youtube.com\/watch?v=8s5H76F3SIs."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Lu, X., Guiraud, D., Renaux, S., Similowski, T., and Azevedo, C. (2019, January 23\u201327). Breathing detection from tracheal sounds in both temporal and frequency domains in the context of phrenic nerve stimulation. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany.","DOI":"10.1109\/EMBC.2019.8856440"},{"key":"ref_22","unstructured":"Lu, X., Guiraud, D., Renaux, S., Similowski, T., Azevedo Coste, C., and Azevedo, C. (2019, January 24\u201328). Monitoring phrenic nerve stimulation-induced breathing via tracheal sounds. Proceedings of the 2019 XXIII Annual Conference of the International Functional Electrical Stimulation Society (IFESS), Toronto, ON, Canada."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"e37","DOI":"10.1183\/20734735.008817","article-title":"The use of tracheal sounds for the diagnosis of sleep apnoea","volume":"13","author":"Penzel","year":"2017","journal-title":"Breathe"},{"key":"ref_24","unstructured":"Liang, H., Lukkarinen, S., and Hartimo, I. (1997, January 7\u201310). Heart sound segmentation algorithm based on heart sound envelogram. Proceedings of the Computers in Cardiology, Lund, Sweden."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2098","DOI":"10.1109\/TASL.2006.872621","article-title":"Improved signal-to-noise ratio estimation for speech enhancement","volume":"14","author":"Plapous","year":"2006","journal-title":"IEEE Trans. Audio Speech Lang. Process."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Ozkan, I., Member, S., Yilmaz, A., and Celebi, G. (2019, January 23\u201327). Improved Segmentation with Dynamic Threshold Adjustment for Phonocardiography Recordings. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany.","DOI":"10.1109\/EMBC.2019.8856714"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/1\/99\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:46:20Z","timestamp":1760179580000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/1\/99"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,25]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,1]]}},"alternative-id":["s21010099"],"URL":"https:\/\/doi.org\/10.3390\/s21010099","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12,25]]}}}