{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T07:22:12Z","timestamp":1780730532889,"version":"3.54.1"},"reference-count":31,"publisher":"MDPI AG","issue":"22","license":[{"start":{"date-parts":[[2021,11,12]],"date-time":"2021-11-12T00:00:00Z","timestamp":1636675200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>It is recognized that gait analysis is a powerful tool used to capture human locomotion and quantify the related parameters. PODOSmart\u00ae insoles have been designed to provide accurate measurements for gait analysis. PODOSmart\u00ae insoles are lightweight, slim and cost-effective. A recent publication presented the characteristics and data concerning the validity of PODOSmart\u00ae insoles in gait analysis. In literature, there is still no evidence about the repeatability of PODOSmart\u00ae gait analysis system. Such evidence is essential in order to use this device in both research and clinical settings. The aim of the present study was to assess the repeatability of PODOSmart\u00ae system. In this context, it was hypothesized that the parameters of gait analysis captured by PODOSmart\u00ae would be repeatable. In a sample consisting of 22 healthy male adults, participants performed two walking trials on a six-meter walkway. The ICC values for 28 gait variables provided by PODOSmart\u00ae indicated good to excellent test-retest reliability, ranging from 0.802 to 0.997. The present findings confirm that PODOSmart\u00ae gait analysis insoles present excellent repeatability in gait analysis parameters. These results offer additional evidence regarding the reliability of this gait analysis tool.<\/jats:p>","DOI":"10.3390\/s21227532","type":"journal-article","created":{"date-parts":[[2021,11,14]],"date-time":"2021-11-14T20:51:53Z","timestamp":1636923113000},"page":"7532","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Test-Retest Reliability of PODOSmart\u00ae Gait Analysis Insoles"],"prefix":"10.3390","volume":"21","author":[{"given":"Andreas","family":"Loukovitis","sequence":"first","affiliation":[{"name":"Department of Physical Education and Sport Science, Aristotle University of Thessaloniki, 57001 Thessaloniki, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Efthymios","family":"Ziagkas","sequence":"additional","affiliation":[{"name":"Department of Physical Education and Sport Science, Aristotle University of Thessaloniki, 57001 Thessaloniki, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dimitrios Xypolias","family":"Zekakos","sequence":"additional","affiliation":[{"name":"Digitsole SAS, 54000 Nancy, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9156-4896","authenticated-orcid":false,"given":"Alexandros","family":"Petrelis","sequence":"additional","affiliation":[{"name":"Digitsole SAS, 54000 Nancy, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Grouios","sequence":"additional","affiliation":[{"name":"Department of Physical Education and Sport Science, Aristotle University of Thessaloniki, 57001 Thessaloniki, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,11,12]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1434","DOI":"10.1109\/TBME.2004.827933","article-title":"Gait assessment in Parkinson\u2019s disease: Toward an ambulatory system for long-term monitoring","volume":"51","author":"Salarian","year":"2004","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"DeBerardinis, J., Dufek, J.S., Trabia, M.B., and Lidstone, D.E. (2018). Assessing the validity of pressure-measuring insoles in quantifying gait variables. J. Rehabil. Assist. Technol. Eng., 5.","DOI":"10.1177\/2055668317752088"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Ziagkas, E., Loukovitis, A., Zekakos, D.X., Chau, T.D.-P., Petrelis, A., and Grouios, G. (2021). A Novel Tool for Gait Analysis: Validation Study of the Smart Insole PODOSmart\u00ae. Sensors, 21.","DOI":"10.3390\/s21175972"},{"key":"ref_4","unstructured":"Joint Committee for Guides in Metrology (2008). Evaluation of measurement data- guide to the expression of uncertainty in measurement. JCGM, 100, 1\u2013116."},{"key":"ref_5","unstructured":"Buelow, M. (2020). Risky Decision Making in Psychological Disorders, Academic Press."},{"key":"ref_6","unstructured":"Baldacchini, T. (2020). Motion systems: An overview of linear, air bearing, and piezo stages. Micro and Nano Technologies, Three-Dimensional Microfabrication Using Two-Photon Polymerization, William Andrew Publishing. [2nd ed.]."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2165\/00007256-200030010-00001","article-title":"Measures of reliability in sports medicine and science","volume":"30","author":"Hopkins","year":"2000","journal-title":"Sports Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.jbiomech.2004.10.028","article-title":"Validity of the Pedar Mobile system for vertical force measurement during a seven-hour period","volume":"39","author":"Hurkmans","year":"2006","journal-title":"J. Biomech."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1016\/j.gaitpost.2006.05.010","article-title":"The Pedar\u00ae in-shoe system: Repeatability and normal pressure values","volume":"25","author":"Putti","year":"2007","journal-title":"Gait Posture"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1186\/s13047-015-0111-8","article-title":"Validation and reliability testing of a new, fully integrated gait analysis insole","volume":"11","author":"Braun","year":"2015","journal-title":"J. Foot Ankle Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1080\/02640414.2016.1161205","article-title":"Validation of Moticon\u2019s OpenGo sensor insoles during gait, jumps, balance and cross-country skiing specific imitation movements","volume":"35","author":"Martiner","year":"2017","journal-title":"J. Sports Sci."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.gaitpost.2016.10.005","article-title":"Concurrent validity and reliability of wireless instrumented insoles measuring postural balance and temporal gait parameters","volume":"51","author":"Oerbekke","year":"2017","journal-title":"Gait Posture"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Peebles, A., Maguire, L., Renner, K., and Queen, R. (2018). Validity and Repeatability of Single-Sensor Loadsol Insoles during Landing. Sensors, 18.","DOI":"10.3390\/s18124082"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.gaitpost.2016.01.026","article-title":"Validity and repeatability of three in-shoe pressure measurement systems","volume":"46","author":"Price","year":"2016","journal-title":"Gait Posture"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.foot.2007.04.002","article-title":"BioFoot\u00ae in-shoe system: Normal values and assessment of the reliability and repeatability","volume":"17","year":"2007","journal-title":"Foot"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1186\/1743-0003-11-95","article-title":"Test-retest reliability of an insole plantar pressure system to assess gait along linear and curved trajectories","volume":"11","author":"Godi","year":"2014","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Jiang, Y., Wang, D., Ying, J., Chu, P., Qian, Y., and Chen, W. (2021). Design and Preliminary Validation of Individual Customized Insole for Adults with Flexible Flatfeet Based on the Plantar Pressure Redistribution. Sensors, 21.","DOI":"10.3390\/s21051780"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Duong, T.T.H., Goldman, S., Zhang, H., Salazar, R., Beenders, S., Cornett, K.M., Bain, J.M., Montes, J., and Zanotto, D. (December, January 29). Validation of Insole-Based Gait Analysis System in Young Children with a Neurodevelopmental Disorder and Autism Traits. Proceedings of the 2020 8th IEEE RAS\/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob), New York, NY, USA.","DOI":"10.1109\/BioRob49111.2020.9224273"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"756","DOI":"10.2340\/16501977-1015","article-title":"Reliability and validity of a kinematic spine model during active trunk movement in healthy subjects and patients with chronic non-specific low back pain","volume":"44","author":"Hidalgo","year":"2012","journal-title":"J. Rehabil. Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1310\/sci1803-273","article-title":"Minimal detectable change for spatial and temporal measurements of gait after incomplete spinal cord injury","volume":"18","author":"Nair","year":"2012","journal-title":"Top Spinal. Cord. Inj. Rehabil."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/1743-0003-3-4","article-title":"Gait analysis methods in rehabilitation","volume":"3","author":"Baker","year":"2006","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1016\/j.medengphy.2013.11.011","article-title":"Development and validation of a low-cost, portable and wireless gait assessment tool","volume":"36","author":"Macleod","year":"2014","journal-title":"Med. Eng. Phys."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1616","DOI":"10.1109\/JSEN.2020.3016642","article-title":"Technology-Based Complex Motor Tasks Assessment: A 6-DOF Inertial-Based System versus a Gold-Standard Optoelectronic-Based One","volume":"21","author":"Saggio","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1016\/j.jbiomech.2004.02.047","article-title":"Quantification of human motion: Gait analysis\u2014Benefits and limitations to its application to clinical problems","volume":"37","author":"Simon","year":"2004","journal-title":"J. Biomech."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"e003114","DOI":"10.1590\/1980-5918.031.ao14","article-title":"Test-retest reliability of baropodometry in young asyntomatic individuals during semi static and dynamic analysis","volume":"31","author":"Alves","year":"2018","journal-title":"Fisioter. Mov."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1761","DOI":"10.1108\/ECAM-05-2020-0330","article-title":"Validity and reliability of a wearable insole pressure system for measuring gait parameters to identify safety hazards in construction","volume":"28","author":"Li","year":"2021","journal-title":"Eng. Constr. Archit. Manag."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.foot.2011.11.001","article-title":"Repeatability of WalkinSense\u00ae in shoe pressure measurement system: A preliminary study","volume":"22","author":"Healy","year":"2012","journal-title":"Foot"},{"key":"ref_29","first-page":"348659","article-title":"Accuracy and repeatability of the gait analysis by the WalkinSense system","volume":"2014","author":"Meucci","year":"2014","journal-title":"BioMed Res. Int."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Barratt, G.K., Bellenger, C., Robertson, E.Y., Lane, J., and Crowther, R.G. (2021). Validation of Plantar Pressure and Reaction Force Measured by Moticon Pressure Sensor Insoles on a Concept2 Rowing Ergometer. Sensors, 21.","DOI":"10.3390\/s21072418"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1080\/10749357.2020.1792717","article-title":"FeetMe\u00ae Monitor-connected insoles are a valid and reliable alternative for the evaluation of gait speed after stroke","volume":"28","author":"Farid","year":"2021","journal-title":"Top. Stroke Rehabil."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/22\/7532\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:29:26Z","timestamp":1760167766000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/22\/7532"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11,12]]},"references-count":31,"journal-issue":{"issue":"22","published-online":{"date-parts":[[2021,11]]}},"alternative-id":["s21227532"],"URL":"https:\/\/doi.org\/10.3390\/s21227532","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,11,12]]}}}