{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T07:39:16Z","timestamp":1781077156866,"version":"3.54.1"},"reference-count":127,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2021,6,17]],"date-time":"2021-06-17T00:00:00Z","timestamp":1623888000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"CoE project","award":["51235"],"award-info":[{"award-number":["51235"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The continuous and long-term measurement and monitoring of physiological signals such as electrocardiography (ECG) are very important for the early detection and treatment of heart disorders at an early stage prior to a serious condition occurring. The increasing demand for the continuous monitoring of the ECG signal needs the rapid development of wearable electronic technology. During wearable ECG monitoring, the electrodes are the main components that affect the signal quality and comfort of the user. This review assesses the application of textile electrodes for ECG monitoring from the fundamentals to the latest developments and prospects for their future fate. The fabrication techniques of textile electrodes and their performance in terms of skin\u2013electrode contact impedance, motion artifacts and signal quality are also reviewed and discussed. Textile electrodes can be fabricated by integrating thin metal fiber during the manufacturing stage of textile products or by coating textiles with conductive materials like metal inks, carbon materials, or conductive polymers. The review also discusses how textile electrodes for ECG function via direct skin contact or via a non-contact capacitive coupling. Finally, the current intensive and promising research towards finding textile-based ECG electrodes with better comfort and signal quality in the fields of textile, material, medical and electrical engineering are presented as a perspective.<\/jats:p>","DOI":"10.3390\/s21124174","type":"journal-article","created":{"date-parts":[[2021,6,17]],"date-time":"2021-06-17T21:29:16Z","timestamp":1623965356000},"page":"4174","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":135,"title":["Wearable Smart Textiles for Long-Term Electrocardiography Monitoring\u2014A Review"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4597-1615","authenticated-orcid":false,"given":"Abreha Bayrau","family":"Nigusse","sequence":"first","affiliation":[{"name":"Department of Materials, Textiles and Chemical Engineering, Ghent University, 9000 Gent, Belgium"},{"name":"Ethiopian Institute of Textile and Fashion Technology, Bahir Dar University, Bahir Dar 6000, Ethiopia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3270-5123","authenticated-orcid":false,"given":"Desalegn Alemu","family":"Mengistie","sequence":"additional","affiliation":[{"name":"Ethiopian Institute of Textile and Fashion Technology, Bahir Dar University, Bahir Dar 6000, Ethiopia"},{"name":"Materials Engineering Department, California Polytechnic State University, San Luis Obispo, CA 93407, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8383-8068","authenticated-orcid":false,"given":"Benny","family":"Malengier","sequence":"additional","affiliation":[{"name":"Department of Materials, Textiles and Chemical Engineering, Ghent University, 9000 Gent, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2167-7032","authenticated-orcid":false,"given":"Granch Berhe","family":"Tseghai","sequence":"additional","affiliation":[{"name":"Department of Materials, Textiles and Chemical Engineering, Ghent University, 9000 Gent, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lieva Van","family":"Langenhove","sequence":"additional","affiliation":[{"name":"Department of Materials, Textiles and Chemical Engineering, Ghent University, 9000 Gent, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,6,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Tao, X. (2001). Smart technology for textiles and clothing\u2014Introduction and overview. Smart Fibres, Fabrics and Clothing, Woodhead Publishing.","DOI":"10.1533\/9781855737600"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Koncar, V. (2016). Introduction to smart textiles and their applications. Smart Textiles and Their Applications, Woodhead Publishing.","DOI":"10.1016\/B978-0-08-100574-3.00001-1"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"11957","DOI":"10.3390\/s140711957","article-title":"Wearable Electronics and Smart Textiles: A Critical Review","volume":"14","author":"Stoppa","year":"2014","journal-title":"Sensors"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.snb.2009.04.040","article-title":"Wireless Sensor Network Based Wearable Smart Shirt for Ubiquitous Health and Activity Monitoring","volume":"140","author":"Lee","year":"2009","journal-title":"Sens. Actuators B Chem."},{"key":"ref_5","unstructured":"Wang, Y., Deepu, C.J., and Lian, Y. (September, January 30). A Computationally Efficient QRS Detection Algorithm for Wearable ECG Sensors. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, Boston, MA, USA."},{"key":"ref_6","first-page":"1","article-title":"Smart Textiles\u2014New Possibilities in Textile Engineering","volume":"1","author":"Das","year":"2014","journal-title":"IOSR J. Polym. Text. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.compind.2017.06.004","article-title":"A Wearable H-Shirt for Exercise ECG Monitoring and Individual Lactate Threshold Computing","volume":"92","author":"Sun","year":"2017","journal-title":"Comput. Ind."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1743-0003-9-21","article-title":"A Review of Wearable Sensors and Systems with Application in Rehabilitation","volume":"9","author":"Patel","year":"2012","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1111\/j.1747-1567.2008.00317.x","article-title":"Smart Textiles for Automotive: Application to Airbag Development","volume":"32","author":"Drean","year":"2008","journal-title":"Exp. Tech."},{"key":"ref_10","unstructured":"Scataglini, S., Andreoni, G., and Gallant, J. Smart Clothing Design Issues in Military Applications. Proceedings of the International Conference on Applied Human Factors and Ergonomics."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1800008","DOI":"10.1002\/admt.201800008","article-title":"Survey on Textile Electrode Technologies for Electrocardiographic (ECG) Monitoring, from Metal Wires to Polymers","volume":"3","author":"Pani","year":"2018","journal-title":"Adv. Mater. Technol."},{"key":"ref_12","first-page":"1","article-title":"An Upper Body Garment with Integrated Sensors for People with Neurological Disorders\u2014Early Development and Evaluation","volume":"3","author":"Murphy","year":"2019","journal-title":"BMC Biomed. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Pola, T., and Vanhala, J. (2007, January 3\u20136). Textile Electrodes in ECG Measurement. Proceedings of the IEEE 2007 3rd International Conference on Intelligent Sensors, Sensor Networks and Information, Melbourne, Australia.","DOI":"10.1109\/ISSNIP.2007.4496917"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"16907","DOI":"10.3390\/s121216907","article-title":"Textile Electrodes for EEG Recording\u2014A Pilot Study","volume":"12","author":"Seoane","year":"2012","journal-title":"Sensors"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Shafti, A., Manero, R.B.R., Borg, A.M., Althoefer, K., and Howard, M.J. (2016, January 16\u201321). Designing Embroidered Electrodes for Wearable Surface Electromyography. Proceedings of the IEEE International Conference on Robotics and Automation (ICRA), Stockholm, Sweden.","DOI":"10.1109\/ICRA.2016.7487131"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"7934","DOI":"10.3390\/s100907934","article-title":"Flexible Temperature Sensors on Fibers","volume":"10","author":"Sibinski","year":"2010","journal-title":"Sensors"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3245","DOI":"10.1109\/JSEN.2014.2327991","article-title":"Simplified Structural Textile Respiration Sensor Based on Capacitive Pressure Sensing Method","volume":"14","author":"Min","year":"2014","journal-title":"IEEE Sens. J."},{"key":"ref_18","first-page":"105","article-title":"A Wearable Healthcare System: New Frontier on e-Textile","volume":"4","author":"Paradiso","year":"2005","journal-title":"J. Telecommun. Inf. Technol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.1109\/JSEN.2010.2046634","article-title":"A Wearable Sensor for Measuring Sweat Rate","volume":"10","author":"Salvo","year":"2010","journal-title":"IEEE Sens. J."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Lee, J.W., and Yun, K.S. (2017). ECG Monitoring Garment Using Conductive Carbon Paste for Reduced Motion Artifacts. Polymers, 9.","DOI":"10.3390\/polym9090439"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1108\/SR-06-2017-0110","article-title":"Wearable Sensors for ECG Measurement: A Review","volume":"38","author":"Ramasamy","year":"2018","journal-title":"Sens. Rev."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Penhaker, M., Polomik, J., Kubicek, J., and Kasik, V. (2017, January 21\u201323). Biopotential Conducting Polymer Electrodes Design and Realization for ECG Measurement. Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017), Porto, Portugal.","DOI":"10.5220\/0006150801340141"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Takamatsu, S., Lonjaret, T., Crisp, D., and Badier, J. (2015). Direct Patterning of Organic Conductors on Knitted Textiles for Long-Term Electrocardiography. Nat. Publ. Group, 1\u20137.","DOI":"10.1038\/srep15003"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Ankhili, A., Tao, X., Cochrane, C., Coulon, D., and Koncar, V. (2018). Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring. Materials, 11.","DOI":"10.3390\/ma11020256"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Lou, C., Li, R., Li, Z., Liang, T., Wei, Z., Run, M., Yan, X., and Liu, X. (2016). Flexible Graphene Electrodes for Prolonged Dynamic ECG Monitoring. Sensors, 16.","DOI":"10.3390\/s16111833"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1109\/MCOM.2012.6122530","article-title":"A Wireless Wearable ECG Sensor for Long-Term Applications","volume":"50","author":"Nemati","year":"2012","journal-title":"IEEE Commun. Mag."},{"key":"ref_27","unstructured":"Webster, J.G. (2010). Biopotential electrodes. Medical Instrumentation Application and Design, John Wiley & Sons."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Iaizzo, P.A. (2005). Roberts Anatomy of the Human Heart. Handbook of Cardiac Anatomy, Physiology, and Devices, Humana Press Inc.","DOI":"10.1007\/978-1-59259-835-9"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Taji, B., Shirmohammadi, S., Groza, V., and Bolic, M. (2013, January 4\u20135). An ECG Monitoring System Using Conductive Fabric. Proceedings of the 2013 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Gatineau, QC, Canada.","DOI":"10.1109\/MeMeA.2013.6549758"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"173","DOI":"10.3390\/electronics4010173","article-title":"E-Textiles in Clinical Rehabilitation: A Scoping Review","volume":"4","author":"Fleury","year":"2015","journal-title":"Electronics"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2530","DOI":"10.1109\/TIM.2010.2057652","article-title":"A Smart ECG Measurement System Based on Web-Service-Oriented Architecture for Telemedicine Applications","volume":"59","author":"Meduri","year":"2010","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Hadjem, M., Salem, O., and Nait-Abdesselam, F. (2014, January 15\u201318). An ECG Monitoring System for Prediction of Cardiac Anomalies Using WBAN. Proceedings of the 2014 IEEE 16th International Conference on e-Health Networking, Applications and Services (Healthcom), Natal, Brazil.","DOI":"10.1109\/HealthCom.2014.7001883"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Yu, Y., Zhang, J., and Liu, J. (2013). Biomedical Implementation of Liquid Metal Ink as Drawable ECG Electrode and Skin Circuit. PLoS ONE, 8.","DOI":"10.1371\/journal.pone.0058771"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1109\/JSEN.2011.2114649","article-title":"A Novel Dry Active Biosignal Electrode Based on an Hybrid Organic-Inorganic Interface Material","volume":"11","author":"Ribeiro","year":"2011","journal-title":"IEEE Sens. J."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Dupre, A., Sarah Vincent, S., and Paul, A. (2005). Iaizzo Basic ECG theory, Recordings, and interpretation. Handbook of Cardiac Anatomy, Physiology, and Devices, Humana Press.","DOI":"10.1007\/978-1-59259-835-9_15"},{"key":"ref_36","unstructured":"Gonzales, L., Walker, K., Keller, K., Beckman, D., Goodell, H., Wright, G., Rhone, C., Emery, A., Wright, G., and Rhone, C. (October, January 15). Textile Sensor System for Electrocardiogram Monitoring. Proceedings of the IEEE Virtual Conference on Applications of Commercial Sensors (VCACS), Raleigh, NC, USA."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1088\/0967-3334\/31\/2\/009","article-title":"Characterization of Textile Electrodes and Conductors Using Standardized Measurement Setups","volume":"31","author":"Beckmann","year":"2010","journal-title":"Physiol. Meas."},{"key":"ref_38","unstructured":"Taji, B. (2013). Reconstruction of ECG Signals Acquired with Conductive Textile Electrodes, University of Ottawa."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Yapici, M.K., and Alkhidir, T.E. (2017). Intelligent Medical Garments with Graphene-Functionalized Smart-Cloth ECG Sensors. Sensors, 17.","DOI":"10.3390\/s17040875"},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Khairuddin, A.M., Ku Azir, K.N.F., and Eh Kan, P. (2018). Design and Development of Intelligent Electrodes for Future Digital Health Monitoring: A Review. IOP Conf. Ser. Mater. Sci. Eng., 318.","DOI":"10.1088\/1757-899X\/318\/1\/012073"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1080\/00405160802597479","article-title":"Textile-Structured Electrodes for Electrocardiogram","volume":"40","author":"Xu","year":"2008","journal-title":"Text. Prog."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Abu-Saude, M., and Morshed, B.I. (2018). Characterization of a Novel Polypyrrole (PPy) Conductive Polymer Coated Patterned Vertical CNT (PvCNT) Dry ECG Electrode. Chemosensors, 6.","DOI":"10.3390\/chemosensors6030027"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"11465","DOI":"10.3390\/s150511465","article-title":"A Wearable Context-Aware ECG Monitoring System Integrated with Built-in Kinematic Sensors of the Smartphone","volume":"15","author":"Miao","year":"2015","journal-title":"Sensors"},{"key":"ref_44","first-page":"1","article-title":"Design and Development of Textile Electrodes for EEG Measurement Using Copper Plated Polyester Fabrics","volume":"8","author":"Kumar","year":"2018","journal-title":"J. Text. Appar. Technol. Manag."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1109\/TITB.2009.2012408","article-title":"Fabric-Based Active Electrode Design and Fabrication for Health Monitoring Clothing","volume":"13","author":"Merritt","year":"2009","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"R47","DOI":"10.1088\/0967-3334\/34\/9\/R47","article-title":"Dry Electrodes for Electrocardiography","volume":"34","author":"Meziane","year":"2013","journal-title":"Physiol. Meas."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Albulbul, A. (2016). Evaluating Major Electrode Types for Idle Biological Signal Measurements for Modern Medical Technology. Bioengineering, 3.","DOI":"10.3390\/bioengineering3030020"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Liu, Y., Li, X., and Lu, J.C. (2013). Electrically Conductive Poly (3, 4-Ethylenedioxythiophene)\u2013Polystyrene Sulfonic Acid\/Polyacrylonitrile Composite Fibers Prepared by Wet Spinning. J. Appl. Polym. Sci., 370\u2013374.","DOI":"10.1002\/app.39174"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1472","DOI":"10.1109\/TBME.2012.2190288","article-title":"CNT\/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring","volume":"59","author":"Jung","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"23758","DOI":"10.3390\/s141223758","article-title":"Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording","volume":"14","author":"Chen","year":"2014","journal-title":"Sensors"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1260\/2040-2295.1.4.535","article-title":"Design of an Integrated Sensor Platform for Vital Sign Monitoring of Newborn Infants at Neonatal Intensive Care Unit","volume":"1","author":"Chen","year":"2010","journal-title":"J. Healthc. Eng."},{"key":"ref_52","unstructured":"Lage, J., Catarino, A., Carvalho, H., and Rocha, A. (2015, January 21\u201326). Smart Shirt with Embedded Vital Sign and Moisture Sensing. Proceedings of the 1st International Conference on Smart Portable, Wearable, Implantable and Disability-Oriented Devices and Systems, Brussels, Belgium."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1080\/00405000903442086","article-title":"Textile Electrodes of Jacquard Woven Fabrics for Biosignal Measurement","volume":"101","author":"Song","year":"2010","journal-title":"J. Text. Inst."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"015003","DOI":"10.1088\/2631-8695\/ab63f3","article-title":"Designing and Investigation of Braided-Cum-Woven Structure for Wearable Heating Textile Designing and Investigation of Braided-Cum-Woven Structure for Wearable Heating Textile","volume":"2","author":"Pragya","year":"2020","journal-title":"Eng. Res. Express"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Liu, Y., Zhao, X., and Tuo, X. (2017). Preparation of Polypyrrole Coated Cotton Conductive Fabrics. J. Text. Inst., 5000.","DOI":"10.1080\/00405000.2016.1193981"},{"key":"ref_56","first-page":"57","article-title":"Electrical Conductive Textiles Obtained by Screen Printing","volume":"90","author":"Kazani","year":"2012","journal-title":"Fibres Text. East. Eur."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"2355","DOI":"10.1016\/j.arabjc.2013.08.013","article-title":"Fabricating Multifunctional Silver Nanoparticles-Coated Cotton Fabric","volume":"10","author":"Yazdanshenas","year":"2017","journal-title":"Arab. J. Chem."},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Tseghai, G.B., Mengistie, D.A., Malengier, B., Fante, K.A., and Langenhove, L.v. (2020). PEDOT: PSS-Based Conductive Textiles and Their Applications. Sensors, 20.","DOI":"10.3390\/s20071881"},{"key":"ref_59","first-page":"410","article-title":"Wearable Textile Electrodes for ECG Measurement","volume":"11","author":"Vojtech","year":"2013","journal-title":"Adv. Electr. Electron. Eng."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1177\/1528083718779427","article-title":"Fashionable Wrist Band Using Highly Conductive Fabric for Electrocardiogram Signal Monitoring","volume":"49","author":"Das","year":"2019","journal-title":"J. Ind. Text."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/978-3-540-70994-7_5","article-title":"Contactless EMG Sensors Embroidered onto Textile","volume":"Volume 13","author":"Leonhardt","year":"2007","journal-title":"Proceedings of the 4th International Workshop on Wearable and Implantable Body Sensor Networks (BSN 2007)"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/TSMCC.2009.2032660","article-title":"A Survey OnWearable Sensor-Based Systems for Health Monitoring and Prognosis","volume":"40","author":"Pantelopoulos","year":"2010","journal-title":"IEEE Trans. Syst. Man Cybern. Appl. Rev."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1016\/j.snb.2015.07.111","article-title":"Graphene-Clad Textile Electrodes for Electrocardiogram Monitoring","volume":"221","author":"Yapici","year":"2015","journal-title":"Sens. Actuators B Chem."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"2832","DOI":"10.1109\/JSEN.2016.2519392","article-title":"Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review","volume":"16","author":"Sun","year":"2016","journal-title":"IEEE Sens. J."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1007\/s12652-012-0153-8","article-title":"Textile-Based, Contactless ECG Monitoring for Non-ICU Clinical Settings","volume":"4","author":"Chamadiya","year":"2013","journal-title":"J. Ambient. Intell. Humaniz. Comput."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1177\/0142331215600254","article-title":"Textile-Based ECG Acquisition System with Capacitively Coupled Electrodes","volume":"39","author":"Li","year":"2017","journal-title":"Trans. Inst. Meas. Control."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"14732","DOI":"10.3390\/s140814732","article-title":"Flexible Capacitive Electrodes for Minimizing Motion Artifacts in Ambulatory Electrocardiograms","volume":"14","author":"Lee","year":"2014","journal-title":"Sensors"},{"key":"ref_68","doi-asserted-by":"crossref","unstructured":"Fuhrhop, S., Lamparth, S., and Heuer, S. (2009, January 26\u201328). A Textile Integrated Long-Term ECG Monitor with Capacitively Coupled Electrodes. Proceedings of the 2009 IEEE Biomedical Circuits and Systems Conference, Beijing, China.","DOI":"10.1109\/BIOCAS.2009.5372095"},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.measurement.2017.09.024","article-title":"Textile Electrodes in Capacitive Signal Sensing Applications","volume":"114","author":"Babusiak","year":"2018","journal-title":"Meas. J. Int. Meas. Confed."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1109\/TBME.2006.872823","article-title":"ECG Measurement on a Chair without Conductive Contact","volume":"53","author":"Lim","year":"2006","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"11295","DOI":"10.3390\/s150511295","article-title":"Heart Rate Variability Monitoring during Sleep Based on Capacitively Coupled Textile Electrodes on a Bed","volume":"15","author":"Lee","year":"2015","journal-title":"Sensors"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1088\/0967-3334\/35\/5\/895","article-title":"Oetomo Unobtrusive ECG Monitoring in the NICU Using a Capacitive Sensing Array","volume":"35","author":"Atallah","year":"2014","journal-title":"Physiol. Meas."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1088\/0967-3334\/36\/3\/513","article-title":"Simultaneous Comparison of 1 Gel with 4 Dry Electrode Types for Electrocardiography","volume":"36","author":"Meziane","year":"2015","journal-title":"Physiol. Meas."},{"key":"ref_74","doi-asserted-by":"crossref","unstructured":"Boehm, A., Yu, X., Neu, W., Leonhardt, S., and Teichmann, D. (2016). A Novel 12-Lead ECG T-Shirt with Active Electrodes. Electronics, 5.","DOI":"10.3390\/electronics5040075"},{"key":"ref_75","first-page":"12","article-title":"Smart Wheel Chair","volume":"Volume 6","author":"Gassara","year":"2017","journal-title":"Smart Textile Salon"},{"key":"ref_76","first-page":"7167","article-title":"MagIC System: A New Textile-Based Wearable Device for Biological Signal Monitoring. Applicability in Daily Life and Clinical Setting","volume":"7","author":"Rizzo","year":"2005","journal-title":"Annu. Int. Conf. IEEE Eng. Med. Biol. Proc."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1093\/europace\/eus368","article-title":"Evaluation of a Textile-Based Wearable System for the Electrocardiogram Monitoring in Cardiac Patients","volume":"15","author":"Racca","year":"2013","journal-title":"Europace"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"1900","DOI":"10.1109\/TIM.2018.2806950","article-title":"Effect of Pressure on Skin-Electrode Impedance in Wearable Biomedical Measurement Devices","volume":"67","author":"Taji","year":"2018","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_79","doi-asserted-by":"crossref","unstructured":"Takeshita, T., Yoshida, M., Takei, Y., Ouchi, A., and Hinoki, A. (2019). Relationship between Contact Pressure and Motion Artifacts in ECG Measurement with Electrostatic Flocked Electrodes Fabricated on Textile. Sci. Rep., 1\u201310.","DOI":"10.1038\/s41598-019-42027-x"},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"126","DOI":"10.31881\/TLR.2019.27","article-title":"Washable Embroidered Textile Electrodes for Long-Term Electrocardiography Monitoring","volume":"2","author":"Ankhili","year":"2019","journal-title":"TLR"},{"key":"ref_81","doi-asserted-by":"crossref","unstructured":"An, X., and Stylios, G.K. (2018). A Hybrid Textile Electrode for Electrocardiogram (ECG) Measurement and Motion Tracking. Materials, 11.","DOI":"10.3390\/ma11101887"},{"key":"ref_82","first-page":"1089","article-title":"Dry Electrode Sizes in Recording ECG and Heart Rate in Wearable Applications","volume":"Volume 65","author":"Joutsen","year":"2018","journal-title":"EMBEC & NBC 2017"},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1080\/00405000.2018.1508799","article-title":"Investigating the Performance of Dry Textile Electrodes for Wearable End-Uses","volume":"110","author":"An","year":"2019","journal-title":"J. Text. Inst."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"110","DOI":"10.4236\/jtst.2015.13012","article-title":"Progress on Fabric Electrodes Used in ECG Signals Monitoring","volume":"1","author":"Liu","year":"2015","journal-title":"J. Text. Sci. Technol."},{"key":"ref_85","doi-asserted-by":"crossref","unstructured":"Inoue, M., Tada, Y., Muta, H., Hayashi, Y., and Tokumaru, T. (2012). Development of Highly Conductive Inks for Smart Textiles. IEEE Sens. J., 1\u20134.","DOI":"10.1109\/EMAP.2012.6507896"},{"key":"ref_86","doi-asserted-by":"crossref","unstructured":"Tong, W., Kan, C., Yang, H., and Member, S. (2018, January 4\u20137). Sensitivity Analysis of Wearable Textiles for ECG Sensing. Proceedings of the IEEE EMBS International Conference on Biomedical & Health Informatics (BHI), Las Vegas, NV, USA.","DOI":"10.1109\/BHI.2018.8333393"},{"key":"ref_87","doi-asserted-by":"crossref","unstructured":"Nigusse, A.B., Malengier, B., Mengistie, D.A., Tseghai, G.B., and Langenhove, L.v. (2020). Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring. Sensors, 20.","DOI":"10.3390\/s20216233"},{"key":"ref_88","doi-asserted-by":"crossref","unstructured":"Arquilla, K., Webb, A.K., and Allison, P. (2020). Anderson Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring. Sensors, 20.","DOI":"10.3390\/s20041013"},{"key":"ref_89","doi-asserted-by":"crossref","unstructured":"Huang, X., Dai, B., Ren, Y., Xu, J., and Zhu, P. (2015). Preparation and Study of Electromagnetic Interference Shielding Materials Comprised of Ni-Co Coated on Web-like Biocarbon Nanofibers via Electroless Deposition. J. Nanomater., 2015.","DOI":"10.1155\/2015\/320306"},{"key":"ref_90","doi-asserted-by":"crossref","unstructured":"Gamage, S.J.P., Yang, K., Braveenth, R., Raagulan, K., Kim, H.S., Lee, Y.S., Yang, C.M., Moon, J.J., and Chai, K.Y. (2017). MWCNT Coated Free-Standing Carbon Fiber Fabric for Enhanced Performance in EMI Shielding with a Higher Absolute EMI SE. Materials, 10.","DOI":"10.3390\/ma10121350"},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.sbsr.2018.05.001","article-title":"Development of Printed and Flexible Dry ECG Electrodes","volume":"20","author":"Chlaihawi","year":"2018","journal-title":"Sens. Bio Sens. Res."},{"key":"ref_92","doi-asserted-by":"crossref","unstructured":"Ankhili, A., Tao, X., Cochrane, C., Koncar, V., Coulon, D., and Tarlet, J.-M. (2019). Ambulatory Evaluation of ECG Signals Obtained Using Washable Textile-Based Electrodes Made with Chemically Modified PEDOT:PSS. Sensors, 19.","DOI":"10.3390\/s19020416"},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.synthmet.2015.09.024","article-title":"High Electrical Conductance Poly(3,4-Ethylenedioxythiophene) Coatings on Textile for Electrocardiogram Monitoring","volume":"210","author":"Trindade","year":"2015","journal-title":"Synth. Met."},{"key":"ref_94","first-page":"179","article-title":"Some Significant Trends in Conductive Textiles","volume":"2","author":"Gokarneshan","year":"2018","journal-title":"Latest Trends Text. Fash. Des."},{"key":"ref_95","doi-asserted-by":"crossref","unstructured":"Wattal, S., Spear, S.K., Imtiaz, M.H., and Sazonov, E. (2018, January 4\u20137). A Polypyrrole-Coated Textile Electrode and Connector for Wearable ECG Monitoring. Proceedings of the 2018 IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN), Las Vegas, NV, USA.","DOI":"10.1109\/BSN.2018.8329657"},{"key":"ref_96","first-page":"1","article-title":"Electrical Performance of PEDOT: PSS-Based Textile Electrodes for Wearable ECG Monitoring: A Comparative Study","volume":"17","year":"2018","journal-title":"Bio Med. Eng. Online"},{"key":"ref_97","first-page":"1","article-title":"Characterization of Screen-Printed Textile Electrodes Based on Conductive Polymer for ECG Acquisition","volume":"44","author":"Achilli","year":"2017","journal-title":"Comput. Cardiol."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"37524","DOI":"10.1021\/acsami.7b09954","article-title":"Screen-Printed PEDOT:PSS Electrodes on Commercial Finished Textiles for Electrocardiography","volume":"9","author":"Sinha","year":"2017","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"4097","DOI":"10.1109\/JSEN.2018.2819202","article-title":"Design and Characterization of Screen-Printed Textile Electrodes for ECG Monitoring","volume":"18","author":"Achilli","year":"2018","journal-title":"IEEE Sens. J."},{"key":"ref_100","doi-asserted-by":"crossref","unstructured":"Pani, D., Achilli, A., Bassareo, P.P., Cugusi, L., Mercuro, G., Fraboni, B., and Bonfiglio, A. (2016, January 11\u201314). Fully-Textile Polymer-Based ECG Electrodes: Overcoming the Limits of Metal-Based Textiles. Proceedings of the Computing in Cardiology 2016, Vancouver, BC, Canada.","DOI":"10.22489\/CinC.2016.109-460"},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1109\/TBME.2015.2465936","article-title":"Fully Textile, PEDOT:PSS Based Electrodes for Wearable ECG Monitoring Systems","volume":"63","author":"Pani","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"900","DOI":"10.1109\/JSYST.2013.2260620","article-title":"Development of a Wearable Mobile Electrocardiogram Monitoring System by Using Novel Dry Foam Electrodes","volume":"8","author":"Tseng","year":"2014","journal-title":"IEEE Syst. J."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"1750","DOI":"10.3390\/s150101750","article-title":"Embroidered Electrode with Silver\/Titanium Coating for Long-Term ECG Monitoring","volume":"15","author":"Weder","year":"2015","journal-title":"Sensors"},{"key":"ref_104","doi-asserted-by":"crossref","unstructured":"Ankhili, A., Tao, X., Cochrane, C., Koncar, V., Coulon, D., and Tarlet, J.M. (2018). Comparative Study on Conductive Knitted Fabric Electrodes for Long-Term Electrocardiography Monitoring: Silver-Plated and PEDOT:PSS Coated Fabrics. Sensors, 18.","DOI":"10.3390\/s18113890"},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"1412","DOI":"10.1109\/TIM.2013.2289072","article-title":"Impact of Skin-Electrode Interface on Electrocardiogram Measurements Using Conductive Textile Electrodes","volume":"63","author":"Taji","year":"2014","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"2260","DOI":"10.1007\/s12221-014-2260-y","article-title":"Fabrication of Conductive Fabric as Textile Electrode for ECG Monitoring","volume":"15","author":"Zhou","year":"2014","journal-title":"Fibers Polym."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.jelectrocard.2010.12.004","article-title":"A Comparison of Conductive Textile-Based and Silver\/Silver Chloride Gel Electrodes in Exercise Electrocardiogram Recordings","volume":"44","author":"Marozas","year":"2011","journal-title":"J. Electrocardiol."},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1109\/TBME.2015.2462312","article-title":"Fabric-Based Wearable Dry Electrodes for Body Surface Biopotential Recording","volume":"63","author":"Yokus","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1177\/1528083712438069","article-title":"Design and Development of Embroidered Textile Electrodes for Continuous Measurement of Electrocardiogram Signals","volume":"42","author":"Kannaian","year":"2013","journal-title":"J. Ind. Text."},{"key":"ref_110","doi-asserted-by":"crossref","unstructured":"Zhang, H., Tian, L., Lu, H., Zhou, M., Zou, H., Fang, P., Yao, F., and Li, G. (2017, January 11\u201315). A Wearable 12-Lead ECG Acquisition System with Fabric Electrodes. Proceedings of the 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Jeju, Korea.","DOI":"10.1109\/EMBC.2017.8037841"},{"key":"ref_111","doi-asserted-by":"crossref","unstructured":"Peltokangas, M., Verho, J., and Vehkaoja, A. (2011, January 5\u20137). Unobtrusive Night-Time EKG and HRV Monitoring System. Proceedings of the IEEE 2011 10th International Workshop on Biomedical Engineering, Kos, Greece.","DOI":"10.1109\/IWBE.2011.6079018"},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1016\/S0195-5616(98)50128-3","article-title":"Holter Monitoring and Cardiac Event Recording","volume":"28","author":"Goodwin","year":"1998","journal-title":"Vet. Clin. N. Am. Small Anim. Pract."},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"119","DOI":"10.21595\/jme.2018.20028","article-title":"An Approach to 24-Hour Electrocardiogram Monitoring in Sheep Experimental Model","volume":"6","author":"Kviesulaitis","year":"2018","journal-title":"J. Meas. Eng."},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"216","DOI":"10.12968\/vetn.2018.9.4.216","article-title":"How ECG Monitoring Contributes to Patient Care","volume":"9","author":"Pace","year":"2018","journal-title":"Vet. Nurse"},{"key":"ref_115","doi-asserted-by":"crossref","unstructured":"Reddy, B.S. (2015). Analysis of Base Apex Lead Electrocardiograms of Adult Buffaloes. JDVAR, 2.","DOI":"10.15406\/jdvar.2015.02.00058"},{"key":"ref_116","first-page":"331","article-title":"Electrocardiography in Horses\u2014Part 1: How to Make a Good Recording","volume":"7","author":"Verheyen","year":"2010","journal-title":"Vlaams Diergeneeskd. Tijdschr."},{"key":"ref_117","doi-asserted-by":"crossref","unstructured":"Guidi, A., Lanata, A., Baragli, P., Valenza, G., and Scilingo, E. (2016). A Wearable System for the Evaluation of the Human-Horse Interaction: A Preliminary Study. Electronics, 5.","DOI":"10.3390\/electronics5040063"},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.jveb.2016.10.001","article-title":"Validation of Smart Textile Electrodes for Electrocardiogram Monitoring in Free-Moving Horses","volume":"17","author":"Guidi","year":"2017","journal-title":"J. Vet. Behav."},{"key":"ref_119","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1111\/evj.13296","article-title":"Smart Textiles Biotechnology for Electrocardiogram Monitoring in Horses during Exercise on Treadmill: Validation Tests","volume":"53","author":"Felici","year":"2021","journal-title":"Equine Vet. J."},{"key":"ref_120","doi-asserted-by":"crossref","unstructured":"Lanata, A., Guidi, A., Baragli, P., Valenza, G., and Scilingo, E.P. (2015). A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0140783"},{"key":"ref_121","doi-asserted-by":"crossref","unstructured":"Kim, S., Leonhardt, S., Zimmermann, N., Kranen, P., Kensche, D., M\u00fcller, E., and Quix, C. (2008, January 1\u20133). Influence of Contact Pressure and Moisture on the Signal Quality of a Newly Developed Textile ECG Sensor Shirt. Proceedings of the 2008 5th International Summer School and Symposium on Medical Devices and Biosensors, Hong Kong, China.","DOI":"10.1109\/ISSMDBS.2008.4575068"},{"key":"ref_122","doi-asserted-by":"crossref","unstructured":"Pani, D., Dessi, A., Gusai, E., Saenz-Cogollo, J.F., Barabino, G., Fraboni, B., and Bonfiglio, A. (2015, January 25\u201329). Evaluation of Novel Textile Electrodes for ECG Signals Monitoring Based on PEDOT:PSS-Treated Woven Fabrics. Proceedings of the IEEE 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy.","DOI":"10.1109\/EMBC.2015.7319072"},{"key":"ref_123","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2017\/7539840","article-title":"Performance Evaluation of Plain Weave and Honeycomb Weave Electrodes for Human ECG Monitoring","volume":"2017","author":"Xiao","year":"2017","journal-title":"J. Sens."},{"key":"ref_124","doi-asserted-by":"crossref","unstructured":"Fontana, P., Rebeca, N., Camenzind, M., Boesch, M., Baty, F., Schoch, O.D., Brutsche, M.H., Rossi, R.M., and Annaheim, S. (2019). Applicability of a Textile ECG-Belt for Unattended Sleep Apnoea Monitoring in a Home Setting. Sensors, 19.","DOI":"10.3390\/s19153367"},{"key":"ref_125","doi-asserted-by":"crossref","unstructured":"Yoo, J., and Yoo, H. (September, January 30). Fabric Circuit Board-Based Dry Electrode and Its Characteristics for Long-Term Physiological Signal Recording. Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA.","DOI":"10.1109\/IEMBS.2011.6090692"},{"key":"ref_126","doi-asserted-by":"crossref","unstructured":"Taji, B., Shirmohammadi, S., and Groza, V. (2014, January 12\u201315). Measuring Skin-Electrode Impedance Variation of Conductive Textile Electrodes under Pressure. Proceedings of the 2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings, Montevideo, Uruguay.","DOI":"10.1109\/I2MTC.2014.6860909"},{"key":"ref_127","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1007\/s00380-019-01347-8","article-title":"Validation of Wearable Textile Electrodes for ECG Monitoring","volume":"34","author":"Tetsuou","year":"2019","journal-title":"Heart Vessel."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/12\/4174\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:17:56Z","timestamp":1760163476000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/12\/4174"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,17]]},"references-count":127,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2021,6]]}},"alternative-id":["s21124174"],"URL":"https:\/\/doi.org\/10.3390\/s21124174","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,17]]}}}