{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T01:49:38Z","timestamp":1760233778004,"version":"build-2065373602"},"reference-count":27,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2021,2,21]],"date-time":"2021-02-21T00:00:00Z","timestamp":1613865600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"ZIM","award":["ZF4746801BA9"],"award-info":[{"award-number":["ZF4746801BA9"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Conventional pathogenic bacteria-detection methods are lab-bound, time-consuming and need trained personnel. Microelectrodes can be used to recognize harmful microorganisms by dielectric impedance spectroscopy. However, crucial for this spectroscopy method are the spatial dimensions and layout of the electrodes, as the corresponding distribution of the electric field defines the sensor system parameters such as sensitivity, SNR, and dynamic range. Therefore, a variety of sensor models are created and evaluated. FEM simulations in 2D and 3D are conducted for this impedimetric sensor. The authors tested differently shaped structures, verified the linear influence of the excitation amplitude and developed a mathematical concept for a quality factor that practically allows us to distinguish arbitrary sensor designs and layouts. The effect of guard electrodes blocking outer influences on the electric field are investigated, and essential configurations are explored. The results lead to optimized electronic sensors in terms of geometrical dimensions. Possible material choices for real sensors as well as design and layout recommendations are presented.<\/jats:p>","DOI":"10.3390\/s21041487","type":"journal-article","created":{"date-parts":[[2021,2,21]],"date-time":"2021-02-21T22:04:15Z","timestamp":1613945055000},"page":"1487","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Towards Easy-to-Use Bacteria Sensing: Modeling and Simulation of a New Environmental Impedimetric Biosensor in Fluids"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8583-0921","authenticated-orcid":false,"given":"Christian","family":"Pfeffer","sequence":"first","affiliation":[{"name":"Department of Electrical and Computer Engineering, Technical University of Munich, 80333 Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yue","family":"Liang","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, Technical University of Munich, 80333 Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helmut","family":"Grothe","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, Technical University of Munich, 80333 Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernhard","family":"Wolf","sequence":"additional","affiliation":[{"name":"Steinbeistransferzentrum f\u00fcr Medizinische Elektronik und Lab-on-Chip Systeme, 80802 Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8118-757X","authenticated-orcid":false,"given":"Ralf","family":"Brederlow","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, Technical University of Munich, 80333 Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,2,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.jcma.2017.07.012","article-title":"Bacterial biofilm and associated infections","volume":"81","author":"Jamal","year":"2018","journal-title":"J. Chin. Med. Assoc."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/S0956-5663(99)00039-1","article-title":"Biosensors for detection of pathogenic bacteria","volume":"14","author":"Ivnitski","year":"1999","journal-title":"Biosens. Bioelectron."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"4483","DOI":"10.3390\/s90604483","article-title":"An overview of recent strategies in pathogen sensing","volume":"9","author":"Heo","year":"2009","journal-title":"Sensors"},{"key":"ref_4","first-page":"14","article-title":"Mikrosensor-System zur Bestimmung des Kontaminationsgrades von Oberfl\u00e4chen","volume":"1","year":"2004","journal-title":"Abschlussbericht Mikrobe F\u00f6Rderkennzeichen 16SV1117\/9"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1002\/elps.201900286","article-title":"Spatially resolved electrical impedance methods for cell and particle characterization","volume":"41","author":"Schwarz","year":"2020","journal-title":"Electrophoresis"},{"key":"ref_6","first-page":"332","article-title":"Optimisation of Bacteria Sensitive Sensor","volume":"Volume 1","author":"Weyh","year":"2002","journal-title":"IFMBE Proceedings"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1007\/s10126-013-9495-2","article-title":"Attachment and detachment of living microorganisms using a potential-controlled electrode","volume":"15","author":"Koyama","year":"2013","journal-title":"Mar. Biotechnol."},{"key":"ref_8","first-page":"105534","article-title":"Attachment of Leptospirillum sp. to chemically modified pyrite surfaces. Fast and simple electrochemical monitoring of bacterial-mineral interactions","volume":"1999","author":"Saavedra","year":"2020","journal-title":"Hydrometallurgy"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1007\/s10126-015-9651-y","article-title":"Electrical retrieval of living microorganisms from cryopreserved marine sponges using a potential-controlled electrode","volume":"17","author":"Koyama","year":"2015","journal-title":"Mar. Biotechnol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"358","DOI":"10.5796\/electrochemistry.84.358","article-title":"Electrical Collection of Membrane-intact and Dehydrogenase-positive Symbiotic Bacteria from the Deep-sea Bivalve Calyptogena Okutanii","volume":"84","author":"Koyama","year":"2016","journal-title":"Electrochemistry"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"112214","DOI":"10.1016\/j.bios.2020.112214","article-title":"Electrochemical biosensors for pathogen detection","volume":"159","author":"Cesewski","year":"2020","journal-title":"Biosens. Bioelectron."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1039\/b109895k","article-title":"Detection of infectious and toxigenic bacteria","volume":"127","author":"Deisingh","year":"2002","journal-title":"Analyst"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.snb.2007.03.043","article-title":"On-chip microfluidic biosensor for bacterial detection and identification","volume":"126","author":"Boehm","year":"2007","journal-title":"Sens. Actuators B Chem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1478","DOI":"10.1039\/b801929k","article-title":"Cell characterization using a protein-functionalized pore","volume":"8","author":"Carbonaro","year":"2008","journal-title":"Lab Chip"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/j.bios.2016.06.053","article-title":"A Nanostructured Bifunctional platform for Sensing of Glucose Biomarker in Artificial Saliva: Synergy in hybrid Pt\/Au surfaces","volume":"86","author":"Shimizu","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1039\/B705082H","article-title":"Cell detection and counting through cell lysate impedance spectroscopy in microfluidic devices","volume":"7","author":"Cheng","year":"2007","journal-title":"Lab Chip"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1128\/JCM.44.2.561-570.2006","article-title":"Use of electrochemical DNA biosensors for rapid molecular identification of uropathogens in clinical urine specimens","volume":"44","author":"Liao","year":"2006","journal-title":"J. Clin. Microbiol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"7239","DOI":"10.1021\/ac800643k","article-title":"Detection of Escherichia coli and Salmonella typhimurium using interdigitated microelectrode capacitive immunosensors: The importance of transducer geometry","volume":"80","author":"Laczka","year":"2008","journal-title":"Anal. Chem."},{"key":"ref_19","unstructured":"Yao, L., Hajj-Hassan, M., Ghafar-Zadeh, E., Shabani, A., Chodavarapu, V., and Zourob, M. (2008, January 4\u20137). CMOS capactive sensor system for bacteria detection using phage organisms. Proceedings of the 2008 Canadian Conference on Electrical and Computer Engineering, Niagara Falls, ON, Canada."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1016\/j.bios.2003.10.009","article-title":"Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium","volume":"19","author":"Yang","year":"2004","journal-title":"Biosens. Bioelectron."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1002\/cbic.200400337","article-title":"Immuno-carbon nanotubes and recognition of pathogens","volume":"6","author":"Elkin","year":"2005","journal-title":"ChemBioChem"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1166\/jnn.2006.130","article-title":"Carbon nanotubes for immunomagnetic separation of Escherichia coli O157: H7","volume":"6","author":"Lin","year":"2006","journal-title":"J. Nanosci. Nanotechnol."},{"key":"ref_23","first-page":"3133","article-title":"Microelectrical noise detector for rapid, specific, and sensitive identification of bacteria","volume":"24","author":"Seo","year":"2006","journal-title":"J. Vac. Sci. Technol. B Microelectron. Nanometer Struct. Process. Meas. Phenom."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2908","DOI":"10.1364\/BOE.6.002908","article-title":"Selective detection of bacteria in urine with a long-range surface plasmon waveguide biosensor","volume":"6","author":"Krupin","year":"2015","journal-title":"Biomed. Opt. Express"},{"key":"ref_25","unstructured":"Olmo, A., and Y\u00fafera, A. (2010, January 20\u201323). Computer Simulation of Microelectrode based Bio-Impedance Measurements with COMSOL. Proceedings of the Biodevices, Valencia, Spain."},{"key":"ref_26","unstructured":"COMSOL, C.M (2021, February 21). AC\/DC Module User\u2019s Guide COMSOL Multiphysics\u00aev. 5.5. COMSOL. COMSOL Multiphysics\u00ae v. 5.5. COMSOL AB, Available online: https:\/\/www.comsol.com\/."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Adamczyk, Z. (2013). Diffusion of Particles. Encyclopedia of Colloid and Interface Science, Springer.","DOI":"10.1007\/978-3-642-20665-8_175"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/4\/1487\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:27:27Z","timestamp":1760160447000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/4\/1487"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,21]]},"references-count":27,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2021,2]]}},"alternative-id":["s21041487"],"URL":"https:\/\/doi.org\/10.3390\/s21041487","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2021,2,21]]}}}