{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T08:38:41Z","timestamp":1773823121576,"version":"3.50.1"},"reference-count":74,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2021,4,15]],"date-time":"2021-04-15T00:00:00Z","timestamp":1618444800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100006769","name":"Russian Science Foundation","doi-asserted-by":"publisher","award":["19-73-10205"],"award-info":[{"award-number":["19-73-10205"]}],"id":[{"id":"10.13039\/501100006769","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100006769","name":"Russian Science Foundation","doi-asserted-by":"publisher","award":["18-74-10098"],"award-info":[{"award-number":["18-74-10098"]}],"id":[{"id":"10.13039\/501100006769","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The ever-increasing use of magnetic particle bioconjugates (MPB) in biosensors calls for methods of comprehensive characterization of their interaction with targets. Label-free optical sensors commonly used for studying inter-molecular interactions have limited potential for MPB because of their large size and multi-component non-transparent structure. We present an easy-to-use method that requires only three 20-min express measurements to determine the key parameters for selection of optimal MPB for a biosensor: kinetic and equilibrium characteristics, and a fraction of biomolecules on the MPB surface that are capable of active targeting. The method also provides a prognostic dependence of MPB targeting efficiency upon interaction duration and sample volume. These features are possible due to joining a magnetic lateral flow assay, a highly sensitive sensor for MPB detection by the magnetic particle quantification technique, and a novel mathematical model that explicitly describes the MPB-target interactions and does not comprise parameters to be fitted additionally. The method was demonstrated by experiments on MPB targeting of cardiac troponin I and staphylococcal enterotoxin B. The validation by an independent label-free technique of spectral-correlation interferometry showed good correlation between the results obtained by both methods. The presented method can be applied to other targets for faster development and selection of MPB for affinity sensors, analytical technologies, and realization of novel concepts of MPB-based biosensing in vivo.<\/jats:p>","DOI":"10.3390\/s21082802","type":"journal-article","created":{"date-parts":[[2021,4,15]],"date-time":"2021-04-15T21:35:13Z","timestamp":1618522513000},"page":"2802","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Rapid and Easy-to-Use Method for Accurate Characterization of Target Binding and Kinetics of Magnetic Particle Bioconjugates for Biosensing"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7025-1225","authenticated-orcid":false,"given":"Averyan V.","family":"Pushkarev","sequence":"first","affiliation":[{"name":"Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov Str., 119991 Moscow, Russia"},{"name":"Moscow Institute of Physics and Technology, 9 Institutskii per., Dolgoprudny, 141700 Moscow Region, Russia"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7408-3927","authenticated-orcid":false,"given":"Alexey V.","family":"Orlov","sequence":"additional","affiliation":[{"name":"Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov Str., 119991 Moscow, Russia"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1265-328X","authenticated-orcid":false,"given":"Sergey L.","family":"Znoyko","sequence":"additional","affiliation":[{"name":"Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov Str., 119991 Moscow, Russia"}]},{"given":"Vera A.","family":"Bragina","sequence":"additional","affiliation":[{"name":"Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov Str., 119991 Moscow, Russia"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1573-5512","authenticated-orcid":false,"given":"Petr I.","family":"Nikitin","sequence":"additional","affiliation":[{"name":"Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov Str., 119991 Moscow, Russia"}]}],"member":"1968","published-online":{"date-parts":[[2021,4,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Krishnan, S., and Goud, K.Y. (2019). Magnetic Particle Bioconjugates: A Versatile Sensor Approach. Magnetochemistry, 5.","DOI":"10.3390\/magnetochemistry5040064"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Chen, Y.-T., Kolhatkar, A.G., Zenasni, O., Xu, S., and Lee, T.R. (2017). Biosensing Using Magnetic Particle Detection Techniques. Sensors, 17.","DOI":"10.3390\/s17102300"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Kudr, J., Haddad, Y., Richtera, L., Heger, Z., Cernak, M., Adam, V., and Zitka, O. (2017). Magnetic Nanoparticles: From Design and Synthesis to Real World Applications. Nanomaterials, 7.","DOI":"10.3390\/nano7090243"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/bs.mie.2015.10.005","article-title":"Bioconjugation of Antibodies and Enzyme Labels onto Magnetic Beads","volume":"Volume 571","author":"Kumar","year":"2016","journal-title":"Methods in Enzymology"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"224003","DOI":"10.1088\/0022-3727\/42\/22\/224003","article-title":"Progress in Functionalization of Magnetic Nanoparticles for Applications in Biomedicine","volume":"42","author":"Berry","year":"2009","journal-title":"J. Phys D. Appl. Phys."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1134\/S0965545X0604002X","article-title":"Synthesis of polymer magnetic microspheres for immunomagnetometric assay","volume":"48","author":"Cherkasov","year":"2006","journal-title":"Polym. Sci. Ser. A"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.jmmm.2006.10.1180","article-title":"New type of biosensor based on magnetic nanoparticle detection","volume":"311","author":"Nikitin","year":"2007","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.trac.2014.06.016","article-title":"Sensors and biosensors based on magnetic nanoparticles","volume":"62","year":"2014","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/j.trac.2015.10.022","article-title":"Magnetic particles: From preparation to lab-on-a-chip, biosensors, microsystems and microfluidics applications","volume":"79","author":"Jamshaid","year":"2016","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"11642","DOI":"10.1039\/C8NR01511B","article-title":"Ultrasensitive detection enabled by nonlinear magnetization of nanomagnetic labels","volume":"10","author":"Nikitin","year":"2018","journal-title":"Nanoscale"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Khan, R., Rehman, A., Hayat, A., and Andreescu, S. (2019). Magnetic Particles-Based Analytical Platforms for Food Safety Monitoring. Magnetochemistry, 5.","DOI":"10.3390\/magnetochemistry5040063"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"9973","DOI":"10.1021\/acs.chemrev.7b00037","article-title":"Nanoparticle-Based Immunochemical Biosensors and Assays: Recent Advances and Challenges","volume":"117","author":"Farka","year":"2017","journal-title":"Chem. Rev."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1951","DOI":"10.1166\/jbn.2013.1701","article-title":"Bioconjugated Magnetic Nanoparticles for the Detection of Bacteria","volume":"9","author":"Chu","year":"2013","journal-title":"J. Biomed. Nanotechnol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1586\/erm.12.54","article-title":"Magnetic particle-based ultrasensitive biosensors for diagnostics","volume":"12","author":"Zhang","year":"2012","journal-title":"Expert Rev. Mol. Diagn."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1038\/nnano.2011.45","article-title":"Quantification of protein interactions and solution transport using high-density GMR sensor arrays","volume":"6","author":"Gaster","year":"2011","journal-title":"Nat. Nanotechnol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"502003","DOI":"10.1088\/1361-6528\/ab4241","article-title":"Magnetic nanoparticles in nanomedicine: A review of recent advances","volume":"30","author":"Wu","year":"2019","journal-title":"Nanotechnology"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1594","DOI":"10.1021\/acssensors.7b00432","article-title":"Portable GMR Handheld Platform for the Detection of Influenza A Virus","volume":"2","author":"Wu","year":"2017","journal-title":"ACS Sens."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/j.jconrel.2011.06.001","article-title":"Targeted drug delivery to tumors: Myths, reality and possibility","volume":"153","author":"Bae","year":"2011","journal-title":"J. Control. Release"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1038\/nnano.2014.156","article-title":"Biocomputing based on particle disassembly","volume":"9","author":"Nikitin","year":"2014","journal-title":"Nat. Nanotechnol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"10294","DOI":"10.1021\/acs.chemrev.8b00198","article-title":"Advanced Smart Nanomaterials with Integrated Logic-Gating and Biocomputing: Dawn of Theranostic Nanorobots","volume":"118","author":"Tregubov","year":"2018","journal-title":"Chem. Rev."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1080\/10739149.2013.843060","article-title":"Optical biosensors for label-free detection of biomolecular interactions","volume":"42","author":"Sun","year":"2014","journal-title":"Instrum. Sci. Technol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"3576","DOI":"10.1039\/c3an36828a","article-title":"Label-free methods of reporting biomolecular interactions by optical biosensors","volume":"138","author":"Citartan","year":"2013","journal-title":"Analyst"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Peltomaa, R., Glahn-Mart\u00ednez, B., Benito-Pe\u00f1a, E., and Moreno-Bondi, M.C. (2018). Optical Biosensors for Label-Free Detection of Small Molecules. Sensors, 18.","DOI":"10.3390\/s18124126"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1515\/nanoph-2016-0158","article-title":"Emerging applications of label-free optical biosensors","volume":"6","author":"Zanchetta","year":"2017","journal-title":"Nanophotonics"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.snb.2017.11.025","article-title":"Development and label-free investigation of logic-gating biolayers for smart biosensing","volume":"257","author":"Orlov","year":"2018","journal-title":"Sens. Actuators B Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"10481","DOI":"10.3390\/s150510481","article-title":"Surface Plasmon Resonance: A Versatile Technique for Biosensor Applications","volume":"15","author":"Nguyen","year":"2015","journal-title":"Sensors"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Puiu, M., and Bala, C. (2016). SPR and SPR Imaging: Recent Trends in Developing Nanodevices for Detection and Real-Time Monitoring of Biomolecular Events. Sensors, 16.","DOI":"10.3390\/s16060870"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Wang, D., Loo, J.F.C., Chen, J., Yam, Y., Chen, S.-C., He, H., Kong, S.K., and Ho, H.P. (2019). Recent Advances in Surface Plasmon Resonance Imaging Sensors. Sensors, 19.","DOI":"10.3390\/s19061266"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1080\/10408347.2014.881250","article-title":"Surface Plasmon Resonance (SPR) Biosensors in Pharmaceutical Analysis","volume":"45","author":"Olaru","year":"2015","journal-title":"Crit. Rev. Anal. Chem."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"7247","DOI":"10.1002\/anie.201600853","article-title":"Individual Detection and Electrochemically Assisted Identification of Adsorbed Nanoparticles by Using Surface Plasmon Microscopy","volume":"55","author":"Nizamov","year":"2016","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"3952","DOI":"10.1364\/OE.19.003952","article-title":"Silicon-polymer hybrid slot waveguide ring-resonator modulator","volume":"19","author":"Gould","year":"2011","journal-title":"Opt. Express"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"4751","DOI":"10.3390\/s90604751","article-title":"Optical slot-waveguide based biochemical sensors","volume":"9","author":"Barrios","year":"2009","journal-title":"Sensors"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"7994","DOI":"10.1364\/OE.21.007994","article-title":"Silicon photonic micro-disk resonators for label-free biosensing","volume":"21","author":"Grist","year":"2013","journal-title":"Opt. Express"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"791","DOI":"10.2174\/138620709789104915","article-title":"Label-free detection of biomolecular interactions using BioLayer interferometry for kinetic characterization","volume":"12","author":"Concepcion","year":"2009","journal-title":"Comb. Chem. High Throughput Screen."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"7988","DOI":"10.1073\/pnas.0711421105","article-title":"Label-free and dynamic detection of biomolecular interactions for high-throughput microarray applications","volume":"105","author":"Ozkumur","year":"2008","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"112187","DOI":"10.1016\/j.bios.2020.112187","article-title":"Multiplex label-free biosensor for detection of autoantibodies in human serum: Tool for new kinetics-based diagnostics of autoimmune diseases","volume":"159","author":"Orlov","year":"2020","journal-title":"Biosens. Bioelectron."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1016\/j.snb.2012.09.058","article-title":"Efficient design and optimization of bio-photonic sensing cells (BICELLs) for label free biosensing","volume":"176","author":"Casquel","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"012003","DOI":"10.1088\/2515-7647\/abac19","article-title":"Optobiology: Live cells in optics and photonics","volume":"3","author":"Miccio","year":"2020","journal-title":"J. Phys. Photonics"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"4180","DOI":"10.3390\/s100504180","article-title":"CMOS-integrated film bulk acoustic resonators for label-free biosensing","volume":"10","author":"Nirschl","year":"2010","journal-title":"Sensors"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"5061","DOI":"10.1039\/C8AY01913D","article-title":"Graphene-based biosensors for on-site detection of contaminants in food","volume":"10","author":"Bobrinetskiy","year":"2018","journal-title":"Anal. Methods"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"12227","DOI":"10.1021\/jp0725681","article-title":"Magnetic Particles as Labels in Bioassays: Interactions between a Biotinylated Gold Substrate and Streptavidin Magnetic Particles","volume":"111","author":"Liu","year":"2007","journal-title":"J. Phys. Chem. C"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.jmmm.2014.10.019","article-title":"A new real-time method for investigation of affinity properties and binding kinetics of magnetic nanoparticles","volume":"380","author":"Orlov","year":"2015","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"2357","DOI":"10.1021\/ac900007c","article-title":"Surface Plasmon Resonance Detection Using Antibody-Linked Magnetic Nanoparticles for Analyte Capture, Purification, Concentration, and Signal Amplification","volume":"81","author":"Soelberg","year":"2009","journal-title":"Anal. Chem."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/0022-1759(88)90376-6","article-title":"Kinetics of antigen-antibody reactions at solid-liquid interfaces","volume":"113","author":"Stenberg","year":"1988","journal-title":"J. Immunol. Methods"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"9852","DOI":"10.1021\/acs.analchem.9b01519","article-title":"Analytical Platform with Selectable Assay Parameters Based on Three Functions of Magnetic Nanoparticles: Demonstration of Highly Sensitive Rapid Quantitation of Staphylococcal Enterotoxin B in Food","volume":"91","author":"Bragina","year":"2019","journal-title":"Anal. Chem."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"221","DOI":"10.2310\/7290.2009.00021","article-title":"Comparative analysis of nanoparticle-antibody conjugations: Carbodiimide versus click chemistry","volume":"8","author":"Thorek","year":"2009","journal-title":"Mol. Imaging"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1006\/abio.1994.1144","article-title":"A method for the high efficiency of water-soluble carbodiimide-mediated amidation","volume":"218","author":"Sehgal","year":"1994","journal-title":"Anal. Biochem."},{"key":"ref_48","unstructured":"Nikitin, P.I., and Vetoshko, P.M. (2002). Process of Analysis of Mixture of Biological and\/or Chemical Components with use of Magnetic Particles and Device for its Implementation. (1262766), Patent EP, Patent RU 2166751, 10 May 2001."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.jmmm.2017.10.078","article-title":"Multiplex biosensing with highly sensitive magnetic nanoparticle quantification method","volume":"459","author":"Nikitin","year":"2018","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"5659","DOI":"10.1039\/C9AN00964G","article-title":"Algorithms for immunochromatographic assay: Review and impact on future application","volume":"144","author":"Qin","year":"2019","journal-title":"Analyst"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1007\/s00216-008-2287-2","article-title":"Lateral flow (immuno)assay: Its strengths, weaknesses, opportunities and threats. A literature survey","volume":"393","author":"Korf","year":"2009","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/S0925-4005(03)00020-0","article-title":"New direct optical biosensors for multi-analyte detection","volume":"90","author":"Nikitin","year":"2003","journal-title":"Sens. Actuators B Chem."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1080","DOI":"10.1016\/j.snb.2016.12.071","article-title":"Highly reproducible and sensitive detection of mycotoxins by label-free biosensors","volume":"246","author":"Orlov","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.aca.2018.07.012","article-title":"Ultrasensitive quantitative detection of small molecules with rapid lateral-flow assay based on high-affinity bifunctional ligand and magnetic nanolabels","volume":"1034","author":"Znoyko","year":"2018","journal-title":"Anal. Chim. Acta"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1134\/S0003683813030058","article-title":"Detection of pyrethroids by spectral correlation interferometry","volume":"49","author":"Burenin","year":"2013","journal-title":"Appl. Biochem. Microbiol."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"4518","DOI":"10.1021\/cr050205w","article-title":"Modeling the kinetics of bimolecular reactions","volume":"106","author":"Miller","year":"2006","journal-title":"Chem. Rev."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1016\/j.cej.2007.10.021","article-title":"Flow effects on the kinetics of a second-order reaction","volume":"140","author":"Nguyen","year":"2008","journal-title":"Chem. Eng. J."},{"key":"ref_58","first-page":"5","article-title":"Reaction kinetics basics","volume":"Volume 20","author":"Tomlin","year":"2014","journal-title":"Analysis of Kinetic Reaction Mechanisms"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13568-019-0852-z","article-title":"Glycosylation influences activity, stability and immobilization of the feruloyl esterase 1a from Myceliophthora thermophila","volume":"9","author":"Bonzom","year":"2019","journal-title":"AMB Express"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.snb.2011.08.058","article-title":"Analytes kinetics in lateral flow membrane analyzed by cTnI monitoring using magnetic method","volume":"160","author":"Oh","year":"2011","journal-title":"Sens. Actuators B Chem."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"16420","DOI":"10.3390\/s121216420","article-title":"Applications of surface plasmon resonance (SPR) for the characterization of nanoparticles developed for biomedical purposes","volume":"12","author":"Canovi","year":"2012","journal-title":"Sensors"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.apradiso.2005.06.007","article-title":"Measuring the affinity of a radioligand with its receptor using a rotating cell dish with in situ reference area","volume":"64","author":"Andersson","year":"2006","journal-title":"Appl. Radiat. Isot."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"7982","DOI":"10.1021\/ja910372e","article-title":"Direct observation of adsorption-induced inactivation of antibody fragments surrounded by mixed-PEG layer on a gold surface","volume":"132","author":"Yoshimoto","year":"2010","journal-title":"J. Am. Chem. Soc."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"8158","DOI":"10.1021\/ac501536z","article-title":"How Antibody Surface Coverage on Nanoparticles Determines the Activity and Kinetics of Antigen Capturing for Biosensing","volume":"86","author":"Saha","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1016\/j.snb.2017.04.024","article-title":"The effect of report particle properties on lateral flow assays: A mathematical model","volume":"248","author":"Liu","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"2737","DOI":"10.1021\/acs.bioconjchem.7b00489","article-title":"Less is More: A Comparison of Antibody-Gold Nanoparticle Conjugates of Different Ratios","volume":"28","author":"Byzova","year":"2017","journal-title":"Bioconjug. Chem."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.jcis.2016.03.001","article-title":"Optimisation of immuno-gold nanoparticle complexes for antigen detection","volume":"471","author":"Russell","year":"2016","journal-title":"J. Colloid Interface Sci."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"8253","DOI":"10.1021\/acsomega.8b00591","article-title":"Quantifying Bound and Active Antibodies Conjugated to Gold Nanoparticles: A Comprehensive and Robust Approach To Evaluate Immobilization Chemistry","volume":"3","author":"Tripathi","year":"2018","journal-title":"ACS Omega"},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"474012","DOI":"10.1088\/0022-3727\/43\/47\/474012","article-title":"Designing novel nano-immunoassays: Antibody orientation versus sensitivity","volume":"43","author":"Puertas","year":"2010","journal-title":"J. Phys. D. Appl. Phys."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1016\/j.talanta.2019.05.104","article-title":"Direct quantification of surface coverage of antibody in IgG-Gold nanoparticles conjugates","volume":"204","author":"Zhang","year":"2019","journal-title":"Talanta"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"2691","DOI":"10.1021\/acs.bioconjchem.8b00366","article-title":"Characterizing the Surface Coverage of Protein-Gold Nanoparticle Bioconjugates","volume":"29","author":"Kozlowski","year":"2018","journal-title":"Bioconjug. Chem."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"3851","DOI":"10.1039\/C6AN00193A","article-title":"A fluorescence-based method to directly quantify antibodies immobilized on gold nanoparticles","volume":"141","author":"Filbrun","year":"2016","journal-title":"Analyst"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"A.3A.1","DOI":"10.1002\/cpph.3","article-title":"Assays for Determination of Protein Concentration","volume":"73","author":"Olson","year":"2016","journal-title":"Curr. Protoc. Pharmacol."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"2287","DOI":"10.1021\/acs.bioconjchem.6b00207","article-title":"Facile Preparation of Stable Antibody-Gold Conjugates and Application to Affinity-Capture Self-Interaction Nanoparticle Spectroscopy","volume":"27","author":"Geng","year":"2016","journal-title":"Bioconjug. Chem."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/8\/2802\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:48:33Z","timestamp":1760161713000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/8\/2802"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,15]]},"references-count":74,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2021,4]]}},"alternative-id":["s21082802"],"URL":"https:\/\/doi.org\/10.3390\/s21082802","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,15]]}}}