{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T12:45:44Z","timestamp":1789476344501,"version":"build-2803163510"},"reference-count":34,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2021,2,25]],"date-time":"2021-02-25T00:00:00Z","timestamp":1614211200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["11527801,20222201 and 61305026"],"award-info":[{"award-number":["11527801,20222201 and 61305026"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002888","name":"Beijing Municipal Commission of Education","doi-asserted-by":"publisher","award":["KM200710005009, PXM2009_014204_09_000154 and KM201310005006"],"award-info":[{"award-number":["KM200710005009, PXM2009_014204_09_000154 and KM201310005006"]}],"id":[{"id":"10.13039\/501100002888","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this paper, the key technology of interferometric microwave thermometer is studied, the research can be applied to the temperature measurement of human body and subcutaneous tissue. This paper proposes a hardware architecture of interferometric microwave thermometer with 2 GHz bandwidth, in which the phase shifter is used to correct phase error and the quadrature demodulator is used to realize autocorrelation detection function. The results show that when input power is 7 dBm, the detection sensitivity can reach 176.54 mV\/dBm and the temperature resolution of the microwave radiometer can reach 0.4 K. Correction algorithm is designed to improve the accuracy of temperature measurement. After correction, the phase error is reduced from 40\u00b0 to 1.4\u00b0 and when temperature changes 0.1 \u00b0C, the voltage value changes obviously. Step-by-step calibration and overall calibration are used to calibrate the device. Inversion algorithm can determine the relationship between physical temperature and output voltage. The mean square error of water temperature inversion by multiple linear regression algorithm is 0.607 and that of BP neural network algorithm is 0.334. The inversion accuracy can be improved by reducing the temperature range. Our work provides a promising realization of accurate, rapid and non-contact detection device of human body temperature.<\/jats:p>","DOI":"10.3390\/s21051619","type":"journal-article","created":{"date-parts":[[2021,2,26]],"date-time":"2021-02-26T04:36:24Z","timestamp":1614314184000},"page":"1619","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Design and Implementation of a Novel Interferometric Microwave Radiometer for Human Body Temperature Measurement"],"prefix":"10.3390","volume":"21","author":[{"given":"Guangmin","family":"Sun","sequence":"first","affiliation":[{"name":"Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pan","family":"Ma","sequence":"additional","affiliation":[{"name":"Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1155-4450","authenticated-orcid":false,"given":"Jie","family":"Liu","sequence":"additional","affiliation":[{"name":"Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8224-2764","authenticated-orcid":false,"given":"Chong","family":"Shi","sequence":"additional","affiliation":[{"name":"Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingyan","family":"Ma","sequence":"additional","affiliation":[{"name":"Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li","family":"Peng","sequence":"additional","affiliation":[{"name":"Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,2,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Bonds, Q., Weller, T., and Roeder, B. (2009, January 20\u201321). A total power radiometer (TPR) and measurement test bed for non-contact biomedical sensing applications. Proceedings of the 2009 IEEE 10th Annual Wireless and Microwave Technology Conference, Clearwater, FL, USA.","DOI":"10.1109\/WAMICON.2009.5207244"},{"key":"ref_2","unstructured":"Bonds, Q. (2010). A Microwave Radiometer for Close Proximity Core Body Temperature Monitoring: Design, Development, and Experimentation, University of South Florida."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Bonds, Q., Weller, T., and Roeder, B. (2009, January 9\u201311). A tunable Cavity Backed Slot Antenna (CBSA) for close proximity biomedical sensing applications. Proceedings of the 2009 IEEE International Conference on Microwaves, Communications, Antennas and Electronics Systems, Tel Aviv, Israel.","DOI":"10.1109\/COMCAS.2009.5385960"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1109\/JSEN.2011.2113332","article-title":"Towards core body temperature measurement via close proximity radiometric sensing","volume":"12","author":"Bonds","year":"2012","journal-title":"IEEE Sens. J."},{"key":"ref_5","unstructured":"Pi, Z. (2015). Research on Microwave Radiometer Antenna for Human Body Temperature Measurement, Huazhong University of Science and Technology."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Park, W., and Jeong, J. (2017). Total Power Radiometer for Medical Sensor Applications Using Matched and Mismatched Noise Sources. Sensors, 17.","DOI":"10.3390\/s17092105"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Kashif, M., Hu, A., and Miao, J. (2016, January 12\u201316). Design and Implementation of an Analog Complex Correlator for Passive Millimeter Wave Imaging System. Proceedings of the International Bhurban Conference on Applied Sciences & Technology, Islamabad, Pakistan.","DOI":"10.1109\/IBCAST.2016.7429941"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2997","DOI":"10.1109\/TIM.2017.2714501","article-title":"A Compact Analog Complex Cross-Correlator for Passive Millimeter-Wave Imager","volume":"66","author":"Wang","year":"2017","journal-title":"IEEE Trans. Instrum. Meas. J."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Wang, C., and Ye, X. (2018, January 1\u20134). A 3.5\u20138 GHz Analog Complex Cross-correlator for Interferometric Passive Millimeter-wave Security Imaging Systems. Proceedings of the 2018 Progress In Electromagnetics Research Symposium (PIERS-Toyama), Toyama, Japan.","DOI":"10.23919\/PIERS.2018.8597723"},{"key":"ref_10","first-page":"608","article-title":"Brief introduction of calibration method for fully polarized microwave radiometer","volume":"S1","author":"Shi","year":"2014","journal-title":"J. Microw. Sci."},{"key":"ref_11","unstructured":"He, F. (2015). Research on Inversion Method of Microwave Nondestructive Measurement of Human Body Internal Temperature, Huazhong University of Science and Technology."},{"key":"ref_12","first-page":"185","article-title":"Study on a variable temperature calibration source for Microwave Radiometer Based on polarization grid","volume":"46","author":"Dong","year":"2018","journal-title":"Acta Electron. Sin. J."},{"key":"ref_13","first-page":"45","article-title":"Study on the principle of periodic two-point calibration microwave radiometer","volume":"36","author":"Li","year":"2006","journal-title":"Electromagn. Field Microw."},{"key":"ref_14","unstructured":"Scheeler, R.P. (2013). A Microwave Radiometer for Internal Body Temperature Measurement, University of Colorado at Boulder."},{"key":"ref_15","unstructured":"Gu, Z. (2004). Study on Radiation Characteristics of Millimeter Wave Stealth Coating, Nanjing University of technology."},{"key":"ref_16","unstructured":"Ying, G., Zhou, C., and Chen, H. (1992). Microwave Radiometer, Ocean Press."},{"key":"ref_17","unstructured":"Wu, Q., Qu, D., and Qin, Y. (2010). Millimeter Wave Medical Technology and Its Clinical Application, China Science and Technology Press."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Jeong, J., Park, K., and Lee, C. (2019). Design of Cavity-Backed Bow-Tie Antenna with Matching Layer for Human Body Application. Sensors, 19.","DOI":"10.3390\/s19184015"},{"key":"ref_19","first-page":"2489","article-title":"Real time elimination of analog correlation bias using vector modulator","volume":"44","author":"Xin","year":"2018","journal-title":"J. Beijing Univ. Aeronaut. Astronaut."},{"key":"ref_20","first-page":"105","article-title":"Fast inversion algorithm of magnetic nano temperature based on Gaussian Newton method","volume":"46","author":"Li","year":"2018","journal-title":"J. Huazhong Univ. Sci. Technol."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Wang, C., Xin, X., Liang, B., Li, Z., and Miao, J. (2018). Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications. Sensors, 18.","DOI":"10.3390\/s18020677"},{"key":"ref_22","first-page":"012010","article-title":"Development of the RF Front-end of a Multi-Channel Microwave Radiometer for Internal Body Temperature Measurements","volume":"637","author":"Karabetsos","year":"2015","journal-title":"J. Physics: Conf. Ser."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1023\/A:1015284304784","article-title":"Thermal near field and the possibilities of its use for in-depth temperature diagnostics of media","volume":"45","author":"Vaks","year":"2002","journal-title":"Radiophys. Quantum Electron."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1109\/MCOM.2014.6917412","article-title":"Toward wearable wireless thermometers for internal body temperature measurements","volume":"52","author":"Popovic","year":"2014","journal-title":"IEEE Commun. Mag."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1007\/s13131-020-1540-1","article-title":"Research on sea surface temperature retrieval by the one-dimensional synthetic aperture microwave radiometer, 1D-SAMR","volume":"39","author":"Ai","year":"2020","journal-title":"Acta Oceanol. Sin."},{"key":"ref_26","unstructured":"Zhang, Z. (2019). Microwave Radiometer Front-End and Its Wide-IF Super-Heterodyne Model and Application, School of Electronic Science and Engineering."},{"key":"ref_27","unstructured":"Chen, Q. (2016). Research on Key Technologies of the Frontend of W-Band Focal Plane Array Passive Imaging System, School of Electronic Engineering."},{"key":"ref_28","first-page":"8","article-title":"Sensitivity analysis of a periodically calibrated Dicke radiometer","volume":"32","author":"Xie","year":"2009","journal-title":"Electron. Meas. Technol."},{"key":"ref_29","unstructured":"Wang, B. (2013). Research on the Calibration and Error Analysis of AC Radiometer System, Huazhong University of Science and Technology."},{"key":"ref_30","unstructured":"Li, X. (2018). Research on Temperature Control of Blackbody Emitter Based on PID Algorithm of Neural Network, Tianjin University of Technology."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Yadav, R.K. (2019, January 28\u201330). GA and PSO hybrid algorithm for ANN training with application in Medical Diagnosis. Proceedings of the 2019 Third International Conference on Intelligent Computing in Data Sciences (ICDS), Marrakech, Morocco.","DOI":"10.1109\/ICDS47004.2019.8942375"},{"key":"ref_32","first-page":"5","article-title":"Magnetic nano temperature inversion algorithm based on PSO","volume":"11","author":"Ling","year":"2019","journal-title":"Electron. World"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/1361-6501\/aadebf","article-title":"Prediction of the tensile force applied on surface-hardened steel rods based on a CDIF and PSO-optimized neural network","volume":"29","author":"Zhu","year":"2018","journal-title":"Meas. Sci. Technol."},{"key":"ref_34","unstructured":"Li, Y.L., Liang, Y., Song, W., Liu, Q., and Qin, X.Y. (2015, January 14\u201315). Vegetable Price Prediction Based on PSO-BP Neural Network. Proceedings of the 2015 8th International Conference on Intelligent Computation Technology and Automation (ICICTA), Nanchang, China."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/5\/1619\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:28:42Z","timestamp":1760160522000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/5\/1619"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,25]]},"references-count":34,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2021,3]]}},"alternative-id":["s21051619"],"URL":"https:\/\/doi.org\/10.3390\/s21051619","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,25]]}}}