{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T03:29:25Z","timestamp":1760239765288,"version":"build-2065373602"},"reference-count":33,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2020,12,29]],"date-time":"2020-12-29T00:00:00Z","timestamp":1609200000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["1726512","1618731"],"award-info":[{"award-number":["1726512","1618731"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The present work details a novel approach to increase the transmitting sensitivity of piezoelectric micromachined ultrasonic transducer arrays and performing the direct modulation of digital information on the same device. The direct modulation system can reach 3\u00d7 higher signal-to-noise ratio level and 3\u00d7 higher communication range (from 6.2 cm boosted to 18.6 cm) when compared to more traditional continuous wave drive at the same energy consumption levels. When compared for the same transmission performance, the direct modulation consumes 80% less energy compared to the continues wave. The increased performance is achieved with a switching circuit that allows to generate a short high-AC voltage on the ultrasonic array, by using an LC tank and a bipolar junction transistor, starting with a low-DC voltage, making it CMOS-compatible. Since the modulation signal can directly be formed by the transmitted bits (on\/off keying encoding) this also serve as the modulation for the data itself, hence direct modulation. The working principle of the circuit is described, optimization is performed relative to several circuital parameters and a high-performance experimental application is demonstrated.<\/jats:p>","DOI":"10.3390\/s21010157","type":"journal-article","created":{"date-parts":[[2020,12,29]],"date-time":"2020-12-29T19:55:25Z","timestamp":1609271725000},"page":"157","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Modeling and Optimization of Directly Modulated Piezoelectric Micromachined Ultrasonic Transducers"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5650-5441","authenticated-orcid":false,"given":"Flavius","family":"Pop","sequence":"first","affiliation":[{"name":"Electrical and Computer Engineering Department, Northeastern University, Boston, MA 02115, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernard","family":"Herrera","sequence":"additional","affiliation":[{"name":"Electrical and Computer Engineering Department, Northeastern University, Boston, MA 02115, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristian","family":"Cassella","sequence":"additional","affiliation":[{"name":"Electrical and Computer Engineering Department, Northeastern University, Boston, MA 02115, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matteo","family":"Rinaldi","sequence":"additional","affiliation":[{"name":"Electrical and Computer Engineering Department, Northeastern University, Boston, MA 02115, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,12,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1061\/(ASCE)0893-1321(2003)16:2(76)","article-title":"Capacitive Micromachined Ultrasonic Transducers: Theory and Technology","volume":"16","author":"Ergun","year":"2003","journal-title":"J. Aerosp. Eng."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2242","DOI":"10.1109\/TUFFC.2005.1563267","article-title":"Capacitive Micromachined Ultrasonic Transducers: Fabrication Technology","volume":"52","author":"Ergun","year":"2005","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1109\/TUFFC.2005.1417268","article-title":"Piezoelectric micromachined ultrasonic transducers: Modeling the influence of structural parameters on device performance","volume":"52","author":"Akasheh","year":"2005","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2276","DOI":"10.1109\/TUFFC.2005.1563270","article-title":"Piezoelectric micromachined ultrasonic transducers based on PZT thin films","volume":"52","author":"Muralt","year":"2005","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Tang, H., Lu, Y., Fung, S., Tsai, J.M., Daneman, M., Horsley, D.A., and Boser, B.E. (2015, January 21\u201325). Pulse-echo ultrasonic fingerprint sensor on a chip. Proceedings of the 2015 Transducers\u20142015 18th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS 2015, Anchorage, AK, USA.","DOI":"10.1109\/TRANSDUCERS.2015.7181013"},{"key":"ref_6","unstructured":"Horsley, D.A., Lu, Y., Tang, H.Y., Jiang, X., Boser, B.E., Tsai, J.M., Ng, E.J., and Daneman, M.J. (September, January ). Ultrasonic fingerprint sensor based on a PMUT array bonded to CMOS circuitry. Proceedings of the IEEE International Ultrasonics Symposium, IUS, Tours, France."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1401","DOI":"10.1109\/TUFFC.2017.2703606","article-title":"Ultrasonic Fingerprint Sensor with Transmit Beamforming Based on a PMUT Array Bonded to CMOS Circuitry","volume":"64","author":"Jiang","year":"2017","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Liu, X., Chen, X., Le, X., Xu, Z., Wu, C., and Xie, J. (2018, January 22\u201326). A High-Performance Square pMUT for Range-finder. Proceedings of the NEMS 2018\u201413th Annual IEEE International Conference on Nano\/Micro Engineered and Molecular Systems, Singapore.","DOI":"10.1109\/NEMS.2018.8556913"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Rozen, O., Block, S.T., Mo, X., Bland, W., Hurst, P., Tsai, J.M., Daneman, M., Amirtharajah, R., and Horsley, D.A. (2016, January 24\u201328). Monolithic MEMS-CMOS ultrasonic rangefinder based on dual-electrode PMUTs. Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), Shanghai, China.","DOI":"10.1109\/MEMSYS.2016.7421571"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Zhou, Z., Yoshida, S., and Tanaka, S. (2017, January 18\u201322). Monocrystalline PMNN-PZT thin film ultrasonic rangefinder with 2 m range at 1 volt drive. Proceedings of the TRANSDUCERS 2017\u201419th International Conference on Solid-State Sensors, Actuators and Microsystems, Kaohsiung, Taiwan.","DOI":"10.1109\/TRANSDUCERS.2017.7994014"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"084004","DOI":"10.1088\/1361-6439\/ab257f","article-title":"Acoustic power transfer for biomedical implants using piezoelectric receivers: Effects of misalignment and misorientation","volume":"29","author":"Basaeri","year":"2019","journal-title":"J. Micromech. Microeng."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Mehdizadeh, E., and Piazza, G. (2017, January 6\u20139). AlN on SOI pMUTs for ultrasonic power transfer. Proceedings of the IEEE International Ultrasonics Symposium, IUS, Washington, DC, USA.","DOI":"10.1109\/ULTSYM.2017.8092630"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Herrera, B., Pop, F., Cassella, C., and Rinaldi, M. (2019, January 23\u201327). AlN PMUT-based Ultrasonic Power Transfer Links for Implantable Electronics. Proceedings of the 2019 20th International Conference on Solid-State Sensors, Actuators and Microsystems and Eurosensors XXXIII, TRANSDUCERS 2019 and EUROSENSORS XXXIII, Berlin, Germany.","DOI":"10.1109\/TRANSDUCERS.2019.8808320"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Dausch, D.E., Gilchrist, K.H., Carlson, J.R., Castellucci, J.B., Chou, D.R., and Von Ramm, O.T. (2010, January 11\u201314). Improved pulse-echo imaging performance for flexure-mode pMUT arrays. Proceedings of the IEEE Ultrasonics Symposium, San Diego, CA, USA.","DOI":"10.1109\/ULTSYM.2010.5935826"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"8020","DOI":"10.3390\/s150408020","article-title":"Piezoelectric Micromachined Ultrasound Transducer (PMUT) Arrays for Integrated Sensing, Actuation and Imaging","volume":"15","author":"Qiu","year":"2015","journal-title":"Sensors"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Akhbari, S., Sammoura, F., Shelton, S., Yang, C., Horsley, D., and Lin, L. (2014, January 26\u201330). Highly responsive curved aluminum nitride PMUT. Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), San Francisco, CA, USA.","DOI":"10.1109\/MEMSYS.2014.6765589"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"9624","DOI":"10.3390\/s130809624","article-title":"An Ultra-High Element Density pMUT Array with Low Crosstalk for 3-D Medical Imaging","volume":"13","author":"Yang","year":"2013","journal-title":"Sensors"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Smyth, K.M., Sodini, C.G., and Kim, S.G. (2017, January 18\u201322). High electromechanical coupling piezoelectric micro-machined ultrasonic transducer (PMUT) elements for medical imaging. Proceedings of the TRANSDUCERS 2017-19th International Conference on Solid-State Sensors, Actuators and Microsystems, Kaohsiung, Taiwan.","DOI":"10.1109\/TRANSDUCERS.2017.7994211"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Pop, F.V., Herrera, B., Cassella, C., Chen, G., Demirors, E., Guida, R., Melodia, T., and Rinaldi, M. (2018, January 22\u201325). Novel pMUT-Based Acoustic Duplexer for Underwater and Intrabody Communication. Proceedings of the 2018 IEEE International Ultrasonics Symposium (IUS), Kobe, Japan.","DOI":"10.1109\/ULTSYM.2018.8579709"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Pop, F., Herrera, B., Zhu, W., Assylbekova, M., Cassella, C., McGruer, N., and Rinaldi, M. (2019, January 23\u201327). Zero-Power Acoustic Wake-Up Receiver based on dMUT Transmitter, pMUTs Arrays Receivers and MEMS Switches for Intrabody Links. Proceedings of the Transducers-Eurosensors, 2019 IEEE International, Berlin, Germany.","DOI":"10.1109\/TRANSDUCERS.2019.8808176"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Sadeghpour, S., Kraft, M., and Puers, R. (2019, January 23\u201327). Highly Efficient Piezoelectric Micromachined Ultrasound Transducer (PMUT) for Underwater Sensor Networks. Proceedings of the 2019 20th International Conference on Solid-State Sensors, Actuators and Microsystems and Eurosensors XXXIII, TRANSDUCERS 2019 and EUROSENSORS XXXIII, Berlin, Germany.","DOI":"10.1109\/TRANSDUCERS.2019.8808204"},{"key":"ref_22","unstructured":"Sadeghpour, S., Kraft, M., and Puers, R. (October, January ). PMUTs Array with Dynamic Directivity: A Study of its Underwater Acoustic Power Intensity. Proceedings of the IEEE International Ultrasonics Symposium, IUS, Kobe, Japan."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Liu, W., He, L., Wang, X., Zhou, J., Xu, W., Smagin, N., Toubal, M., Yu, H., Gu, Y., and Xu, J. (2019). 3D FEM Analysis of High-Frequency AlN-Based PMUT Arrays on Cavity SOI. Sensors, 19, Available online: https:\/\/www.mdpi.com\/1424-8220\/19\/20\/4450.","DOI":"10.3390\/s19204450"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Keller, S.D., Palmer, W.D., and Joines, W.T. (2006, January 9\u201314). Direct antenna modulation: Analysis, design, and experiment. Proceedings of the IEEE Antennas and Propagation Society, AP-S International Symposium (Digest), Albuquerque, NM, USA.","DOI":"10.1109\/APS.2006.1710677"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2674","DOI":"10.1109\/JSSC.2008.2004864","article-title":"Transmitter architectures based on near-field direct antenna modulation","volume":"43","author":"Babakhani","year":"2008","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_26","unstructured":"Yao, W., and Wang, Y. (2004, January 6\u201311). Direct antenna modulation-A promise for ultra-wideband (UWB) transmitting. Proceedings of the IEEE MTT-S International Microwave Symposium Digest, Fort Worth, TX, USA."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1109\/8.777127","article-title":"Direct-signal modulation using a silicon microstrip patch antenna","volume":"47","author":"Fusco","year":"1999","journal-title":"IEEE Trans. Antennas Propag."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1109\/MMM.2008.930674","article-title":"Near-field direct antenna modulation","volume":"10","author":"Babakhani","year":"2009","journal-title":"IEEE Microw. Mag."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Pop, F.V., Herrera, B., Cassella, C., and Rinaldi, M. (2019, January 27\u201331). Direct modulation piezoelectric micro-machined ultrasonic transducer system (dmut). Proceedings of the 2019 IEEE 32nd International Conference on Micro Electro Mechanical Systems (MEMS), Seoul, Korea.","DOI":"10.1109\/MEMSYS.2019.8870759"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Huang, C.H., Gao, H., Torri, G.B., Mao, S., Jeong, Y., Cheyns, D., Rochus, V., and Rottenberg, X. (2018, January 15\u201318). Design, modelling, and characterization of display compatible pMUT device. Proceedings of the 2018 19th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems, EuroSimE 2018, Toulouse, France.","DOI":"10.1109\/EuroSimE.2018.8369931"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"4659","DOI":"10.1007\/s00542-016-3205-8","article-title":"Modeling and process design optimization of a piezoelectric micromachined ultrasonic transducers (PMUT) using lumped elements parameters","volume":"23","author":"Kouki","year":"2017","journal-title":"Microsyst. Technol."},{"key":"ref_32","unstructured":"Smyth, K.M. (2012). Design and Modeling of a PZT Thin Film Based Piezoelectric Micromachined Ultrasonic Transducer (PMUT). [Ph.D. Thesis, Massachusetts Institute of Technology]. Available online: https:\/\/dspace.mit.edu\/handle\/1721.1\/74942."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2336","DOI":"10.1109\/TUFFC.2020.3002973","article-title":"Enabling Real-Time Monitoring of Intrabody Networks through the Acoustic Discovery Architecture","volume":"67","author":"Pop","year":"2020","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/1\/157\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:47:21Z","timestamp":1760179641000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/1\/157"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,29]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,1]]}},"alternative-id":["s21010157"],"URL":"https:\/\/doi.org\/10.3390\/s21010157","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2020,12,29]]}}}