{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T03:13:27Z","timestamp":1791083607870,"version":"4.1.0"},"reference-count":24,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2021,9,7]],"date-time":"2021-09-07T00:00:00Z","timestamp":1630972800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Gait and jump anomalies are often used as indicators to identify the presence and state of disorders that involve motor symptoms. Physical tests are often performed in specialized laboratories, which offer reliable and accurate results, but require long and costly analyses performed by specialized personnel. The use of inertial sensors for gait and jump evaluation offers an easy-to-use low-cost alternative, potentially applicable by the patients themselves at home. In this paper, we compared three inertial measurement units that are available on the market by means of well-known standardized tests for the evaluation of gait and jump behavior. The aim of the study was to highlight the strengths and weaknesses of each of the tested sensors, considered in different tests, by comparing data collected on two healthy subjects. Data were processed to identify the phases of the movement and the possible inaccuracies of each sensor. The analysis showed that some of the considered inertial units could be reliably used to identify the gait and jump phases and could be employed to detect anomalies, potentially suggesting the presence of disorders.<\/jats:p>","DOI":"10.3390\/s21185990","type":"journal-article","created":{"date-parts":[[2021,9,8]],"date-time":"2021-09-08T02:41:07Z","timestamp":1631068867000},"page":"5990","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["A Comparative Evaluation of Inertial Sensors for Gait and Jump Analysis"],"prefix":"10.3390","volume":"21","author":[{"given":"Isaia","family":"Andrenacci","sequence":"first","affiliation":[{"name":"Department of Engineering and Architecture (DEA), University of Parma, 43124 Parma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3571-3671","authenticated-orcid":false,"given":"Riccardo","family":"Boccaccini","sequence":"additional","affiliation":[{"name":"Department of Engineering and Architecture (DEA), University of Parma, 43124 Parma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alice","family":"Bolzoni","sequence":"additional","affiliation":[{"name":"Department of Engineering and Architecture (DEA), University of Parma, 43124 Parma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0577-8626","authenticated-orcid":false,"given":"Giulio","family":"Colavolpe","sequence":"additional","affiliation":[{"name":"Department of Engineering and Architecture (DEA), University of Parma, 43124 Parma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0563-5235","authenticated-orcid":false,"given":"Cosimo","family":"Costantino","sequence":"additional","affiliation":[{"name":"Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelangelo","family":"Federico","sequence":"additional","affiliation":[{"name":"Department of Engineering and Architecture (DEA), University of Parma, 43124 Parma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7021-9145","authenticated-orcid":false,"given":"Alessandro","family":"Ugolini","sequence":"additional","affiliation":[{"name":"Department of Engineering and Architecture (DEA), University of Parma, 43124 Parma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5939-4134","authenticated-orcid":false,"given":"Armando","family":"Vannucci","sequence":"additional","affiliation":[{"name":"Department of Engineering and Architecture (DEA), University of Parma, 43124 Parma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,9,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1016\/j.jbiomech.2004.02.047","article-title":"Quantification of human motion: Gait analysis-benefits and limitations to its application to clinical problems","volume":"37","author":"Simon","year":"2004","journal-title":"J. Biomech."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-020-00685-3","article-title":"Validity and reliability of wearable inertial sensors in healthy adult walking: A systematic review and meta-analysis","volume":"17","author":"Kobsar","year":"2020","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., and von Zitzewitz, J. (2021). Wearable Sensor-Based Real-Time Gait Detection: A Systematic Review. Sensors, 21.","DOI":"10.3390\/s21082727"},{"key":"ref_4","unstructured":"XSENS Technologies (2018). MTw Awinda User Manual, XSENS."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1561\/2000000094","article-title":"Using Inertial Sensors for Position and Orientation Estimation","volume":"11","author":"Kok","year":"2017","journal-title":"Found. Trends Signal Process."},{"key":"ref_6","unstructured":"Paulich, M., Schepers, M., Rudigkeit, N., and Bellusci, G. (2018). XSENS MTw Awinda: Miniature Wireless Inertial-Magnetic Motion Tracker for Highly Accurate 3D Kinematic Applications, XSENS. XSENS Technologies White Paper."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1016\/0021-9290(95)00017-C","article-title":"ISB recommendations for standardization in the reporting of kinematic data","volume":"28","author":"Wu","year":"1995","journal-title":"J. Biomech."},{"key":"ref_8","unstructured":"BTS Bioengineering (2018). BTS G-Sensor2 Hardware Manual, BTS S.p.A."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Tunca, C., Pehlivan, N., Arnrich, B., and Salur, G. (2017). Inertial Sensor-Based Robust Gait Analysis in Non-Hospital Settings for Neurological Disorders. Sensors, 17.","DOI":"10.3390\/s17040825"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1111\/j.1532-5415.1991.tb01616.x","article-title":"The Timed Up and Go: A test of basic functional mobility for frail elderly persons","volume":"39","author":"Podsiadlo","year":"1991","journal-title":"J. Am. Geriatr. Soc."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1519\/00139143-200608000-00004","article-title":"Reference values for the timed up and go test: A descriptive meta-analysis","volume":"29","author":"Bohannon","year":"2006","journal-title":"J. Geriatr. Phys. Ther."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1109\/RBME.2015.2390646","article-title":"Toward Automating Clinical Assessments: A Survey of the Timed Up and Go","volume":"8","author":"Sprint","year":"2015","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.medengphy.2009.10.015","article-title":"Can an accelerometer enhance the utility of the Timed up and Go Test when evaluating patients with Parkinson\u2019s disease?","volume":"32","author":"Weiss","year":"2010","journal-title":"Med. Eng. Phys."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Beyea, J., McGibbon, C.A., Sexton, A., Noble, J., and O\u2019Connell, C. (2017). Convergent Validity of a Wearable Sensor System for Measuring Sub-Task Performance during the Timed up and Go Test. Sensors, 17.","DOI":"10.3390\/s17040934"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.gaitpost.2017.07.030","article-title":"Novel methodology for estimating Initial Contact events from accelerometers positioned at different body locations","volume":"59","author":"Khandelwal","year":"2018","journal-title":"Gait Posture"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1159\/000511611","article-title":"Robust Step Detection from Different Waist-Worn Sensor Positions: Implications for Clinical Studies","volume":"4","author":"Tietsch","year":"2020","journal-title":"Digit. Biomark"},{"key":"ref_17","unstructured":"Strozzi, N. (2018). Pedestrian Inertial Navigation. [Ph.D. Thesis, University of Parma]."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Alvarez, D., Gonzalez, R.C., Lopez, A., and Alvarez, J.C. (September, January 31). Comparison of Step Length Estimators from Wearable Accelerometer Devices. Proceedings of the 2006 International Conference of the IEEE Engineering in Medicine and Biology Society, New York, NY, USA.","DOI":"10.1109\/IEMBS.2006.259593"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/S0966-6362(97)00021-0","article-title":"Displacement of the pelvis during human walking: Experimental data and model predictions","volume":"6","author":"Zijlstra","year":"1997","journal-title":"Gait Posture"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Gonzalez, R.C., Alvarez, D., Lopez, A.M., and Alvarez, J.C. (2007, January 23\u201326). Modified Pendulum Model for Mean Step Length Estimation. Proceedings of the 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Lyon, France.","DOI":"10.1109\/IEMBS.2007.4352553"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/s12283-015-0185-3","article-title":"Quantifying the effects of load carriage and fatigue under load on sacral kinematics during countermovement vertical jump with IMU-based method","volume":"19","author":"McGinnis","year":"2016","journal-title":"Sport. Eng."},{"key":"ref_22","first-page":"843","article-title":"Vertical jumping biomechanical evaluation through the use of an inertial sensor-based technology","volume":"4","author":"Setuain","year":"2015","journal-title":"J. Sport. Sci."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2127","DOI":"10.1152\/jappl.1991.71.6.2127","article-title":"Hopping frequency in humans: A test of how springs set stride frequency in bouncing gaits","volume":"71","author":"Farley","year":"1991","journal-title":"J. Appl. Physiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"3737","DOI":"10.1242\/jeb.033191","article-title":"Development of lower limb stiffness and its contribution to maximum vertical jumping power during adolescence","volume":"212","author":"Korff","year":"2009","journal-title":"J. Exp. Biol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/18\/5990\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:57:56Z","timestamp":1760165876000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/18\/5990"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,7]]},"references-count":24,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2021,9]]}},"alternative-id":["s21185990"],"URL":"https:\/\/doi.org\/10.3390\/s21185990","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,7]]}}}