{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T07:02:28Z","timestamp":1777014148677,"version":"3.51.4"},"reference-count":45,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2021,3,12]],"date-time":"2021-03-12T00:00:00Z","timestamp":1615507200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The large and growing burden of chronic heart failure (CHF) on healthcare systems and economies is mainly caused by a high hospital admission rate for acute decompensated heart failure (HF). Several remote monitoring techniques have been developed for early detection of worsening disease, potentially limiting the number of hospitalizations. Over the last years, the scope has been shifting towards the relatively novel invasive sensors capable of measuring intracardiac filling pressures, because it is believed that hemodynamic congestion precedes clinical congestion. Monitoring intracardiac pressures may therefore enable clinicians to intervene and avert hospitalizations in a pre-symptomatic phase. Several techniques have been discussed in this review, and thus far, remote monitoring of pulmonary artery pressures (PAP) by the CardioMEMS (CardioMicroelectromechanical system) HF System is the only technique with proven safety as well as efficacy with regard to the prevention of HF-related hospital admissions. Efforts are currently aimed to further develop existing techniques and new sensors capable of measuring left atrial pressures (LAP). With the growing body of evidence and need for remote care, it is expected that remote monitoring by invasive sensors will play a larger role in HF care in the near future.<\/jats:p>","DOI":"10.3390\/s21062014","type":"journal-article","created":{"date-parts":[[2021,3,14]],"date-time":"2021-03-14T23:52:06Z","timestamp":1615765926000},"page":"2014","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Invasive Devices and Sensors for Remote Care of Heart Failure Patients"],"prefix":"10.3390","volume":"21","author":[{"given":"Sumant P.","family":"Radhoe","sequence":"first","affiliation":[{"name":"Thorax Center, Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7234-8266","authenticated-orcid":false,"given":"Jesse F.","family":"Veenis","sequence":"additional","affiliation":[{"name":"Thorax Center, Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jasper J.","family":"Brugts","sequence":"additional","affiliation":[{"name":"Thorax Center, Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,3,12]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1016\/j.jacc.2013.11.053","article-title":"The global health and economic burden of hospitalizations for heart failure: Lessons learned from hospitalized heart failure registries","volume":"63","author":"Ambrosy","year":"2014","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"e139","DOI":"10.1161\/CIR.0000000000000757","article-title":"Heart disease and stroke statistics-2020 update: A report from the american heart association","volume":"141","author":"Virani","year":"2020","journal-title":"Circulation"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1007\/s00392-012-0531-4","article-title":"Generic and disease-specific health-related quality of life in patients with chronic systolic heart failure: Impact of depression","volume":"102","author":"Schowalter","year":"2013","journal-title":"Clin. Res. Cardiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.ahj.2007.01.041","article-title":"Repeated hospitalizations predict mortality in the community population with heart failure","volume":"154","author":"Setoguchi","year":"2007","journal-title":"Am. Heart J."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1161\/CIRCHEARTFAILURE.113.001281","article-title":"Influence of previous heart failure hospitalization on cardiovascular events in patients with reduced and preserved ejection fraction","volume":"7","author":"Bello","year":"2014","journal-title":"Circ. Heart Fail."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"11G","DOI":"10.1016\/j.amjcard.2005.07.016","article-title":"Pathophysiologic targets in the early phase of acute heart failure syndromes","volume":"96","author":"Gheorghiade","year":"2005","journal-title":"Am. J. Cardiol."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Inglis, S.C., Clark, R.A., Dierckx, R., Prieto-Merino, D., and Cleland, J.G. (2015). Structured telephone support or non-invasive telemonitoring for patients with heart failure. Cochrane Database Syst. Rev., CD007228.","DOI":"10.1002\/14651858.CD007228.pub3"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1433","DOI":"10.1161\/CIRCULATIONAHA.108.783910","article-title":"Transition from chronic compensated to acute decompensated heart failure: Pathophysiological insights obtained from continuous monitoring of intracardiac pressures","volume":"118","author":"Zile","year":"2008","journal-title":"Circulation"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1007\/s11897-009-0039-z","article-title":"Pathophysiology of the transition from chronic compensated and acute decompensated heart failure: New insights from continuous monitoring devices","volume":"6","author":"Adamson","year":"2009","journal-title":"Curr. Heart Fail. Rep."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1161\/01.CIR.93.4.745","article-title":"Initial experience with an implantable hemodynamic monitor","volume":"93","author":"Steinhaus","year":"1996","journal-title":"Circulation"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1053\/euhj.1997.0563","article-title":"Continuous ambulatory haemodynamic monitoring with an implantable system. The feasibility of a new technique","volume":"19","author":"Ohlsson","year":"1998","journal-title":"Eur. Heart J."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1053\/euhj.2001.2690","article-title":"Continuous haemodynamic monitoring during withdrawal of diuretics in patients with congestive heart failure","volume":"23","author":"Braunschweig","year":"2002","journal-title":"Eur. Heart J."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1136\/hrt.68.8.230","article-title":"A new system for ambulatory pulmonary artery pressure recording","volume":"68","author":"Gibbs","year":"1992","journal-title":"Br. Heart J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1176","DOI":"10.1016\/0735-1097(94)00510-W","article-title":"Measurement of pulmonary artery diastolic pressure from the right ventricle","volume":"25","author":"Reynolds","year":"1995","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/S1071-9164(96)80008-X","article-title":"Measurement of pulmonary artery diastolic pressure from a right ventricular pressure transducer in patients with heart failure","volume":"2","author":"Chuang","year":"1996","journal-title":"J. Card. Fail."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/1071-9164(95)90018-7","article-title":"Monitoring of pulmonary arterial diastolic pressure through a right ventricular pressure transducer","volume":"1","author":"Ohlsson","year":"1995","journal-title":"J. Card. Fail."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1054\/jcaf.2002.32373","article-title":"Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: A multicenter, 12-month follow-up study of patients with chronic heart failure","volume":"8","author":"Magalski","year":"2002","journal-title":"J. Card. Fail."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/S0735-1097(02)02896-6","article-title":"Ongoing right ventricular hemodynamics in heart failure: Clinical value of measurements derived from an implantable monitoring system","volume":"41","author":"Adamson","year":"2003","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1016\/j.jacc.2007.10.061","article-title":"Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: The compass-hf study","volume":"51","author":"Bourge","year":"2008","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2129","DOI":"10.1093\/eurheartj\/ehw128","article-title":"2016 esc guidelines for the diagnosis and treatment of acute and chronic heart failure: The task force for the diagnosis and treatment of acute and chronic heart failure of the european society of cardiology (esc)developed with the special contribution of the heart failure association (hfa) of the esc","volume":"37","author":"Ponikowski","year":"2016","journal-title":"Eur. Heart J."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1056\/NEJMoa052256","article-title":"Trends in prevalence and outcome of heart failure with preserved ejection fraction","volume":"355","author":"Owan","year":"2006","journal-title":"N. Engl. J. Med."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1016\/j.jacc.2003.11.040","article-title":"Hospitalization for heart failure in the presence of a normal left ventricular ejection fraction: Results of the new york heart failure registry","volume":"43","author":"Klapholz","year":"2004","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1016\/S0735-1097(03)00185-2","article-title":"Outcomes in heart failure patients with preserved ejection fraction: Mortality, readmission, and functional decline","volume":"41","author":"Smith","year":"2003","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/S0140-6736(11)60101-3","article-title":"Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: A randomised controlled trial","volume":"377","author":"Abraham","year":"2011","journal-title":"Lancet"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/S0140-6736(15)00723-0","article-title":"Sustained efficacy of pulmonary artery pressure to guide adjustment of chronic heart failure therapy: Complete follow-up results from the champion randomised trial","volume":"387","author":"Abraham","year":"2016","journal-title":"Lancet"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2357","DOI":"10.1016\/j.jacc.2017.03.009","article-title":"Ambulatory hemodynamic monitoring reduces heart failure hospitalizations in \"real-world\" clinical practice","volume":"69","author":"Desai","year":"2017","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1001\/jamacardio.2019.1384","article-title":"Association of ambulatory hemodynamic monitoring of heart failure with clinical outcomes in a concurrent matched cohort analysis","volume":"4","author":"Abraham","year":"2019","journal-title":"JAMA Cardiol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"e006863","DOI":"10.1161\/CIRCHEARTFAILURE.119.006863","article-title":"Lower rates of heart failure and all-cause hospitalizations during pulmonary artery pressure-guided therapy for ambulatory heart failure: One-year outcomes from the cardiomems post-approval study","volume":"13","author":"Shavelle","year":"2020","journal-title":"Circ. Heart Fail."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1891","DOI":"10.1002\/ejhf.1943","article-title":"Pulmonary artery pressure-guided therapy in ambulatory patients with symptomatic heart failure: The cardiomems european monitoring study for heart failure (mems-hf)","volume":"22","author":"Angermann","year":"2020","journal-title":"Eur. J. Heart Fail."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1002\/ehf2.12646","article-title":"Rationale and design of the cardiomems post-market multinational clinical study: Coast","volume":"7","author":"Cowie","year":"2020","journal-title":"ESC Heart Fail."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s12471-019-01341-9","article-title":"A randomised comparison of the effect of haemodynamic monitoring with cardiomems in addition to standard care on quality of life and hospitalisations in patients with chronic heart failure: Design and rationale of the monitor hf multicentre randomised clinical trial","volume":"28","author":"Brugts","year":"2020","journal-title":"Neth. Heart J."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.ahj.2019.04.014","article-title":"Hemodynamic-guided management of heart failure (guide-hf)","volume":"214","author":"Lindenfeld","year":"2019","journal-title":"Am. Heart J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1002\/ejhf.1870","article-title":"Digital health care solution for proactive heart failure management with the cordella heart failure system: Results of the sirona first-in-human study","volume":"22","author":"Mullens","year":"2020","journal-title":"Eur. J. Heart Fail."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.cardfail.2015.04.012","article-title":"Rationale and design of the left atrial pressure monitoring to optimize heart failure therapy study (laptop-hf)","volume":"21","author":"Maurer","year":"2015","journal-title":"J. Card. Fail."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"3958","DOI":"10.1161\/CIRCULATIONAHA.105.590091","article-title":"Acute heart failure syndromes: Current state and framework for future research","volume":"112","author":"Gheorghiade","year":"2005","journal-title":"Circulation"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"S31","DOI":"10.1016\/j.hlc.2005.09.003","article-title":"The heartpod implantable heart failure therapy system","volume":"14","author":"Walton","year":"2005","journal-title":"Heart Lung Circ."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"271","DOI":"10.3389\/fphys.2015.00271","article-title":"Evolution from electrophysiologic to hemodynamic monitoring: The story of left atrial and pulmonary artery pressure monitors","volume":"6","author":"Mooney","year":"2015","journal-title":"Front. Physiol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"2952","DOI":"10.1161\/CIRCULATIONAHA.107.702191","article-title":"Direct left atrial pressure monitoring in ambulatory heart failure patients: Initial experience with a new permanent implantable device","volume":"116","author":"Ritzema","year":"2007","journal-title":"Circulation"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1086","DOI":"10.1161\/CIRCULATIONAHA.108.800490","article-title":"Physician-directed patient self-management of left atrial pressure in advanced chronic heart failure","volume":"121","author":"Ritzema","year":"2010","journal-title":"Circulation"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1111\/pace.12111","article-title":"An implantable left atrial pressure sensor lead designed for percutaneous extraction using standard techniques","volume":"36","author":"Pretorius","year":"2013","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1016\/j.cardfail.2016.09.012","article-title":"Hemodynamic monitoring in advanced heart failure: Results from the laptop-hf trial","volume":"22","author":"Abraham","year":"2016","journal-title":"J. Card. Fail."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.jchf.2015.12.015","article-title":"Cost-effectiveness of implantable pulmonary artery pressure monitoring in chronic heart failure","volume":"4","author":"Sandhu","year":"2016","journal-title":"JACC Heart Fail."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1002\/clc.22696","article-title":"Cost-effectiveness of remote cardiac monitoring with the cardiomems heart failure system","volume":"40","author":"Schmier","year":"2017","journal-title":"Clin. Cardiol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1007\/s12471-018-1103-7","article-title":"Real-world heart failure management in 10,910 patients with chronic heart failure in the netherlands: Design and rationale of the chronic heart failure esc guideline-based cardiology practice quality project (check-hf) registry","volume":"26","author":"Brugts","year":"2018","journal-title":"Neth. Heart J."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1016\/j.jacc.2017.04.025","article-title":"2017 acc\/aha\/hfsa focused update of the 2013 accf\/aha guideline for the management of heart failure: A report of the american college of cardiology\/american heart association task force on clinical practice guidelines and the heart failure society of america","volume":"70","author":"Yancy","year":"2017","journal-title":"J. Am. Coll. Cardiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/6\/2014\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:34:51Z","timestamp":1760160891000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/6\/2014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,12]]},"references-count":45,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2021,3]]}},"alternative-id":["s21062014"],"URL":"https:\/\/doi.org\/10.3390\/s21062014","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,12]]}}}