{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T01:57:42Z","timestamp":1791338262360,"version":"4.3.1"},"reference-count":60,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2020,12,26]],"date-time":"2020-12-26T00:00:00Z","timestamp":1608940800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["OIA-1655221"],"award-info":[{"award-number":["OIA-1655221"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this paper, we report a simple and inexpensive paper-based microfluidic device for detecting nitrate in water. This device incorporates two recent developments in paper-based technology suitable for nitrate detection and has an optimized microfluidic design. The first technical advancement employed is an innovative fibrous composite material made up of cotton fibers and zinc microparticles that can be incorporated in paper-based devices and results in better nitrate reduction. The second is a detection zone with an immobilized reagent that allows the passage of a larger sample volume. Different acids were tested\u2014citric and phosphoric acids gave better results than hydrochloric acid since this acid evaporates completely without leaving any residue behind on paper. Different microfluidic designs that utilize various fluid control technologies were investigated and a design with a folding detection zone was chosen and optimized to improve the uniformity of the signal produced. The optimized design allowed the device to achieve a limit of detection and quantification of 0.53 ppm and 1.18 ppm, respectively, for nitrate in water. This accounted for more than a 40% improvement on what has been previously realized for the detection of nitrate in water using paper-based technology.<\/jats:p>","DOI":"10.3390\/s21010102","type":"journal-article","created":{"date-parts":[[2020,12,27]],"date-time":"2020-12-27T20:52:21Z","timestamp":1609102341000},"page":"102","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":48,"title":["A New Paper-Based Microfluidic Device for Improved Detection of Nitrate in Water"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4522-9469","authenticated-orcid":false,"given":"Amer","family":"Charbaji","sequence":"first","affiliation":[{"name":"Microfluidics Laboratory, Department of Mechanical, Industrial and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7236-9558","authenticated-orcid":false,"given":"Hojat","family":"Heidari-Bafroui","sequence":"additional","affiliation":[{"name":"Microfluidics Laboratory, Department of Mechanical, Industrial and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Constantine","family":"Anagnostopoulos","sequence":"additional","affiliation":[{"name":"Microfluidics Laboratory, Department of Mechanical, Industrial and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad","family":"Faghri","sequence":"additional","affiliation":[{"name":"Microfluidics Laboratory, Department of Mechanical, Industrial and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,12,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Pengpumkiat, S., Nammoonnoy, J., Wongsakoonkan, W., Konthonbut, P., and Kongtip, P. (2020). A Microfluidic Paper-Based Analytical Device for Type-II Pyrethroid Targets in an Environmental Water Sample. Sensors, 20.","DOI":"10.3390\/s20154107"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Racicot, J.M., Mako, T.L., Olivelli, A., and Levine, M. (2020). A Paper-Based Device for Ultrasensitive, Colorimetric Phosphate Detection in Seawater. Sensors, 20.","DOI":"10.3390\/s20102766"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Kumar, S., Nehra, M., Mehta, J., Dilbaghi, N., Marrazzabd, G., and Kaushik, A. (2019). Point-of-Care Strategies for Detection of Waterborne Pathogens. Sensors, 19.","DOI":"10.3390\/s19204476"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Guti\u00e9rrez-Capit\u00e1n, M., Baldi, A., and Fern\u00e1ndez-S\u00e1nchez, C. (2020). Electrochemical Paper-Based Biosensor Devices for Rapid Detection of Biomarkers. Sensors, 20.","DOI":"10.3390\/s20040967"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Hristov, D.R., Rodriguez-Quijada, C., G\u00f3mez-M\u00e1rquez, J., and Hamad-Schifferli, K. (2019). Designing Paper-Based Immunoassays for Biomedical Applications. Sensors, 19.","DOI":"10.3390\/s19030554"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"496","DOI":"10.3389\/fchem.2018.00496","article-title":"Developing Paper Based Diagnostic Technique to Detect Uric Acid in Urine","volume":"6","author":"Islam","year":"2018","journal-title":"Front. Chem."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Gao, H., Yan, C., Wu, W., and Li, J. (2020). Application of Microfluidic Chip Technology in Food Safety Sensing. Sensors, 20.","DOI":"10.3390\/s20061792"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Choi, J.R., Yong, K.W., Choi, J.Y., and Cowie, A.C. (2019). Emerging Point-of-care Technologies for Food Safety Analysis. Sensors, 19.","DOI":"10.3390\/s19040817"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Shriver-Lake, L., Zabetakis, D., Dressick, W.J., Stenger, D., and Trammell, S.A. (2018). Paper-Based Electrochemical Detection of Chlorate. Sensors, 18.","DOI":"10.3390\/s18020328"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Singh, A.T., Lantigua, D., Meka, A., Taing, S., Pandher, M., and Camci-Unal, G. (2018). Paper-Based Sensors: Emerging Themes and Applications. Sensors, 18.","DOI":"10.3390\/s18092838"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1039\/B915833B","article-title":"The extraction of liquid, protein molecules and yeast cells from paper through surface acoustic wave atomization","volume":"10","author":"Qi","year":"2010","journal-title":"Lab Chip"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1021\/ac303205m","article-title":"Dried Blood Spots: Analysis and Applications","volume":"85","author":"Demirev","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Soum, V., Park, S., Brilian, A.I., Kwon, O.-S., and Shin, K. (2019). Programmable Paper-Based Microfluidic Devices for Biomarker Detections. Micromachines, 10.","DOI":"10.3390\/mi10080516"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"011301","DOI":"10.1063\/1.3687398","article-title":"A perspective on paper-based microfluidics: Current status and future trends","volume":"6","author":"Li","year":"2012","journal-title":"Biomicrofluidics"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1021\/ac60033a032","article-title":"Automatic Paper Chromatography","volume":"21","author":"Muller","year":"1949","journal-title":"Anal. Chem."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1002\/anie.200603817","article-title":"Patterned Paper as a Platform for Inexpensive, Low-Volume, Portable Bioassays","volume":"46","author":"Martinez","year":"2007","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.aca.2020.07.030","article-title":"Novel approaches for colorimetric measurements in analytical chemistry\u2014A review","volume":"1135","author":"Fernandes","year":"2020","journal-title":"Anal. Chim. Acta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.talanta.2017.08.072","article-title":"Developments of microfluidic paper-based analytical devices (\u03bcPADs) for water analysis: A review","volume":"177","author":"Almeida","year":"2018","journal-title":"Talanta"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"5654","DOI":"10.1021\/acs.analchem.6b03860","article-title":"Beyond Wicking: Expanding the Role of Patterned Paper as the Foundation for an Analytical Platform","volume":"89","author":"Fernandes","year":"2017","journal-title":"Anal. Chem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1021\/ac503968p","article-title":"Recent Developments in Paper-Based Microfluidic Devices","volume":"87","author":"Cate","year":"2015","journal-title":"Anal. Chem."},{"key":"ref_21","unstructured":"World Health Organization (2017). Guidelines for Drinking-Water Quality, WHO. [4th ed.]. Available online: https:\/\/www.who.int\/publications\/i\/item\/9789241549950."},{"key":"ref_22","unstructured":"U.S. Geological Survey (2020, October 22). Nitrogen and Water, Available online: https:\/\/www.usgs.gov\/special-topic\/water-science-school\/science\/nitrogen-and-water?qt-science_center_objects=0#qt-science_center_objects."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"632","DOI":"10.3389\/fchem.2018.00632","article-title":"Catalytic and Photocatalytic Nitrate Reduction Over Pd-Cu Loaded Over Hybrid Materials of Multi-Walled Carbon Nanotubes and TiO2","volume":"6","author":"Silva","year":"2018","journal-title":"Front. Chem."},{"key":"ref_24","first-page":"1","article-title":"Pathophysiology of Nitrate Toxicity in Human and its Mitigation Measures","volume":"20","author":"Gupta","year":"2010","journal-title":"Bull. Reg. Assess. React. Nitrogen"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Ward, M.H., Jones, R.R., Brender, J.D., De Kok, T.M., Weyer, P.J., Nolan, B.T., Villanueva, C.M., and Van Breda, S.G. (2018). Drinking Water Nitrate and Human Health: An Updated Review. Int. J. Environ. Res. Public Health, 15.","DOI":"10.3390\/ijerph15071557"},{"key":"ref_26","unstructured":"Estimated Nitrate Concentrations in Groundwater Used for Drinking (2020, October 07). Nutrient Pollution Policy and Data. US EPA, Available online: https:\/\/www.epa.gov\/nutrient-policy-data\/estimated-nitrate-concentrations-groundwater-used-drinking."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"De Acha, N., Elosua, C., Corres, J.M., and Arregui, F.J. (2019). Fluorescent Sensors for the Detection of Heavy Metal Ions in Aqueous Media. Sensors, 19.","DOI":"10.3390\/s19030599"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.sna.2018.07.026","article-title":"Detection methods of nitrate in water: A review","volume":"280","author":"Alahi","year":"2018","journal-title":"Sens. Actuators A Phys."},{"key":"ref_29","first-page":"97","article-title":"Novel methods of nitrate and nitrite determination\u2014A review","volume":"25","author":"Wierzbicka","year":"2019","journal-title":"J. Elementol."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Kapoor, A., Balasubramanian, S., Muthamilselvi, P., Vaishampayan, V., and Prabhakar, S. (2020). Lab-on-a-Chip Devices for Water Quality Monitoring, Springer.","DOI":"10.1007\/978-3-030-45116-5_15"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Jaywant, S.A., and Arif, K.M. (2019). A Comprehensive Review of Microfluidic Water Quality Monitoring Sensors. Sensors, 19.","DOI":"10.3390\/s19214781"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Khanfar, M.F., Al-Faqheri, W., and Al-Halhouli, A. (2017). Low Cost Lab on Chip for the Colorimetric Detection of Nitrate in Mineral Water Products. Sensors, 17.","DOI":"10.3390\/s17102345"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"7274","DOI":"10.1021\/ac5013249","article-title":"Microfluidic Paper-Based Analytical Device for the Determination of Nitrite and Nitrate","volume":"86","author":"Jayawardane","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Teepoo, S., Arsawiset, S., and Chanayota, P. (2019). One-Step Polylactic Acid Screen-Printing Microfluidic Paper-Based Analytical Device: Application for Simultaneous Detection of Nitrite and Nitrate in Food Samples. Chemosensors, 7.","DOI":"10.3390\/chemosensors7030044"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1134\/S1061934820040127","article-title":"Paper-based Analytical Device (PAD) for the Determination of Borax, Salicylic Acid, Nitrite, and Nitrate by Colorimetric Methods","volume":"75","author":"Ratnarathorn","year":"2020","journal-title":"J. Anal. Chem."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"105412","DOI":"10.1016\/j.microc.2020.105412","article-title":"An Environmentally Friendly Microfluidic Paper-Based Analytical Device for Simultaneous Colorimetric Detection of Nitrite and Nitrate in Food Products","volume":"159","author":"Thongkam","year":"2020","journal-title":"Microchem. J."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"121183","DOI":"10.1016\/j.talanta.2020.121183","article-title":"Novel microfluidic paper-based analytical devices (\u03bcPADs) for the determination of nitrate and nitrite in human saliva","volume":"219","author":"Ferreira","year":"2020","journal-title":"Talanta"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Charbaji, A., Smith, W., Anagnostopoulos, C., and Faghri, M. (2020). Zinculose: A new fibrous material with embedded zinc particles. Eng. Sci. Technol. Int. J.","DOI":"10.1016\/j.jestch.2020.09.005"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1021\/acssensors.0c00291","article-title":"Ultrasensitive Detection of Nitrite through Implementation of N-(1-Naphthyl)ethylenediamine-Grafted Cellulose into a Paper-Based Device","volume":"5","author":"Mako","year":"2020","journal-title":"ACS Sens."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1493","DOI":"10.1021\/ac50045a032","article-title":"Kinetics and mechanisms of the Griess reaction","volume":"51","author":"Fox","year":"1979","journal-title":"Anal. Chem."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.talanta.2016.12.044","article-title":"Methods for the detection and determination of nitrite and nitrate: A review","volume":"165","author":"Wang","year":"2017","journal-title":"Talanta"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"127492","DOI":"10.1016\/j.chemosphere.2020.127492","article-title":"Recent progress in sensing nitrate, nitrite, phosphate, and ammonium in aquatic environment","volume":"259","author":"Mahmud","year":"2020","journal-title":"Chemosphere"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"421","DOI":"10.2116\/analsci.18P497","article-title":"Microliter Operation for Determination of Nitrate-Nitrogen via Simple Zinc Reduction and Color Formation in a Well Plate with a Smartphone","volume":"35","author":"Jaikang","year":"2019","journal-title":"Anal. Sci."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1039\/C6AY03190K","article-title":"A colorimetric method for use within portable test kits for nitrate determination in various water matrices","volume":"9","author":"Murray","year":"2017","journal-title":"Anal. Methods"},{"key":"ref_45","unstructured":"(2020, November 23). Goals & Expected Outcomes\u2014RI NSF EPSCoR. Available online: https:\/\/web.uri.edu\/rinsfepscor\/expected-outcomes-2\/."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Kudo, H., Yamada, K., Watanabe, D., Suzuki, K., and Citterio, D. (2017). Paper-Based Analytical Device for Zinc Ion Quantification in Water Samples with Power-Free Analyte Concentration. Micromachines, 8.","DOI":"10.3390\/mi8040127"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"65","DOI":"10.2116\/analsci.34.65","article-title":"Highly Sensitive Paper-based Analytical Devices with the Introduction of a Large-Volume Sample via Continuous Flow","volume":"34","author":"Shimada","year":"2018","journal-title":"Anal. Sci."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.marchem.2018.10.008","article-title":"Low-nutrient organic matter in the Sargasso Sea thermocline: A hypothesis for its role, identity, and carbon cycle implications","volume":"207","author":"Fawcett","year":"2018","journal-title":"Mar. Chem."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"066502","DOI":"10.1063\/1.4902246","article-title":"Colored wax-printed timers for two-dimensional and three-dimensional assays on paper-based devices","volume":"8","author":"Weng","year":"2014","journal-title":"Biomicrofluidics"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1007\/s00216-009-3195-9","article-title":"Quantitative biomarker assay with microfluidic paper-based analytical devices","volume":"396","author":"Li","year":"2009","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1821","DOI":"10.1007\/s00216-010-3718-4","article-title":"Paper-based microfluidic devices for analysis of clinically relevant analytes present in urine and saliva","volume":"397","author":"Klasner","year":"2010","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1373\/clinchem.2008.105320","article-title":"Use of Colorimetric Test Strips for Monitoring the Effect of Hemodialysis on Salivary Nitrite and Uric Acid in Patients with End-Stage Renal Disease: A Proof of Principle","volume":"54","author":"Blicharz","year":"2008","journal-title":"Clin. Chem."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"7311","DOI":"10.1039\/C5AY00466G","article-title":"Colorimetric determination of nitrite in clinical, food and environmental samples using microfluidic devices stamped in paper platforms","volume":"7","author":"Cardoso","year":"2015","journal-title":"Anal. Methods"},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Miller, J.N., and Miller, J.C. (2005). Statistics and Chemometrics for Analytical Chemistry, Pearson. [5th ed.].","DOI":"10.1002\/9780470988459.ch8"},{"key":"ref_55","first-page":"179","article-title":"Infrared Lightbox and iPhone App for Improving Detection Limit of Phosphate Detecting Dip Strips","volume":"14","author":"Ribeiro","year":"2020","journal-title":"Int. J. Chem. Mol. Eng."},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Heidari-Bafroui, H., Ribeiro, B., Charbaji, A., Anagnostopoulos, C., and Faghri, M. (2020). Portable infrared lightbox for improving the detection limits of paper-based phosphate devices. Measurement, 108607.","DOI":"10.1016\/j.measurement.2020.108607"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.snb.2016.07.159","article-title":"A smartphone-based optical platform for colorimetric analysis of microfluidic device","volume":"239","author":"Kim","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.aca.2013.11.044","article-title":"Determination of nitrite in saliva using microfluidic paper-based analytical devices","volume":"809","author":"Bhakta","year":"2014","journal-title":"Anal. Chim. Acta"},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Lai, Y.-T., Tsai, C.-H., Hsu, J., and Lu, Y.-W. (2019). Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA. Micromachines, 10.","DOI":"10.3390\/mi10120837"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1039\/C4LC01155D","article-title":"A versatile valving toolkit for automating fluidic operations in paper microfluidic devices","volume":"15","author":"Toley","year":"2015","journal-title":"Lab Chip"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/1\/102\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:46:26Z","timestamp":1760179586000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/1\/102"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,26]]},"references-count":60,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,1]]}},"alternative-id":["s21010102"],"URL":"https:\/\/doi.org\/10.3390\/s21010102","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12,26]]}}}