{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T20:41:16Z","timestamp":1785271276371,"version":"3.55.0"},"reference-count":33,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2021,2,12]],"date-time":"2021-02-12T00:00:00Z","timestamp":1613088000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A single crystal chemical vapor deposition (scCVD) diamond membrane-based microdosimetric system was used to perform simultaneous measurements of dose profile and microdosimetric spectra with the Y1 proton passive scattering beamline of the Center of Proton Therapy, Institute Curie in Orsay, France. To qualify the performance of the set-up in clinical conditions of hadrontherapy, the dose, dose rate and energy loss pulse-height spectra in a diamond microdosimeter were recorded at multiple points along depth of a water-equivalent plastic phantom. The dose-mean lineal energy (y\u00afD) values were computed from experimental data and compared to silicon on insulator (SOI) microdosimeter literature results. In addition, the measured dose profile, pulse height spectra and y\u00afD values were benchmarked with a numerical simulation using TOPAS and Geant4 toolkits. These first clinical tests of a novel system confirm that diamond is a promising candidate for a tissue equivalent, radiation hard, high spatial resolution microdosimeter in beam quality assurance of proton therapy.<\/jats:p>","DOI":"10.3390\/s21041314","type":"journal-article","created":{"date-parts":[[2021,2,12]],"date-time":"2021-02-12T18:45:00Z","timestamp":1613155500000},"page":"1314","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Simultaneous Measurements of Dose and Microdosimetric Spectra in a Clinical Proton Beam Using a scCVD Diamond Membrane Microdosimeter"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3683-351X","authenticated-orcid":false,"given":"Oluwasayo","family":"Loto","sequence":"first","affiliation":[{"name":"Universit\u00e9 Paris-Saclay, CEA, List, F-91120 Palaiseau, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Izabella","family":"Zahradnik","sequence":"additional","affiliation":[{"name":"Universit\u00e9 Paris-Saclay, CEA, List, F-91120 Palaiseau, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2389-3078","authenticated-orcid":false,"given":"Amelia Maia","family":"Leite","sequence":"additional","affiliation":[{"name":"Institut Curie, Radiation Oncology Department, PSL Research University, Proton Therapy Centre, Centre Universitaire, 91898 Orsay, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8577-2381","authenticated-orcid":false,"given":"Ludovic","family":"De Marzi","sequence":"additional","affiliation":[{"name":"Institut Curie, Radiation Oncology Department, PSL Research University, Proton Therapy Centre, Centre Universitaire, 91898 Orsay, France"},{"name":"Institut Curie, PSL Research University, University Paris Saclay, LITO, Inserm, 91898 Orsay, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominique","family":"Tromson","sequence":"additional","affiliation":[{"name":"Universit\u00e9 Paris-Saclay, CEA, List, F-91120 Palaiseau, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michal","family":"Pomorski","sequence":"additional","affiliation":[{"name":"Universit\u00e9 Paris-Saclay, CEA, List, F-91120 Palaiseau, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,2,12]]},"reference":[{"key":"ref_1","first-page":"142","article-title":"Particle therapy in Europe","volume":"10","author":"Grau","year":"2020","journal-title":"Molecular Oncol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ijrobp.2009.08.075","article-title":"Quantitative analyses of normal tissue effects in the clinic","volume":"10","author":"Marks","year":"2010","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"617","DOI":"10.3390\/cancers7020617","article-title":"Predictive risk of radiation induced cerebral necrosis in pediatric brain cancer patients after VMAT versus proton therapy","volume":"7","author":"Freund","year":"2015","journal-title":"Cancers"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"S230","DOI":"10.1016\/j.ijrobp.2019.06.329","article-title":"Brain Necrosis in Adult Proton Therapy Patients. Do Necrotic Regions Have Elevated Linear Energy Transfer?","volume":"105","author":"Schuemann","year":"2019","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.ijrobp.2016.08.001","article-title":"Humbling advances in technology: Protons, brainstem necrosis, and the self-driving car","volume":"97","author":"MacDonald","year":"2017","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_6","unstructured":"Zaider, M., Rossi, B.H.H., and Zaider, M. (1996). Microdosimetry and Its Applications, Springer. [1st ed.]."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1016\/j.ijrobp.2014.11.021","article-title":"Relating proton treatments to photon treatments via the relative biological effectiveness\u2014Should we revise current clinical practice?","volume":"91","author":"Paganetti","year":"2015","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"3407","DOI":"10.1109\/TNS.2008.2006894","article-title":"Tissue Equivalence Correction in Silicon Microdosimetry for Protons Characteristic of the LEO Space Environment","volume":"55","author":"Guatelli","year":"2008","journal-title":"IEEE Trans. Nuclear Sci."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"023505","DOI":"10.1063\/1.4926962","article-title":"Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy","volume":"107","author":"Guardiola","year":"2015","journal-title":"Appl. Phys. Lett."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.1109\/23.872983","article-title":"A new silicon detector for microdosimetry applications in proton therapy","volume":"47","author":"Rosenfeld","year":"2000","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1016\/S0168-583X(01)01316-7","article-title":"Ion beam induced charge characterisation of a silicon microdosimeter using a heavy ion microprobe","volume":"190","author":"Cornelius","year":"2002","journal-title":"Nucl. Inst. Methods Phys.s Res."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"S36","DOI":"10.1016\/S0167-8140(15)34093-7","article-title":"First investigations of Ultra-Thin 3D silicon detectors as microdosimeters","volume":"110","author":"Fleta","year":"2014","journal-title":"Radiother. Oncol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1109\/TNS.2019.2939355","article-title":"SOI Thin Microdosimeters for High LET Single-Event Upset Studies in Fe, O, Xe, and Cocktail Ion Beam Fields","volume":"67","author":"James","year":"2019","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.ejmp.2019.06.011","article-title":"Microdosimetry at the CATANA 62 MeV proton beam with a sealed miniaturized TEPC","volume":"64","author":"Conte","year":"2019","journal-title":"Phys. Med."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"108730","DOI":"10.1016\/j.radphyschem.2020.108730","article-title":"Microdosimetry with a sealed mini-TEPC and a silicon telescope at a clinical proton SOBP of CATANA","volume":"171","author":"Bianchi","year":"2020","journal-title":"Radiat. Phys. Chem."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2409","DOI":"10.1109\/TNS.2012.2209677","article-title":"A novel microdosimeter based upon artificial single crystal diamond","volume":"59","author":"Rollet","year":"2012","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_17","unstructured":"Magrin, G. (2018). Microdosimetry in ion-beam therapy: Studying and comparing outcomes from different detectors. arXiv."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.radmeas.2018.02.001","article-title":"Toward the use of single crystal diamond based detector for ion-beam therapy microdosimetry","volume":"110","author":"Verona","year":"2018","journal-title":"Radiat. Meas."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/S0168-9002(00)00882-2","article-title":"CVD diamond microdosimeters","volume":"458","author":"Manfredotti","year":"2001","journal-title":"Nucl. Inst. Methods in Phys. Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1800383","DOI":"10.1002\/pssa.201800383","article-title":"scCVD diamond membrane based microdosimeter for hadron therapy","volume":"215","author":"Zahradnik","year":"2018","journal-title":"Phys. Status Solidi"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"054102","DOI":"10.1063\/5.0002403","article-title":"A diamond guard ring microdosimeter for ion beam therapy","volume":"91","author":"Zahradnik","year":"2020","journal-title":"Rev Sci Inst"},{"key":"ref_22","unstructured":"(2020, October 09). Available online: https:\/\/www.labzy.com\/products\/nanomcaii\/."},{"key":"ref_23","unstructured":"(2020, October 09). Available online: https:\/\/www.iba-dosimetry.\/com\/."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/S0168-9002(03)01368-8","article-title":"GEANT4\u2014A simulation toolkit","volume":"506","author":"Agostinelli","year":"2003","journal-title":"Nucl. Inst. Meth. A"},{"key":"ref_25","unstructured":"Davis, J.A. (2015). Diamond Microdosimetry for Radioprotection Applications in Space. [Doctoral Thesis, University of Wollongong]."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"045014","DOI":"10.1088\/1361-6560\/ab586a","article-title":"Validation of Geant4 for silicon microdosimetry in heavy ion therapy","volume":"65","author":"Bolst","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"6085","DOI":"10.1002\/mp.12563","article-title":"Characterization of proton pencil beam scanning and passive beam using a high spatial resolution solid-state microdosimeter","volume":"44","author":"Tran","year":"2017","journal-title":"Med. Phys."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"6029","DOI":"10.1002\/mp.12583","article-title":"Microdosimetric measurements of a clinical proton beam with micrometer-sized solid-state detector","volume":"44","author":"Anderson","year":"2017","journal-title":"Med. Phys."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"235007","DOI":"10.1088\/1361-6560\/aaec2f","article-title":"SOI microdosimetry and modified MKM for evaluation of relative biological effectiveness for a passive proton therapy radiation field","volume":"63","author":"Debrot","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"6234","DOI":"10.1118\/1.4932217","article-title":"Analysis of the track-and dose-averaged LET and LET spectra in proton therapy using the geant4 Monte Carlo code","volume":"42","author":"Guan","year":"2015","journal-title":"Med. Phys."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"6818","DOI":"10.1118\/1.4758060","article-title":"TOPAS: An innovative proton Monte Carlo platform for research and clinical applications","volume":"39","author":"Perl","year":"2012","journal-title":"Med. Phys."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2645","DOI":"10.1088\/0031-9155\/60\/7\/2645","article-title":"A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams","volume":"60","author":"Carabe","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"N283","DOI":"10.1088\/0031-9155\/60\/14\/N283","article-title":"Comparison of linear energy transfer scoring techniques in Monte Carlo simulations of proton beams","volume":"60","author":"Granville","year":"2015","journal-title":"Phys. Med. Biol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/4\/1314\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:23:17Z","timestamp":1760160197000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/4\/1314"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,12]]},"references-count":33,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2021,2]]}},"alternative-id":["s21041314"],"URL":"https:\/\/doi.org\/10.3390\/s21041314","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,12]]}}}