{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T17:09:09Z","timestamp":1791047349449,"version":"4.1.0"},"reference-count":43,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2020,12,26]],"date-time":"2020-12-26T00:00:00Z","timestamp":1608940800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["NRF-2020R1A2C1008883"],"award-info":[{"award-number":["NRF-2020R1A2C1008883"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Compared to laparoscopy, robotics-assisted minimally invasive surgery has the problem of an absence of force feedback, which is important to prevent a breakage of the suture. To overcome this problem, surgeons infer the suture force from their proprioception and 2D image by comparing them to the training experience. Based on this idea, a deep-learning-based method using a single image and robot position to estimate the tensile force of the sutures without a force sensor is proposed. A neural network structure with a modified Inception Resnet-V2 and Long Short Term Memory (LSTM) networks is used to estimate the suture pulling force. The feasibility of proposed network is verified using the generated DB, recording the interaction under the condition of two different artificial skins and two different situations (in vivo and in vitro) at 13 viewing angles of the images by changing the tool positions collected from the master-slave robotic system. From the evaluation conducted to show the feasibility of the interaction force estimation, the proposed learning models successfully estimated the tensile force at 10 unseen viewing angles during training.<\/jats:p>","DOI":"10.3390\/s21010110","type":"journal-article","created":{"date-parts":[[2020,12,27]],"date-time":"2020-12-27T20:52:21Z","timestamp":1609102341000},"page":"110","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":41,"title":["Vision-Based Suture Tensile Force Estimation in Robotic Surgery"],"prefix":"10.3390","volume":"21","author":[{"given":"Won-Jo","family":"Jung","sequence":"first","affiliation":[{"name":"Department of Mechanical, Robotics and Energy Engineering, Dongguk University, 30, Pildong-ro 1gil, Jung-gu, Seoul 04620, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyung-Soo","family":"Kwak","sequence":"additional","affiliation":[{"name":"Department of Mechanical, Robotics and Energy Engineering, Dongguk University, 30, Pildong-ro 1gil, Jung-gu, Seoul 04620, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Soo-Chul","family":"Lim","sequence":"additional","affiliation":[{"name":"Department of Mechanical, Robotics and Energy Engineering, Dongguk University, 30, Pildong-ro 1gil, Jung-gu, Seoul 04620, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,12,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.rcim.2010.06.009","article-title":"Surgical robotics: Reviewing the past, analysing the present, imagining the future","volume":"27","author":"Gomes","year":"2011","journal-title":"Robot. Comput. Manuf."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Marb\u00e1n, A., Casals, A., Fern\u00e1ndez, J., and Amat, J. (2013, January 28\u201329). Haptic Feedback in Surgical Robotics: Still a Challenge. Proceedings of the First Iberian Robotics Conference (ROBOT2013), Madrid, Spain.","DOI":"10.1007\/978-3-319-03413-3_18"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Garbey, M., Bass, B.L., Berceli, S., Collet, C., and Cerveri, P. (2014). Robot Interaction Control in Medicine and Surgery: Original Results and Open Problems. Computational Surgery and Dual Training: Computing, Robotics and Imaging, Springer.","DOI":"10.1007\/978-1-4614-8648-0"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1007\/s10029-004-0250-5","article-title":"Laparoscopic incisional and ventral hernia repair: Complications? how to avoid and handle","volume":"8","author":"Leblanc","year":"2004","journal-title":"Hernia"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1520\/JFS2003218","article-title":"Postmortem analysis of anastomotic suture line disruption following carotid endarterectomy","volume":"49","author":"Melinek","year":"2004","journal-title":"J. Forensic Sci."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1006\/jsre.2000.5874","article-title":"Surgical Stress and the Gastrointestinal Tract","volume":"92","author":"Anup","year":"2000","journal-title":"J. Surg. Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.bspc.2019.01.011","article-title":"A recurrent convolutional neural network approach for sensorless force estimation in robotic surgery","volume":"50","author":"Marban","year":"2019","journal-title":"Biomed. Signal Process. Control."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1109\/TBME.2018.2869417","article-title":"Suture Breakage Warning System for Robotic Surgery","volume":"66","author":"Abiri","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.jtcvs.2007.08.043","article-title":"Effects of visual force feedback on robot-assisted surgical task performance","volume":"135","author":"Reiley","year":"2008","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1007\/s11548-018-1866-8","article-title":"Conditions for reliable grip force and jaw angle estimation of da Vinci surgical tools","volume":"14","author":"Stephens","year":"2019","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2467","DOI":"10.1109\/JSEN.2019.2951782","article-title":"A High-Sensitivity Fiber Bragg Grating-Based Distal Force Sensor for Laparoscopic Surgery","volume":"20","author":"Shi","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1049\/el.2013.4182","article-title":"Grip force measurement of forceps with fibre Bragg grating sensors","volume":"50","author":"Lim","year":"2014","journal-title":"Electron. Lett."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1080\/24699322.2018.1557887","article-title":"A sensorless force-feedback system for robot-assisted laparoscopic surgery","volume":"24","author":"Zhao","year":"2019","journal-title":"Comput. Assist. Surg."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"5274","DOI":"10.1109\/JSEN.2019.2903776","article-title":"External Force Self-Sensing Based on Cable-Tension Disturbance Observer for Surgical Robot End-Effector","volume":"19","author":"Wang","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Hwang, W., and Lim, S.-C. (2017). Inferring Interaction Force from Visual Information without Using Physical Force Sensors. Sensors, 17.","DOI":"10.3390\/s17112455"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1801","DOI":"10.1007\/s12541-014-0532-5","article-title":"Correlation of the holes quality with the force signals in a mi-crodrilling process of a sintered tungsten-copper alloy","volume":"15","author":"Beruvides","year":"2014","journal-title":"Int. J. Precis. Eng. Man."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1016\/j.engstruct.2018.12.056","article-title":"Experimental study on shear deformation of reinforced concrete beams using digital image correlation","volume":"181","author":"Huang","year":"2019","journal-title":"Eng. Struct."},{"key":"ref_18","first-page":"53","article-title":"A vision-based approach for estimating contact forces: Applications to robot-assisted surgery","volume":"2","author":"Kennedy","year":"2005","journal-title":"Appl. Bionics Biomech."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/S0924-4247(01)00705-1","article-title":"Vision-based sensing of forces in elastic objects","volume":"94","author":"Wang","year":"2001","journal-title":"Sens. Actuators A Phys."},{"key":"ref_20","unstructured":"Greminger, M.A., and Nelson, B.J. (2003, January 27\u201331). Modeling elastic objects with neural networks for vision-based force measurement. Proceedings of the IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS 2003), Las Vegas, NV, USA."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1016\/j.jbiomech.2013.12.007","article-title":"Vision-based force measurement using neural networks for biological cell mi-croinjection","volume":"47","author":"Karimirad","year":"2014","journal-title":"J. Biomech."},{"key":"ref_22","unstructured":"Kim, W., Seung, S., Choi, H., Park, S., Ko, S.Y., and Park, J.-O. (2012, January 17\u201321). Image-based force estimation of deformable tissue using depth map for single-port surgical robot. Proceedings of the 12th International Conference on Control, Automation and Systems (ICCAS 2012), Jeju Island, Korea."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"5204","DOI":"10.1109\/TII.2019.2900119","article-title":"A Sensorless Hand Guiding Scheme Based on Model Identification and Control for Industrial Robot","volume":"15","author":"Zhang","year":"2019","journal-title":"IEEE Trans. Ind. Inform."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1007\/s11548-016-1361-z","article-title":"Vision-based deformation recovery for intraoperative force estimation of tool\u2013tissue interaction for neurosurgery","volume":"11","author":"Giannarou","year":"2016","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Naeini, F.B., Makris, D., Gan, D., and Zweiri, Y. (2020). Dynamic-Vision-Based Force Measurements Using Convolutional Recurrent Neural Networks. Sensors, 20.","DOI":"10.3390\/s20164469"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Yuan, W., Dong, S., and Adelson, E.H. (2017). GelSight: High-Resolution Robot Tactile Sensors for Estimating Geometry and Force. Sensors, 17.","DOI":"10.3390\/s17122762"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Donlon, E., Dong, S., Liu, M., Li, J., Adelson, E., and Rodriguez, A. (2018, January 1\u20135). GelSlim: A High-Resolution, Compact, Robust, and Calibrated Tactile-sensing Finger. Proceedings of the IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS 2018), Madrid, Spain.","DOI":"10.1109\/IROS.2018.8593661"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"101730","DOI":"10.1016\/j.media.2020.101730","article-title":"Deep learning with 4D spatio-temporal data representations for OCT-based force estimation","volume":"64","author":"Gessert","year":"2020","journal-title":"Med. Image Anal."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"150237","DOI":"10.1109\/ACCESS.2019.2947090","article-title":"Sequential Image-Based Attention Network for Inferring Force Estimation Without Haptic Sensor","volume":"7","author":"Shin","year":"2019","journal-title":"IEEE Access"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"8863","DOI":"10.1109\/JSEN.2018.2868332","article-title":"Interaction Force Estimation Using Camera and Electrical Current Without Force\/Torque Sensor","volume":"18","author":"Lee","year":"2018","journal-title":"IEEE Sens. J."},{"key":"ref_31","unstructured":"Simonyan, K., and Zisserman, A. (2014). Very deep convolutional networks for large-scale image recognition. arXiv."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1145\/3065386","article-title":"ImageNet classification with deep convolutional neural networks","volume":"60","author":"Krizhevsky","year":"2017","journal-title":"Commun. ACM"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Szegedy, C., Liu, W., Jia, Y., Sermanet, P., Reed, S., Anguelov, D., Erhan, D., Vanhoucke, V., and Rabinovich, A. (2014, January 23\u201328). Going deeper with convolutions. Proceedings of the Conference on Computer Vision and Pattern Recognition, Columbus, OH, USA.","DOI":"10.1109\/CVPR.2015.7298594"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Szegedy, C., Ioffe, S., Vanhoucke, V., and Alemi, A.A. (2017, January 4\u20139). Inception-v4, inception-resnet and the impact of residual connections on learning. Proceedings of the 31st AAAI Conference on Artificial Intelligence, San Francisco, CA, USA.","DOI":"10.1609\/aaai.v31i1.11231"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Szegedy, C., Vanhoucke, V., Ioffe, S., Shlens, J., and Wojna, Z. (2016, January 27\u201330). Rethinking the inception architecture for computer vision. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, Las Vegas, NV, USA.","DOI":"10.1109\/CVPR.2016.308"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1109\/TOH.2016.2557331","article-title":"Pseudo-Haptic Feedback in Teleoperation","volume":"9","author":"Neupert","year":"2016","journal-title":"IEEE Trans. Haptics"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1167\/tvst.8.3.26","article-title":"Robot-Assisted Simulated Strabismus Surgery","volume":"8","author":"Bourcier","year":"2019","journal-title":"Transl. Vis. Sci. Technol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1126\/science.1206157","article-title":"Epidermal Electronics","volume":"333","author":"Kim","year":"2011","journal-title":"Science"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1007\/s12262-010-0158-5","article-title":"An In Vitro and In Vivo Evaluation of Tensile Strength and Durability of Seven Suture Materials in Various pH and Different Conditions: An Experimental Study in Rats","volume":"72","author":"Karabulut","year":"2010","journal-title":"Indian J. Surg."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Feng, R., Gu, J., Qiao, Y., and Dong, C. (2019, January 16\u201317). Suppressing Model Overfitting for Image Super-Resolution Networks. Proceedings of the IEEE\/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW 2019), Long Beach, CA, USA.","DOI":"10.1109\/CVPRW.2019.00248"},{"key":"ref_41","unstructured":"Kingma, D.P., and Ba, J. (2015, January 5\u20138). Adam: A method for stochastic optimization. Proceedings of the 3rd International Conference for Learning Representations (ICLR), San Diego, CA, USA."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1109\/TOH.2016.2616874","article-title":"The role of direct and visual force feedback in suturing using a 7-DOF dual-arm teleoperated system","volume":"10","author":"Talasaz","year":"2016","journal-title":"IEEE Trans. Haptics"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1097\/00000658-198103000-00021","article-title":"Mechanical properties of suture materials: An important characterization","volume":"193","author":"Chu","year":"1981","journal-title":"Ann. Surg."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/1\/110\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:46:34Z","timestamp":1760179594000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/1\/110"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,26]]},"references-count":43,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,1]]}},"alternative-id":["s21010110"],"URL":"https:\/\/doi.org\/10.3390\/s21010110","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12,26]]}}}