{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T03:29:23Z","timestamp":1760239763826,"version":"build-2065373602"},"reference-count":24,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2020,12,29]],"date-time":"2020-12-29T00:00:00Z","timestamp":1609200000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["HE 5637\/6-1","GE 986\/3-1"],"award-info":[{"award-number":["HE 5637\/6-1","GE 986\/3-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The measurement and analysis of the arterial pulse wave provides information about the state of vascular health. When measuring blood pressure according to Riva-Rocci, the systolic and diastolic blood pressure is measured non-invasively with an inflatable pressure cuff on the upper arm. Today\u2019s blood pressure monitors analyze the pulse wave in reference to the rising or falling cuff pressure. With the help of additional pulse wave analysis, one can determine the pulse rate and the heart rate variability. In this paper, we investigated the concept, the construction, and the limitations of ultrawideband (UWB) radar and continuous wave (CW) radar, which provide continuous and non-invasive pulse wave measurements. We integrated the sensors into a complete measurement system. We measured the pulse wave of the cuff pressure, the radar sensor (both UWB and CW), the optical sensor, and ultrasonic Doppler as a reference. We discussed the results and the sensor characteristics. The main conclusion was that the resolution of the pulse radar was too low, even with a maximum bandwidth of 10 GHz, to measure pulse waves reliably. The continuous wave radar provides promising results for a phantom if adjusted properly with phase shifts and frequency. In the future, we intend to develop a CW radar solution with frequency adaption.<\/jats:p>","DOI":"10.3390\/s21010165","type":"journal-article","created":{"date-parts":[[2020,12,29]],"date-time":"2020-12-29T19:55:25Z","timestamp":1609271725000},"page":"165","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Brachialis Pulse Wave Measurements with Ultra-Wide Band and Continuous Wave Radar, Photoplethysmography and Ultrasonic Doppler Sensors"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7619-8015","authenticated-orcid":false,"given":"Horst","family":"Hellbr\u00fcck","sequence":"first","affiliation":[{"name":"Technische Hochschule L\u00fcbeck, University of Applied Sciences, 23562 L\u00fcbeck, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gunther","family":"Ardelt","sequence":"additional","affiliation":[{"name":"Technische Hochschule L\u00fcbeck, University of Applied Sciences, 23562 L\u00fcbeck, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Wegerich","sequence":"additional","affiliation":[{"name":"Institute of Biomedical Engineering, University of L\u00fcbeck, 23562 L\u00fcbeck, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hartmut","family":"Gehring","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, 23538 L\u00fcbeck, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,12,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1093\/bja\/aeq143","article-title":"Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: Assessment during general anaesthesia","volume":"105","author":"Jeleazcov","year":"2010","journal-title":"Br. J. Anaesth."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Sol\u00e0, J., and Delgado, R. (2019). The Handbook of Cuffless Blood Pressure Monitoring: A Practical Guide for Clinicians, Researchers, and Engineers, Springer.","DOI":"10.1007\/978-3-030-24701-0"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1016\/j.ultrasmedbio.2011.01.020","article-title":"Toward noninvasive blood pressure assessment in arteries by using ultrasound","volume":"37","author":"Beulen","year":"2011","journal-title":"Ultrasound Med. Biol."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Bi, S., Liu, X., and Matthews, D. (2015, January 13\u201315). An experimental study of 2-D cardiac motion pattern based on contact radar measurement. Proceedings of the 2015 IEEE 16th Annual Wireless and Microwave Technology Conference (WAMICON), Cocoa Beach, FL, USA.","DOI":"10.1109\/WAMICON.2015.7120390"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Bi, S., Zeng, J., Bekbalanova, M., Matthews, D., and Liu, X.L. (2015, January 24\u201327). Contact-based radar measurement of cardiac motion\u2014A position and polarization study. Proceedings of the 2016 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS), Austin, TX, USA.","DOI":"10.1109\/BIOWIRELESS.2016.7445553"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1109\/MAES.2008.4693985","article-title":"UWB radar for patient monitoring","volume":"23","author":"Immoreev","year":"2008","journal-title":"IEEE Aerosp. Electron. Syst. Mag."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Immoreev, I.Y. (2006, January 18\u201322). Practical Application of Ultra-Wideband Radars. Proceedings of the 2006 3rd International Conference on Ultrawideband and Ultrashort Impulse Signals, Sevastopol, Ukraine.","DOI":"10.1109\/UWBUS.2006.307156"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Kim, I., and Bhagat, Y.A. (2016, January 16\u201320). Towards development of a mobile RF Doppler sensor for continuous heart rate variability and blood pressure monitoring. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7591455"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Shi, K., Schellenberger, S., Steigleder, T., Michler, F., Lurz, F., Weigel, R., and Koelpin, A. (2018, January 6\u20139). Contactless Carotid Pulse Measurement Using Continuous Wave Radar. Proceedings of the 2018 Asia-Pacific Microwave Conference (APMC), Kyoto, Japan.","DOI":"10.23919\/APMC.2018.8617522"},{"key":"ref_10","first-page":"1","article-title":"Blood pressure estimation Using on-body continuous Wave Radar and photoplethysmogram in Various posture and exercise conditions","volume":"9","author":"Ebrahim","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Barnes, F.S. (2018). Biological and Medical Aspects of Electromagnetic Fields, CRC Press.","DOI":"10.1201\/9781315221557"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1007\/s00421-011-1983-3","article-title":"Continuous blood pressure measurement by using the pulse transit time: Comparison to a cuff-based method","volume":"112","author":"Gesche","year":"2012","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1253\/circj.70.1231","article-title":"Pulse Wave Analysis and Pulse Wave Velocity","volume":"70","author":"Hirata","year":"2006","journal-title":"Circ. J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1007\/PL00007261","article-title":"Relationship between the pressure and diameter of the carotid artery in humans","volume":"15","author":"Sugawara","year":"2000","journal-title":"Heart Vessel."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2455","DOI":"10.3906\/elk-1603-115","article-title":"A ternary zero-correlation zone sequence sets construction procedure","volume":"25","author":"Addad","year":"2017","journal-title":"Turk. J. Electr. Eng. Comput. Sci."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1080\/00207177408932701","article-title":"Parameter estimation of discrete-time systems using short-periodic pseudo-random sequences","volume":"19","author":"Funahashi","year":"1974","journal-title":"Int. J. Control"},{"key":"ref_17","unstructured":"Midasala, V., Siddaiah, P., and Bhavanam, S. (2014, January 20\u201321). Design of dipole antenna by using COMSOL Multiphysics Software. Proceedings of the International Conference on Electronics and Communications Engineering (ICECE 2014), Bangalore, India."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Wiwatwithaya, S., Phasukkit, P., Tungjitkusolmun, S., and Wongtrairat, W. (2012, January 29\u201331). Real-time monitoring glucose by used microwave antenna apply to biosensor. Proceedings of the 4th 2011 Biomedical Engineering International Conference, Chiang Mai, Thailand.","DOI":"10.1109\/BMEiCon.2012.6172036"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Alabaster, C. (2012). Pulse Doppler Radar: Principles, Technology, Applications, SciTech Publishing.","DOI":"10.1049\/SBRA024E"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Bilich, C.G. (December, January 29). Bio-medical sensing using Ultra Wideband communications and radar technology: A feasibility study. Proceedings of the 2006 Pervasive Health Conference and Workshops, Pervasive Health, Innsbruck, Austria.","DOI":"10.1109\/PCTHEALTH.2006.361671"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1109\/TMTT.1979.1129561","article-title":"Water-immersed microwave antennas and their application to microwave interrogation of biological targets","volume":"27","author":"Jacobi","year":"1979","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"3500","DOI":"10.1109\/TAP.2005.858598","article-title":"Study of a printed circular disc monopole antenna for UWB systems","volume":"53","author":"Liang","year":"2005","journal-title":"IEEE Trans. Antennas Propag."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Liang, X.L., and Matin, M. (2012). Ultra-wideband antenna and design. Ultra Wideband\u2014Current Status and Future Trends, Intech Open.","DOI":"10.5772\/47805"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1109\/TBCAS.2019.2922775","article-title":"Coherent uwb radar-on-chip for in-body measurement of cardiovascular dynamics","volume":"13","author":"Lauteslager","year":"2019","journal-title":"IEEE Trans. Biomed. Circuits Syst."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/1\/165\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:47:23Z","timestamp":1760179643000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/1\/165"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,29]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,1]]}},"alternative-id":["s21010165"],"URL":"https:\/\/doi.org\/10.3390\/s21010165","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2020,12,29]]}}}