{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T14:45:50Z","timestamp":1775745950059,"version":"3.50.1"},"reference-count":38,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2021,5,21]],"date-time":"2021-05-21T00:00:00Z","timestamp":1621555200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"JSPS KAKENHI","award":["P19H02385"],"award-info":[{"award-number":["P19H02385"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Heart rate measurement using a continuous wave Doppler radar sensor (CW-DRS) has been applied to cases where non-contact detection is required, such as the monitoring of vital signs in home healthcare. However, as a CW-DRS measures the speed of movement of the chest surface, which comprises cardiac and respiratory signals by body motion, extracting cardiac information from the superimposed signal is difficult. Therefore, it is challenging to extract cardiac information from superimposed signals. Herein, we propose a novel method based on a matched filter to solve this problem. The method comprises two processes: adaptive generation of a template via singular value decomposition of a trajectory matrix formed from the measurement signals, and reconstruction by convolution of the generated template and measurement signals. The method is validated using a dataset obtained in two different experiments, i.e., experiments involving supine and seated subject postures. Absolute errors in heart rate and standard deviation of heartbeat interval with references were calculated as 1.93\u00b11.76bpm and 57.0\u00b128.1s for the lying posture, and 9.72\u00b17.86bpm and 81.3\u00b124.3s for the sitting posture.<\/jats:p>","DOI":"10.3390\/s21113588","type":"journal-article","created":{"date-parts":[[2021,5,24]],"date-time":"2021-05-24T00:01:20Z","timestamp":1621814480000},"page":"3588","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["High Accuracy Heartbeat Detection from CW-Doppler Radar Using Singular Value Decomposition and Matched Filter"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7702-8138","authenticated-orcid":false,"given":"Yuki","family":"Iwata","sequence":"first","affiliation":[{"name":"Graduate School of Informatics and Engineering, The University of Electro-Communications (UEC), Tokyo 182-8585, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Han Trong","family":"Thanh","sequence":"additional","affiliation":[{"name":"School of Electronics and Telecommunications, Hanoi University of Science and Technology (HUST), Hanoi 100000, Vietnam"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5639-3171","authenticated-orcid":false,"given":"Guanghao","family":"Sun","sequence":"additional","affiliation":[{"name":"Graduate School of Informatics and Engineering, The University of Electro-Communications (UEC), Tokyo 182-8585, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichiro","family":"Ishibashi","sequence":"additional","affiliation":[{"name":"Graduate School of Informatics and Engineering, The University of Electro-Communications (UEC), Tokyo 182-8585, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,5,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Iwata, Y., Ishibashi, K., Sun, G., Ha, L.M., Thanh, H.T., Trung, N.L., and Tuan, D.T. (2020, January 20\u201324). Contactless Heartbeat Detection from CW-Doppler Radar using Windowed-Singular Spectrum Analysis. Proceedings of the 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Montreal, QC, Canada.","DOI":"10.1109\/EMBC44109.2020.9175441"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1002\/bem.2250130610","article-title":"Microwave sensing of physiological movement and volume change: A review","volume":"13","author":"Lin","year":"1992","journal-title":"Bioelectromagnetics"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1109\/10.817625","article-title":"Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier","volume":"47","author":"Chen","year":"2000","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1109\/TBME.2013.2288319","article-title":"Noncontact accurate measurement of cardiopulmonary activity using a compact quadrature Doppler radar sensor","volume":"61","author":"Hu","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"14383","DOI":"10.3402\/jchimp.v2i1.14383","article-title":"A brief review: History to understand fundamentals of electrocardiography","volume":"2","author":"Alghatrif","year":"2012","journal-title":"J. Community Hospit. Intern. Med. Perspect."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2820","DOI":"10.1109\/TIM.2018.2829488","article-title":"Improving Photoplethysmographic Measurements Under Motion Artifacts Using Artificial Neural Network for Personal Healthcare","volume":"67","author":"Roy","year":"2018","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2046","DOI":"10.1109\/TMTT.2013.2256924","article-title":"A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring","volume":"61","author":"Li","year":"2013","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Thi Phuoc Van, N., Tang, L., Demir, V., Hasan, S.F., Duc Minh, N., and Mukhopadhyay, S. (2019). Review-Microwave Radar Sensing Systems for Search and Rescue Purposes. Sensors, 19.","DOI":"10.3390\/s19132879"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Gu, C. (2016). Short-Range Noncontact Sensors for Healthcare and Other Emerging Applications: A Review. Sensors, 16.","DOI":"10.3390\/s16081169"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.jinf.2017.10.005","article-title":"Field Evaluation of an Infectious Disease\/Fever Screening Radar System During the 2017 Dengue Fever Outbreak in Hanoi, Vietnam","volume":"75","author":"Sun","year":"2017","journal-title":"J. Infect."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"e142","DOI":"10.1016\/j.jinf.2020.06.002","article-title":"A Pneumonia Screening System based on Parasympathetic Activity Monitoring in Non-contact Way using Compact Radars Beneath the Bed Mattress","volume":"81","author":"Matsui","year":"2020","journal-title":"J. Infect."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"102361","DOI":"10.1016\/j.bspc.2020.102361","article-title":"Short Time Cardio-vascular Pulses Estimation for Dengue Fever Screening via Continuous-Wave Doppler Radar using Empirical Mode Decomposition and Continuous Wavelet Transform","volume":"65","author":"Chinh","year":"2021","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Yang, X., Ishibashi, K., Hoi, L., Vu, T.N., Van, K.N., and Sun, G. (2018, January 18\u201321). Dengue Fever Detecting System Using Peak-detection of Data from Contactless Doppler Radar. Proceedings of the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA.","DOI":"10.1109\/EMBC.2018.8512355"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1016\/j.burns.2008.01.009","article-title":"Assessment of burn depth and burn wound healing potential","volume":"34","author":"Monstrey","year":"2008","journal-title":"Burns"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1109\/TIM.2016.2620778","article-title":"Millimeter Wave Reflectometry and Imaging for Noninvasive Diagnosis of Skin Burn Injuries","volume":"66","author":"Gao","year":"2017","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"4031","DOI":"10.1109\/TMTT.2019.2934413","article-title":"Inattentive Driving Behavior Detection Based on Portable FMCW Radar","volume":"67","author":"Ding","year":"2019","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1109\/TMTT.2019.2948844","article-title":"Doppler Cardiogram: A Remote Detection of Human Heart Activities","volume":"68","author":"Dong","year":"2020","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"130551","DOI":"10.1109\/ACCESS.2020.3009266","article-title":"ECG Signal Reconstruction via Doppler Sensor by Hybrid Deep Learning Model with CNN and LSTM","volume":"8","author":"Yamamoto","year":"2020","journal-title":"IEEE Access"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"4678","DOI":"10.1109\/TMTT.2013.2288226","article-title":"A Hybrid Radar-Camera Sensing System with Phase Compensation for Random Body Movement Cancellation in Doppler Vital Sign Detection","volume":"61","author":"Gu","year":"2013","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1897","DOI":"10.1109\/JSEN.2013.2238376","article-title":"Cancellation of Unwanted Doppler Radar Sensor Motion Using Empirical Mode Decomposition","volume":"13","author":"Mostafanezhad","year":"2013","journal-title":"IEEE Sens."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"3143","DOI":"10.1109\/TMTT.2008.2007139","article-title":"Random body movement cancellation in Doppler radar vital sign detection","volume":"56","author":"Li","year":"2008","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1109\/TIM.2015.2479103","article-title":"Fast acquisition of heart rate in noncontact vital sign radar measurement using time-window-variation technique","volume":"65","author":"Tu","year":"2016","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"158284","DOI":"10.1109\/ACCESS.2019.2950347","article-title":"Intermodulation-based nonlinear smart health sensing of human vital signs and location","volume":"7","author":"Mishra","year":"2019","journal-title":"IEEE Access"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"74721","DOI":"10.1109\/ACCESS.2019.2921240","article-title":"High-Accuracy Real-Time Monitoring of HeartRate Variability Using 24 GHz Continuous-WaveDoppler Radar","volume":"7","author":"Petrovic","year":"2019","journal-title":"IEEE Access"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1109\/JERM.2019.2923673","article-title":"A Supervised Machine Learning Algorithm for Heart-rate Detection using Doppler Motion-sensing radar","volume":"4","author":"Saluja","year":"2020","journal-title":"IEEE J. Electromagn. RF Microw. Med. Biol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"4261","DOI":"10.1109\/TMTT.2018.2852625","article-title":"Doppler Vital Signs Detection in the Presence of Large-Scale Random Body Movements","volume":"66","author":"Lv","year":"2018","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1587\/transcom.2018HMP0007","article-title":"Non-Contact Instantaneous Heart Rate Extraction System Using 24-GHz Microwave Doppler Sensor","volume":"E102.B","author":"Izumi","year":"2019","journal-title":"IEICE Trans. Commun."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1587\/elex.17.20200062","article-title":"Accurate Doppler Radar-Based Heart Rate Measurement Using Matched Filter","volume":"17","author":"Yang","year":"2020","journal-title":"IEICE Electron. Express"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Golyandina, N.E., and Zhigljavsky, A. (2013). Singular Spectrum Analysis for Time Series, Springer. Available online: https:\/\/www.springer.com\/gp\/book\/9783642349133.","DOI":"10.1007\/978-3-642-34913-3"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Massagram, W., Hafner, N.M., Park, B., Lubecke, V.M., Host-Madsen, A., and Boric-Lubecke, O. (2007, January 22\u201326). Feasibility of Heart Rate Variability Measurement from Quadrature Doppler Radar Using Arctangent Demodulation with DC Offset Compensation. Proceedings of the 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Lyon, France.","DOI":"10.1109\/IEMBS.2007.4352622"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1109\/TMTT.2007.895653","article-title":"Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems","volume":"55","author":"Park","year":"2007","journal-title":"IEEE Trans Microw. Theory Tech."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1109\/10.126604","article-title":"Neural-network-based adaptive matched filtering for QRS detection","volume":"39","author":"Xue","year":"1992","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1109\/TITB.2008.2007201","article-title":"A modified matched filter with double-sided thresholding for screening proliferative diabetic retinopathy","volume":"13","author":"Zhang","year":"2009","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1016\/j.compbiomed.2010.02.008","article-title":"Retinal vessel extraction by matched filter with first-order derivative of Gaussian","volume":"40","author":"Zhanga","year":"2010","journal-title":"Comput. Biol. Med."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1109\/TIM.2013.2277530","article-title":"Non contact distance and amplitude-independent vibration measurement based on an extended DACM algorithm","volume":"63","author":"Wang","year":"2014","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1644","DOI":"10.1109\/TMTT.2017.2772782","article-title":"Polyphase-basis discrete cosine transform for real-time measurement of heart rate with CW Doppler radar","volume":"66","author":"Park","year":"2018","journal-title":"IEEE Trans. Microw. Theory Techn."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1109\/TMTT.2017.2721407","article-title":"High-accuracy heart rate variability monitoring using Doppler radar based on Gaussian pulse train modeling and FTPR algorithm","volume":"66","author":"Nosrati","year":"2018","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"H899","DOI":"10.1152\/ajpheart.00230.2014","article-title":"An integrated mathematical model of the human cardiopulmonary system: Model development","volume":"310","author":"Albanese","year":"2016","journal-title":"Am. J. Physiol. Heart Circ. Physiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/11\/3588\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:05:38Z","timestamp":1760162738000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/11\/3588"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,21]]},"references-count":38,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2021,6]]}},"alternative-id":["s21113588"],"URL":"https:\/\/doi.org\/10.3390\/s21113588","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,21]]}}}