{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T01:20:21Z","timestamp":1771377621682,"version":"3.50.1"},"reference-count":34,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2021,3,16]],"date-time":"2021-03-16T00:00:00Z","timestamp":1615852800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"FLAG-ERA","award":["JTC-2016_003"],"award-info":[{"award-number":["JTC-2016_003"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This article describes the design and the characterization of the ANTIGONE (ANalog To dIGital cONvErter) ASIC (Application Specific Integrated Circuit) built in AMS 0.35 m technology for low dc-current sensing. This energy-efficient ASIC was specifically designed to interface with multiple Ion-Sensitive Field-Effect Transistors (ISFETs) and detect biomarkers like pH, Na+, K+ and Ca2+ in human sweat. The ISFET-ASIC system can allow real-time noninvasive and continuous health monitoring. The ANTIGONE ASIC architecture is based on the current-to-frequency converter through the charge balancing principle. The same front-end can digitize multiple currents produced by four sweat ISFET sensors in time multiplexing. The front-end demonstrates good linearity over a dynamic range that spans from 1 pA up to 500 nA. The consumed energy per conversion is less than 1 J. The chip is programmable and works in eight different modes of operation. The system uses a standard Serial Peripheral Interface (SPI) to configure, control and read the digitally converted sensor data. The chip is controlled by a portable device over Bluetooth Low Energy (BLE) through a Microcontroller Unit (MCU). The sweat sensing system is part of a bigger wearable platform that exploits the convergence of multiparameter biosensors and environmental sensors for personalized and preventive healthcare.<\/jats:p>","DOI":"10.3390\/s21062074","type":"journal-article","created":{"date-parts":[[2021,3,16]],"date-time":"2021-03-16T21:42:41Z","timestamp":1615930961000},"page":"2074","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["ANTIGONE: A Programmable Energy-Efficient Current Digitizer for an ISFET Wearable Sweat Sensing System"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6420-6206","authenticated-orcid":false,"given":"Evgenia","family":"Voulgari","sequence":"first","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fran\u00e7ois","family":"Krummenacher","sequence":"additional","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maher","family":"Kayal","sequence":"additional","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,3,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.tibtech.2014.04.005","article-title":"Non-invasive wearable electrochemical sensors: A review","volume":"32","author":"Bandodkar","year":"2014","journal-title":"Trends Biotechnol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1038\/s41587-019-0040-3","article-title":"Accessing analytes in biofluids for peripheral biochemical monitoring","volume":"37","author":"Heikenfeld","year":"2019","journal-title":"Nat. Biotechnol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"19017","DOI":"10.1073\/pnas.2009979117","article-title":"Noninvasive wearable electroactive pharmaceutical monitoring for personalized therapeutics","volume":"117","author":"Lin","year":"2020","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1039\/C7CS00730B","article-title":"Wearable and flexible electronics for continuous molecular monitoring","volume":"48","author":"Yang","year":"2019","journal-title":"Chem. Soc. Rev."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/j.trechm.2019.07.001","article-title":"Body-interfaced chemical sensors for noninvasive monitoring and analysis of biofluids","volume":"1","author":"Zhao","year":"2019","journal-title":"Trends Chem."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Choi, J., Ghaffari, R., Baker, L.B., and Rogers, J.A. (2018). Skin-interfaced systems for sweat collection and analytics. Sci. Adv., 4.","DOI":"10.1126\/sciadv.aar3921"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1146\/annurev-anchem-061318-114910","article-title":"Wearable sensors for biochemical sweat analysis","volume":"12","author":"Bandodkar","year":"2019","journal-title":"Annu. Rev. Anal. Chem."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Ghaffari, R., Rogers, J.A., and Ray, T.R. (2021). Recent progress, challenges, and opportunities for wearable biochemical sensors for sweat analysis. Sens. Actuators B Chem., 332.","DOI":"10.1016\/j.snb.2021.129447"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Wu, W., and Haick, H. (2018). Materials and wearable devices for autonomous monitoring of physiological markers. Adv. Mater., 30.","DOI":"10.1002\/adma.201705024"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Gao, W., Nyein, H.Y., Shahpar, Z., Tai, L.C., Wu, E., Bariya, M., Ota, H., Fahad, H.M., Chen, K., and Javey, A. (2016, January 3\u20137). Wearable sweat biosensors. Proceedings of the 2016 IEEE International Electron Devices Meeting (IEDM), San Francisco, CA, USA.","DOI":"10.1109\/IEDM.2016.7838363"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"An, Q., Gan, S., Xu, J., Bao, Y., Wu, T., Kong, H., Zhong, L., Ma, Y., Song, Z., and Niu, L. (2019). A multichannel electrochemical all-solid-state wearable potentiometric sensor for real-time sweat ion monitoring. Electrochem. Commun., 107.","DOI":"10.1016\/j.elecom.2019.106553"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1021\/acsabm.0c00798","article-title":"Wearable Sensing Devices for Point of Care Diagnostics","volume":"4","author":"Mondal","year":"2021","journal-title":"ACS Appl. Bio Mater."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/ncomms11650","article-title":"A wearable chemical\u2013electrophysiological hybrid biosensing system for real-time health and fitness monitoring","volume":"7","author":"Imani","year":"2016","journal-title":"Nat. Commun."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"8594","DOI":"10.1039\/D0RA00016G","article-title":"Flexible potentiometric pH sensors for wearable systems","volume":"10","author":"Manjakkal","year":"2020","journal-title":"RSC Adv."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1038\/nature16521","article-title":"Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis","volume":"529","author":"Gao","year":"2016","journal-title":"Nature"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.bios.2016.09.038","article-title":"A wearable multisensing patch for continuous sweat monitoring","volume":"93","author":"Anastasova","year":"2017","journal-title":"Biosens. Bioelectron."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1021\/acssensors.7b00047","article-title":"Wearable, flexible, and multifunctional healthcare device with an ISFET chemical sensor for simultaneous sweat pH and skin temperature monitoring","volume":"2","author":"Nakata","year":"2017","journal-title":"ACS Sens."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.snb.2009.09.018","article-title":"ISFET characteristics in CMOS and their application to weak inversion operation","volume":"143","author":"Georgiou","year":"2009","journal-title":"Sens. Actuators B Chem."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1109\/JSEN.2018.2881499","article-title":"ISFET arrays in CMOS: A head-to-head comparison between voltage and current mode","volume":"19","author":"Miscourides","year":"2018","journal-title":"IEEE Sens. J."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Bellando, F., Garcia-Cordero, E., Wildhaber, F., Longo, J., Gu\u00e9rin, H., and Ionescu, A. (2017, January 2\u20136). Lab on skin\u2122: 3D monolithically integrated zero-energy micro\/nanofludics and FD SOI ion sensitive FETs for wearable multi-sensing sweat applications. Proceedings of the 2017 IEEE International Electron Devices Meeting (IEDM), San Francisco, CA, USA.","DOI":"10.1109\/IEDM.2017.8268413"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"4872","DOI":"10.1021\/nn5064216","article-title":"Sensing with advanced computing technology: Fin field-effect transistors with high-k gate stack on bulk silicon","volume":"9","author":"Rigante","year":"2015","journal-title":"ACS Nano"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1021\/acssensors.9b00597","article-title":"Sweat Biomarker Sensor Incorporating Picowatt, Three-Dimensional Extended Metal Gate Ion Sensitive Field Effect Transistors","volume":"4","author":"Zhang","year":"2019","journal-title":"ACS Sens."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Garcia-Cordero, E., Guerin, H., Muhech, A., Bellando, F., and Ionescu, A.M. (2016, January 12\u201315). Heterogeneous integration of low power pH FinFET sensors with passive capillary microfluidics and miniaturized Ag\/AgCl quasi-Reference Electrode. Proceedings of the 2016 46th European Solid-State Device Research Conference (ESSDERC), Lausanne, Switzerland.","DOI":"10.1109\/ESSDERC.2016.7599683"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Li, H., Liu, X., Li, L., Mu, X., Genov, R., and Mason, A.J. (2017). CMOS electrochemical instrumentation for biosensor microsystems: A review. Sensors, 17.","DOI":"10.3390\/s17010074"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1007\/s10470-013-0138-3","article-title":"An ultra-low power energy-efficient microsystem for hydrogen gas sensing applications","volume":"77","author":"Pour","year":"2013","journal-title":"Analog Integr. Circuits Signal Process."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1109\/TCSI.2004.826202","article-title":"Theory and applications of incremental\/spl Delta\/\/spl Sigma\/converters","volume":"51","author":"Silva","year":"2004","journal-title":"IEEE Trans. Circuits Syst. I: Regul. Pap."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1007\/BF01239381","article-title":"An analytical MOS transistor model valid in all regions of operation and dedicated to low-voltage and low-current applications","volume":"8","author":"Enz","year":"1995","journal-title":"Analog Integr. Circuits Signal Process."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/j.snb.2007.05.001","article-title":"A composite ISFET readout circuit employing current feedback","volume":"127","author":"Premanode","year":"2007","journal-title":"Sens. Actuators B Chem."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1109\/TCSI.2008.2005927","article-title":"Current-mirror-based potentiostats for three-electrode amperometric electrochemical sensors","volume":"56","author":"Ahmadi","year":"2008","journal-title":"IEEE Trans. Circuits Syst. I: Regul. Pap."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/S0168-9002(97)01209-6","article-title":"Performances of a VLSI wide dynamic range current-to-frequency converter for strip ionization chambers","volume":"405","author":"Bonazzola","year":"1998","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1109\/TNS.2018.2803339","article-title":"Utopia: A Nine Decade Femtoampere Sensitivity Current Digitizer and its Application in Ionizing Radiation Monitoring","volume":"65","author":"Voulgari","year":"2018","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_32","unstructured":"Carusone, T., Johns, D., and Martin, K. (2011). Switched Capacitor Circuits. Analog Integr. Circuit Des., 557\u2013605."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/0167-5087(83)90652-X","article-title":"Charge-balancing current integrator with large dynamic range","volume":"207","author":"Gottschalk","year":"1983","journal-title":"Nucl. Instrum. Methods Phys. Res."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Carrara, S., Torre, M.D., Cavallini, A., De Venuto, D., and De Micheli, G. (2010, January 3\u20135). Multiplexing pH and temperature in a molecular biosensor. Proceedings of the 2010 Biomedical Circuits and Systems Conference (BioCAS), Paphos, Cyprus.","DOI":"10.1109\/BIOCAS.2010.5709592"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/6\/2074\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:36:18Z","timestamp":1760160978000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/6\/2074"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,16]]},"references-count":34,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2021,3]]}},"alternative-id":["s21062074"],"URL":"https:\/\/doi.org\/10.3390\/s21062074","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,16]]}}}