{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T14:36:27Z","timestamp":1776868587954,"version":"3.51.2"},"reference-count":44,"publisher":"MDPI AG","issue":"20","license":[{"start":{"date-parts":[[2021,10,9]],"date-time":"2021-10-09T00:00:00Z","timestamp":1633737600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Quantification of renal perfusion based on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) requires determination of signal intensity time courses in the region of renal parenchyma. Thus, selection of voxels representing the kidney must be accomplished with special care and constitutes one of the major technical limitations which hampers wider usage of this technique as a standard clinical routine. Manual segmentation of renal compartments\u2014even if performed by experts\u2014is a common source of decreased repeatability and reproducibility. In this paper, we present a processing framework for the automatic kidney segmentation in DCE-MR images. The framework consists of two stages. Firstly, kidney masks are generated using a convolutional neural network. Then, mask voxels are classified to one of three regions\u2014cortex, medulla, and pelvis\u2013based on DCE-MRI signal intensity time courses. The proposed approach was evaluated on a cohort of 10 healthy volunteers who underwent the DCE-MRI examination. MRI scanning was repeated on two time events within a 10-day interval. For semantic segmentation task we employed a classic U-Net architecture, whereas experiments on voxel classification were performed using three alternative algorithms\u2014support vector machines, logistic regression and extreme gradient boosting trees, among which SVM produced the most accurate results. Both segmentation and classification steps were accomplished by a series of models, each trained separately for a given subject using the data from other participants only. The mean achieved accuracy of the whole kidney segmentation was 94% in terms of IoU coefficient. Cortex, medulla and pelvis were segmented with IoU ranging from 90 to 93% depending on the tissue and body side. The results were also validated by comparing image-derived perfusion parameters with ground truth measurements of glomerular filtration rate (GFR). The repeatability of GFR calculation, as assessed by the coefficient of variation was determined at the level of 14.5 and 17.5% for the left and right kidney, respectively and it improved relative to manual segmentation. Reproduciblity, in turn, was evaluated by measuring agreement between image-derived and iohexol-based GFR values. The estimated absolute mean differences were equal to 9.4 and 12.9 mL\/min\/1.73 m2 for scanning sessions 1 and 2 and the proposed automated segmentation method. The result for session 2 was comparable with manual segmentation, whereas for session 1 reproducibility in the automatic pipeline was weaker.<\/jats:p>","DOI":"10.3390\/s21206714","type":"journal-article","created":{"date-parts":[[2021,10,10]],"date-time":"2021-10-10T21:37:49Z","timestamp":1633901869000},"page":"6714","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Healthy Kidney Segmentation in the Dce-Mr Images Using a Convolutional Neural Network and Temporal Signal Characteristics"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4045-5870","authenticated-orcid":false,"given":"Artur","family":"Klepaczko","sequence":"first","affiliation":[{"name":"Institute of Electronics, Lodz University of Technology, 90-924 \u0141\u00f3d\u017a, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eli","family":"Eikefjord","sequence":"additional","affiliation":[{"name":"Department of Health and Functioning, Western Norway University of Applied Sciences, 5063 Bergen, Norway"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arvid","family":"Lundervold","sequence":"additional","affiliation":[{"name":"Department of Health and Functioning, Western Norway University of Applied Sciences, 5063 Bergen, Norway"},{"name":"Department of Biomedicine, University of Bergen, 5009 Bergen, Norway"},{"name":"Mohn Medical Imaging and Visualization Centre, Department of Radiology, Haukeland University Hospital, 5021 Bergen, Norway"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,10,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1089\/end.2016.0143","article-title":"Use of the Modification of Diet in Renal Disease Equation for Estimating Glomerular Filtration Rate in the Urologic Literature","volume":"30","author":"Zabell","year":"2016","journal-title":"J. Endourol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1093\/ckj\/sfw070","article-title":"Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: A review. Part 1: How to measure glomerular filtration rate with iohexol?","volume":"9","author":"Delanaye","year":"2016","journal-title":"Clin. Kidney J."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1002\/jmri.20173","article-title":"Glomerular filtration rate: Assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney","volume":"20","author":"Annet","year":"2004","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1097\/RLI.0b013e31815597c5","article-title":"MRI-measurement of perfusion and glomerular filtration in the human kidney with a separable compartment model","volume":"43","author":"Sourbron","year":"2008","journal-title":"Investig. Radiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1007\/s00330-012-2382-9","article-title":"Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values","volume":"22","author":"Tofts","year":"2012","journal-title":"Eur. Radiol."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Chen, B., Zhang, Y., Song, X., Wang, X., Zhang, J., and Fang, J. (2014). Quantitative Estimation of Renal Function with Dynamic Contrast-Enhanced MRI Using a Modified Two-Compartment Model. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0105087"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"e154","DOI":"10.1016\/j.ejrad.2009.05.041","article-title":"The importance of AIF ROI selection in DCE-MRI renography: Reproducibility and variability of renal perfusion and filtration","volume":"74","author":"Cutajar","year":"2010","journal-title":"Eur. J. Radiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"F1548","DOI":"10.1152\/ajprenal.00347.2006","article-title":"Renal function measurements from MR renography and a simplified multicompartmental model","volume":"292","author":"Lee","year":"2007","journal-title":"Am. J. Physiol.-Renal Physiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1038\/jcbfm.1985.87","article-title":"Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data. Generalizations","volume":"5","author":"Patlak","year":"1985","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1002\/jmri.10410","article-title":"Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique","volume":"18","author":"Hackstein","year":"2003","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.compmedimag.2008.11.004","article-title":"Assessment of 3D DCE-MRI of the kidneys using non-rigid image registration and segmentation of voxel time courses","volume":"33","author":"Sance","year":"2009","journal-title":"Comput. Med. Imaging Graph."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.compmedimag.2011.06.005","article-title":"Wavelet-based segmentation of renal compartments in DCE-MRI of human kidney: Initial results in patients and healthy volunteers","volume":"36","author":"Li","year":"2012","journal-title":"Comput. Med. Imaging Graph."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1177\/0284185116666417","article-title":"Dynamic contrast-enhanced MRI measurement of renal function in healthy participants","volume":"58","author":"Eikefjord","year":"2017","journal-title":"Acta Radiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.media.2016.05.006","article-title":"Renal compartment segmentation in DCE-MRI images","volume":"32","author":"Yang","year":"2016","journal-title":"Med. Image Anal."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1696","DOI":"10.1002\/mrm.26806","article-title":"Automatic renal segmentation for MR urography using 3D-GrabCut and random forests","volume":"79","author":"Yoruk","year":"2018","journal-title":"Magn. Reson. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.zemedi.2018.11.002","article-title":"An overview of deep learning in medical imaging focusing on MRI","volume":"29","author":"Lundervold","year":"2019","journal-title":"Z. F\u00fcr Med. Phys."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Khan, Z., Yahya, N., Alsaih, K., Ali, S.S.A., and Meriaudeau, F. (2020). Evaluation of Deep Neural Networks for Semantic Segmentation of Prostate in T2W MRI. Sensors, 20.","DOI":"10.3390\/s20113183"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1109\/TPAMI.2016.2572683","article-title":"Fully Convolutional Networks for Semantic Segmentation","volume":"39","author":"Shelhamer","year":"2017","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2481","DOI":"10.1109\/TPAMI.2016.2644615","article-title":"SegNet: A Deep Convolutional Encoder-Decoder Architecture for Image Segmentation","volume":"39","author":"Badrinarayanan","year":"2017","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Ronneberger, O., Fischer, P., and Brox, T. (2015, January 5\u20139). U-Net: Convolutional Networks for Biomedical Image Segmentation. Proceedings of the 18th International Conference on Medical Image Computing and Computer Assisted Intervention, Munich, Germany.","DOI":"10.1007\/978-3-319-24574-4_28"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Chen, L.C., Zhu, Y., Papandreou, G., Schroff, F., and Adam, H. (2018, January 8\u201314). Encoder-Decoder with Atrous Separable Convolution for Semantic Image Segmentation. Proceedings of the European Conference on Computer Vision 2018, Munich, Germany.","DOI":"10.1007\/978-3-030-01234-2_49"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1007\/s10278-017-9978-1","article-title":"Performance of an Artificial Multi-observer Deep Neural Network for Fully Automated Segmentation of Polycystic Kidneys","volume":"30","author":"Kline","year":"2017","journal-title":"J. Digit. Imaging"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.3389\/fneur.2018.01147","article-title":"Convolutional Neural Networks for Direct Inference of Pharmacokinetic Parameters: Application to Stroke Dynamic Contrast-Enhanced MRI","volume":"9","author":"Ulas","year":"2019","journal-title":"Front. Neurol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"101821","DOI":"10.1016\/j.media.2020.101821","article-title":"The state of the art in kidney and kidney tumor segmentation in contrast-enhanced CT imaging: Results of the KiTS19 challenge","volume":"67","author":"Heller","year":"2021","journal-title":"Med. Image Anal."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"T\u00fcrk, F., L\u00fcy, M., and Bar\u0131\u015f\u00e7\u0131, N. (2020). Kidney and Renal Tumor Segmentation Using a Hybrid V-Net-Based Model. Mathematics, 8.","DOI":"10.3390\/math8101772"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Haghighi, M., Warfield, S.K., and Kurugol, S. (2018, January 4\u20137). Automatic renal segmentation in DCE-MRI using convolutional neural networks. Proceedings of the 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018), Washington, DC, USA.","DOI":"10.1109\/ISBI.2018.8363865"},{"key":"ref_27","unstructured":"Johnson, H.J., McCormick, M.M., and Ibanez, L. (2021, October 07). The ITK Software Guide: Design and Functionality. Available online: https:\/\/itk.org\/ItkSoftwareGuide.pdf."},{"key":"ref_28","unstructured":"Tata, V. (2021, January 07). Semantic Segmentation on Medical Images. Available online: https:\/\/github.com\/venkateshtata\/SemanticSegmentation."},{"key":"ref_29","first-page":"1929","article-title":"Dropout: A Simple Way to Prevent Neural Networks from Overfitting","volume":"15","author":"Srivastava","year":"2014","journal-title":"J. Mach. Learn. Res."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"He, K., Zhang, X., Ren, S., and Sun, J. (2015, January 7\u201313). Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification. Proceedings of the IEEE International Conference on Computer Vision (ICCV), Santiago, Chile.","DOI":"10.1109\/ICCV.2015.123"},{"key":"ref_31","unstructured":"Bishop, C.M. (2006). Pattern Recognition and Machine Learning, Springer."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1007\/s10107-016-1030-6","article-title":"Minimizing Finite Sums with the Stochastic Average Gradient","volume":"162","author":"Schmidt","year":"2017","journal-title":"Math. Program."},{"key":"ref_33","first-page":"2825","article-title":"Scikit-learn: Machine Learning in Python","volume":"12","author":"Pedregosa","year":"2011","journal-title":"J. Mach. Learn. Res."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Vapnik, V. (2000). The Nature of Statistical Learning Theory, Springer.","DOI":"10.1007\/978-1-4757-3264-1"},{"key":"ref_35","first-page":"2579","article-title":"Visualizing Data using t-SNE","volume":"9","author":"Hinton","year":"2008","journal-title":"J. Mach. Learn. Res."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Chen, T., and Guestrin, C. (2016, January 13\u201317). XGBoost: A Scalable Tree Boosting System. Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining, San Francisco, CA, USA.","DOI":"10.1145\/2939672.2939785"},{"key":"ref_37","unstructured":"Bammer, R. (2016). MR and CT Perfusion and Pharmacokinetic Imaging. Clinical Applications and Theory, Wolters Kluwer."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s10107-015-0893-2","article-title":"Recent advances in trust region algorithms","volume":"151","author":"Yuan","year":"2015","journal-title":"Math. Program."},{"key":"ref_39","unstructured":"Klepaczko, A. (2021, September 30). Pharmacokinetic Model Fitting Software. Available online: https:\/\/gitlab.com\/aklepaczko\/quantitativeperfusion."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Klepaczko, A., Strzelecki, M., Kocio\u0142ek, M., Eikefjord, E., and Lundervold, A. (2020). A Multi-Layer Perceptron Network for Perfusion Parameter Estimation in DCE-MRI Studies of the Healthy Kidney. Appl. Sci., 10.","DOI":"10.3390\/app10165525"},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Tofts, P.S. (2003). QA: Quality Assurance, Accuracy, Precision and Phantoms. Quantitative MRI of the Brain, John Wiley & Sons.","DOI":"10.1002\/0470869526.ch3"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1002\/uog.5256","article-title":"Reliability, repeatability and reproducibility: Analysis of measurement errors in continuous variables","volume":"31","author":"Bartlett","year":"2008","journal-title":"Ultrasound Obstet. Gynecol."},{"key":"ref_43","first-page":"403","article-title":"Accuracy of GFR estimating equations combining standardized cystatin C and creatinine assays: A cross-sectional study in Sweden","volume":"53","author":"Grubb","year":"2015","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1007\/s00330-014-3130-0","article-title":"Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: Quantification and reproducibility","volume":"24","author":"Cutajar","year":"2014","journal-title":"Eur. Radiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/20\/6714\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:11:11Z","timestamp":1760166671000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/20\/6714"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,9]]},"references-count":44,"journal-issue":{"issue":"20","published-online":{"date-parts":[[2021,10]]}},"alternative-id":["s21206714"],"URL":"https:\/\/doi.org\/10.3390\/s21206714","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,9]]}}}