{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T16:46:35Z","timestamp":1761324395203,"version":"build-2065373602"},"reference-count":44,"publisher":"MDPI AG","issue":"17","license":[{"start":{"date-parts":[[2021,9,6]],"date-time":"2021-09-06T00:00:00Z","timestamp":1630886400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Respirable particulate matter air pollution is positively associated with SARS-CoV-2 mortality. Real-time and accurate monitoring of particle concentration changes is the first step to prevent and control air pollution from inhalable particles. In this research, a new light scattering instrument has been developed to detect the mass concentration of inhalable particles. This instrument couples the forward small-angle single particle counting method with the lateral group particle photometry method in a single device. The mass concentration of four sizes of inhalable particles in the environment can be detected simultaneously in a large area in real-time without using a particle impactor. Different from the traditional light scattering instrument, this new optical instrument can detect darker particles with strong light absorption, and the measurement results mainly depend on the particle size and ignore the properties of the particles. Comparative experiments have shown that the instrument can detect particles with different properties by simply calibrating the environmental density parameters, and the measurement results have good stability and accuracy.<\/jats:p>","DOI":"10.3390\/s21175977","type":"journal-article","created":{"date-parts":[[2021,9,6]],"date-time":"2021-09-06T21:47:38Z","timestamp":1630964858000},"page":"5977","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Small-Angle Particle Counting Coupled Photometry for Real-Time Detection of Respirable Particle Size Segmentation Mass Concentration"],"prefix":"10.3390","volume":"21","author":[{"given":"Rongrui","family":"Zhang","sequence":"first","affiliation":[{"name":"Centre for Lidar Remote Sensing Research, School of Mechanical and Precision Instrument Engineering, Xi\u2019an University of Technology, Xi\u2019an 710048, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heng","family":"Zhao","sequence":"additional","affiliation":[{"name":"Centre for Lidar Remote Sensing Research, School of Mechanical and Precision Instrument Engineering, Xi\u2019an University of Technology, Xi\u2019an 710048, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,9,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Chen, C., Tseng, Y., Mukundan, A., and Wang, H. (2021). Air Pollution: Sensitive Detection of PM2.5 and PM10 Concentration Using Hyperspectral Imaging. Appl. Sci., 11.","DOI":"10.3390\/app11104543"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Brattich, E., Bracci, A., Zappi, A., Morozzi, P., Di Sabatino, S., Porcu, F., Di Nicola, F., and Tositti, L. (2020). How to Get the Best from Low-Cost Particulate Matter Sensors: Guidelines and Practical Recommendations. Sensors, 20.","DOI":"10.3390\/s20113073"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/S1352-2310(00)00387-3","article-title":"Monitoring of PM10 and PM2.5 around primary particulate anthropogenic emission sources","volume":"35","author":"Xavier","year":"2001","journal-title":"Atmos. Environ."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Chuchro, M., Sarlej, W., Grzegorczyk, M., and Nurzy\u0144ska, K. (2021). Application of Photo Texture Analysis and Weather Data in Assessment of Air Quality in Terms of Airborne PM10 and PM2.5 Particulate Matter. Sensors, 21.","DOI":"10.3390\/s21165483"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Yu, R., Park, S., Choi, K., Hong, E., and Kim, H. (2020). Air Pollution and Atopic Dermatitis (AD): The Impact of Particulate Matter (PM10) on an AD Mouse-Model. Int. J. Mol. Sci., 21.","DOI":"10.3390\/ijms21176079"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.1007\/s11069-019-03625-0","article-title":"Individual exposure to particulate matter in urban and rural Chinese households: Estimation of exposure concentrations in indoor and outdoor environments","volume":"99","author":"Guo","year":"2019","journal-title":"Nat. Hazards"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"105794","DOI":"10.1016\/j.envint.2020.105794","article-title":"Estimation of airborne viral emission: Quanta emission rate of SARS-CoV-2 for infection risk assessment","volume":"141","author":"Buonanno","year":"2020","journal-title":"Environ. Int."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"670","DOI":"10.5604\/12321966.1185772","article-title":"Monitoring of airborne bacteria and aerosols in different wards of hospitals\u2014Particle counting usefulness in investigation of airborne bacteria","volume":"22","author":"Mirhoseini","year":"2015","journal-title":"Ann. Agric. Environ. Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"115859","DOI":"10.1016\/j.envpol.2020.115859","article-title":"Links between air pollution and COVID-19 in England","volume":"268","author":"Travaglio","year":"2021","journal-title":"Environ. Pollut."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"143929","DOI":"10.1016\/j.scitotenv.2020.143929","article-title":"Air pollution exposure and COVID-19: A look at mortality in Mexico City using individual-level data","volume":"756","author":"Heres","year":"2021","journal-title":"Sci. Total Environ."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"138704","DOI":"10.1016\/j.scitotenv.2020.138704","article-title":"Association between short-term exposure to air pollution and COVID-19 infection: Evidence from China","volume":"727","author":"Zhu","year":"2020","journal-title":"Sci. Total Environ."},{"key":"ref_12","unstructured":"(2021, January 09). List of Designated Reference and Equivalentmethod, Available online: https:\/\/www.epa.gov\/technical-air-pollution-resources."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1080\/10473289.1991.10466903","article-title":"Continuous PM-10 Measurements Using the Tapered Element Oscillating Microbalance","volume":"41","author":"Patashnick","year":"2012","journal-title":"J. Air Waste Manag. Assoc."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/0004-6981(74)90028-6","article-title":"Atmospheric particulate mass monitoring with a \u03b2 radiation detector","volume":"8","author":"Husar","year":"1975","journal-title":"Atmos. Environ."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.1109\/19.746588","article-title":"Algorithm of nonrespirable dust fraction suppression using an optical transducer of dust mass concentration","volume":"47","author":"Gmiterko","year":"2004","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Shao, W., Zhang, H., and Zhou, H. (2017). Fine Particle Sensor Based on Multi-Angle Light Scattering and Data Fusion. Sensors, 17.","DOI":"10.3390\/s17051033"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/1352-2310(94)90251-8","article-title":"Correlations between gravimetry and light scattering photometry for atmospheric aerosols","volume":"28","author":"Thomas","year":"1994","journal-title":"Atmos. Environ."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1016\/0021-8502(95)00049-6","article-title":"Photometer measurement of polydisperse aerosols","volume":"26","author":"Bemer","year":"1995","journal-title":"J. Aerosol Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1117\/12.7972758","article-title":"Design criteria and recent developments of optical single particle counters for fossil fuel systems","volume":"20","author":"Holve","year":"1981","journal-title":"Opt. Eng."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1117\/12.7972624","article-title":"Laser-based single particle counters for in situparticulate diagnostics","volume":"19","author":"Hirleman","year":"1980","journal-title":"Opt. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ijleo.2008.04.003","article-title":"Mass concentration calculation with the pulse height distribution of aerosols and system calibration","volume":"121","author":"Gu","year":"2010","journal-title":"Optik"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1063\/1.3060205","article-title":"Light scattering by small particles","volume":"10","author":"Hulst","year":"1957","journal-title":"Phys. Today"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/j.optcom.2013.12.014","article-title":"Influences of refractive index on forward light scattering","volume":"316","author":"Han","year":"2014","journal-title":"Opt. Commun."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.fuproc.2018.06.016","article-title":"Measurements of particulate matter concentration by the light scattering method: Optimization of the detection angle","volume":"179","author":"Chen","year":"2018","journal-title":"Fuel Process. Technol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"S517","DOI":"10.1016\/0021-8502(90)90294-8","article-title":"Theoretical and methodological approach of photometer calibration","volume":"21","author":"Bemer","year":"1990","journal-title":"J. Aerosol Sci."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1080\/15459624.2019.1628965","article-title":"Sources of error and variability in particulate matter sensor network measurements","volume":"16","author":"Zuidema","year":"2019","journal-title":"J. Occup. Environ. Hyg."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2069","DOI":"10.17973\/MMSJ.2017_12_201788","article-title":"Calibration of photometer-based direct-reading aerosol monitors","volume":"2017","author":"Da","year":"2017","journal-title":"MM Sci. J."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1039\/C1EM10558B","article-title":"Workplace aerosol mass concentration measurement using optical particle counters","volume":"14","author":"Simon","year":"2012","journal-title":"J. Environ. Monit. JEM"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Sousan, S., Regmi, S., and Park, Y.M. (2021). Laboratory Evaluation of Low-Cost Optical Particle Counters for Environmental and Occupational Exposures. Sensors, 21.","DOI":"10.3390\/s21124146"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1029\/2007JD009607","article-title":"Determination of index of refraction and size of supermicrometer particles from light scattering measurements at two angles","volume":"113","author":"Eidhammer","year":"2008","journal-title":"J. Geophys. Res. Atmos."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1006\/icar.1999.6188","article-title":"Results of the PROGRA 2 Experiment: An Experimental Study in Microgravity of Scattered Polarized Light by Dust Particles with Large Size Parameter","volume":"142","author":"Worms","year":"1999","journal-title":"Icarus"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"L95","DOI":"10.1088\/0022-3727\/14\/6\/003","article-title":"The complex refractive index of particles","volume":"14","author":"Gupta","year":"2000","journal-title":"J. Phys. D Appl. Phys."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"22171","DOI":"10.1029\/1999JD900460","article-title":"In situ observations and model calculations of black carbon emission by aircraft at cruise altitude","volume":"104","author":"Petzold","year":"1999","journal-title":"J. Geophys. Res. Atmos."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1115\/1.2824213","article-title":"Refractive Indices at Visible Wavelengths of Soot Emitted From Buoyant Turbulent Diffusion Flames","volume":"119","author":"Wu","year":"1997","journal-title":"J. Heat Transfer."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Chen, D., Liu, X., Han, J., Jiang, M., and Qi, J. (2019). A New Angular Light Scattering Measurement of Particulate Matter Mass Concentration for Homogeneous Spherical Particles. Sensors, 19.","DOI":"10.3390\/s19102243"},{"key":"ref_36","first-page":"337","article-title":"Pioneering mathematical description of scattering by spheres","volume":"25","author":"Mie","year":"1908","journal-title":"Ann. Phys."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1021\/j100830a502","article-title":"Mie theory of light scattering\u2014Limitations on accuracy of approximate methods of computation","volume":"64","author":"Murley","year":"1960","journal-title":"J. Phys. Chem."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1364\/AO.5.000839","article-title":"Particle Sizing by Means of the Forward Scattering Lobe","volume":"5","author":"Hodkinson","year":"1966","journal-title":"Appl. Opt."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1364\/AO.14.000734","article-title":"Response Calculations for Light-Scattering Aerosol Particle Counters","volume":"14","author":"Cooke","year":"1975","journal-title":"Appl. Opt."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"3141","DOI":"10.1109\/TSP.2005.851110","article-title":"Gradient-Based Variable Forgetting Factor RLS Algorithm in Time-Varying Environments","volume":"53","author":"Leung","year":"2005","journal-title":"IEEE Trans. Signal Process."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Zhang, R., and Zhao, H. (2021). A Novel Method for Online Extraction of Small-Angle Scattering Pulse Signals from Particles Based on Variable Forgetting Factor RLS Algorithm. Sensors, 21.","DOI":"10.3390\/s21175759"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1137\/0806023","article-title":"An Interior Trust Region Approach for Nonlinear Minimization Subject to Bounds","volume":"6","author":"Coleman","year":"1993","journal-title":"SIAM J. Optim."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Lourakis, M., and Argyros, A.A. (2005, January 17\u201320). Is Levenberg-Marquardt the Most Efficient Optimization Algorithm for Implementing Bundle Adjustment?. Proceedings of the 10th IEEE International Conference on Computer Vision (ICCV 2005), Beijing, China.","DOI":"10.1109\/ICCV.2005.128"},{"key":"ref_44","first-page":"1353","article-title":"The problem of the convergence of the iteratively regularized Gauss-Newton method","volume":"32","author":"Bakushinskii","year":"1992","journal-title":"Comput. Math. Math. Phys."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/17\/5977\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:57:28Z","timestamp":1760165848000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/17\/5977"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,6]]},"references-count":44,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2021,9]]}},"alternative-id":["s21175977"],"URL":"https:\/\/doi.org\/10.3390\/s21175977","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2021,9,6]]}}}