{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T16:07:14Z","timestamp":1779293234739,"version":"3.51.4"},"reference-count":41,"publisher":"MDPI AG","issue":"15","license":[{"start":{"date-parts":[[2021,7,29]],"date-time":"2021-07-29T00:00:00Z","timestamp":1627516800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Respiratory monitoring is receiving growing interest in different fields of use, ranging from healthcare to occupational settings. Only recently, non-contact measuring systems have been developed to measure the respiratory rate (fR) over time, even in unconstrained environments. Promising methods rely on the analysis of video-frames features recorded from cameras. In this work, a low-cost and unobtrusive measuring system for respiratory pattern monitoring based on the analysis of RGB images recorded from a consumer-grade camera is proposed. The system allows (i) the automatized tracking of the chest movements caused by breathing, (ii) the extraction of the breathing signal from images with methods based on optical flow (FO) and RGB analysis, (iii) the elimination of breathing-unrelated events from the signal, (iv) the identification of possible apneas and, (v) the calculation of fR value every second. Unlike most of the work in the literature, the performances of the system have been tested in an unstructured environment considering user-camera distance and user posture as influencing factors. A total of 24 healthy volunteers were enrolled for the validation tests. Better performances were obtained when the users were in sitting position. FO method outperforms in all conditions. In the fR range 6 to 60 breaths\/min (bpm), the FO allows measuring fR values with bias of \u22120.03 \u00b1 1.38 bpm and \u22120.02 \u00b1 1.92 bpm when compared to a reference wearable system with the user at 2 and 0.5 m from the camera, respectively.<\/jats:p>","DOI":"10.3390\/s21155126","type":"journal-article","created":{"date-parts":[[2021,7,29]],"date-time":"2021-07-29T21:21:21Z","timestamp":1627593681000},"page":"5126","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":49,"title":["Non-Contact Respiratory Monitoring Using an RGB Camera for Real-World Applications"],"prefix":"10.3390","volume":"21","author":[{"given":"Chiara","family":"Romano","sequence":"first","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Universit\u00e0 Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9696-1265","authenticated-orcid":false,"given":"Emiliano","family":"Schena","sequence":"additional","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Universit\u00e0 Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5863-8336","authenticated-orcid":false,"given":"Sergio","family":"Silvestri","sequence":"additional","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Universit\u00e0 Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3090-5623","authenticated-orcid":false,"given":"Carlo","family":"Massaroni","sequence":"additional","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Universit\u00e0 Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,7,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.annemergmed.2004.06.016","article-title":"The vexatious vital: Neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage","volume":"45","author":"Lovett","year":"2005","journal-title":"Ann. Emerg. Med."},{"key":"ref_2","first-page":"657","article-title":"Respiratory rate: The neglected vital sign","volume":"188","author":"Cretikos","year":"2008","journal-title":"MJA"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"922","DOI":"10.3389\/fphys.2017.00922","article-title":"Respiratory frequency during exercise: The neglected physiological measure","volume":"8","author":"Massaroni","year":"2017","journal-title":"Front. Physiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1111\/j.1365-2044.2005.04186.x","article-title":"A physiologically-based early warning score for ward patients: The association between score and outcome","volume":"60","author":"Goldhill","year":"2005","journal-title":"Anaesthesia"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"852","DOI":"10.1016\/j.sleep.2012.04.005","article-title":"Symptoms of sleep apnea syndrome: High prevalence and underdiagnosis in the French population","volume":"13","author":"Fuhrman","year":"2012","journal-title":"Sleep Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1055\/s-2002-32318","article-title":"Underdiagnosis of sleep apnea syndrome in US communities","volume":"6","author":"Kapur","year":"2002","journal-title":"Sleep Breath."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"8146809","DOI":"10.1155\/2016\/8146809","article-title":"Respiratory changes in response to cognitive load: A systematic review","volume":"2016","author":"Grassmann","year":"2016","journal-title":"Neural Plast."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1080\/15459620903455722","article-title":"Physiological monitoring in firefighter ensembles: Wearable plethysmographic sensor vest versus standard equipment","volume":"7","author":"Coca","year":"2009","journal-title":"J. Occup. Environ. Hyg."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Romano, C., Presti, D.L., Schena, E., Massaroni, C., Formica, D., Caponero, M.A., Oddo, C.M., D\u2019Abbraccio, J., Massari, L., and Longo, U.G. (2019, January 26\u201328). A wearable system based on fiber Bragg grating for monitoring respiratory and heart activity of archers. Proceedings of the 2019 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Istanbul, Turkey.","DOI":"10.1109\/MeMeA.2019.8802177"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Massaroni, C., Nicol\u00f2, A., Lo Presti, D., Sacchetti, M., Silvestri, S., and Schena, E. (2019). Contact-based methods for measuring respiratory rate. Sensors, 19.","DOI":"10.3390\/s19040908"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1152\/jappl.1972.33.2.252","article-title":"Changes in tidal volume, frequency, and ventilation induced by their measurement","volume":"33","author":"Gilbert","year":"1972","journal-title":"J. Appl. Physiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"73558","DOI":"10.1109\/ACCESS.2020.2988038","article-title":"Concurrent respiration monitoring of multiple subjects by phase-comparison monopulse radar using independent component analysis (ICA) with JADE algorithm and direction of arrival (DOA)","volume":"8","author":"Islam","year":"2020","journal-title":"IEEE Access"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Addison, A.P., Addison, P.S., Smit, P., Jacquel, D., and Borg, U.R. (2021). Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature. Sensors, 21.","DOI":"10.3390\/s21041135"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"121705","DOI":"10.1063\/1.4845635","article-title":"An optical measurement method for the simultaneous assessment of respiration and heart rates in preterm infants","volume":"84","author":"Marchionni","year":"2013","journal-title":"Rev. Sci. Instrum."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Massaroni, C., Schena, E., Silvestri, S., Taffoni, F., and Merone, M. (2018, January 11\u201313). Measurement system based on RBG camera signal for contactless breathing pattern and respiratory rate monitoring. Proceedings of the 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Rome, Italy.","DOI":"10.1109\/MeMeA.2018.8438692"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"12821","DOI":"10.1109\/JSEN.2020.3023486","article-title":"Contactless Methods for Measuring Respiratory Rate: A Review","volume":"21","author":"Massaroni","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Leonhardt, S., Leicht, L., and Teichmann, D. (2018). Unobtrusive vital sign monitoring in automotive environments\u2014A review. Sensors, 18.","DOI":"10.3390\/s18093080"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"4567213","DOI":"10.1155\/2018\/4567213","article-title":"Contactless monitoring of breathing patterns and respiratory rate at the pit of the neck: A single camera approach","volume":"2018","author":"Massaroni","year":"2018","journal-title":"J. Sens."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Schrumpf, F., M\u00f6nch, C., Bausch, G., and Fuchs, M. (2019, January 23\u201327). Exploiting weak head movements for camera-based respiration detection. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany.","DOI":"10.1109\/EMBC.2019.8856387"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/JTEHM.2019.2946147","article-title":"Vision-Based Heart and Respiratory Rate Monitoring During Sleep\u2014A Validation Study for the Population at Risk of Sleep Apnea","volume":"7","author":"Zhu","year":"2019","journal-title":"IEEE J. Transl. Eng. Health Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1367","DOI":"10.1109\/JBHI.2016.2567298","article-title":"Noncontact vision-based cardiopulmonary monitoring in different sleeping positions","volume":"21","author":"Li","year":"2016","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"154924","DOI":"10.1109\/ACCESS.2020.3018616","article-title":"Camera-based method for respiratory rhythm extraction from a lateral perspective","volume":"8","year":"2020","journal-title":"IEEE Access"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Brieva, J., Ponce, H., and Moya-Albor, E. (2020). A contactless respiratory rate estimation method using a hermite magnification technique and convolutional neural networks. Appl. Sci., 10.","DOI":"10.3390\/app10020607"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Blinn, J.F. (1977, January 20\u201322). Models of light reflection for computer synthesized pictures. Proceedings of the 4th Annual Conference on COMPUTER Graphics and Interactive Techniques, San Jose, CA, USA.","DOI":"10.1145\/563858.563893"},{"key":"ref_25","unstructured":"Viola, P., and Jones, M. (2001, January 8\u201314). Rapid object detection using a boosted cascade of simple features. Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, CVPR 2001, Kauai, HI, USA."},{"key":"ref_26","unstructured":"Martinez, M., and Stiefelhagen, R. (2012, January 11\u201315). Breath rate monitoring during sleep using near-IR imagery and PCA. Proceedings of the 21st International Conference on Pattern Recognition (ICPR2012), Tsukuba, Japan."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Massaroni, C., Lo Presti, D., Formica, D., Silvestri, S., and Schena, E. (2019). Non-contact monitoring of breathing pattern and respiratory rate via RGB signal measurement. Sensors, 19.","DOI":"10.3390\/s19122758"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1383","DOI":"10.1109\/TPAMI.2012.220","article-title":"Fourier lucas-kanade algorithm","volume":"35","author":"Lucey","year":"2012","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Farneb\u00e4ck, G. (2003). Two-frame motion estimation based on polynomial expansion. Scandinavian Conference on Image Analysis, Springer.","DOI":"10.1007\/3-540-45103-X_50"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/0004-3702(81)90024-2","article-title":"Determining optical flow","volume":"17","author":"Horn","year":"1981","journal-title":"Artif. Intell."},{"key":"ref_31","unstructured":"(2012). BioHarness 3.0 User Manual, Zephyr Technology."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"597","DOI":"10.5664\/jcsm.2172","article-title":"Rules for scoring respiratory events in sleep: Update of the 2007 AASM manual for the scoring of sleep and associated events: Deliberations of the sleep apnea definitions task force of the American Academy of Sleep Medicine","volume":"8","author":"Berry","year":"2012","journal-title":"J. Clin. Sleep Med."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"e12329","DOI":"10.14814\/phy2.12329","article-title":"Universal and individual characteristics of postural sway during quiet standing in healthy young adults","volume":"3","author":"Yamamoto","year":"2015","journal-title":"Physiol. Rep."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"6037","DOI":"10.1109\/JSEN.2017.2731788","article-title":"Smart textile based on 12 fiber Bragg gratings array for vital signs monitoring","volume":"17","author":"Presti","year":"2017","journal-title":"IEEE Sens. J."},{"key":"ref_35","first-page":"307","article-title":"Measurement in medicine: The analysis of method comparison studies","volume":"32","author":"Altman","year":"1983","journal-title":"J. R. Stat. Soc. Ser. D"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1088\/0967-3334\/37\/1\/100","article-title":"Video-based respiration monitoring with automatic region of interest detection","volume":"37","author":"Janssen","year":"2015","journal-title":"Physiol. Meas."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Koley, B., and Dey, D. (December, January 30). Automated detection of apnea and hypopnea events. Proceedings of the 2012 Third International Conference on Emerging Applications of Information Technology, Kolkata, India.","DOI":"10.1109\/EAIT.2012.6407868"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Presti, D.L., Massaroni, C., Schena, P.S.E., Formica, D., Caponero, M.A., and Di Tomaso, G. (2018, January 11\u201313). Smart textile based on FBG sensors for breath-by-breath respiratory monitoring: Tests on women. Proceedings of the 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Rome, Italy.","DOI":"10.1109\/MeMeA.2018.8438721"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1007\/s10877-015-9777-5","article-title":"Wireless non-invasive continuous respiratory monitoring with FMCW radar: A clinical validation study","volume":"30","author":"Breteler","year":"2016","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"036006","DOI":"10.1117\/1.JBO.22.3.036006","article-title":"Synergetic use of thermal and visible imaging techniques for contactless and unobtrusive breathing measurement","volume":"22","author":"Hu","year":"2017","journal-title":"J. Biomed. Opt."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Hu, M., Zhai, G., Li, D., Fan, Y., Duan, H., Zhu, W., and Yang, X. (2018). Combination of near-infrared and thermal imaging techniques for the remote and simultaneous measurements of breathing and heart rates under sleep situation. PLoS ONE, 13.","DOI":"10.1371\/journal.pone.0190466"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/15\/5126\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:36:32Z","timestamp":1760164592000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/15\/5126"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,29]]},"references-count":41,"journal-issue":{"issue":"15","published-online":{"date-parts":[[2021,8]]}},"alternative-id":["s21155126"],"URL":"https:\/\/doi.org\/10.3390\/s21155126","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,29]]}}}