{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T19:40:47Z","timestamp":1783626047492,"version":"3.55.0"},"reference-count":34,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2021,6,27]],"date-time":"2021-06-27T00:00:00Z","timestamp":1624752000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001352","name":"National University of Singapore","doi-asserted-by":"publisher","award":["R-296-000-233-133"],"award-info":[{"award-number":["R-296-000-233-133"]}],"id":[{"id":"10.13039\/501100001352","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Mechanical ventilation comprises a significant proportion of the total energy consumed in buildings. Sufficient natural ventilation in buildings is critical in reducing the energy consumption of mechanical ventilation while maintaining a comfortable indoor environment for occupants. In this paper, a new computerized framework based on building information modelling (BIM) and machine learning data-driven models is presented to analyze the optimum thermal comfort for indoor environments with the effect of natural ventilation. BIM provides geometrical and semantic information of the built environment, which are leveraged for setting the computational domain and boundary conditions of computational fluid dynamics (CFD) simulation. CFD modelling is conducted to obtain the flow field and temperature distribution, the results of which determine the thermal comfort index in a ventilated environment. BIM\u2013CFD provides spatial data, boundary conditions, indoor environmental parameters, and the thermal comfort index for machine learning to construct robust data-driven models to empower the predictive analysis. In the neural network, the adjacency matrix in the field of graph theory is used to represent the spatial features (such as zone adjacency and connectivity) and incorporate the potential impact of interzonal airflow in thermal comfort analysis. The results of a case study indicate that utilizing natural ventilation can save cooling power consumption, but it may not be sufficient to fulfil all the thermal comfort criteria. The performance of natural ventilation at different seasons should be considered to identify the period when both air conditioning energy use and indoor thermal comfort are achieved. With the proposed new framework, thermal comfort prediction can be examined more efficiently to study different design options, operating scenarios, and changeover strategies between various ventilation modes, such as better spatial HVAC system designs, specific room-based real-time HVAC control, and other potential applications to maximize indoor thermal comfort.<\/jats:p>","DOI":"10.3390\/s21134401","type":"journal-article","created":{"date-parts":[[2021,6,27]],"date-time":"2021-06-27T23:57:22Z","timestamp":1624838242000},"page":"4401","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":58,"title":["BIM and Data-Driven Predictive Analysis of Optimum Thermal Comfort for Indoor Environment"],"prefix":"10.3390","volume":"21","author":[{"given":"Vincent J.L.","family":"Gan","sequence":"first","affiliation":[{"name":"School of Design and Environment, National University of Singapore, Singapore 117566, Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Han","family":"Luo","sequence":"additional","affiliation":[{"name":"Department of Civil and Environmental Engineering, Hong Kong University of Science and Technology, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Tan","sequence":"additional","affiliation":[{"name":"Sino-Australia Joint Research Centre in BIM and Smart Construction, Shenzhen University, Shenzhen 518060, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Deng","sequence":"additional","affiliation":[{"name":"Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI 48109, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7179-9281","authenticated-orcid":false,"given":"H.L.","family":"Kwok","sequence":"additional","affiliation":[{"name":"Department of Civil and Environmental Engineering, Hong Kong University of Science and Technology, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,6,27]]},"reference":[{"key":"ref_1","unstructured":"UNEP (2009). Buildings and Climate Change\u2014Summary for Decision Makers, United Nations Environment Programme (UNEP)."},{"key":"ref_2","unstructured":"HKEPD (2012). Greenhouse Gas Emission in Hong Kong by Sector."},{"key":"ref_3","unstructured":"EMSD (2014). Hong Kong Energy End-Use Data."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1016\/j.buildenv.2004.08.019","article-title":"Wind-induced pressure at external surfaces of a high-rise residential building in Hong Kong","volume":"40","author":"Burnett","year":"2005","journal-title":"Build. Environ."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1177\/1420326X09358021","article-title":"Energy saving by utilizing natural ventilation in public housing in Hong Kong","volume":"19","author":"Yik","year":"2010","journal-title":"Indoor Built Environ."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.enbuild.2008.08.005","article-title":"A comparative analysis of urban and rural residential thermal comfort under natural ventilation environment","volume":"41","author":"Han","year":"2009","journal-title":"Energy Build."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/S0378-7788(00)00087-6","article-title":"Thermal comfort: Use of controls in naturally ventilated buildings","volume":"33","author":"Raja","year":"2001","journal-title":"Energy Build."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/j.buildenv.2012.09.008","article-title":"Thermal comfort in outdoor urban spaces in Singapore","volume":"59","author":"Wei","year":"2013","journal-title":"Build. Environ."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1490","DOI":"10.1016\/j.buildenv.2009.12.013","article-title":"Adaptive use of natural ventilation for thermal comfort in Indian apartments","volume":"45","author":"Indraganti","year":"2010","journal-title":"Build. Environ."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1016\/j.proeng.2015.09.073","article-title":"The Improvement of Ventilation Design in School Buildings Using CFD Simulation","volume":"121","author":"Song","year":"2015","journal-title":"Procedia Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.proche.2013.03.012","article-title":"Ventilation control using computational fluid-dynamics (CFD) modelling for cultural buildings conservation","volume":"8","author":"Congedo","year":"2013","journal-title":"Procedia Chem."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.buildenv.2017.10.019","article-title":"Development of an adaptive discharge coefficient to improve the accuracy of cross-ventilation airflow calculation in building energy simulation tools","volume":"127","author":"Shirzadi","year":"2018","journal-title":"Build. Environ."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.scs.2017.11.020","article-title":"Improving the CFD modelling of cross-ventilation in highly-packed urban areas","volume":"37","author":"Shirzadi","year":"2018","journal-title":"Sustain. Cities Soc."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/j.enbuild.2016.09.053","article-title":"Cross-ventilation of a room in a courtyard building","volume":"133","author":"Micallef","year":"2016","journal-title":"Energy Build."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.buildenv.2014.05.007","article-title":"CFD modeling and moisture dynamics implications of ventilation scenarios in historical buildings","volume":"79","author":"Congedo","year":"2014","journal-title":"Build. and Environ."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1016\/j.proeng.2015.08.1036","article-title":"Study on Natural Ventilation Design Optimization Based on CFD Simulation for Green Buildings","volume":"121","author":"Guo","year":"2015","journal-title":"Procedia Eng."},{"key":"ref_17","first-page":"106615","article-title":"Machine learning driven personal comfort prediction by wearable sensing of pulse rate and skin temperature","volume":"170C","author":"Chaudhuri","year":"2019","journal-title":"Build. Environ."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.buildenv.2017.08.033","article-title":"Improvement of the performance of a simple box model using CFD modeling to predict indoor air formaldehyde concentration","volume":"124","author":"Mocho","year":"2017","journal-title":"Build. Environ."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.buildenv.2018.11.019","article-title":"Feature selection and Gaussian Process regression for personalized thermal comfort prediction","volume":"148","author":"Guenther","year":"2019","journal-title":"Build. Environ."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.buildenv.2018.01.023","article-title":"Personal comfort models\u2014A new paradigm in thermal comfort for occupant-centric environmental control","volume":"132","author":"Kim","year":"2018","journal-title":"Build. Environ."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.apr.2020.07.027","article-title":"IndoAirSense: A framework for indoor air quality estimation and forecasting","volume":"12","author":"Sharma","year":"2021","journal-title":"Atmos. Pollut. Res."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1007\/s12273-016-0271-x","article-title":"Predicting thermal and energy performance of mixed-mode ventilation using an integrated simulation approach","volume":"9","author":"Malkawi","year":"2016","journal-title":"Build. Simul."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Heibati, S., Maref, W., and Saber, H.H. (2019). Assessing the energy and indoor air quality performance for a three-story building using an integrated model, part one: The need for integration. Energies, 12.","DOI":"10.3390\/en12244775"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2230","DOI":"10.1016\/j.buildenv.2011.05.002","article-title":"Modeling ventilation rates in bedrooms based on building characteristics and occupant behavior","volume":"46","author":"Toftum","year":"2011","journal-title":"Build. Environ."},{"key":"ref_25","unstructured":"Eastman, C., Eastman, C.M., Teicholz, P., Sacks, R., and Liston, K. (2011). BIM Handbook: A Guide to Building Information Modeling for Owners, Managers, Designers, Engineers and Contractors, John Wiley & Sons."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Lee, S., and Song, D. (2010). Prediction and evaluation method of wind environment in the early design stage using BIM-based CFD simulation. IOP Conference Series: Materials Science and Engineering, IOP Publishing.","DOI":"10.1088\/1757-899X\/10\/1\/012035"},{"key":"ref_27","unstructured":"Pazhoohesh, M., Shahmir, R., and Zhang, C. (2015, January 2\u20134). Investigating thermal comfort and occupants position impacts on building sustainability using CFD and BIM. Proceedings of the 49th International Conference of the Architectural Science Association, Melbourne, Australia."},{"key":"ref_28","unstructured":"Bazjanac, V. (2008). IFC BIM-Based Methodology for Semi-Automated Building Energy Performance Simulation."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.autcon.2008.07.003","article-title":"Building information model based energy\/exergy performance assessment in early design stages","volume":"18","author":"Schlueter","year":"2009","journal-title":"Autom. Constr."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1016\/j.enbuild.2013.08.063","article-title":"BIM interface for full vs. semi-automated building energy simulation","volume":"68","author":"Ahn","year":"2014","journal-title":"Energy Build."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"103225","DOI":"10.1016\/j.autcon.2020.103225","article-title":"Interoperability and data exchange within BIM platform to evaluate building energy performance and indoor comfort","volume":"116","author":"Utkucu","year":"2020","journal-title":"Autom. Constr."},{"key":"ref_32","unstructured":"Fanger, P.O. (1970). Thermal Comfort-Analysis and Applications in Environmental Engineering, C.D.T. Press."},{"key":"ref_33","unstructured":"Autodesk CFD (2019). Computational Fluid Dynamics Simulation Software, Autodesk Inc."},{"key":"ref_34","unstructured":"Autodesk (2020, December 25). Autodesk Revit. Available online: https:\/\/www.autodesk.com\/products\/revit\/overview."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/13\/4401\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:25:12Z","timestamp":1760163912000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/13\/4401"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,27]]},"references-count":34,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2021,7]]}},"alternative-id":["s21134401"],"URL":"https:\/\/doi.org\/10.3390\/s21134401","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,27]]}}}