{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T05:05:27Z","timestamp":1787029527834,"version":"3.56.0"},"reference-count":79,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2021,1,24]],"date-time":"2021-01-24T00:00:00Z","timestamp":1611446400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Wearable devices are pervasive solutions for increasing work efficiency, improving workers\u2019 well-being, and creating interactions between users and the environment anytime and anywhere. Although several studies on their use in various fields have been performed, there are no systematic reviews on their utilisation in ergonomics. Therefore, we conducted a systematic review to identify wearable devices proposed in the scientific literature for ergonomic purposes and analyse how they can support the improvement of ergonomic conditions. Twenty-eight papers were retrieved and analysed thanks to eleven comparison dimensions related to ergonomic factors, purposes, and criteria, populations, application and validation. The majority of the available devices are sensor systems composed of different types and numbers of sensors located in diverse body parts. These solutions also represent the technology most frequently employed for monitoring and reducing the risk of awkward postures. In addition, smartwatches, body-mounted smartphones, insole pressure systems, and vibrotactile feedback interfaces have been developed for evaluating and\/or controlling physical loads or postures. The main results and the defined framework of analysis provide an overview of the state of the art of smart wearables in ergonomics, support the selection of the most suitable ones in industrial and non-industrial settings, and suggest future research directions.<\/jats:p>","DOI":"10.3390\/s21030777","type":"journal-article","created":{"date-parts":[[2021,1,25]],"date-time":"2021-01-25T12:28:31Z","timestamp":1611577711000},"page":"777","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":151,"title":["Wearable Devices for Ergonomics: A Systematic Literature Review"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6679-0362","authenticated-orcid":false,"given":"Elena","family":"Stefana","sequence":"first","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, University of Brescia, via Branze 38, 25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3502-9092","authenticated-orcid":false,"given":"Filippo","family":"Marciano","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, University of Brescia, via Branze 38, 25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4508-8811","authenticated-orcid":false,"given":"Diana","family":"Rossi","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, University of Brescia, via Branze 38, 25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6351-6042","authenticated-orcid":false,"given":"Paola","family":"Cocca","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, University of Brescia, via Branze 38, 25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2938-4864","authenticated-orcid":false,"given":"Giuseppe","family":"Tomasoni","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, University of Brescia, via Branze 38, 25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,1,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1007\/978-3-030-22216-1_20","article-title":"Continuous measurement of muscle fatigue using wearable sensors during light manual operations","volume":"11581","author":"Fu","year":"2019","journal-title":"Lect. Notes Comput. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Duval, S., and Hashizume, H. (2006, January 23\u201325). Questions to improve quality of life with wearables: Humans, technology, and the world. Proceedings of the 2006 International Conference on Hybrid Information Technology, ICHIT, Daejeon, Korea.","DOI":"10.1109\/ICHIT.2006.253492"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Mardonova, M., and Choi, Y. (2018). Review of wearable device technology and its applications to the mining industry. Energies, 11.","DOI":"10.3390\/en11030547"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1108\/ITP-03-2017-0076","article-title":"Tapping into the wearable device revolution in the work environment: A systematic review","volume":"31","author":"Khakurel","year":"2018","journal-title":"Inf. Technol. People"},{"key":"ref_5","unstructured":"Sazonov, E. (2020). Introduction. Wearable Sensors: Fundamentals, Implementation and Applications, Academic Press."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2853","DOI":"10.1007\/s10845-018-1416-9","article-title":"Industrial wearable system: The human-centric empowering technology in Industry 4.0","volume":"30","author":"Kong","year":"2019","journal-title":"J. Intell. Manuf."},{"key":"ref_7","unstructured":"Mewara, D., Purohit, P., Pratap, B., and Rathore, S. (2016). Wearable Devices Applications & its Future. Int. J. Technol. Res. Eng., 59\u201364."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/j.tele.2016.09.001","article-title":"Domain-specific innovativeness and new product adoption: A case of wearable devices","volume":"34","author":"Jeong","year":"2017","journal-title":"Telemat. Inform."},{"key":"ref_9","first-page":"33","article-title":"The use of smart wearables in primary and secondary education: A systematic review","volume":"13","author":"Koutromanos","year":"2020","journal-title":"Themes eLearn."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.tele.2016.09.010","article-title":"The underlying factors of the perceived usefulness of using smart wearable devices for disaster applications","volume":"34","author":"Cheng","year":"2017","journal-title":"Telemat. Inform."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Chander, H., Burch, R.F., Talegaonkar, P., Saucier, D., Luczak, T., Ball, J.E., Turner, A., Kodithuwakku Arachchige, S.N.K., Carroll, W., and Smith, B.K. (2020). Wearable Stretch Sensors for Human Movement Monitoring and Fall Detection in Ergonomics. Int. J. Env. Res. Public Health, 17.","DOI":"10.3390\/ijerph17103554"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/j.comcom.2019.12.019","article-title":"Use of wearable devices to study activity of children in classroom; Case study\u2014Learning geometry using movement","volume":"150","author":"Prosen","year":"2020","journal-title":"Comput. Commun."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Conforti, I., Mileti, I., Del Prete, Z., and Palermo, E. (2020). Measuring Biomechanical Risk in Lifting Load Tasks Through Wearable System and Machine-Learning Approach. Sensors, 20.","DOI":"10.3390\/s20061557"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1007\/978-3-319-41962-6_39","article-title":"Towards Universal Design Criteria for Design of Wearables","volume":"Volume 500","author":"Tomberg","year":"2016","journal-title":"Advances in Intelligent Systems and Computing"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Niknejad, N., Ismail, W.B., Mardani, A., Liao, H., and Ghani, I. (2020). A comprehensive overview of smart wearables: The state of the art literature, recent advances, and future challenges. Eng. Appl. Artif. Intell., 90.","DOI":"10.1016\/j.engappai.2020.103529"},{"key":"ref_16","unstructured":"Sazonov, E. (2020). Wearables: Fundamentals, advancements, and a roadmap for the future. Wearable Sensors: Fundamentals, Implementation and Applications, Academic Press."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1007\/978-3-319-48511-9_6","article-title":"A Conceptual Design of Intelligent Shoes for Pregnant Women","volume":"Volume 413","author":"Dimou","year":"2017","journal-title":"Lecture Notes in Electrical Engineering"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2573","DOI":"10.1109\/COMST.2017.2731979","article-title":"A Survey of Wearable Devices and Challenges","volume":"19","author":"Seneviratne","year":"2017","journal-title":"IEEE Commun. Surv. Tutor."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1109\/THMS.2018.2878824","article-title":"Human work and status evaluation based on wearable sensors in human factors and ergonomics: A review","volume":"49","author":"Tsao","year":"2019","journal-title":"IEEE Trans. Hum. Mach. Syst."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"102937","DOI":"10.1016\/j.ergon.2020.102937","article-title":"A narrative review on contemporary and emerging uses of inertial sensing in occupational ergonomics","volume":"76","author":"Lim","year":"2020","journal-title":"Int. J. Ind. Ergon."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"4179","DOI":"10.1109\/LRA.2018.2864356","article-title":"ErgoTac: A Tactile Feedback Interface for Improving Human Ergonomics in Workplaces","volume":"3","author":"Kim","year":"2018","journal-title":"IEEE Robot. Autom. Lett."},{"key":"ref_22","unstructured":"International Organization for Standardization (2011). ISO 26800: Ergonomics\u2014General Approach, Principles and Concepts, ISO."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1080\/00140130400029167","article-title":"Ergonomics and human factors: The paradigms for science, engineering, design, technology and management of human-compatible systems","volume":"48","author":"Karwowski","year":"2005","journal-title":"Ergonomics"},{"key":"ref_24","unstructured":"Bridger, R.S. (2003). Introduction to Ergonomics, Routledge, Taylor & Francis Group."},{"key":"ref_25","unstructured":"International Organization for Standardization (2016). ISO 6385: Ergonomics Principles in the Design of Work Systems, ISO."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/S0003-6870(00)00034-X","article-title":"Fundamentals of ergonomics in theory and practice","volume":"31","author":"Wilson","year":"2000","journal-title":"Appl. Ergon."},{"key":"ref_27","unstructured":"Centre for Reviews and Dissemination Systematic Reviews (2009). CRD\u2019s Guidance for Undertaking Reviews in Health Care, CRD."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Higgins, J.P.T., Thomas, J., Chandler, J., Cumpston, M., Li, T., Page, M.J., and Welch, V.A. (2019). Cochrane Handbook for Systematic Reviews of Interventions, John Wiley & Sons. [2nd ed.].","DOI":"10.1002\/9781119536604"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Moher, D., Liberati, A., Tetzlaff, J., and Altman, D.G. (2009). The PRISMA Group Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. PLoS Med., 6.","DOI":"10.1371\/journal.pmed.1000097"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Rezende, A., Alves, C., Marques, I., Silva, M.A., and Naves, E. (2018). Polymer Optical Fiber Goniometer: A New Portable, Low Cost and Reliable Sensor for Joint Analysis. Sensors, 18.","DOI":"10.3390\/s18124293"},{"key":"ref_31","first-page":"285","article-title":"Application of wearable device to develop visual load intelligence monitoring and evaluation technology","volume":"Volume 818","author":"Bagnara","year":"2019","journal-title":"Advances in Intelligent Systems and Computing, Proceedings of the 20th Congress of the International Ergonomics Association (IEA 2018), Florence, Italy, 26\u201330 August 2018"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Sayegh, F., Fadhli, F., Karam, F., Boabbas, M., Mahmeed, F., Korbane, J.A., Alkork, S., and Beyrouthy, T. (September, January 30). A wearable rehabilitation device for paralysis. Proceedings of the BioSMART 2017 2nd International Conference on Bio-Engineering for Smart Technologies, Paris, France.","DOI":"10.1109\/BIOSMART.2017.8095334"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1177\/1555343417716040","article-title":"Measuring Mental Workload with Low-Cost and Wearable Sensors: Insights into the Accuracy, Obtrusiveness, and Research Usability of Three Instruments","volume":"11","author":"Lo","year":"2017","journal-title":"J. Cogn. Eng. Decis. Mak."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2056","DOI":"10.1017\/S0263574718001340","article-title":"A Novel Generation of Ergonomic Upper-Limb Wearable Robots: Design Challenges and Solutions","volume":"37","author":"Ercolini","year":"2019","journal-title":"Robotica"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Zhou, Y., David, B., and Chalon, R. (2012). PlayAllAround: Wearable one-hand gesture input and scalable projected interfaces. ERGO IHM, 105\u2013112.","DOI":"10.1145\/2652574.2653418"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Fusca, M., Negrini, F., Perego, P., Magoni, L., Molteni, F., and Andreoni, G. (2018). Validation of a Wearable IMU System for Gait Analysis: Protocol and Application to a New System. Appl. Sci., 8.","DOI":"10.3390\/app8071167"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ssci.2015.01.008","article-title":"Predictive models to assess Oxygen Deficiency Hazard (ODH): A systematic review","volume":"75","author":"Stefana","year":"2015","journal-title":"Saf. Sci."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Marciano, F., Mattogno, P.P., Codenotti, A., Cocca, P., Fontanella, M.M., and Doglietto, F. (2020). Work-related musculoskeletal disorders among endoscopic transsphenoidal surgeons: A systematic review of prevalence and ergonomic interventions. Int. J. Occup. Saf. Ergon., 1\u201310.","DOI":"10.1080\/10803548.2020.1774160"},{"key":"ref_39","first-page":"173","article-title":"A Human Postures Inertial Tracking System for Ergonomic Assessments","volume":"Volume 825","author":"Bagnara","year":"2019","journal-title":"Advances in Intelligent Systems and Computing, Proceedings of the 20th Congress of the International Ergonomics Association (IEA 2018), Florence, Italy, 26\u201330 August 2018"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1007\/978-3-319-94619-1_21","article-title":"Imu-based motion capture wearable system for ergonomic assessment in industrial environment","volume":"Volume 795","author":"Ahram","year":"2019","journal-title":"Advances in Human Factors in Wearable Technologies and Game Design"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1007\/978-3-319-73888-8_70","article-title":"Human posture tracking system for industrial process design and assessment","volume":"Volume 722","author":"Karwowski","year":"2018","journal-title":"Intelligent Human Systems Integration"},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Conforti, I., Mileti, I., Del Prete, Z., and Palermo, E. (2019, January 4\u20136). Assessing ergonomics and biomechanical risk in manual handling of loads through a wearable system. Proceedings of the 2019 IEEE International Workshop on Metrology for Industry 4.0 and IoT, MetroInd 4.0 and IoT, Naples, Italy.","DOI":"10.1109\/METROI4.2019.8792843"},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Peppoloni, L., Filippeschi, A., and Ruffaldi, E. (2014, January 16\u201319). Assessment of task ergonomics with an upper limb wearable device. Proceedings of the 2014 22nd Mediterranean Conference on Control and Automation, MED 2014, Palermo, Italy.","DOI":"10.1109\/MED.2014.6961394"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ergon.2015.07.002","article-title":"(WMSDs issue) A novel wearable system for the online assessment of risk for biomechanical load in repetitive efforts","volume":"52","author":"Peppoloni","year":"2016","journal-title":"Int. J. Ind. Ergon."},{"key":"ref_45","unstructured":"Kunze, K., Uema, Y., Tanaka, K., Kise, K., Ishimaru, S., and Inami, M. (2015, January 9\u201311). MEME\u2014Eye wear computing to explore human behavior. Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing and the Proceedings of the 2015 ACM International Symposium on Wearable Computers, Osaka, Japan."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/j.autcon.2018.10.004","article-title":"Wearable insole pressure system for automated detection and classification of awkward working postures in construction workers","volume":"96","author":"Li","year":"2018","journal-title":"Autom. Constr."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Antwi-Afari, M.F., Li, H., Umer, W., Yu, Y., and Xing, X. (2020). Construction Activity Recognition and Ergonomic Risk Assessment Using a Wearable Insole Pressure System. J. Constr. Eng. Manag., 146.","DOI":"10.1061\/(ASCE)CO.1943-7862.0001849"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"107583","DOI":"10.1109\/ACCESS.2020.3000673","article-title":"Smart Vest for Real-Time Postural Biofeedback and Ergonomic Risk Assessment","volume":"8","author":"Cerqueira","year":"2020","journal-title":"IEEE Access"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Conforti, I., Mileti, I., Panariello, D., Caporaso, T., Grazioso, S., Del Prete, Z., Lanzotti, A., Di Gironimo, G., and Palermo, E. (2020, January 4\u20136). Validation of a novel wearable solution for measuring L5\/S1 load during manual material handling tasks. Proceedings of the 2020 IEEE International Workshop on Metrology for Industry 4.0 and IoT, MetroInd 4.0 and IoT 2020, Naples, Italy.","DOI":"10.1109\/MetroInd4.0IoT48571.2020.9138259"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Doshi, M., Shah, H., Gada, H., and Shah, M. (2018, January 14\u201315). Wearable DAQ (Data Acquisition System) for Measurement of R.U.L.A. (Rapid Upper Limb Assessment) Rating of Vehicles. Proceedings of the 2nd International Conference on Intelligent Computing and Control Systems, ICICCS 2018, Madurai, India.","DOI":"10.1109\/ICCONS.2018.8663119"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Ferreira, E.C., Beingolea, J.R., and Rendulich, J.E. (2019, January 26\u201329). Wearable and IoT technology in the development of applications for Postural Physiotherapy. Proceedings of the 2019 IEEE 1st Sustainable Cities Latin America Conference, SCLA 2019, Arequipa, Peru.","DOI":"10.1109\/SCLA.2019.8905667"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Giannini, P., Bassani, G., Avizzano, C.A., and Filippeschi, A. (2020). Wearable sensor network for biomechanical overload assessment in manual material handling. Sensors, 20.","DOI":"10.3390\/s20143877"},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Hahm, K.S., and Asada, H.H. (2019, January 4\u20138). Design of a Fail-Safe Wearable Robot with Novel Extendable Arms for Ergonomic Accommodation during Floor Work. Proceedings of the IEEE International Conference on Intelligent Robots and Systems, Macau, China.","DOI":"10.1109\/IROS40897.2019.8967956"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.apergo.2018.11.009","article-title":"A comparison of biomechanical workload between smartphone and smartwatch while sitting and standing","volume":"76","author":"Jin","year":"2019","journal-title":"Appl. Ergon."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Lenzi, S.E., Standoli, C.E., Andreoni, G., Perego, P., and Lopomo, N.F. (2018, January 22\u201326). Comparison among standard method, dedicated toolbox and kinematic-based approach in assessing risk of developing upper limb musculoskeletal disorders. Proceedings of the International Conference on Applied Human Factors and Ergonomics, Orlando, FL, USA.","DOI":"10.1007\/978-3-319-94619-1_13"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Lins, C., Fudickar, S., Gerka, A., and Hein, A. (2018, January 22\u201323). A wearable vibrotactile interface for unfavorable posture awareness warning. Proceedings of the 4th International Conference on Information and Communication Technologies for Ageing Well and e-Health, Funchal, Portugal.","DOI":"10.5220\/0006734901780183"},{"key":"ref_57","first-page":"194","article-title":"Development of a Wearable IMU System for Automatically Assessing Lifting Risk Factors","volume":"Volume 12198","author":"Lu","year":"2020","journal-title":"Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)"},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Manjarres, J., Narvaez, P., Gasser, K., Percybrooks, W., and Pardo, M. (2020). Physical workload tracking using human activity recognition with wearable devices. Sensors, 20.","DOI":"10.3390\/s20010039"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1001\/jamasurg.2019.6384","article-title":"Measuring Ergonomic Risk in Operating Surgeons by Using Wearable Technology","volume":"155","author":"Meltzer","year":"2020","journal-title":"JAMA Surg."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1016\/j.aei.2018.08.020","article-title":"Automated ergonomic risk monitoring using body-mounted sensors and machine learning","volume":"38","author":"Nath","year":"2018","journal-title":"Adv. Eng. Inform."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.apergo.2017.02.007","article-title":"Ergonomic analysis of construction worker\u2019s body postures using wearable mobile sensors","volume":"62","author":"Nath","year":"2017","journal-title":"Appl. Ergon."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.apergo.2017.02.001","article-title":"A data-driven approach to modeling physical fatigue in the workplace using wearable sensors","volume":"65","author":"Cavuoto","year":"2017","journal-title":"Appl. Ergon."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.autcon.2017.08.001","article-title":"Analysis of construction trade worker body motions using a wearable and wireless motion sensor network","volume":"83","author":"Valero","year":"2017","journal-title":"Autom. Constr."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.autcon.2016.11.007","article-title":"Wearable IMU-based real-time motion warning system for construction workers\u2032 musculoskeletal disorders prevention","volume":"74","author":"Yan","year":"2017","journal-title":"Autom. Constr."},{"key":"ref_65","unstructured":"International Organization for Standardization (2000). ISO 11226: Ergonomics\u2014Evaluation of Static Working Postures, ISO."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/0003-6870(93)90080-S","article-title":"RULA: A survey method for the investigation of work-related upper limb disorders","volume":"24","author":"McAtamney","year":"1993","journal-title":"Appl. Ergon."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1080\/15428119591016863","article-title":"The strain index: A proposed method to analyze jobs for risk of distal upper extremity disorders","volume":"56","author":"Moore","year":"1995","journal-title":"Am. Ind. Hyg. Assoc. J."},{"key":"ref_68","unstructured":"International Organization for Standardization (2007). ISO 11228-3: Ergonomics\u2014Manual Handling\u2014Part 3: Handling of Low Loads at High Frequency, ISO."},{"key":"ref_69","unstructured":"Waters, T.R., Putz-Anderson, V., and Garg, A. (1994). NIOSH 94-110: Applications Manual for the Revised NIOSH Lifting Equation."},{"key":"ref_70","unstructured":"International Organization for Standardization (2003). ISO 11228-1: Ergonomics\u2014Manual Handling\u2014Part. 1: Lifting and Carrying, ISO."},{"key":"ref_71","first-page":"21","article-title":"Assessment of biomechanical risk at work: Practical approaches and tools","volume":"10","author":"Cocca","year":"2008","journal-title":"Acta Bioeng. Biomech."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1093\/occmed\/kqi082","article-title":"Ergonomic methods for assessing exposure to risk factors for work-related musculoskeletal disorders","volume":"55","author":"David","year":"2005","journal-title":"Occup. Med."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.apergo.2015.11.020","article-title":"Musculoskeletal disorders in construction: A review and a novel system for activity tracking with body area network","volume":"54","author":"Valero","year":"2016","journal-title":"Appl. Ergon."},{"key":"ref_74","unstructured":"De Kok, J., Vroonhof, P., Snijders, J., Roullis, G., Clarke, M., Peereboom, K., van Dorst, P., and Isusi, I. (2019). Work-Related Musculoskeletal Disorders: Prevalence, Costs and Demographics in the EU, European Agency for Safety and Health at Work."},{"key":"ref_75","first-page":"1348","article-title":"Ergonomics and Standard","volume":"Volume 824","author":"Bagnara","year":"2019","journal-title":"Proceedings of the 20th Congress of the International Ergonomics Association (IEA 2018). IEA 2018. Advances in Intelligent Systems and Computing"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/j.ergon.2013.04.009","article-title":"A multi-criteria ergonomic and performance methodology for evaluating alternatives in \u201cmanuable\u201d material handling","volume":"43","author":"Rossi","year":"2013","journal-title":"Int. J. Ind. Ergon."},{"key":"ref_77","doi-asserted-by":"crossref","unstructured":"Lee, W., Lin, J.-H., Bao, S., and Lin, K.-Y. (2019, January 17\u201319). Reliability and Validity of a Posture Matching Method Using Inertial Measurement Unit-Based Motion Tracking System for Construction Jobs. Proceedings of the ASCE International Conference on Computing in Civil Engineering 2019, Atlanta, Georgia.","DOI":"10.1061\/9780784482438.074"},{"key":"ref_78","doi-asserted-by":"crossref","unstructured":"Palikhe, S., Yirong, M., Choi, B.Y., and Lee, D.E. (2020). Analysis of musculoskeletal disorders and muscle stresses on construction workers\u2032 awkward postures using simulation. Sustainability, 12.","DOI":"10.3390\/su12145693"},{"key":"ref_79","doi-asserted-by":"crossref","unstructured":"Stefana, E., Marciano, F., Cocca, P., Rossi, D., and Tomasoni, G. (2019). Oxygen deficiency hazard in confined spaces in the steel industry: Assessment through predictive models. Int. J. Occup. Saf. Ergon.","DOI":"10.1080\/10803548.2019.1669954"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/3\/777\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:14:45Z","timestamp":1760159685000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/3\/777"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,24]]},"references-count":79,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2021,2]]}},"alternative-id":["s21030777"],"URL":"https:\/\/doi.org\/10.3390\/s21030777","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,24]]}}}