{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T15:30:03Z","timestamp":1780587003416,"version":"3.54.1"},"reference-count":27,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2021,1,9]],"date-time":"2021-01-09T00:00:00Z","timestamp":1610150400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["16ES0752K"],"award-info":[{"award-number":["16ES0752K"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The aim of this work was to extend conventional medical implants by the possibility of communication between them. For reasons of data security and transmitting distances, this communication should be realized using ultrasound, which is generated and detected by capacitive micromachined ultrasonic transducers (CMUTs). These offer the advantage of an inherent high bandwidth and a high integration capability. To protect the surrounding tissue, it has to be encapsulated. In contrast to previous results of other research groups dealing with the encapsulation of CMUTs, the goal here is to integrate the CMUT into the housing of a medical implant. In this work, CMUTs were designed and fabricated for a center frequency of 2 MHz in water and experimentally tested on their characteristics for operation behind layers of Polyether ether ketone (PEEK) and titanium, two typical materials for the housings of medical implants. It could be shown that with silicone as a coupling layer it is possible to operate a CMUT behind the housing of an implant. Although it changes the characteristics of the CMUT, the setup is found to be well suited for communication between two transducers over a distance of at least 8 cm.<\/jats:p>","DOI":"10.3390\/s21020421","type":"journal-article","created":{"date-parts":[[2021,1,10]],"date-time":"2021-01-10T23:03:42Z","timestamp":1610319822000},"page":"421","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Encapsulation of Capacitive Micromachined Ultrasonic Transducers (CMUTs) for the Acoustic Communication between Medical Implants"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5339-8452","authenticated-orcid":false,"given":"Jorge","family":"Oevermann","sequence":"first","affiliation":[{"name":"Ultrasound Department, Fraunhofer-Institute for Biomedical Engineering, 66280 Sulzbach, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Weber","sequence":"additional","affiliation":[{"name":"Ultrasound Department, Fraunhofer-Institute for Biomedical Engineering, 66280 Sulzbach, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5710-0825","authenticated-orcid":false,"given":"Steffen H.","family":"Tretbar","sequence":"additional","affiliation":[{"name":"Ultrasound Department, Fraunhofer-Institute for Biomedical Engineering, 66280 Sulzbach, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,1,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2618","DOI":"10.1109\/TIM.2009.2015639","article-title":"Galvanic Coupling Enabling Wireless Implant Communications","volume":"58","author":"Wegmueller","year":"2009","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Khanna, V.K. (2016). Wireless Communications and Powering of Implants. Implantable Medical Electronics, Springer International Publishing.","DOI":"10.1007\/978-3-319-25448-7_10"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Bos, T., Dehaene, W., and Verhelst, M. (2019, January 17\u201319). Ultrasound In-Body Communication with OFDM through Multipath Realistic Channels. Proceedings of the 2019 IEEE Biomedical Circuits and Systems Conference (BioCAS), Nara, Japan.","DOI":"10.1109\/BIOCAS.2019.8918755"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Demirors, E., Alba, G., Santagati, G.E., and Melodia, T. (2016, January 13\u201315). High data rate ultrasonic communications for wireless intra-body networks. Proceedings of the 2016 IEEE International Symposium on Local and Metropolitan Area Networks (LANMAN), Rome, Italy.","DOI":"10.1109\/LANMAN.2016.7548843"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Basagni, S., Conti, M., Giordano, S., and Stojmenovic, I. (2013). Advances in Underwater Acoustic Networking. Mobile Ad Hoc Networking: Cutting Edge Directions, John Wiley & Sons, Inc.. [2nd ed.].","DOI":"10.1002\/9781118511305"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Brenner, K., Ergun, A.S., Firouzi, K., Rasmussen, M.F., Stedman, Q., and Khuri\u2013Yakub, B.P. (2019). Advances in Capacitive Micromachined Ultrasonic Transducers. Micromachines, 10.","DOI":"10.3390\/mi10020152"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.jmu.2012.02.001","article-title":"Capacitive Micromachined Ultrasonic Transducers. Technology and Application","volume":"20","author":"Salim","year":"2012","journal-title":"J. Med. Ultrasound"},{"key":"ref_8","first-page":"25","article-title":"Evaluation of an Ultrasound-Guided Focused Ultrasound CMUT Probe for Targeted Therapy Applications","volume":"8","author":"Gross","year":"2018","journal-title":"Open J. Appl. Sci."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1109\/TUFFC.2004.1320749","article-title":"Forward-viewing CMUT arrays for medical imaging","volume":"51","author":"Demirci","year":"2004","journal-title":"IEEE Trans. Ultrason."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1088\/0960-1317\/17\/5\/020","article-title":"Biocompatible coatings for CMUTs in a harsh, aqueous environment","volume":"17","author":"Zhuang","year":"2007","journal-title":"J. Micromech. Microeng."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Hsu, T.H., Chen, C.Y., Liu, C.Y., Li, M.H., and Li, S.S. (2018, January 21\u201324). A 200-nm-gap Titanium Nitride Composite CMOS-MEMS CMUT for Biomedical Ultrasounds. Proceedings of the 2018 IEEE International Frequency Control Symposium (IFCS), Olympic Valley, CA, USA.","DOI":"10.1109\/FCS.2018.8597500"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Moini, A., Nikoozadeh, A., Choe, J.W., Khuri-Yakub, B.T., Chang, C., Stephens, D., Smith, L.S., and Sahn, D. (2015, January 6\u20139). Fabrication, Packaging, and Catheter Assembly of 2D CMUT Arrays for Endoscopic Ultrasound and Cardiac Imaging. Proceedings of the ASME 2015 International Technical Conference, San Francisco, CA, USA.","DOI":"10.1115\/IPACK2015-48611"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Jang, J.H., Chang, C., Rasmussen, M.F., Moini, A., Brenner, K., Stephens, D.N., Oralkan, \u00d6., and Khuri-Yakub, B. (2017, January 6\u20139). Integration of a dual-mode catheter for ultrasound image guidance and HIFU ablation using a 2-D CMUT array. Proceedings of the 2017 IEEE International Ultrasonics Symposium (IUS), Washington, DC, USA.","DOI":"10.1109\/ULTSYM.2017.8091627"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Chang, C., Firouzi, K., Park, K.K., Sarioglu, A.F., Nikoozadeh, A., Yoon, H.S., Vaithilingam, S., Carver, T., and Khuri-Yakub, B.T. (2014). Acoustic lens for capacitive micromachined ultrasonic transducers. J. Micromech. Microeng., 24.","DOI":"10.1088\/0960-1317\/24\/8\/085007"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2651","DOI":"10.1109\/TUFFC.2008.980","article-title":"Forward-looking intracardiac ultrasound imaging using a 1-D CMUT array integrated with custom front-end electronics","volume":"55","author":"Nikoozadeh","year":"2008","journal-title":"In IEEE Trans. Ultrason."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1341","DOI":"10.1109\/JMEMS.2010.2076786","article-title":"Encapsulation of Capacitive Micromachined Ultrasonic Transducers Using Viscoelastic Polymer","volume":"19","author":"Lin","year":"2010","journal-title":"J. Microelectromech. Syst."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"La Cour, M.F., Stuart, M.B., Laursen, M.B., Diederichsen, S.E., Thomsen, E.V., and Jensen, J.A. (2014, January 3\u20136). Investigation of PDMS as coating on CMUTs for imaging. Proceedings of the 2014 IEEE International Ultrasonics Symposium (IUS), Chicago, IL, USA.","DOI":"10.1109\/ULTSYM.2014.0645"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Zhang, R., Zhang, W., He, C., Song, J., Mu, L., Cui, J., Zhang, Y., and Xue, C. (2016). Design of capacitive micromachined ultrasonic transducer (CMUT) linear array for underwater imaging. Sens. Rev., 36.","DOI":"10.1108\/SR-05-2015-0076"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Zhou, D., and Greenbaum, E. (2010). Implantable Neural Prostheses 2: Techniques and Engineering Approaches, Springer Science & Business Media.","DOI":"10.1007\/978-0-387-98120-8"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","article-title":"PEEK biomaterials in trauma, orthopedic, and spinal implants","volume":"28","author":"Kurtz","year":"2007","journal-title":"Biomaterials"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"(2020, December 12). Wacker Elastosil E43 Transparent [Online], Technical Data. Available online: https:\/\/www.wacker.com\/h\/de-de\/medias\/ELASTOSIL-E43-TRANSPARENT-en-2020.07.01.pdf.","DOI":"10.7241\/ourd.2021e.43"},{"key":"ref_22","unstructured":"(2020, December 12). OnScale Lab. Available online: https:\/\/onscale.com\/lab."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"3768","DOI":"10.1007\/s10853-010-4428-1","article-title":"Ultrasonic evaluation of polyether ether ketone and carbon fiber-reinforced PEEK","volume":"45","author":"DFitch","year":"2010","journal-title":"J. Mater. Sci."},{"key":"ref_24","unstructured":"Gordon, S.K. (1987). Acoustic Waves: Devices, Imaging, and Analog Signal Processing, Prentice-Hall."},{"key":"ref_25","unstructured":"(2020, December 12). 3M Fluorinert Electronic Liquid FC-72 [Online], Technical Data. Available online: https:\/\/multimedia.3m.com\/mws\/media\/64892O\/3m-fluorinert-electronic-liquid-fc72-en.pdf."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Shishitani, T., Yoshizawa, S., and Umemura, S. (2010, January 11\u201314). Change in acoustic impedance and sound speed of HIFU-exposed chicken breast muscle. Proceedings of the 2010 IEEE International Ultrasonics Symposium, San Diego, CA, USA.","DOI":"10.1109\/ULTSYM.2010.5935709"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1016\/0041-624X(79)90054-4","article-title":"Attenuation of ultrasound in skeletal muscle","volume":"17","author":"Nassiri","year":"1979","journal-title":"Ultrasonics"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/2\/421\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:09:00Z","timestamp":1760159340000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/2\/421"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,9]]},"references-count":27,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2021,1]]}},"alternative-id":["s21020421"],"URL":"https:\/\/doi.org\/10.3390\/s21020421","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,9]]}}}