{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,21]],"date-time":"2026-03-21T02:51:56Z","timestamp":1774061516654,"version":"3.50.1"},"reference-count":48,"publisher":"MDPI AG","issue":"20","license":[{"start":{"date-parts":[[2021,10,9]],"date-time":"2021-10-09T00:00:00Z","timestamp":1633737600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Zhejiang Provincial Natural Science Foundation of China","award":["No.LY19F010010 and No. LY18F030016."],"award-info":[{"award-number":["No.LY19F010010 and No. LY18F030016."]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Respiratory rate is a critical vital sign that indicates health condition, sleep quality, and exercise intensity. This paper presents a non-invasive, ultra-low-power, and cost-effective wireless wearable sensor, which is installed on an off-the-shelf KN95 mask to facilitate respiration monitoring. The sensing principle is based on the periodic airflow temperature variations caused by exhaled hot air and inhaled cool air in respiratory cycles. By measuring the periodic temperature variations at the exhalation valve of mask, the respiratory parameters can be accurately and reliably detected, regardless of body movements and breathing pathways through nose or mouth. Specifically, we propose a voltage divider with controllable resistors and corresponding selection criteria to improve the sensitivity of temperature measurement, a peak detection algorithm with spline interpolation to increase sampling period without reducing the detection accuracy, and effective low-power optimization measures to prolong the battery life. The experimental results have demonstrated the effectiveness of the proposed sensor, showing a small mean absolute error (MAE) of 0.449 bpm and a very low power consumption of 131.4 \u03bcW. As a high accuracy, low cost, low power, and reusable miniature wearing device for convenient respiration monitoring in daily life, the proposed sensor holds promise in real-world feasibility.<\/jats:p>","DOI":"10.3390\/s21206698","type":"journal-article","created":{"date-parts":[[2021,10,10]],"date-time":"2021-10-10T21:37:49Z","timestamp":1633901869000},"page":"6698","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Towards Accurate, Cost-Effective, Ultra-Low-Power and Non-Invasive Respiration Monitoring: A Reusable Wireless Wearable Sensor for an Off-the-Shelf KN95 Mask"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2605-2816","authenticated-orcid":false,"given":"Yu","family":"Xu","sequence":"first","affiliation":[{"name":"College of Computer Science and Artificial Intelligence, Wenzhou University, Wenzhou 325035, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi","family":"Li","sequence":"additional","affiliation":[{"name":"College of Computer Science and Artificial Intelligence, Wenzhou University, Wenzhou 325035, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7997-6038","authenticated-orcid":false,"given":"Zhenzhou","family":"Tang","sequence":"additional","affiliation":[{"name":"College of Computer Science and Artificial Intelligence, Wenzhou University, Wenzhou 325035, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Liu","sequence":"additional","affiliation":[{"name":"College of Computer Science and Artificial Intelligence, Wenzhou University, Wenzhou 325035, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bingjin","family":"Xiang","sequence":"additional","affiliation":[{"name":"College of Computer Science and Artificial Intelligence, Wenzhou University, Wenzhou 325035, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,10,9]]},"reference":[{"key":"ref_1","unstructured":"(2020, March 27). Diagnosis and Treatment Protocol of COVID-19 (Trial Version 7); National Health Commission & State Administration of Traditional Chinese Medicine: Beijing, China, 3 March 2020. Available online: http:\/\/covid-19.chinadaily.com.cn\/a\/202003\/27\/WS5e7c25baa310128217282337.html."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1007\/BF02600071","article-title":"Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients","volume":"8","author":"Fieselmann","year":"1993","journal-title":"J. Gen. Intern. Med."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13049-016-0213-8","article-title":"The association between vital signs and mortality in a retrospective cohort study of an unselected emergency department population","volume":"24","author":"Ljunggren","year":"2016","journal-title":"Scand. J. Trauma Resusc. Emerg. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1109\/JETCAS.2017.2789278","article-title":"Noncontact sleep stage estimation using a CW Doppler radar","volume":"8","author":"Hong","year":"2018","journal-title":"IEEE J. Emerg. Sel. Top. Circuits Syst."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1159\/000327660","article-title":"Obstructive sleep apnea in adults: Epidemiology, clinical presentation, and treatment options","volume":"46","author":"Lurie","year":"2011","journal-title":"Adv. Cardiol."},{"key":"ref_6","unstructured":"Coates, B., and Kowalchik, C. (2013). Runner\u2019s World Running on the Air: The Revolutionary Way to Run Better by Breathing Smarter, Rodale Books."},{"key":"ref_7","first-page":"23","article-title":"Respiratory rate 1: Why accurate measurement and recording are crucial","volume":"114","author":"Kelly","year":"2018","journal-title":"Nurs. Times"},{"key":"ref_8","first-page":"21","article-title":"Respiratory rate 3: How to take an accurate measurement","volume":"114","author":"Wheatley","year":"2018","journal-title":"Nurs. Times"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1109\/JSEN.2019.2942099","article-title":"An Integrated Wearable Wireless Vital Signs Biosensor for Continuous Inpatient Monitoring","volume":"20","author":"Wong","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_10","first-page":"170","article-title":"Method for measuring respiration in sleep: Capnography for determining ventilation","volume":"6","year":"2003","journal-title":"Biomed. Tech."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"657","DOI":"10.5694\/j.1326-5377.2008.tb01825.x","article-title":"Respiratory rate: The neglected vital sign","volume":"188","author":"Cretikos","year":"2008","journal-title":"Med. J. Aust."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1109\/TBME.2019.2923448","article-title":"Breathing Rate Estimation Using Kalman Smoother With Electrocardiogram and Photoplethysmogram","volume":"67","author":"Khreis","year":"2020","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/LSENS.2019.2926834","article-title":"FBSE-EWT-based approach for the determination of respiratory rate from PPG signals","volume":"3","author":"Katiyar","year":"2019","journal-title":"IEEE Sens. Lett."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2807","DOI":"10.1109\/JLT.2018.2883413","article-title":"Noninvasive measurement of heart rate and respiratory rate for perioperative infants","volume":"37","author":"Zhang","year":"2019","journal-title":"J. Light. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1935","DOI":"10.1109\/TIM.2014.2366976","article-title":"Evaluation of pressure bed sensor for automatic SAHS screening","volume":"64","author":"Mora","year":"2015","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"10067","DOI":"10.1115\/1.4034465","article-title":"Unconstrained measurement of respiration motions of chest and abdomen using a tactile sensor sheet in supine position on bed","volume":"10","author":"Guo","year":"2016","journal-title":"J. Med. Devices"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"6182","DOI":"10.1109\/JSEN.2020.2974313","article-title":"Noninvasive monitoring of vital signs based on highly sensitive fiber optic mattress","volume":"20","author":"Wang","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2173","DOI":"10.1109\/JSEN.2019.2949608","article-title":"Respiratory monitoring during physical activities with a multi-sensor smart garment and related algorithms","volume":"20","author":"Massaroni","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1109\/JSEN.2014.2339739","article-title":"Weft-knitted strain sensor for monitoring respiratory rate and its electro-mechanical modeling","volume":"15","author":"Atalay","year":"2015","journal-title":"IEEE Sens. J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"13167","DOI":"10.3390\/s121013167","article-title":"Development of a respiratory inductive plethysmography module supporting multiple sensors for wearable systems","volume":"12","author":"Zhang","year":"2012","journal-title":"Sensors"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/JTEHM.2019.2946147","article-title":"Vision-based heart and respiratory rate monitoring during sleep\u2014A validation study for the population at risk of sleep apnea","volume":"7","author":"Zhu","year":"2019","journal-title":"IEEE J. Transl. Eng. Health Med."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1109\/TBME.2020.2993649","article-title":"Multispectral video fusion for non-contact monitoring of respiratory rate and apnea","volume":"68","author":"Scebba","year":"2021","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"8300","DOI":"10.1109\/ACCESS.2018.2890082","article-title":"An unobtrusive and non-contact method for respiratory measurement with respiratory region detecting algorithm based on depth images","volume":"7","author":"Sun","year":"2018","journal-title":"IEEE Access"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Hou, Y., Wang, Y., and Zheng, Y. (2017, January 5\u20138). TagBreathe: Monitor Breathing with Commodity RFID Systems. Proceedings of the 37th International Conference on Distributed Computing Systems (ICDCS), Atlanta, GA, USA.","DOI":"10.1109\/ICDCS.2017.76"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"9841","DOI":"10.1109\/JSEN.2019.2927536","article-title":"RF-based noncontact respiratory rate monitoring with parametric spectral estimation","volume":"19","author":"Uysal","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Wang, X., Yang, C., and Mao, S. (2017, January 5\u20138). Phasebeat: Exploiting CSI phase data for vital sign monitoring with commodity WiFi devices. Proceedings of the 37th International Conference on Distributed Computing Systems (ICDCS), Atlanta, GA, USA.","DOI":"10.1109\/ICDCS.2017.206"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"4483","DOI":"10.1109\/TMTT.2017.2684138","article-title":"Accurate measurement in Doppler radar vital sign detection based on parameterized demodulation","volume":"65","author":"Xiong","year":"2017","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_28","first-page":"1","article-title":"Vital-SCOPE: Design and Evaluation of a Smart Vital Sign Monitor for Simultaneous Measurement of Pulse Rate, Respiratory Rate, and Body Temperature for Patient Monitoring","volume":"11","author":"Sun","year":"2018","journal-title":"J. Sens."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"11065","DOI":"10.1109\/JIOT.2021.3051580","article-title":"2-D Localization, Angular Separation and Vital Signs Monitoring Using a SISO FMCW Radar for Smart Long-term Health Monitoring Environments","volume":"8","author":"Mercuri","year":"2021","journal-title":"IEEE Internet Things J."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"334","DOI":"10.5370\/JEET.2014.9.1.334","article-title":"Improvement of dynamic respiration monitoring through sensor fusion of accelerometer and gyro-sensor","volume":"9","author":"Yoon","year":"2014","journal-title":"J. Electr. Eng. Technol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1109\/JSEN.2018.2877617","article-title":"A Wireless Respiratory Monitoring System Using a Wearable Patch Sensor Network","volume":"2","author":"Elfaramawy","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2145","DOI":"10.1109\/JSEN.2018.2791400","article-title":"Wireless wearable magnetometer-based sensor for sleep quality monitoring","volume":"18","author":"Milici","year":"2018","journal-title":"IEEE Sens. J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"103829","DOI":"10.1016\/j.nanoen.2019.06.025","article-title":"An integrated flexible self-powered wearable respiration sensor","volume":"63","author":"Wang","year":"2019","journal-title":"Nano Energy"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1964","DOI":"10.1109\/JBHI.2018.2885138","article-title":"Evaluation of a wearable device to determine cardiorespiratory parameters from surface diaphragm electromyography","volume":"23","author":"Estrada","year":"2019","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2735","DOI":"10.1109\/JSEN.2018.2887303","article-title":"Low-cost and portable impedance plethysmography system for the simultaneous detection of respiratory and heart activities","volume":"19","author":"Piuzzi","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1111\/j.1365-2044.2009.05908.x","article-title":"Thoracic impedance monitoring of respiratory rate during sedation\u2014Is it safe?","volume":"64","author":"Wilkinson","year":"2010","journal-title":"Anaesthesia"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"4378","DOI":"10.1364\/BOE.6.004378","article-title":"Remote monitoring of breathing dynamics using infrared thermography","volume":"6","author":"Pereira","year":"2015","journal-title":"Biomed. Opt. Express"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"4480","DOI":"10.1364\/BOE.8.004480","article-title":"Robust tracking of respiratory rate in high- dynamic range scenes using mobile thermal imaging","volume":"8","author":"Cho","year":"2017","journal-title":"Biomed. Opt. Express"},{"key":"ref_39","unstructured":"Ren, Y., Wang, C., Yang, J., and Chen, Y. (May, January 26). Fine-grained sleep monitoring: Hearing your breathing with smartphones. Proceedings of the Conference on Computer Communications (INFOCOM), Hong Kong, China."},{"key":"ref_40","first-page":"445","article-title":"A 9.6 nW, 8-Bit, 100 S\/s envelope-to-digital converter for respiratory monitoring","volume":"67","author":"Shi","year":"2020","journal-title":"IEEE Trans. Circuits Syst. II Express Briefs"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"2959","DOI":"10.1109\/JIOT.2018.2877607","article-title":"Contactless respiration monitoring using ultrasound signal with off-the-shelf audio devices","volume":"6","author":"Wang","year":"2019","journal-title":"IEEE Internet Things J."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Ono, Y., Mohamed, D., Kobayashi, M., and Jen, C. (2008, January 2\u20135). Piezoelectric membrane sensor and technique for breathing monitoring. Proceedings of the IEEE Ultrasonics Symposium, Beijing, China.","DOI":"10.1109\/ULTSYM.2008.0191"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1109\/JSEN.2016.2645766","article-title":"Wireless breathing sensor based on wearable modulated frequency selective surface","volume":"17","author":"Milici","year":"2017","journal-title":"IEEE Sens. J."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"31738","DOI":"10.3390\/s151229881","article-title":"Smart sensing strip using monolithically integrated flexible flow sensor for noninvasively monitoring respiratory flow","volume":"15","author":"Peng","year":"2015","journal-title":"Sensors"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1109\/JSEN.2011.2161668","article-title":"Dew-based wireless mini module for respiratory rate monitoring","volume":"12","author":"Andre","year":"2012","journal-title":"IEEE Sens. J."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"6067","DOI":"10.1021\/acsnano.0c01804","article-title":"Alveolus-Inspired Active Membrane Sensors for Self-Powered Wearable Chemical Sensing and Breath Analysis","volume":"14","author":"Su","year":"2020","journal-title":"ACS Nano"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Xiang, B., Xu, Y., Zhou, M., Zheng, Y., Zhan, L., Fan, J., Zhou, D., and Liu, J. (2019, January 20\u201322). Wireless Wearable Respirator for Accurate Measurement of Breathing Parameters. Proceedings of the 2nd International Conference on Electronic Information and Communication Technology (ICEICT), Harbin, China.","DOI":"10.1109\/ICEICT.2019.8846401"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Andraka, R. (1998, January 22\u201325). A survey of CORDIC algorithms for FPGA based computers. Proceedings of the ACM\/SIGDA Internaitonal Symposium on Field Programmable Gate Arrays, Monterey, CA, USA.","DOI":"10.1145\/275107.275139"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/20\/6698\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:10:51Z","timestamp":1760166651000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/20\/6698"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,9]]},"references-count":48,"journal-issue":{"issue":"20","published-online":{"date-parts":[[2021,10]]}},"alternative-id":["s21206698"],"URL":"https:\/\/doi.org\/10.3390\/s21206698","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,9]]}}}